Quantitative time-resolved diagnostics of electric field dynamics during individual plasma breakdown events using burst laser pulse electric field induced second harmonic generation

In plasma discharges, the acceleration of electrons by a fast varying electric field and the subsequent collisional electron energy transfer determines the plasma dynamics, chemical reactivity, and breakdown. Current in situ electric field measurements require reconstruction of the temporal profile over many observations. However, such methods are unsuitable for non-repetitive and unstable plasmas. Here, in this paper, we present a method for creating “movies” of dynamic electric fields in a single acquisition at sample rates of 500 × 10 6 fps. This ultrafast diagnostic was demonstrated in radio frequency electric fields between two parallel plates in air, as well as in Ar nanosecond-pulsed single-sided dielectric barrier discharges.

42 ENGINEERING↗

Next steps in high-repetition-rate laser development for Thomson scattering

Design of a next generation high-rep-rate laser system is underway, aiming for a maximum rep rate of 100 kHz for 1 ms. This will be a "pulse-burst" laser, which is a type of heat-capacity laser. Heat-capacity laser operation is characterized by a burst of pulses of limited duration, with burst length ≤100 ms and pulse rep rate ≥1 kHz. Waste heat accumulates in the laser rod during the burst. This heat is deposited evenly throughout the rod volume, with very little heat removed during the burst, such that temperature rises evenly across the rod radius. Thus beam distortion due to thermal gradients is small. Heat is removed from the rod after the burst, with typically tens of seconds between bursts. Pulse-burst operation of flashlamp pumped Nd:YAG lasers is a cost-effective route to high-rep-rate capability. Pulse-burst laser systems with "fast burst" rep rates in the range of 10–20 kHz have been built for the Thomson scattering diagnostics on MST, NSTX-U, and LHD. For Thomson scattering diagnostic application, the typical requirements are 1064 nm, 1–2 J/pulse, ≤30 ns FWHM pulse, with a top-hat beam profile. A major requirement for this next generation laser system is flexibility in burst sequence programs, ranging from 1 kHz for 100 ms to 100 kHz for 1 ms, and a variety of scenarios in between so that operation can be tailored to plasma experiment requirements. Flashlamp pumping will be used for this next generation laser because it is inexpensive and flexible. A new switch-regulated flashlamp driver will provide improved flashlamp control at lower cost. Additional design issues such as the optimum flashlamp pumping spectrum and optimum Nd doping will be addressed. The use of commercial off-the-shelf components will be maximized in this laser system so that pulse-burst systems can be developed and built by others for new applications.

47 OTHER INSTRUMENTATION↗

Burst delay line for generating ultrashort pulse bursts with interval tunability from femtoseconds to nanoseconds.

Ultrashort burst laser pulses are important for applications in laser processing and spectroscopy. However, existing burst generators face limitations in pulse time interval tunability and coaxiality. Here, we present a burst pulse generator that delivers coaxial ultrashort pulses with tunable pulse time intervals using a single translation stage. The constructed system produced eight femtosecond pulses with uniform intervals tunable from 100 fs to 1.93 ns, equivalent to burst-internal repetition rates spanning 10 THz to 0.52 GHz. We further demonstrated interval-dependent plasma emission in air filamentation, providing a compact platform to study burst-laser-induced phenomena.

Shimada, Keitaro↗

Simultaneous 10 kHz three-dimensional CH 2 O and tomographic PIV measurements in a lifted partially-premixed jet flame

High-speed, three-dimensional (3D) scalar-velocity field measurements are demonstrated in a lifted partially-premixed dimethyl-ether/air jet flame using simultaneous laser-induced fluorescence (LIF) of formaldehyde (CH 2 O) and tomographic particle image velocimetry (TPIV). The 3D LIF measurements are performed by raster scanning the laser beam from a 100 kHz pulse-burst laser across the probe volume using an acousto-optic deflector. The volumetric reconstruction of the LIF signal from ten parallel planes provides quasi-instantaneous 3D LIF measurements that are synchronized with 10 kHz TPIV measurements. Here, the temporally resolved CH 2 O-LIF and velocity field data are used to analyze Lagrangian particle trajectories and displacement speeds at the base of the lifted flame. The particle trajectories reveal flow structures that are difficult to observe in an Eulerian reference frame. Positive and negative displacement speeds are observed at the CH 2 O-LIF surfaces at the inner and outer regions of the jet flame with a maximum displacement speed of approximately eight times the laminar flame speed of a stoichiometric dimethyl-ether/air mixture. The observations in present study support formation of lean premixed flames near the flame base whose role in flame stabilization should be investigated in more detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved particle image velocimetry

