Which G-Tube to Use in Pullers: Assessment of Pull Pressures on Skin Models to Determine Optimal Catheter Choice in Patients with Recurrent Pulled Gastrostomy Tubes

Introduction: Pulled or dislodged gastrostomy catheters represent a common complication associated with percutaneous gastrostomy and are a common cause of recurrent visits in patients with altered mental status. We intended to perform an experiment to compare the pull forces required to dislodge different commonly used gastrostomy catheters. Materials and Methods: We used a digital force gauge device to measure the pull forces required to dislodge three types of 20 French gastrostomy catheters in double-layer skin models. These included the Flow 20 Pull Method (Cook Medical, Bloomington, IN, USA), Entuit Gastrostomy BR Balloon Retention feeding tube (Cook Medical, Bloomington, IN, USA), and Ponsky Non-Balloon Replacement Gastrostomy Tube (CR Bard Inc, Salt Lake City, Utah, USA). The catheters were inserted into the skin model using the same technique as would be utilized in a patient. Results: The mean forces measured to dislodge the per-oral Flow 20 Pull Method, Entuit Thrive Balloon Retention, and button-type retention Ponsky replacement catheters were 35.6, 22.8, and 20.6 Newtons, respectively. The pull method per-oral gastrostomy catheter required significantly more pull force to dislodge than both the Ponsky button-type retention catheter and the Entuit balloon retention catheters. There was no significant difference in the pull force required to dislodge the Ponsky replacement catheter and the Entuit balloon retention catheter. Conclusions: Per-oral image-guided gastrostomy with pull-method button-type retention catheters may be the ideal choice in patients at high risk of tube dislodgment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Push-pull tracer tests: Their information content and use for characterizing non-Fickian, mobile-immobile behavior: INFORMATION CONTENT OF PUSH-PULL TESTS

Path reversibility and radial symmetry are often assumed in push-pull tracer test analysis. In reality, heterogeneous flow fields mean that both assumptions are idealizations. In this paper, to understand their impact, we perform a parametric study which quantifies the scattering effects of ambient flow, local-scale dispersion, and velocity field heterogeneity on push-pull breakthrough curves and compares them to the effects of mobile-immobile mass transfer (MIMT) processes including sorption and diffusion into secondary porosity. We identify specific circumstances in which MIMT overwhelmingly determines the breakthrough curve, which may then be considered uninformative about drift and local-scale dispersion. Assuming path reversibility, we develop a continuous-time-random-walk-based interpretation framework which is flow-field-agnostic and well suited to quantifying MIMT. Adopting this perspective, we show that the radial flow assumption is often harmless: to the extent that solute paths are reversible, the breakthrough curve is uninformative about velocity field heterogeneity. Our interpretation method determines a mapping function (i.e., subordinator) from travel time in the absence of MIMT to travel time in its presence. A mathematical theory allowing this function to be directly “plugged into” an existing Laplace-domain transport model to incorporate MIMT is presented and demonstrated. Algorithms implementing the calibration are presented and applied to interpretation of data from a push-pull test performed in a heterogeneous environment. A successful four-parameter fit is obtained, of comparable fidelity to one obtained using a million-node 3-D numerical model. In conclusion, we demonstrate analytically and numerically how push-pull tests quantifying MIMT are sensitive to remobilization, but not immobilization, kinetics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

