Search NASA⌕ Search

SEARCH · Search NASA

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wireless Sensor for Measuring Pump Efficiency: Small Business Voucher Project with KCF Technologies

This document is to fulfill the final report requirements for the Small Business Voucher (SBV) CRADA project with ORNL and KCF Technologies (CRADA/NFE-16-06133). Pumping systems account for nearly 20% of the world’s electrical energy demand and range from 25-50% of the energy usage in many industrial and building power plants. The energy cost is the largest element in the total cost of owning a pump (~40%). In response to a recent DOE mandate for improved pump efficiency pump manufacturers are preparing for the changes that the impending regulations will bring, including design improvements. This mandate also establishes a need for new low cost pump efficiency measurement systems. The standard industry definition of pump efficiency is the mechanical water horsepower delivered divided by the electrical horsepower input to the motor. KCF Technologies has developed a new sensor measurement technique to estimate fluid pump efficiency using a thermodynamic approach. KCF Technologies applied for a SBV grant with ORNL as the research partner. KCF needed a research partner with the proper facilities to demonstrate the efficacy of its wireless sensor unit for measuring pump efficiency. The ORNL Building Technologies Research and Integration Center (BTRIC) test resources were used to test and demonstrate the successful measurement of pump efficiency with the KCF sensor technology. KCF is now working on next steps to commercialize this sensing technology.

42 ENGINEERING↗

Continental-Scale Geographic Trends in Barometric-Pumping Efficiency Potential: A North American Case Study

Barometric pumping is a gas transport mechanism that has important implications for many applications involving subsurface gas seepage processes. Here, this study provides the first continental-scale analysis of barometric-pumping efficiency potential based on meteorology. We quantified the barometric-pumping efficiency potential at 1,257 locations across the continental US and Canada. The results provide continental-scale geographic dependencies of barometric-pumping efficiency potential, indicating a significant correlation with latitude and a nonlinear dependence on longitude. The analysis also indicates that variability in barometric-pumping efficiency potential decreases with distance from the coast and as elevation increases. Locations far from the coastline are more likely to have upper mid-range potentials, while higher elevation locations are more likely to have low potentials. The highest barometric-pumping efficiency potentials are mostly found around the Gulf of St. Lawrence around 50°N. Locations along the Atlantic coast exhibit large-scale variations in potentials with a clear increasing trend with latitude.

58 GEOSCIENCES↗

Variable-Speed Pump Efficiency Calculation For Fluid Flow Systems with and without Static Head

To accurately calculate pump energy savings gained from implementing variable frequency drive (VFD) controls, the variation of pump efficiency must be considered when operating conditions transition from the design operating point to new operating points. Many software tools require users to specify the new pump efficiency, or it is assumed to be unchanged. Unfortunately, many users have challenges of estimating the pump efficiency at new operating points. This paper presents a simplified method of estimating centrifugal pump efficiency at new operating speeds when the pump is controlled by a VFD. This methodology applies to systems with and without static head when the system curve is not affected by the change, and also systems where the change in operation changes the system curve.A hypothetical fluid flow system and centrifugal pump were used to demonstrate the calculation process for these scenarios. For this hypothetical system, the pump’s efficiency at new operating points was up to 5.4% lower than the design operating point.

42 ENGINEERING↗

Role of spin mixing conductance in spin pumping: Enhancement of spin pumping efficiency in Ta/Cu/Py structures

From spin pumping measurements in Ta/Py devices for different thicknesses of Ta, we determine the spin Hall angle to be 0.021–0.033 and spin diffusion length to be 8 nm in Ta. We have also studied the effect of changing the properties of non-magnet/ferromagnet interface by adding a Cu interlayer. The experimental results show that the effective spin mixing conductance increases in the presence of Cu interlayer for Ta/Cu/Py devices whereas it decreases in Pt/Cu/Py devices. Our findings allow the tunability of the spin pumping efficiency by adding a thin interlayer at the non-magnet/ferromagnet interface.