Time-resolved particle image velocimetry (TR-PIV) has become widespread in fluid dynamics. Essentially a velocity field movie, the dynamic content provides temporal as well as spatial information, in contrast to conventional PIV offering only statistical ensembles of flow quantities. From these time series arise further analyses such as accelerometry, space-time correlations, frequency spectra of turbulence including spatial variability, and derivation of pressure fields and forces. The historical development of TR-PIV is chronicled, culminating in an assessment of the current state of technology in high-repetition-rate lasers and high-speed cameras. Commercialization of pulse-burst lasers has expanded TR-PIV into more flows, including the compressible regime, and has achieved MHz rates. Particle response times and peak locking during image interrogation require attention but generally are not impediments to success. Accuracy considerations are discussed, including the risks of noise and aliasing in spectral content. Oversampled TR-PIV measurements allow use of multi-frame image interrogation methods, which improve the precision of the correlation and raise the velocity dynamic range of PIV. In combination with volumetric methods and data assimilation, a full four-dimensional description of a flow is not only achievable but becoming standardized. Lastly, a survey of exemplary applications is followed by a few predictions concerning the future of TR-PIV.

47 OTHER INSTRUMENTATION↗

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry↗

High-speed volumetric imaging of formaldehyde in a lifted turbulent jet flame using an acousto-optic deflector

The development of high-speed volumetric laser-induced fluorescence measurements of formaldehyde (CH 2 O-LIF) using a pulse-burst laser operated at a repetition rate of 100 kHz is presented here. A novel laser scanning system employing an acousto-optic deflector (AOD) enables quasi-4D CH 2 O-LIF imaging at a scan frequency of 10 kHz. The diagnostic capability of time-resolved volumetric imaging is demonstrated in a partially premixed DME/air lifted turbulent jet flame near the flame base. Simultaneous imaging of laser beam profiles is performed to account for the laser pulse energy fluctuation and laser sheet inhomogeneity. With the accurate registration of laser sheet positions, the volumetric reconstruction of CH 2 O-LIF signals is performed within a detection volume of 17.3 × 11.9 × 2.3 mm 3 with an average out-of-plane spatial resolution of 250μm. A surface detection algorithm with adaptive thresholding is used to determine the global maximum intensity gradient by calculating gradient percentiles. The flame topology characteristics are investigated by evaluating the 3D curvatures of CH 2 O surfaces. Curvatures calculated using 2D data systematically underestimate the full 3D curvature due to the lack of out-of-plane information. The inner surfaces near the turbulent fuel jet exhibit higher probabilities of large mean curvature than the outer surfaces. The saddle and cylindrical structures are dominant on both the inner and outer surfaces and the elliptic structures occur with lower probability. The results suggest that the damping of turbulent fluctuations by the temperature increase through the CH 2 O region reduces the curvature, but the local structure topology remains self-similar.

42 ENGINEERING↗

Pulse-burst spontaneous Raman thermometry of unsteady wave phenomena in a shock tube

A high-speed temperature diagnostic based on spontaneous Raman scattering (SRS) was demonstrated using a pulse-burst laser. The technique was first benchmarked in near-adiabatic H 2 -air flames at a data-acquisition rate of 5 kHz using an integrated pulse energy of 1.0 J per realization. Both the measurement precision and accuracy in the flame were within 3% of adiabatic predictions. Furthermore, this technique was then evaluated in a challenging free-piston shock tube environment operated at a shock Mach number of 3.5. SRS thermometry resolved the temperature in post-incident and post-reflected shock flows at a repetition rate of 3 kHz and clearly showed cooling associated with driver expansion waves. Collectively, this Letter represents a major advancement for SRS in impulsive facilities, which had previously been limited to steady state regions or single-shot acquisition.

