Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse jet mixing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Simple Criterion to Estimate Performance of Pulse Jet Mixed Vessels

Pulse jet mixed process vessels comprise a key element of the U.S. Department of Energy’s strategy to process millions of gallons of legacy nuclear waste slurries. Slurry suctioned into a pulse jet mixer (PJM) tube at the end of one pulse is pneumatically driven from the PJM toward the bottom of the vessel at the beginning of the next pulse, forming a jet. The jet front traverses the distance from nozzle outlet to the bottom of the vessel and spreads out radially. Varying numbers of PJMs are typically arranged in a ring configuration within the vessel at a selected radius and operated concurrently. Centrally directed radial flows from neighboring jets collide to create a central upwell that elevates the solids in the center of the vessel when the PJM tubes expel their contents. An essential goal of PJM operation is to elevate solids to the liquid surface to minimize stratification. Solids stratification may adversely affect throughput of the waste processing plant. Unacceptably high slurry densities at the base of the vessel may plug the pipeline through which the slurry exits the vessel. Additionally, chemical reactions required for processing may not achieve complete conversion. To avoid these conditions, a means of predicting the elevation to which the solids rise in the central upwell that can be used during vessel design remains essential. In this paper we present a simple criterion to evaluate the extent of solids elevation achieved by a turbulent upwell jet. The criterion asserts that at any location in the central upwell the local velocity must be in excess of a cutoff velocity to remain turbulent. We find that local velocities in excess of 0.6 m/s are necessary for turbulent jet flow through both Newtonian and yield stress slurries. By coupling this criterion with the free jet velocity equation relating the local velocity to elevation in the central upwell, we estimate the elevation at which turbulence fails, and consequently the elevation at which the upwell fails to further lift the slurry. Comparing this elevation to the vessel fill level predicts whether the jet flow will achieve the full vertical extent of the vessel at the center. This simple local-velocity criterion determines a minimum PJM nozzle velocity at which the full vertical extent of the central upwell in PJM vessels will be turbulent. The criterion determines a minimum because flow in regions peripheral to the central upwelling jet may not be turbulent, even when the center of the vessel in the upwell is turbulent, if the jet pulse duration is too short. The local-velocity criterion ensures only that there is sufficient wherewithal for the turbulent jet flow to drive solids to the surface in the center of the vessel in the central upwell.

mixing↗

Scoping Study of Airlift Circulation Technologies for Supplemental Mixing in Pulse Jet Mixed Vessels

At the request of the U.S. Department of Energy Office of River Protection, Pacific Northwest National Laboratory (PNNL) conducted a scoping study to investigate supplemental technologies for supplying vertical fluid motion and enhanced mixing in Waste Treatment and Immobilization Plant (WTP) vessels designed for high solids processing. The study assumed that the pulse jet mixers adequately mix and shear the bottom portion of a vessel. Given that, the primary function of a supplemental technology should be to provide mixing and shearing in the upper region of a vessel. The objective of the study was to recommend a mixing technology and configuration that could be implemented in the 8-ft test vessel located at Mid-Columbia Engineering (MCE). Several mixing technologies, primarily airlift circulator (ALC) systems, were evaluated in the study. This technical report contains a review of ALC technologies, a description of the PNNL testing and accompanying results, and recommended features of an ALC system for further study.

