Analysis of continuous pulse height spectra
Continuous differential energy pulse height spectra reduction to photon upper atmospheric spectra
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Continuous differential energy pulse height spectra reduction to photon upper atmospheric spectra
Purpose: Pulse height spectra (PHS) have been used to determine the Swank factor of a scintillator by measuring fluctuations in its light output per x-ray interaction. The Swank factor and x-ray quantum efficiency of a scintillator define the upper limit to its imaging performance, i.e. DQE(0). The Swank factor below the K-edge is dominated by optical properties, i.e. variations in light escape efficiency from different depths of interaction, denoted e(z). These variations can be optimized to improve tradeoffs in x-ray absorption, light yield, and spatial resolution. This work develops a quantitative model for interpreting measured PHS, and estimating e(z) on an absolute scale. The method is used to investigate segmented ceramic GOS scintillators used in multi-slice CT detectors. Methods: PHS of a ceramic GOS plate (1 mm thickness) and segmented GOS array (1.4 mm thick) were measured at 46 keV. Signal and noise propagation through x-ray conversion gain, light escape, detection by a photomultiplier tube and dynode amplification were modeled using a cascade of stochastic gain stages. PHS were calculated with these expressions and compared to measurements. Light escape parameters were varied until modeled PHS agreed with measurements. The resulting estimates of e(z) were used to calculate PHS without measurement noise to determine the inherent Swank factor. Results: The variation in e(z) was 67.2–89.7% in the plate and 40.2–70.8% in the segmented sample, corresponding to conversion gains of 28.6–38.1 keV{sup −1} and 17.1–30.1 keV{sup −1}, respectively. The inherent Swank factors of the plate and segmented sample were 0.99 and 0.95, respectively. Conclusion: The high light escape efficiency in the ceramic GOS samples yields high Swank factors and DQE(0) in CT applications. The PHS model allows the intrinsic optical properties of scintillators to be deduced from PHS measurements, thus it provides new insights for evaluating the imaging performance of segmented ceramic GOS scintillators.
Linear least-square method resolves complex pulse height spectra, allowing for calculation of relative intensity, of statistical variance based on counting statistics of the correlation between library components, and of the goodness-of-fit chi square. Some applications are to gamma-ray, X ray, and charged-particle spectroscopy.
The estimation of the signal location and intensity of a peak in a pulse height spectrum is important for X- ray and γ-ray spectroscopy, charged-particle spectrometry, liquid chromatography, and many other subfields. However, both the ‘‘centroid’’ and ‘‘signal intensity’’ of a peak in a pulse-height spectrum are ill-defined quantities and different methods of analysis will yield different numerical results. Here, we apply three methods of analysis. Method A is based on simple count summation and is likely the technique most frequently applied in practice. The analysis is straightforward and fast, and does not involve any statistical modeling. We find that it provides reliable results only for high signal-to-noise data, but has severe limitations in all other cases. Method B employs a Bayesian model to extract signal counts and centroid from the measured total and background counts. The resulting values are derived from the respective posteriors and, therefore, have a rigorous statistical meaning. The method makes no assumptions about the peak shape. It yields reliable and relatively small centroid uncertainties. However, it provides relatively large signal count uncertainties. Method C makes a strong assumption regarding the peak shape by fitting a Gaussian function to the data. Furthermore, the fit is based again on a Bayesian model. Although Method C requires careful consideration of the Gaussian width (usually given by the detector resolution) used in the fitting, it provides reliable values and relatively small uncertainties both for the signal counts and the centroid.
The method of inferring photon spectra from an analysis of the measured pulse-height spectrum is considered along with the spectrum shape and its variation energy. The case is examined where photoelastic absorption predominates, and Compton scattering and pair production are negligible. The analytic method for obtaining the elemental composition from the observed lunar surface spectrum is described, and theoretical and calculated weight fraction fluxes for average lunar composition are tabulated.