β-Functionalized trans -A2B2 push–pull tetrabenzoporphyrins

A series of β-functionalized trans-A2B2 tetrabenzoporphyrins have been successfully designed and synthesized through newly developed regioselective bromination chemistry of porphyrins and a Pd(0) catalyzed three-step-one pot reaction. These benzoporphyrins exhibit unique patterns of UV-Vis absorptions and emissions. Tetrabenzoporphyrins possess a unique combination of photophysical, optoelectronic, and physicochemical properties due to their largely extended π-conjugation and associated dynamics of ring deformation which make them distinctive from their parent porphyrins. As compared with their parent porphyrins, tetrabenzoporphyrins often display significantly red-shifted absorption bands, a much-desired feature for various applications ranging from biomedicine to organic electronics. However, due to limited synthetic methods, only a small number of simple symmetrical tetrabenzoporphyrins have been available for study. Unsymmetrical tetrabenzoporphyrins, in particular those functionalized at the porphyrin β-positions, are very difficult to access. A2B2 porphyrins, on the other hand, represent an attractive class of materials for non-linear optical applications as well as for other applications such as those involving dye-sensitized solar cells. meso-Functionalized push–pull trans-A2B2 porphyrins have previously been made available through the Suzuki coupling reaction, the Heck reaction and the Sonogashira coupling reaction of 5,10-dibromoporphyrin with the corresponding alkyl boronic acids, olefins and alkynes, respectively and have demonstrated interesting non-linear optical properties. In contrast, β-functionalized push–pull A2B2 porphyrins of the type shown in Fig. 1 have until now remained unknown. Furthermore, we present the synthesis and characterization for the first examples of β-functionalized A2B2 push–pull tetrabenzoporphyrins.

Kumar, Siddhartha↗

β-Functionalized push–pull opp-dibenzoporphyrins as sensitizers for dye-sensitized solar cells: the role of the phenylethynyl bridge

A novel class of β-functionalized push–pull zinc opp-dibenzoporphyrins was designed and synthesized as sensitizers for dye-sensitized solar cells. Dibenzoporphyrin YH7 displayed strong push–pull characteristics, which included clearly segregated HOMO/LUMO and fast charge injection from the singlet excited state of zinc porphyrin to the conduction band of TiO 2 . The incorporation of both the phenylethynyl bridge and amino group was critical to achieve the enhanced push–pull effect. The highest PCE value in this series obtained with the YH6 cell was 6.7%, which is comparable to that of the best ruthenium dye, N719 (η = 7.4%), under similar conditions. The high PCE of the YH6 cell is ascribed to its high light harvesting ability and favorable cell kinetics, which is supported by electrochemical impedance spectroscopy studies and femtosecond transient absorption studies. An unusual illumination-induced photodegradation was observed for YH7, which was attributed as the major reason for the unexpected lower PCE of the YH7 cell (η = 5.7%). Furthermore, this work demonstrates the applicability of π-extended porphyrins as a new generation of sensitizers for high performance dye-sensitized solar cells.

Hu, Yi↗

Measurement of colour flow using jet-pull observables in $t\bar{t}$ events with the ATLAS experiment at $\sqrt{s} = 13\,\hbox {TeV}$

Previous studies have shown that weighted angular moments derived from jet constituents encode the colour connections between partons that seed the jets. This paper presents measurements of two such distributions, the jet-pull angle and jet-pull magnitude, both of which are derived from the jet-pull angular moment. The measurement is performed in $t\bar{t}$ events with one leptonically decaying W boson and one hadronically decaying W boson, using 36.1fb -1 of pp collision data recorded by the ATLAS detector at s√=13 TeV delivered by the Large Hadron Collider. The observables are measured for two dijet systems, corresponding to the colour-connected daughters of the W boson and the two b-jets from the top-quark decays, which are not expected to be colour connected. To allow the comparison of the measured distributions to colour model predictions, the measured distributions are unfolded to particle level, after correcting for experimental effects introduced by the detector. While good agreement can be found for some combinations of predictions and observables, none of the predictions describes the data well across all observables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Control of the Orientational Order and Nonlinear Optical Response of the "Push-Pull" Chromophore RuPZn via Specific Incorporation into Densely Packed Monolayer Ensembles of an Amphiphilic Four-Helix Bundle Peptide: Characterization of the Peptide−Chromophore Complexes