47 OTHER INSTRUMENTATION↗

100-kHz Interferometric Rayleigh Scattering Flow Diagnostics at 266 nm

Interferometric Rayleigh scattering (IRS) is a laser-based technique capable of spatially and temporally resolved measurement of gas velocity and temperature in unseeded gaseous flows. In the present embodiment of the technique, IRS is performed at 266 nm for the first time. IRS at 266 nm is potentially much less susceptible to interferences from particles and other stray light sources. A pulse-burst laser and high-speed camera provided image rates of 100 kHz, allowing simultaneous space- and time-resolved measurement in high speed flow at multiple points along a line. The use of 266 nm excitation and detection is compared with prior work that used 532 nm. New experimental interferogram modelling and fitting techniques for single and multi-velocity-component IRS were demonstrated in a study of the spatial and temporal variation of the flow along a line through a supersonic jet. Single component velocity and temperature measurements using 266 nm were successfully made and compared with prior 532 nm results. Two-component velocity measurements at 266 nm, using the reflected image method, were compared to single-component measurements.

Andrew D Cutler↗

On the Use of Liquid Nitrogen Droplets as Flow Tracers in Cryogenic Flow Facilities at NASA Langley Research Center

The injection of liquid nitrogen droplets to cool the gas temperature in cryogenic wind tunnels is discussed as a method of natural seeding for velocimetry-focused, particle-based, laser diagnostics. Historical observations and issues with seeding are presented for both ground-test facilities of interest in this work at NASA Langley: the 0.3-m Transonic Cryogenic Wind Tunnel (TCT) and the National Transonic Facility (NTF). Recent observations of natural seeding with a Rayleigh scattering instrument are presented in the two facilities, which motivated the purposeful use of a pulse-burst laser system to observe the particles directly with a sequentially operated laser sheet for the first time. Time-resolved image sequences of unevaporated liquid nitrogen droplets were readily acquired for tunnel total temperatures of 200 K and below. The preliminary results promote a discussion on the fitness of these natural particles as flow tracers for either a particle image velocimetry or a particle tracking velocimetry instrument in these high-Reynolds-number facilities.

cryogenic wind tunnels↗

Image processing methods for Rayleigh scattering measurements of diesel spray mixing at high repetition rate

This work describes the diagnostic implementation and image processing methods to quantitatively measure diesel spray mixing injected into a high-pressure, high-temperature environment. We used a high-repetition-rate pulse-burst laser developed in-house, a high-speed CMOS camera, and optimized the optical configuration to capture Rayleigh scattering images of the vaporized fuel jets inside a constant volume chamber. The experimental installation was modified to reduce reflections and flare levels to maximize the images’ signal-to-noise ratios by anti-reflection coatings on windows and surfaces, as well as series of optical baffles. Because of the specificities of the high-speed system, several image processing techniques had to be developed and implemented to provide quantitative fuel concentration measurements. We find that these methods involve various correction procedures such as camera linearity, laser intensity fluctuation, dynamic background flare, as well as beam-steering effects. Image inpainting was also applied to correct the Rayleigh scattering signal from large scatterers (e.g. particulates). The experiments demonstrate that applying planar laser Rayleigh scattering at high repetition rate to quantitatively resolve the mixing of fuel and ambient gases in diesel jets is challenging, but possible. The thorough analysis of the experimental uncertainty and comparisons to past data prove that such measurements can be accurate, whilst providing valuable information about the mixing processes of high-pressure diesel jets.

47 OTHER INSTRUMENTATION↗

Megahertz-rate shock-wave distortion cancellation via phase conjugate digital in-line holography

Abstract Holography is a powerful tool for three-dimensional imaging. However, in explosive, supersonic, hypersonic, cavitating, or ionizing environments, shock-waves and density gradients impart phase distortions that obscure objects in the field-of-view. Capturing time-resolved information in these environments also requires ultra-high-speed acquisition. To reduce phase distortions and increase imaging rates, we introduce an ultra-high-speed phase conjugate digital in-line holography (PCDIH) technique. In this concept, a coherent beam passes through the shock-wave distortion, reflects off a phase conjugate mirror, and propagates back through the shock-wave, thereby minimizing imaging distortions from phase delays. By implementing the method using a pulse-burst laser setup at up to 5 million-frames-per-second, time-resolved holograms of ultra-fast events are now possible. This technique is applied for holographic imaging through laser-spark plasma-generated shock-waves and to enable three-dimensional tracking of explosively generated hypersonic fragments. Simulations further advance our understanding of physical processes and experiments demonstrate ultra-high-speed PCDIH techniques for capturing dynamics.