On-line digital analysis of geochemical spectra data
We report the results of a ROSAT pointed study of 4 BY Dra systems. Good quality pulse-height spectra are available from all four systems. Except for a required interstellar absorption component in HD 319139, the four systems have remarkably similar x-ray spectra; the two systems BD +22deg.669 and BD +23deg.635 look virtually identical in x rays. Analysis of the 4 x-ray spectra reveals that, in all cases, a single-temperature hot plasma (RS or Mewe) spectra is inadequate to fit the data, and two temperatures are required. We present examples of fitted pulse-height spectra and chi squared contours in kT(sub 1)-kT(sub 2) space.
Measured pulse height spectra for photon spectra and instrumental error reduction
A neutron camera with liquid scintillator detectors is used in MAST to measure the neutron emissivity from D(d,n){sup 3}He reactions along collimated lines of sight. In this work, the measured recoil proton pulse height spectra generated in the detectors by the incident neutrons is modelled taking into account the energy spectrum of the generated neutrons, their spatial distribution and transport to the detectors as well as the detector's response function. The contribution of scattered neutrons to the pulse height spectrum is also modelled. Good agreement is found between the experimental data and the simulations. Examples are given showing the sensitivity of the recoil proton pulse height spectra to different observation angles with respect the neutral beam injection and the plasma rotation direction.
Our paper presents experimental and computational techniques implemented for 4 He gas scintillation detectorsfor inducedfission neutron detection. Fission neutrons are produced when natural uranium samples are activelyinterrogated by 2.45 MeV deuterium-deuterium fusion reaction neutrons. Fission neutrons of energies greaterthan 2.45 MeV can be distinguished by their different scintillation pulse height spectra since 4 He detectorsretain incident fast neutron energy information. To enable the preferential detection of fast neutrons up to10 MeV and suppress low-energy event counts, the detector photomultiplier gain is lowered and triggerthreshold is increased. Pile-up and other unreliable events due to the interrogating neutronflux and backgroundradiation arefiltered out prior to the evaluation of pulse height spectra. With these problem-specific calibrationsand data processing, the 4 He detector's accuracy at discriminatingfission neutrons up to 10 MeV is improvedand verified with 252 Cf spontaneousfission neutrons. Given the 4 He detector's ability to differentiate fastneutron sources, this proof-of-concept active-interrogation measurement demonstrates the potential of specialnuclear materials detection using a 4 He fast neutron detection system.
In this study, LiAlO2 crystals doped with rare-earth elements and Ti were produced by the CZ method and spectroscopic and neutron detection properties were investigated. Photoluminescence revealed no clear luminescent activation of LiAlO2 by the rare-earth dopants though some interesting luminescence was observed from secondary phases within the crystal. Gamma-ray pulse height spectra collected using a 137Cs source exhibited only a Compton edge for the crystals. Neutron modeling using Monte Carlo N-Particle Transport Code revealed most neutrons used in the detection setup are thermalized, and while using natural lithium in the crystal growth, which contains 7.6 % 6Li, a 10 mm Ø by 10 mm sample of LiAlO2 has a 70.7 % intrinsic thermal neutron capture efficiency. Furthermore, the pulse height spectra collected using a 241Am-Be neutron source demonstrated a distinct neutron peak.
X-ray pulse height spectra of the most active cool stars in the Hyades cluster obtained with the Einstein IPC cannot be satisfactorily fitted using isothermal thin plasma emission models. Addition of a second isothermal component provides acceptable fits. However, a more physically meaningful set of coronal parameters is provided by models which consist of an ensemble of loops wih a single maximum temperature, but with the temperature distribution within the loop determined by loop physics. Such models have been successfully fitted to the IPC pulse height spectra. Constraints on loop parameters are discussed for the F-G dwarfs BD + 14 deg 693, BD + 14 deg 690, BD + 15 deg 640, and 71 Tau. Models with a large variation of loop cross section from base to top do not fit the data. A consistent physical description is an ensemble of small high-pressure loops of similar maximum temperature which dominate the coronal X-ray spectrum.
Pulse pile-up in pulse-height energy analyzers increases when the incident rate of pulses increases relative to the inverse of the dead time per pulse of the detection system. Changes in the observed energy distributions with incident rate and detector-electronics-formed pulse shape then occur. Here, we focus on weak high energy tails in X-ray spectra, important for measurements on partially ionized, warm (50–500 eV average electron energy), pure hydrogen plasma. A first-principles two-photon pulse-pile-up model is derived specific to trapezoidal-shaped pulses; quantitative agreement is found between the measurements and the model’s predictions. The model is then used to diagnose pulse-pile-up tail artifacts and mitigate them in relatively low count-rate spectra.