'Push-pull' chromophores based on extended π-electron systems have been designed to exhibit exceptionally large molecular hyperpolarizabilities. We have engineered an amphiphilic four-helix bundle peptide to vectorially incorporate such hyperpolarizable chromophores having a metalloporphyrin moiety, with high specificity into the interior core of the bundle. The amphiphilic exterior of the bundle facilitates the formation of densely packed monolayer ensembles of the vectorially oriented peptide-chromophore complexes at the liquid-gas interface. Chemical specificity designed into the ends of the bundle facilitates the subsequent covalent attachment of these monolayer ensembles onto the surface of an inorganic substrate. In this article, we describe the structural characterization of these monolayer ensembles at each stage of their fabrication for one such peptide-chromophore complex designated as AP0-RuPZn. In the accompanying article, we describe the characterization of their macroscopic nonlinear optical properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excited-State Charge Transfer in Push–Pull Platinum(II) π-Extended Porphyrins Fused with Pentacenequinone

Platinum(II) π-extended porphyrins fused with pentacenequinone and dihydropentacene have been successfully synthesized. These porphyrins were investigated using various techniques including absorption, steady-state, and time-resolved phosphorescence spectroscopy and differential pulse voltammetry. UV–vis absorption spectra of pentacenequinone-fused porphyrins (SW-Pt1 and SW-Pt2) showed unusually broad and nontypical absorption patterns. Phosphorescence spectra of SW-Pt1, SW-Pt2, and SW-Pt3 displayed similar emissions in the 704–706 nm region indicating electronic transitions of similar origin; however, the triplet lifetimes were found to be quenched in the case of both SW-Pt1 and SW-Pt2, suggesting the occurrence of excited-state events. Facile reductions were obtained for both the pentacene-quinone-fused monomer (SW-Pt2) and dimer (SW-Pt1) and were identified to be located at the pentacenequinone components. Here, the observed orbital segregations for SW-Pt2 and SW-Pt1 from DFT calculations supported the possibility of charge transfer in these push–pull systems. Interestingly, the established energy level diagram revealed that the charge transfer from the triplet excited Pt porphyrin is thermodynamically an uphill process. Systematic studies involving both femtosecond and nanosecond transient absorption techniques revealed that the singlet excited Pt porphyrins undergo an intermediate charge transfer state prior to populating the triplet state, providing a plausible explanation for phosphorescence quenching. The lifetime of the intermediate charge transfer states was found to be 25.9 and 5.68 ps, respectively, for SW-Pt1 and SW-Pt2.

Charge transfer↗

Pulling of 3 mm diameter AlSb rods by micro-pulling down method

We designed and supplied special crucibles for AlSb material. Thermal insulation and limitation of Sb losses were our first work. The protection of the growth environment was also one of our priority to avoid any pollution of the Fibercryst {mu}PD facility. When this work was achieved, the next step was the calibration of the heating power for these new crucibles. Then, it was the definition of single crystal growth conditions that oriented our research. Following our proposal, many growths attempts were performed. We started from Al & Sb pure powder or from LBNL AlSb crystal as expected. We used different crucibles and different seeds.