airlift circulator↗

SCALED EXPERIMENTS EVALUATING PULSE JET MIXING OF SLURRIES

Pulse jet mixing (PJM) tests with noncohesive solids in Newtonian liquid were conducted at three geometric scales to support the design of mixing systems for the Hanford Waste Treatment and Immobilization Plant. The test data will be used to develop mixing models. The models predict the cloud height (the height to which solids will be lifted by the PJM action) and the critical suspension velocity (the minimum velocity needed to ensure all solids have been lifted from the floor. From the cloud height estimate, the concentration of solids near the vessel floor and the minimum velocity predicted to lift solids can be calculated. The test objective was to observe the influence of vertically downward-directed jets on noncohesive solids in a series of scaled tanks with several bottom shapes. The test tanks and bottom shapes included small-and large-scale tanks with elliptical bottoms, a mid-scale tank with a spherical bottom, and a large-scale tank with an F&D bottom. During testing, the downward-directed jets were operated in either a steady flow condition or a pulsed (periodic) flow condition. The mobilization of the solids resulting from the jets was evaluated based on: the motion/agitation of the particulate on the tank floor and the elevation the solids reach within the tank; the height the solids material reaches in the tank is referred to as the cloud height (HC).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A STATISTICAL INTELLIGENCE (STI) APPROACH TO DISCOVERING SPURIOUS CORRELATION IN A PHYSICAL MODEL AND RESOLVING THE PROBLEM WITH AN EXAMPLE OF DESIGNING A PULSE JET MIXING SYSTEM AT HANFORD

Pulse jet mixing tests were conducted to support the design of mixing systems for the Hanford Waste Treatment and Immobilization Plant. A physical approach (based on hydro-dynamic behavior) and two semi-empirical (SE) approaches were applied to the data to develop models for predicting two response variables (critical-suspension velocity and cloud height). Tests were conducted at three geometric scales using multiple noncohesive simulants and levels of possibly influential factors. The physical modeling approach based on hydro- dynamic behavior was first attempted, but this approach can yield models with spurious correlation. To overcome this dilemma, two semi-empirical (SE) models were developed by generalizing the form of the physical model using dimensional and/or nondimensional (ND) variables. The results of applying statistical intelligence (STI) tools to resolve the spurious correlation problem via fitting the physical and SE models are presented and compared. Considering goodness-of-fit, prediction performance, spurious correlation, and the need to extrapolate, the SE models based on ND variables are recommended.

multiple regression↗

IN SITU MEASUREMENT TECHNIQUES FOR CHARACTERIZING PULSE JET MIXING OF SLURRIES

Metrics to characterize mixing are the just suspended velocity (UJS) and the cloud height (HC). Two ultrasonic instruments to characterize pulse jet mixing of slurries were developed and deployed to measure related metrics: the thickness of the settled bed and the concentration within the cloud as a function of elevation [C(Z)]. Ultrasonic Doppler velocimetry was used to measure the thickness of the bed of nonmoving particles (the settled solids layer). During pulse jet mixing at the critical suspension velocity (UCS) the settled solids layer thickness approached zero at the end of the jet pulse. The UCS is related to the just suspended velocity (UJS) for steady mixing. Ultrasonic attenuation was used to measure the suspended solids concentration at locations in the vessel to determine the concentration profile as a function of radial position and elevation. The concentration profile provided data inside the cloud and complemented the visual measurement of the cloud height (HC). The UDV and the ultrasonic concentration probe data are used to evaluate the desired metrics based on relative measurements. The relative measurements are correlated with results obtained from a series of working standards created for each slurry, and used to develop correlations specific to each slurry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MULTIPHASE FLOW CONCENTRATION CHARACTERIZATION IN SLURRIES DURING PULSE JET MIXING

Obtaining real-time, in situ slurry concentration measurements during unsteady mixing can provide increased understanding into mixer performance. During tests of an operating pulse jet mixing system, an ultrasonic attenuation sensor was inserted into a mixing vessel to measure the slurry concentration during unsteady mixing in real time. Pulse jet mixing tests to suspend noncohesive solids in Newtonian liquid were conducted at three geometric scales. To understand the solids suspension process and resulting solids distribution, the concentration of solids in the cloud was measured at various elevations and radial positions during the pulse jet mixer cycle. This paper presents transient concentration data obtained at three scales at the tank center to provide insight into pulse jet mixer performance.

concentration profile↗

Pulse Jet Mixing Tests With Noncohesive Solids (Revised)