36 MATERIALS SCIENCE↗

Fan and Pump Efficiency in Modelica based on the Euler Number

Simulation programs often assume constant hydraulic efficiency for fan or pump models when performance curves are unavailable. This is inaccurate because the hydraulic efficiency varies with the operation condition. It therefore consistently underestimates the power draw at off-design conditions at which the hydraulic efficiency drops. Use of a modified Euler number allows computing the hydraulic efficiency and shaft power with limited data. Others showed the validity of the modified Euler number for fan efficiency calculations. We show that it is also applicable for pumps, and present its implementation in Modelica for a fan or pump model. Here, the only input required from the user is one data point at which the hydraulic efficiency is at its maximum. The reported method is applicable regardless of the type, size, or operational region of the fan or pump. Across a sample of eighteen sets of pump data and seven sets of fan data, the errors of the computed power from interpolated data were within 15% for the range of 20% - 70% of maximum flow rate and 40% - 90% of maximum pressure rise, excluding outliers.

component model↗

Variability of absorption heat pump efficiency for domestic water heating and space heating based on time-weighted bin analysis

Natural gas-driven absorption heat pumps are under renewed scrutiny as a viable technology for space conditioning and water heating for residential and commercial applications because of natural gas production trends, pricing, and the speculation that it might be a “bridge fuel” in the global transition towards energy sustainability. Since any level of natural gas combustion contributes to atmospheric carbon dioxide accumulation, the merits of natural gas consuming absorption technology are re-examined in this paper from the point of view of expected efficiency throughout the United States using a time-weighted bin temperature analysis. Such analyses are necessary because equipment standards for rated performance is restricted to one set ambient condition, whereas in actual practice, the absorption heat pump (AHP) must perform over a considerably wider range of external conditions, where its efficiency may be vastly different from that at the rated condition. Quantification of variation in efficiency and system performance are imperative to address how to provide the desired utility with the least environmental impact. In this paper, we examine limiting features in absorption heat pumps and relate it to systemic performances in sixteen cities across all eight climate zones in the U.S, each containing fifteen bin temperatures. The results indicate that the true expectation of performance of an AHP is significantly less than what might be optimized for the rated condition. Statistical measures of the variation in water heating COPs show that for most cities, the COP at the rated conditions is outside the 95% Confidence Interval. Moreover, it is concluded that deployment of absorption heat pump water heaters (AHPWH) may be restricted geographically by outdoor temperature constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of highly efficient NEG pumping system for EBIS

Ultrahigh vacuum inside the ion trap volume is crucial for stable and reliable operation of an Electron Beam Ion Source (EBIS). We have developed and tested a compact linear pumping system based on the ZAO Non-Evaporable Getter (NEG) module with high pumping speed and enhanced sorption capacity for all active gases. Due to its minimal transverse dimensions, the system can be mounted adjacent to the ion trap inside a superconducting solenoid bore and will provide a pumping speed of the order of 1000 l/s for all active gases in that area. An externally supplied current (100 A DC) is used to heat the ZAO NEG up to 650 °C for more than 1 h, which is required for pump activation and/or reactivation cycles. The pumping system is being developed for use in the Extended EBIS Upgrade which is presently in progress at BNL. In conclusion, the design of the system and results of multiple tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

EFFECT OF PORE SIZE ON TRAPPING ZINC VAPORS

A series of experiments were conducted to determine the effect of pore size on pumping efficiency and zinc vapor trapping efficiency. A simple pumping efficiency test was conducted for all five pore diameters where it was observed that evacuation times were adversely affected by reducing the pore size below 5 {micro}m. Common test conditions for the zinc trapping efficiency experiments were used. These conditions resulted in some variability, to ascribe different efficiencies to the filter media. However, the data suggest that there is no significant difference in trapping efficiency for filter media with pores from 0.2 to 20 {micro}m with a thickness of 0.065-inch. Consequently, the 20 {micro}m pore filter media that is currently used at SRS is a suitable filter material for to utilize for future extractions. There is evidence that smaller pore filter will adversely affect the pumping times for the TEF and little evidence to suggest that a smaller pore diameters have significant impact on the trapping efficiency.

