Search NASASearch

SEARCH · Search NASA

Results for “pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Techno-Economic Evaluation of a 600MW Pumped Storage Hydropower Plant using the Pumped Storage Hydropower Valuation Tool

This paper presents a techno-economic evaluation of the proposed 600 MW, 8-hour Craig – Hayden pumped storage hydropower project using the U.S. Department of Energy’s Pumped Storage Hydropower Valuation Tool. The analysis integrates plant technical characteristics, regional grid conditions, and market-based operating assumptions to quantify stacked value streams from energy arbitrage, capacity, ancillary services, transmission congestion relief, and reliability. Both price taker and price influencer frameworks are applied to examine the impact of market participation and system interactions on lifecycle economic performance using Benefit - Cost Analysis and Multi - Criteria Decision Analysis. The results show that the price taker approach provides higher revenue estimates based on exogenous price signals, while the price influencer approach captures production cost savings, renewable curtailment reduction, and market price formation, yielding more conservative but system-representative outcomes. The study demonstrates the strategic value of long-duration PSH for enhancing operational flexibility, resource adequacy, and grid reliability in a high-renewable Western Interconnection.

Bhattacharyya, Arjun [ORNL] (ORCID:000900060976046

Performance of pumped counterflow virtual impactors to study aerosol interactions with laboratory generated warm clouds

Pumped Counterflow Virtual Impactors (PCVI) are designed to separate aerosols based on aerodynamic diameter, which is particularly useful for isolating cloud droplets and ice crystals from smaller particles. However, the PCVI transmission efficiency (TE) values reported in the literature show considerable variability, and little information is available on the TEs for cloud liquid droplets. Here, we determined the optimal flow conditions for PCVI sampling for different activation ratios from the MTU Pi-cloud chamber, highlighting the conditions that maximize droplet residual sampling while minimizing interstitial transmission. Even for a lower limit cloud activation ratio = 1:10, an add flow of 1.5 LPM achieves a residual fraction greater than 0.80, with a droplet TE of ∼15% for typical Pi-Chamber droplets with diameters between 3.5 to 10 µm. This framework can be adapted for field cloud measurements based on the cloud conditions of interest. TE for cloud droplets under flow conditions at which ∼99% of the unactivated submicron particles were removed was substantially lower between 8 and 16% than for supermicron dry particles (∼30 to 40% for 3 µm polystyrene latex spheres). In addition, we conducted a comparison of the performances of three similar PCVI units to assess repeatability for dry aerosols and cloud droplets. All three PCVIs performed similarly in rejecting submicron particles smaller than the desired cutoff diameter. One of the units showed lower TEs due to a misalignment of the internal orifice. We discuss a procedure that improved alignment and performance.

54 ENVIRONMENTAL SCIENCES

Technoeconomic Studies for the Rorex Creek Pumped Storage Hydro Project: An Evaluation of New Pumped Storage Hydro in the Tennessee Valley Authority System

This report evaluates the economic viability of the proposed 1,200 MW, 23,365 MWh Rorex Creek Pumped Storage Hydro (PSH) plant that would be located near Pisgah, Alabama. In addressing this question, this study has developed processes, models and data that better value PSH from a utility perspective, more specifically a vertically integrated utility, enabling optimal PSH design and deployment. This study is designed to enhance TVA’s toolset in making PSH investment decisions and contribute to the design of a more cost-effective, stable future grid. These techniques can then be applied to a broader range of assets and utilities.

Cohen, Stuart

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control

A miniature jet pump for slurries

Here, this work reports on the design and performance of a jet pump system to pump slurries. The jet pump uses a high-velocity water jet to entrain and pump the slurry. This pumping action requires no valves and does not use moving solid parts. Hence, the system can be readily sealed, and the pumping action creates no observable mechanical damage to slurry particles. We tested carbon black beads suspended in water at concentrations of 0.0, 0.2, and 2.0 wt% at primary jet flow rates of 50 and 100 mL/min. Our measurements show an approximately linear decrease in entrainment ratio (slurry-to-jet flow rate) and absolute slurry flow rate with increasing adverse (load) pressure difference. The entrainment ratio is a strong function of the absolute jet flow rate. Pump performance was insensitive to slurry composition. Micron-resolution particle image velocimetry (micro-PIV) revealed qualitative changes in the pump’s internal flow due to changes in absolute jet flow rate, including evidence of the suppression of a vortex at higher flow rates. These findings establish key operational parameters for the jet pump and highlight its potential in a variety of slurry flow pumping applications. The pump is particularly suited for flow electrode slurries (e.g. as used for energy storage and water treatment) as it maintains particle integrity and can be used with standard tubing, tube fittings, and sealing methods.

42 ENGINEERING

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump

Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants

Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, wide-spread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the “saturation cycle,” which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This work develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to −25 °C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51–57 % or 73–80 %, respectively, depending on the refrigerant. Furthermore, at −25 °C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that two-phase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at −25 °C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control

Defining an industrial heat pump: A review & synthesis

Clear and understandable definitions of advanced energy technologies are not common and often confuse those who are not experts. This review paper addresses a critical issue in the field of heat pumps: the ambiguity surrounding the term “industrial heat pump.” The term, as discussed in various literature and media, often leads to misconceptions about the capabilities and applications of heat pumps, particularly in industrial contexts. This review paper seeks to refine and unify the definition of industrial heat pumps by analyzing existing academic and commercial literature, industry reports, and classifications. Unique identifiers explored for the definition of an industrial heat pump include the use of waste heat, operating temperature ranges, size specifications, and specific end-use applications. The study reveals differences in how industrial heat pumps are defined in academic and commercial contexts, highlighting the need for a standardized definition to facilitate better communication among manufacturers, policymakers, and end users. This is especially important considering recent legislative efforts such as the HEAT Act, which seeks to promote industrial heat pump adoption. The proposed definition aims to provide clarity while supporting the effective deployment of industrial heat pumps. With proper adoption, the definition will help promote the role of industrial heat pumps in achieving energy efficiency goals in the industrial sector. The intended impact is for the definition to serve as a foundational reference for future research and policy development.