This report summarizes results from pulse jet mixing (PJM) tests with noncohesive solids in Newtonian liquid. The tests were conducted during FY 2007 and 2008 to support the design of mixing systems for the Hanford Waste Treatment and Immobilization Plant (WTP). Tests were conducted at three geometric scales using noncohesive simulants, and the test data were used to develop models predicting two measures of mixing performance for full-scale WTP vessels. The models predict the cloud height (the height to which solids will be lifted by the PJM action) and the critical suspension velocity (the minimum velocity needed to ensure all solids are suspended off the floor, though not fully mixed). From the cloud height, the concentration of solids at the pump inlet can be estimated. The predicted critical suspension velocity for lifting all solids is not precisely the same as the mixing requirement for 'disturbing' a sufficient volume of solids, but the values will be similar and closely related. These predictive models were successfully benchmarked against larger scale tests and compared well with results from computational fluid dynamics simulations. The application of the models to assess mixing in WTP vessels is illustrated in examples for 13 distinct designs and selected operational conditions. The values selected for these examples are not final; thus, the estimates of performance should not be interpreted as final conclusions of design adequacy or inadequacy. However, this work does reveal that several vessels may require adjustments to design, operating features, or waste feed properties to ensure confidence in operation. The models described in this report will prove to be valuable engineering tools to evaluate options as designs are finalized for the WTP. Revision 1 refines data sets used for model development and summarizes models developed since the completion of Revision 0.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concentration Distributions during Pulse Jet Mixing

Obtaining real-time, in situ slurry concentration measurements during unsteady mixing can provide increased understanding into mixer performance. During recent tests an ultrasonic attenuation sensor was inserted into a mixing vessel to measure the slurry concentration during unsteady mixing in real time during pulse jet mixer operation. These pulse jet mixing tests to suspend noncohesive solids in Newtonian liquid were conducted at three geometric scales. To understand the solids suspension process and resulting solids distribution, the concentration of solids in the cloud was measured at various elevations and radial positions during the pulse jet mixer cycle. In the largest scale vessel, concentration profiles were measured at three radial locations: r = 0, 0.5 and 0.9 R where R is the vessel radius. These radial concentration data are being analyzed to provide a model for predicting concentration as a function of elevation. This paper describes pulse jet mixer operation, provides a description of the concentration probe, and presents transient concentration data obtained at three radial positions: in the vessel center (O R), midway between the center and the wall (0.5 R) and near the vessel wall (0.9 R) through out the pulse to provide insight into pulse jet mixer performance.

42 ENGINEERING↗

Estimating Scaled Cloud Height in Pulse Jet Mixed Vessels

To suspend and mix radioactive slurries without pumps or impellers, the performance of pulsed jet mixed vessels has been investigated. The slurry in the pulse tubes is expelled impinging upon the vessel floor and lifting solids to a “cloud height” in a cyclic process. Experiments measuring cloud height for a variety of waste simulants have been conducted for vessel configurations that varied vessel diameter, fill height and pulse tube number, volume, and nozzle diameter. The elevation to which suspended particles rise is termed the cloud height and derives from a balance between the fluid forces of the jet and the gravitational forces acting on the particle ensemble. Here we use scaling to estimate the cloud height based on conservation of mass and momentum and jet similarity. We find that the cloud height varies with the nozzle exit velocity to the 2/3 power in agreement with observations.