Calibration techniques for a medium energy gamma ray telescope are described. Gain calibration using Compton edge spectra involves comparisons of pulse height spectra with spectra simulated by a Monte Carlo computer code which includes Compton scattering and pair production, plural scattering and variable energy resolution, and cell size. The telescope considered comprises 56 cells of liquid scintillator in four size groups, with a total liquid volume of 325 l; each cell has its own photomultiplier tube. Energy and angular resolutions and the PMT gain calibration procedure are verified with double scatter data for monoenergetic gamma rays at a known location. Detection probabilities for any cell combination in the two telescope arrays are calculated per steradian as a function of the scattering for a number of different energies with a Van de Graaff accelerator.
The addition of 2 % of selenium in CdTe and CdZnTe (CZT) exhibited an additional acceptor-bound exciton in photoluminescence (PL). From the PL and inductively coupled plasma mass spectrometer (ICP/MS) analyses, the additional acceptor-bound exciton emission is associated with a Cu impurity in the relatively low-purity (5N) precursor CdSe starting material. Additionally, thermal quenching of the acceptor/donor bound exciton emissions do not require a shift to any higher excited states or to the free exciton state. ICP/MS analysis also showed a higher concentration of Sn in CdZnTeSe (CZTS) compared to CdTe and CZT which is known to form a deep level trap at around E C – 0.83 eV. The trapping and de-trapping times indicate that the Sn-related deep trap acts as an electron trapping center. The relatively low electron mobility-lifetime product of CZTS might be correlated with the concentration of Sn in the impure CdSe material. Pulse height spectra using an Eu-152 gamma-ray source was taken for a 2-mm-thick planar CZTS detector. The spectra clearly showed all the expected gamma peaks with energy lower than 344.3 keV.
CdZnTe (CZT) detectors with more than 10% zinc content did not show a remarkable improvement in the detector performance due to the additional defects introduced by the higher zinc content. However, recent research showed that the formation of defects was suppressed effectively by adding a small amount of selenium (2%) in CZT. On this basis, we attempted to enhance the detector performance through bandgap engineering by increasing the zinc content up to 25 %, while adding 2 % of selenium. Multiple CdZnTeSe (CZTS) ingots with Zn = 10, 12.5, 15, 20 and 25%, while fixing the Se composition at 2%, were grown by the Bridgman method. The bandgap of CZTS for the different Zn and Se contents was analyzed and then equations for predicting the bandgap for other alloy compositions were introduced. Furthermore, the crystallinity of CZTS was evaluated by photoluminescence measurements. The pulse height spectra for Am-241 and Co-57 sources were used to evaluate the detector performance for the CZTS samples.
When pulse-height spectra are measured by a nuclear detection system at high counting rates, the probability that two or more pulses will arrive within the resolving time of the system is significant. This phenomenon, pulse pile-up, distorts the pulse-height spectrum and must be considered in the interpretation of spectra taken at high counting rates. A computational technique for the simulation of pile-up is developed. The model is examined in the three regimes where (1) the time between pulses is long compared to the detector-system resolving time, (2) the time between pulses is comparable to the resolving time, and (3) many pulses occur within the resolving time. The technique is used to model the solar hard X-ray experiment on the OSO-7 satellite; comparison of the model with data taken during three large flares shows excellent agreement. The paper also describes rule-of-thumb tests for pile-up and identifies the important detector design factors for minimizing pile-up, i.e., thick entrance windows and short resolving times in the system electronics.
The first step in the analysis of gamma ray energy loss spectra is their conversion to differential energy and differential angular photon spectra. This conversion can be carried out if the detector response and the background are both known. Once these parameters are known, there are many techniques that can be used to convert pulse height spectra to photon spectra. These techniques are discussed and background problems are considered. Emphasis is placed on the analysis of energy loss spectra in the lower gamma ray energy domain. Problems of transportations from pulse height to photon space are most complex in this domain and the methods shown illustrate many of the problems which arise in the general analysis of energy loss spectra.