Heat pump characteristics

Preliminary Testing of a Continuous Cryopump for Primary Fusion Device Pumping and Direct Internal Recycling

Here, the concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa ⋅ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.

Gebhart III, Trey E. [Oak Ridge National Laborator

Specificity and tunability of efflux pumps: A new role for the proton gradient?

Efflux pumps that transport antibacterial drugs out of bacterial cells have broad specificity, commonly leading to broad spectrum resistance and limiting treatment strategies for infections. It remains unclear how efflux pumps can maintain this broad spectrum specificity to diverse drug molecules while limiting the efflux of other cytoplasmic content. We have investigated the origins of this broad specificity using theoretical models informed by the experimentally determined structural and kinetic properties of efflux pumps. We developed a set of mathematical models describing operation of efflux pumps as a discrete cyclic stochastic process across a network of states characterizing pump conformations and the presence/absence of bound ligands and protons. These include a minimal three-state model that lends itself to clear analytic calculations as well as a five-state model that relaxes some of the simpler model’s most strict assumptions. We found that the pump specificity is determined not solely by the drug affinity to the pump–as is commonly assumed–but it is also directly affected by the periplasmic pH and the transmembrane potential. Therefore, changes to the proton concentration gradient and voltage drop across the membrane can influence how effective the pump is at extruding a particular drug molecule. Furthermore, we found that while both the proton concentration gradient across the membrane and the transmembrane potential contribute to the thermodynamic force driving the pump, their effects on the efflux enter not strictly in a combined proton motive force. Rather, they have two distinguishable effects on the overall throughput. These results highlight the unexpected effects of thermodynamic driving forces out of equilibrium and illustrate how efflux pump structure and function are conducive to the emergence of multidrug resistance.

59 BASIC BIOLOGICAL SCIENCES

Root cause analysis of a molten salt pump in FLUSTFA

The primary salt pump installed in the high-temperature FLUoride Salt Test Facility (FLUSTFA) was successfully operated for some time, but later ceased operation. To understand what occurred, a Root Cause Analysis (RCA) was performed. Steps taken to try to get the pump operational include adjusting the shaft position, increasing the heating power of the tape heaters on the pump volute, and manually rotating the pump shaft. While removing the insulation, corrosion was noted on the outside of the pump volute, and decolorization of the insulation and tape heaters was observed. Significant corrosion products were also observed in the pump itself and the piping connected to the pump. The nitrogen cover gas was maintained from before salt was introduced into the loop until the pump was dismounted and continues to be maintained even after the pump was removed. After considering probable scenarios, causes were assigned and corrective actions were developed to prevent those causes. Then, the RCA was presented to an advisory committee for review, the “Review Committee,” consisting of experts in large molten salt systems: Brandon Haugh, David Holcomb, Kevin Robb, and Vicente Rojas. As a result, the advisory committee provided comprehensive feedback, which have been incorporated into a revised RCA. Findings have then been summarized and reported in this publication.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Simulations of divertor designs that spatially separate power and particle exhaust using mid-leg divertor particle pumping

Predictive design modeling of a Dissipation-Focused Divertor for future operation in DIII-D reveals that increasing the poloidal distance of the pump duct entrance from the target surface along the low-field side divertor baffle increases neutral compression and modifies the spatial distribution of power dissipation. With a divertor pump located mid-leg between the target and the X-point, SOLPS-ITER boundary plasma simulations without drifts predict the formation of a dense neutral cloud near the target with > 30x higher neutral compression in detachment, a more stable detachment front located further from the target, and ~25% lower outer midplane separatrix density required for detachment onset, compared to a pump located in the scrape-off layer at the target surface. Up to 19 MW of power flowing into the divertors is modeled using the following two numerical implementations for particle pumping: a specified fraction of particles incident on variable wall sections of the plasma grid is removed from the computational domain (so-called albedo pumping), and a pump duct is modeled which includes dynamics of kinetic neutrals in the duct. The simulations show that the detachment front is located between the divertor target and the X-point and is relatively stable near the pump entrance, without a strong dependence on gas puff rate or injected power. The mid-leg pump design spatially separates the two primary functions of a divertor (power handling and particle exhaust), with the majority of power dissipation occurring near the target plate and particle exhaust taking place further upstream. The benefit of enhanced dissipation using mid-leg pumping comes at the cost of a higher outer midplane separatrix density for a given amount of particle injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Continued Testing and Modeling of the AirSquared All-Metal Tritium Scroll Pump

The implementation of fusion energy requires the processing of the deuterium-tritium mixture used to fuel the reaction. Many gas processing operations require either a gas-motive force or a pressure gradient across a system; both are achieved using vacuum pumps. However, because of the material challenges of working with tritium, specialized pumps are required that use only metal on wetted surfaces. This prevents tritium retention and degradation of materials such as oils and polymers and reduces the generation of tritiated waste. Typical gas handling systems for tritium operations involve metal bellows pumps, all-metal scroll pumps, and metal turbomolecular pumps, depending on the pressure requirements. With the industry standard Normetex Type 15 m 3 /h (typically referred to as the Normetex 15) pump no longer available, the fusion market requires viable alternatives. In this study, we test an American-made pump, the AirSquared V16H034A-C01, and compare its performance to the Normetex. A performance model of the AirSquared pump is also produced, which can be applied to general process models to generate an accurate description of pressures and flows through various unit operations.

08 HYDROGEN

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research