cloud height, effective cleaning radius, effective↗

Pulse Jet Mixing Tests With Noncohesive Solids

This report summarizes results from pulse jet mixing (PJM) tests with noncohesive solids in Newtonian liquid conducted during FY 2007 and 2008 to support the design of mixing systems for the Hanford Waste Treatment and Immobilization Plant (WTP). Tests were conducted at three geometric scales using noncohesive simulants. The test data were used to independently develop mixing models that can be used to predict full-scale WTP vessel performance and to rate current WTP mixing system designs against two specific performance requirements. One requirement is to ensure that all solids have been disturbed during the mixing action, which is important to release gas from the solids. The second requirement is to maintain a suspended solids concentration below 20 weight percent at the pump inlet. The models predict the height to which solids will be lifted by the PJM action, and the minimum velocity needed to ensure all solids have been lifted from the floor. From the cloud height estimate we can calculate the concentration of solids at the pump inlet. The velocity needed to lift the solids is slightly more demanding than "disturbing" the solids, and is used as a surrogate for this metric. We applied the models to assess WTP mixing vessel performance with respect to the two perform¬ance requirements. Each mixing vessel was evaluated against these two criteria for two defined waste conditions. One of the wastes was defined by design limits and one was derived from Hanford waste characterization reports. The assessment predicts that three vessel types will satisfy the design criteria for all conditions evaluated. Seven vessel types will not satisfy the performance criteria used for any of the conditions evaluated. The remaining three vessel types provide varying assessments when the different particle characteristics are evaluated. The assessment predicts that three vessel types will satisfy the design criteria for all conditions evaluated. Seven vessel types will not satisfy the performance criteria used for any of the conditions evaluated. The remaining three vessel types provide varying assessments when the different particle characteristics are evaluated. The HLP-022 vessel was also evaluated using 12 m/s pulse jet velocity with 6-in. nozzles, and this design also did not satisfy the criteria for all of the conditions evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implications of Upwells as Hydrodynamic Jets in a Pulse Jet Mixed System

This report evaluates the physics of the upwell flow in pulse jet mixed systems in the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Although the initial downward flow and radial flow from jets characteristic of pulse jet mixers (PJMs) has been analyzed, the upwells have received considerably less attention despite having significant implications for vessel mixing. Do the upwells behave like jets? How do the upwells scale? When will the central upwell break through? What proportion of the vessel is blended by the upwells themselves? Indeed, how the physics of the central upwell is affected by multiple PJMs (e.g., six in the proposed mixing vessels), non-Newtonian rheology, and significant multicomponent solids loadings remain unexplored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implications of Upwells as Hydrodynamic Jets in a Pulse Jet Mixed System

This report evaluates the physics of the upwell flow in pulse jet mixed systems in the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Although the initial downward flow and radial flow from pulse jet mixers (PJMs) has been analyzed in some detail, the upwells have received considerably less attention despite having significant implications for vessel mixing. Do the upwells behave like jets? How do the upwells scale? When will the central upwell breakthrough? What proportion of the vessel is blended by the upwells themselves? Indeed, how the physics of the central upwell is affected by multiple PJMs (e.g., six in the proposed mixing vessels), non-Newtonian rheology, and significant multicomponent solids loadings remain unexplored. The central upwell must satisfy several criteria to be considered a free jet. First, it must travel for several diameters in a nearly constant direction. Second, its velocity must decay with the inverse of elevation. Third, it should have an approximately Gaussian profile. Fourth, the influence of surface or body forces must be negligible. A combination of historical data in a 12.75 ft test vessel, newly analyzed data from the 8 ft test vessel, and conservation of momentum arguments derived specifically for PJM operating conditions demonstrate that the central upwell satisfies these criteria where vigorous breakthrough is achieved. An essential feature of scaling from one vessel to the next is the requirement that the underlying physics does not change adversely. One may have confidence in scaling if (1) correlations and formulas capture the relevant physics; (2) the underlying physics does not change from the conditions under which it was developed to the conditions of interest; (3) all factors relevant to scaling have been incorporated, including flow, material, and geometric considerations; and (4) the uncertainty in the relationships is sufficiently narrow to meet required specifications. Although the central upwell satisfies these criteria when vigorous breakthrough is achieved, not all available data follow the free jet profile for the central upwell, particularly at lower nozzle velocities. Alternative flow regimes are considered and new models for cloud height, “cavern height,” and the rate of jet penetration (jet celerity) are benchmarked against data to anchor scaling analyses. This analytical modeling effort to provide a technical basis for scaling PJM mixed vessels has significant implications for vessel mixing, because jet physics underlies “cavern” height, cloud height, and the volume of mixing considerations. A new four-parameter cloud height model compares favorably to experimental results. This model is predictive of breakthrough in 8 ft vessel tests with the two-part simulant. Analysis of the upwell in the presence of yield stresses finds evidence of expanding turbulent jets, confined turbulent jets, and confined laminar flows. For each, the critical elevation at which jet momentum depletes is predicted, which compare favorably to experimental cavern height data. Partially coupled momentum and energy balances suggest that these are limiting cases of a gradual transition from a turbulent expanding flow to a confined laminar flow. This analysis of the central upwell alone lays essential groundwork for complete analysis of mode three mixing (i.e., breakthrough with slow peripheral mixing). Consideration of jet celerity shows that the rate of jet penetration is a governing consideration in breakthrough to the surface. Estimates of the volume of mixing are presented. This analysis shows that flow along the vessel wall is sluggish such that the central upwell governs the volume of mixing. This analysis of the central upwell alone lays essential groundwork for complete analysis of mode three mixing and estimates of hydrogen release rates from first principles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress Update on the Waste Treatment and Immobilization Plant Pulse- Jet Mixed Vessel Testing Program - 16286