36 MATERIALS SCIENCE↗

Fluoroscopy-Guided Pull-Through Gastrostomy

The purpose of this study was to simplify a fluoroscopy guided gastrostomy technique using pull-type tubes which are traditionally introduced with gastroscopic assistance. The stomach was transorally probed with a 5-Fr catheter and a guidewire. A second access was performed percutaneously through the anterior abdominal and gastric wall using an 8-Fr sheath and an 8-Fr guiding catheter. A duplicated guidewire was introduced through the guiding catheter in order to result in a great custom-made loop within the stomach. The transoral guidewire was captured and tightened with this loop and the guiding catheter, and both were subsequently pulled by the transoral guidewire until the tip of the guiding catheter exited the mouth. A thread was fed through the guiding catheter for fixation of the pull-type gastrostomy tube. Finally, the fixed tube was pulled through the esophagus into the stomach and through the abdominal wall until the anterior gastric wall fixed the retention plate of the tube. Thirty-seven patients (28 male, 9 female; age, 65.1 {+-} 14.4 years) with miscellaneous indications for percutaneous gastrostomies were supplied with pull-type gastrostomy catheters in a fluoroscopy technique without endoscopic assistance. Twenty-five of the 37 patients (67.6%) had undergone unsuccessful preceding gastroscopically guided PEG attempts because of tumor stenosis (n = 12) or impossible transillumination of the abdominal wall (n = 13). All procedures were technically successful, without major complications. Particularly, all patients with frustrating gastroscopic attempts were successfully provided with pull-type gastrostomy tubes. Five minor complications occurred: one tube loss during the passage of the hypopoharynx because of a torn thread, one transient small leakage alongside the tube (both successfully treated), and three cases of transient moderate local pain without leakage (symptomatic treatment). We conclude that this fluoroscopy-guided pull-through gastrostomy technique is easy and safe to perform and may be suggested as a standard procedure for radiological gastrostomies. It combines the ease of the radiological approach with the advantages of the pull-type tube devices, particularly the benefits of the typical retention plates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An analysis of the pull strength behaviors of fine-pitch, flip chip solder interconnections using a Au-Pt-Pd thick film conductor on Low-Temperature, Co-fired Ceramic (LTCC) substrates.

The assembly of the BDYE detector requires the attachment of sixteen silicon (Si) processor dice (eight on the top side; eight on the bottom side) onto a low-temperature, co-fired ceramic (LTCC) substrate using 63Sn-37Pb (wt.%, Sn-Pb) in a double-reflow soldering process (nitrogen). There are 132 solder joints per die. The bond pads were gold-platinum-palladium (71Au-26Pt-3Pd, wt.%) thick film layers fired onto the LTCC in a post-process sequence. The pull strength and failure modes provided the quality metrics for the Sn-Pb solder joints. Pull strengths were measured in both the as-fabricated condition and after exposure to thermal cycling (-55/125 C; 15 min hold times; 20 cycles). Extremely low pull strengths--referred to as the low pull strength phenomenon--were observed intermittently throughout the product build, resulting in added program costs, schedule delays, and a long-term reliability concern for the detector. There was no statistically significant correlation between the low pull strength phenomenon and (1) the LTCC 'sub-floor' lot; (2) grit blasting the LTCC surfaces prior to the post-process steps; (3) the post-process parameters; (4) the conductor pad height (thickness); (5) the dice soldering assembly sequence; or (5) the dice pull test sequence. Formation of an intermetallic compound (IMC)/LTCC interface caused by thick film consumption during either the soldering process or by solid-state IMC formation was not directly responsible for the low-strength phenomenon. Metallographic cross sections of solder joints from dice that exhibited the low pull strength behavior, revealed the presence of a reaction layer resulting from an interaction between Sn from the molten Sn-Pb and the glassy phase at the TKN/LTCC interface. The thick film porosity did not contribute, explicitly, to the occurrence of reaction layer. Rather, the process of printing the very thin conductor pads was too sensitive to minor thixotropic changes to ink, which resulted in inconsistent proportions of metal and glassy phase particles present during the subsequent firing process. The consequences were subtle, intermittent changes to the thick film microstructure that gave rise to the reaction layer and, thus, the low pull strength phenomenon. A mitigation strategy would be the use of physical vapor deposition (PVD) techniques to create thin film bond pads; this is multi-chip module, deposited (MCM-D) technology.