Science & Technology - Other Topics↗

Developing a high-speed terahertz imaging system based on parametric upconversion imaging for penetrative sensing

Imaging using THz waves has been a promising option for penetrative measurements in environments that are opaque to visible wavelengths. However, available THz imaging systems have been limited to relatively low frame rates and cannot be applied to study fast dynamics. This work explores the use of upconversion imaging techniques based on nonlinear optics to enable wavelength-flexible high frame rate THz imaging. UpConversion Imaging (UCI) uses nonlinear conversion techniques to shift the THz wavelengths carrying a target image to shorter visible or near-IR wavelengths that can be detected by available high-speed cameras. This report describes the analysis methodology used to design a prototype high-rate THz UCI system and gives a detailed explanations of the design choices that were made. The design uses a high-rate pulse-burst laser system to pump both THz generation and THz upconversion detection, allowing for scaling to acquisition rates in excess of 10 kHz. The design of the prototype system described in this report has been completed and all necessary materials have been procured. Assembly and characterization testing is on-going at the submission of this report. This report proposes future directions for work on high-rate THz UCI and potential applications of future systems.

47 OTHER INSTRUMENTATION↗

NO PLIF Imaging in the CUBRC 48 Inch Shock Tunnel

Nitric Oxide Planar Laser-Induced Fluorescence (NO PLIF) imaging is demonstrated at a 10 kHz repetition rate in the Calspan-University at Buffalo Research Center s (CUBRC) 48-inch Mach 9 hypervelocity shock tunnel using a pulse burst laser-based high frame rate imaging system. Sequences of up to ten images are obtained internal to a supersonic combustor model, located within the shock tunnel, during a single approx.10-millisecond duration run of the ground test facility. This represents over an order of magnitude improvement in data rate from previous PLIF-based diagnostic approaches. Comparison with a preliminary CFD simulation shows good overall qualitative agreement between the prediction of the mean NO density field and the observed PLIF image intensity, averaged over forty individual images obtained during several facility runs.

Jiang, N.↗

Space Borne Event Timer

The Space Borne Event Timer is a part of the NASA laser ranging system that is intended to operate aboard the Space Shuttle orbiting over California. The object is to measure, by laser ranging, the earth movement along the San Andreas fault and possibly forecast future earthquakes. A number of cube reflector targets will be placed along both sides of the fault. The ranging system aboard the Space Shuttle will fire a burst of laser pulses at each target and detect the reflected light. Time differences between pulses from the two sides of the fault will indicate earth displacements. The Space Borne Event Timer is a CAMAC compatible system that provides extremely accurate timing data and controls the operation of the ranging system. For each event the time is given in 19.53 increments from the instant of firing the laser to the instant the reflected light is received back, within a range of 130 days.

Turko, B.↗

Generation of multiple attosecond sub-bursts in femtosecond pulse trains by long-wavelength driving lasers

High-order harmonics generated by a long intense femtosecond laser are known experimentally to create attosecond pulse trains (APTs). In the time domain, an APT consists of a sequence of sharp attosecond bursts that are equally separated by each half optical cycle. Here, in this work, we show that such well-known features can be modified when a longer wavelength driving laser is used. From our simulations, we show that multiple shorter attosecond sub-bursts exist in the femtosecond pulse train within each half optical cycle and the duration of each sub-burst scales approximately as $λ^{–2}_0$ with the driving laser wavelength λ 0 . We show that such sub-bursts can be found using quantitative rescattering model for harmonics generated from a single atom, and their origin is due to the interference of the quantum orbits from first two returns of the recombining electron. We further show that such sub-bursts can be phase matched under proper laser focusing condition and the position of the gas cell, thus, such new features should be observable experimentally.

47 OTHER INSTRUMENTATION↗