The Waste Treatment and Immobilization Plant (WTP) is designed to use cylindrical-shaped pulse-jet mixers in the black cell vessels to mix the radioactive waste during process operations. Pulse-jet mixers operate like large turkey basters, using air pressure to suck radioactive waste up into the mixer and eject it back into the vessel at high velocity. Using pulse-jet mixers for keeping waste in process vessels adequately mixed is one of the design features that ensures that there are no mechanical parts inside the black cells that would require maintenance. The WTP Project is conducting a testing program to ensure the pulse-jet mixed vessels can address three design and nuclear safety concerns: 1) pulse jet mixer controls, 2) hydrogen gas generation, and 3) the potential for inadvertent criticality in the vessels. The currently planned pulse-jet mixed vessel testing program is divided into three major test campaigns. The first campaign consists of testing to demonstrate pulse-jet mixed vessel control system design and operating concepts. The second test campaign consisted of informational testing of select prototypic PJM vessel features in a reduced scale facility. This testing informed decision making on selection of different mixing system configurations. This test campaign was completed in March 2015. The third test campaign is planned to test the complete functionality of a pulse-jet mixed vessel at full-scale using a prototype standardized high-solids vessel design. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating Transfer and Pumping of Slurries from Pulsed Jet Mixed Vessels

Due to gravity, solids in slurries will settle if density differences between the solids and liquid are positive (i.e., particle has a negative buoyant force) unless rheological properties and flow conditions are adequate to overcome the gravitational effects. The rate of settling depends on the force balance of the particle, which includes the surface forces associated with fluid rheology. Given the same fluid and solid properties, particles that are larger and denser tend to settle faster. When pumping slurry into a vessel at concentrations precluding hindered settling with insufficient mixing, particle and density distributions can result in preferential settling, creating stratification in the solids concentration within the vessel. For vessels with transfer line inlets located in the lower portion of the tank, the stratified solids concentration may be detrimental to the transfer system performance. Elevated concentrations of solids in the slurry entrained at the inlet to the transfer line can result in the effective viscosity or slurry bulk density exceeding the design limits of the pump. These conditions could result in plugging of the transfer line or onset of cavitation of the pumps because of excessive pressure drop. These conditions can be exacerbated with periodic inlet conditions existing at the transfer line inlet. Periodic conditions can result when vessel mixing is intermittent such as with pulsed jet mixers (PJM). The transfer line inlet conditions are impacted by the periodic nature of the PJM operations with respect to suspension of solids and their transport to the inlet of the transfer line. A scaling approach is presented, and corresponding test requirements are developed for assessing the prevention of plugging the pipeline. Line plugging mechanisms are addressed that do not include plugging due to steady-state high-density slurry entering the transfer line and reducing the net positive suction head available (NPSHA) at the pump inlet to below that required for pump operation. Items considered include the transition to reduced relative flow velocities, such that the critical pipe velocity for solids deposition, Ucd, is not maintained, and segregation of heavy solids during the transport. The recommended requirements to prevent plugging include: • Limits for viscosity and density for entrained slurry to prevent the pressure drop in the pipeline from exceeding pump capacity. • Limits for viscosity and density for entrained slurry to prevent the net positive suction head available (NPSHA) from falling below the net positive suction head required (NPSHR) for operating the pump. • Transfer line velocity and flow rate requirements to maintain solids in suspension, while avoiding line plugging that results from deposition of solids within the transfer line. This paper describes the development of the scaling and testing requirements to verify that proposed approaches for transfer and pump out are appropriately developed