36 MATERIALS SCIENCE↗

Pull-out simulations of a capped carbon nanotube in carbon nanotube-reinforced nanocomposites

Systematic atomic simulations based on molecular mechanics were conducted to investigate the pull-out behavior of a capped carbon nanotube (CNT) in CNT-reinforced nanocomposites. Two common cases were studied: the pull-out of a complete CNT from a polymer matrix in a CNT/polymer nanocomposite and the pull-out of the broken outer walls of a CNT from the intact inner walls (i.e., the sword-in-sheath mode) in a CNT/alumina nanocomposite. By analyzing the obtained relationship between the energy increment (i.e., the difference in the potential energy between two consecutive pull-out steps) and the pull-out displacement, a set of simple empirical formulas based on the nanotube diameter was developed to predict the corresponding pull-out force. The predictions from these formulas are quite consistent with the experimental results. Moreover, the much higher pull-out force for a capped CNT than that of the corresponding open-ended CNT implies a significant contribution from the CNT cap to the interfacial properties of the CNT-reinforced nanocomposites. This finding provides a valuable insight for designing nanocomposites with desirable mechanical properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ring Pull Strain Analysis Version 1.1

This report details an analysis package, Ring Pull Strain Analysis (RPSA), that can be used to present and quantify digital image correlation (DIC) data as it relates to a gaugeless ring pull test. Gaugeless ring pull is a testing technique for mechanical testing of small annular samples, usually cut from a thin-walled tube. DIC data is often necessary for this kind of test because bending moments present on the ring cause a non-uniform strain distribution and localized measurements are necessary. In addition, the annular geometry of a ring lends itself to a polar representation, which is not present with typical DIC analysis methods. RPSA was made to calculate and plot the polar representation of strain from standard pre-processed DIC data of a gaugeless ring pull test. Further analysis can be done on ring pull including a quasi-uniaxial tensile analysis and coating analysis, which are also performed by RPSA. In addition, due to the universality of DIC plotting and ring pull test analysis, RPSA can accommodate a wide variety of tests, though it is tailored for ring pull testing. This report details how RPSA works, including the theory, assumptions, and logic behind the calculations and the structure of the program.

36 MATERIALS SCIENCE↗

Push-pull tests for estimating effective porosity: expanded analytical solution and in situ application

The analytical solution describing the one-dimensional displacement of the center of mass of a tracer during an injection, drift, and extraction test (push-pull test) was expanded to account for displacement during the injection phase. The solution was expanded to improve the in situ estimation of effective porosity. The truncated equation assumed displacement during the injection phase was negligible, which may theoretically lead to an underestimation of the true value of effective porosity. To experimentally compare the expanded and truncated equations, single-well push-pull tests were conducted across six test wells located in a shallow, unconfined aquifer comprised of unconsolidated and heterogeneous silty and clayey fill materials. The push-pull tests were conducted by injection of bromide tracer, followed by a non-pumping period, and subsequent extraction of groundwater. The values of effective porosity from the expanded equation (0.6–5.0%) were substantially greater than from the truncated equation (0.1–1.3%). The expanded and truncated equations were compared to data from previous push-pull studies in the literature and demonstrated that displacement during the injection phase may or may not be negligible, depending on the aquifer properties and the push-pull test parameters. The results presented here also demonstrated the spatial variability of effective porosity within a relatively small study site can be substantial, and the error-propagated uncertainty of effective porosity can be mitigated to a reasonable level (< ± 0.5%). The tests presented here are also the first that the authors are aware of that estimate, in situ, the effective porosity of fine-grained fill material.

58 GEOSCIENCES↗

On the pull-in behavior of optical injection phase-lock loop

This paper presents a detailed study of the pull-in behavior of an optical injection phase-lock loop (OIPLL) neglecting the noise components of the loop. We provide formulas for pull-in voltage and pull-in range of OIPLL in terms of the loop propagation delay, line-width enhancement factor and other parameters of the loop. In addition, we give a compact expression for the frequency pulling time of OIPLL for low injection and high injection level in presence of loop-delay. The effects of loop-delay and optical injection on the pull-in performance of the OIPLL are studied for non-zero values of line-width enhancement factor. Analytical expression of the maximum allowable loop delay is presented to study the deterministic stability of the loop. From the stochastic stability of the loop, we provide formula for the maximum value of the laser line-width to achieve the desired tracking performance. The simulation results are given in partial support of the conclusions of the analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