periodic flow, mixing, pipeline plugging, scaling,↗

Scaling Theory for Pulsed Jet Mixed Vessels, Sparging, and Cyclic Feed Transport Systems for Slurries

This document is a previously unpublished work based on a draft report prepared by Pacific Northwest National Laboratory (PNNL) for the Hanford Waste Treatment and Immobilization Plant (WTP) in 2012. Work on the report stopped when WTP’s approach to testing changed. PNNL is issuing a modified version of the document a year later to preserve and disseminate the valuable technical work that was completed. This document establishes technical bases for evaluating the mixing performance of Waste Treatment Plant (WTP) pretreatment process tanks based on data from less-than-full-scale testing, relative to specified mixing requirements. The technical bases include the fluid mechanics affecting mixing for specified vessel configurations, operating parameters, and simulant properties. They address scaling vessel physical performance, simulant physical performance, and “scaling down” the operating conditions at full scale to define test conditions at reduced scale and “scaling up” the test results at reduced scale to predict the performance at full scale. Essentially, this document addresses the following questions: • Why and how can the mixing behaviors in a smaller vessel represent those in a larger vessel? • What information is needed to address the first question? • How should the information be used to predict mixing performance in WTP? The design of Large Scale Integrated Testing (LSIT) is being addressed in other, complementary documents.

non-Newtonian↗

An Approach to Understanding Cohesive Slurry Settling, Mobilization, and Hydrogen Gas Retention in Pulsed Jet Mixed Vessels

The Hanford Waste Treatment and Immobilization Plant (WTP) is being designed and built to pretreat and vitrify a large portion of the waste in Hanford’s 177 underground waste storage tanks. Numerous process vessels will hold waste at various stages in the WTP. Some of these vessels have mixing-system requirements to maintain conditions where the accumulation of hydrogen gas stays below acceptable limits, and the mixing within the vessels is sufficient to release hydrogen gas under normal conditions and during off-normal events. Some of the WTP process streams are slurries of solid particles suspended in Newtonian fluids that behave as non-Newtonian slurries, such as Bingham yield-stress fluids. When these slurries are contained in the process vessels, the particles can settle and become progressively more concentrated toward the bottom of the vessels, depending on the effectiveness of the mixing system. One limiting behavior is a settled layer beneath a particle-free liquid layer. The settled layer, or any region with sufficiently high solids concentration, will exhibit non-Newtonian rheology where it is possible for the settled slurry to behave as a soft solid with a yield stress. In this report, these slurries are described as settling cohesive slurries.

08 HYDROGEN↗

Applying Hanford Tank Mixing Data to Define Pulse Jet Mixer Operation

Pulse jet mixed (PJM) process vessels are being developed for storing, blending, and chemical processing of nuclear waste slurries at the Waste Treatment and Immobilization Plant (WTP) to be built at Hanford, Washington. These waste slurries exhibit variable process feed characteristics including Newtonian to non-Newtonian rheologies over a range of solids loadings. Waste feed to the WTP from the Hanford Tank Farms will be accomplished via the Waste Feed Delivery (WFD) system which includes million-gallon underground storage double-shell tanks (DSTs) with dual-opposed jet mixer pumps. Experience using WFD type jet mixer pumps to mobilize actual Hanford waste in DSTs may be used to establish design threshold criteria of interest to pulse jet mixed process vessel operation. This paper describes a method to evaluate the pulse jet mixed vessel capability to process waste based on information obtained during mobilizing and suspending waste by the WFD system jet mixer pumps in a DST. Calculations of jet velocity and wall shear stress in a specific pulse jet mixed process vessel were performed using a commercial computational fluid dynamics (CFD) code. The CFD-modelled process vessel consists of a 4.9-m- (16-ft-) diameter tank with a 2:1 semi-elliptical head, a single, 10-cm (4-in.) downward facing 60-degree conical nozzle, and a 0.61-m (24-in.) inside diameter PJM. The PJM is located at 70% of the vessel radius with the nozzle stand-off-distance 14 cm (6 in.) above the vessel head. The CFD modeled fluid velocity and wall shear stress can be used to estimate vessel waste-processing performance by comparison to available actual WFD system process data. Test data from the operation of jet mixer pumps in the 23-m (75-ft) diameter DSTs have demonstrated mobilization, solid particles in a sediment matrix were moved from their initial location, and suspension, mobilized solid particles were moved to a higher elevation in the vessel than their initial location, of waste solids. Jet mixer pumps were used in Hanford waste tank 241-AZ-101, and at least 95% of the 0.46-m (18-in.) deep sediment, with a shear strength of 1,500 to 4,200 Pa, was mobilized. Solids with a median particle size of 43 μm, 90th percentile of 94μm, were suspended in tank 241-AZ-101 to at least 5.5 m (216 in.) above the vessel bottom. Analytical calculations for this jet mixer pump test were used to estimate the velocities and wall shear stress that mobilized and suspended the waste. These velocities and wall shear stresses provide design threshold criteria which are metrics for system performance that can be evaluated via testing. If the fluid motion in a specific pulse jet mixed process vessel meets or exceeds the fluid motion of the demonstrated performance in the WFD system, confidence is provided that that vessel will similarly mobilize and suspend those solids if they were within the WTP. The single PJM CFD-calculated jet velocity and wall shear stress compare favorably with the design threshold criterion estimated for the tank 241-AZ-101 process data. Therefore, for both mobilization and suspension, the performance data evaluated from the WFD system testing increases confidence that the performance of the pulse jet mixed process vessels will be sufficient to process that waste even if that waste is not fully characterized.

mixing' slurry↗

EVALUATING CONCENTRATION PROFILES DURING UNSTEADY MIXING

Pulse jet mixing tests to suspend noncohesive solids in Newtonian liquid were conducted at three geometric scales. To understand the solids suspension process an ultrasonic concentration probe was used to measure the concentration of solids in the cloud during a pulse at various elevations and radial positions. The data are being analyzed to provide a model for predicting concentration as a function of elevation. This paper presents a simple single frequency ultrasonic measurement application that demonstrates the ability of ultrasonic sensors to measure slurry concentration based on signal attenuation. Sensor calibration data show that ultrasonic signal attenuation is proportional to the applied frequency and to the slurry volume fraction. Real-time measurements of ultrasonic signal attenuation were used to track the process of slurry mixing using single sensors and sensor arrays. Comparison of means of the ultrasonic measurements with means obtained from discrete extractive measurements show that the distributions overlap and cannot be statistically distinguished. The real-time ultrasonic sensor can be used as a primary measurement method or to reduce reliance upon extractive methods to measure slurry density.

42 ENGINEERING↗