99 GENERAL AND MISCELLANEOUS↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

Energy Productivity of the High Velocity Algae Raceway Integrated Design (ARID-HV)

The ARID raceway is an effective method to maintain temperature in the optimal growing range. However, the energy input is excessive. Thus, the ARID-HV raceway was developed in order to reduce energy input requirements. This was accomplished by improving pumping efficiency and using a serpentine flow pattern in which the water flows through channels instead of over barriers. A prototype ARID-HV raceway was installed in Tucson, Arizona in order to evaluate the flow and energy requirements of the raceway. Preliminary results show continued high energy usage, but this paper explores the possible energy reductions with the new ARID-HV design with efficient propeller pumps and properly engineered channel lengths. Channel lengths are evaluated with Manning’s equation in order to determine the maximum channel length that could be implemented with the current pumping configuration

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Efficiency Axial Pumps for Reactor Use

The flow of viscous liquid in highly efficient commercial axial pumps is hydrodynamically analyzed. Design recommendations are made regarding the flow sections of the pump, so as to ensure a pressure characteristic with no descending section and efficient coolant circulation in a fast-neutron reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving pumping system efficiency at coal plants

The industry must employ ultramodern technologies when building or upgrading power plant pumping systems thereby using fuels more efficiently. The article discusses the uses and efficiencies of positive displacement pumps, centrifugal pumps and multiple screw pumps. 1 ref., 4 figs.

20 FOSSIL-FUELED POWER PLANTS↗

Fluid Modeling of an ELMing H-mode and a RMP H-mode

In this paper, we investigate the role of wall conditions during the density pump-out observed in Resonant Magnetic Perturbation (RMP) experiments. We use a 2D fluid code, coupled to a neutral Monte-Carlo code (SOLPS5) to model a reference ELMing H-mode. Next we modify either the recycling at the target plates or the pumping efficiency at the pump entrance. This causes a change in upstream profiles, that alone cannot account for the shape change observed in the RMP H-mode. Therefore, the radial transport must be altered to match the RMP H-mode. By comparing the transport model for the ELMing H-mode and the RMP H-mode, we show that inside the separatrix an increase in transport is necessary to model the effects of the applied perturbed field in RMP H-mode. (C) 2009 Elsevier B.V. All rights reserved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of diode-pump absorption efficiency and thermo-optical effects in a high-power Yb:KGW laser

Diode-pump absorption is experimentally studied in a high-power Yb:KGd(WO{sub 4}){sub 2} (Yb:KGW) laser in the presence and absence of lasing. The maximum absorption efficiency in the cw regime exceeds 77% which is by a factor of 1.4 greater than the maximum absorption efficiency in the absence of lasing. The powers of thermo-optical lenses induced in laser crystals during lasing are measured. A strong dependence of the lens power and aberrations on the orientation of laser crystals relative to the propagation direction and polarisation is confirmed. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Copper vapour laser with an efficient semiconductor pump generator having comparable pump pulse and output pulse durations

We report the results of experimental studies of a copper vapour laser with a semiconductor pump generator capable of forming virtually optimal pump pulses with a current rise steepness of about 40 A ns{sup -1} in a KULON LT-1.5CU active element. To maintain the operating temperature of the active element's channel, an additional heating pulsed oscillator is used. High efficiency of the pump generator is demonstrated. (lasers)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Generation of meter-scale hydrogen plasmas and efficient, pump-depletion-limited wakefield excitation using 10 GeV electron bunches

High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC national accelerator laboratory. Here we have generated meter-scale hydrogen plasmas using time-structured 10 GeV electron bunches from FACET-II, which hold the promise of dramatically increasing the repetition rate of PWFA by rapidly replenishing the gas between each shot compared to the hitherto used lithium plasmas that operate at 1–10 Hz. Furthermore, we have excited wakes in such plasmas that are suitable for high gradient particle acceleration with high drive-bunch to wake energy transfer efficiency- a first step in achieving a high overall energy transfer efficiency. We have done this by using time-structured electron drive bunches that typically have one or more ultra-high current (> 30 kA) femtosecond spike(s) superimposed on a longer (~0.4 ps) lower current (< 10 kA) bunch structure. The first spike effectively field-ionizes the gas and produces a meter-scale (30–160 cm) plasma, whereas the subsequent beam charge creates a wake. The length and amplitude of the wake depends on the longitudinal current profile of the bunch and plasma density. We find that the onset of pump depletion, when some of the drive beam electrons are nearly fully depleted of their energy, occurs for hydrogen pressure ≥ 1.5Torr. We also show that some electrons in the rear of the bunch can gain several GeV energies from the wake. These results are reproduced by particle-in-cell simulations using the QPAD code. At a pressure of ~2Torr, simulation results and experimental data show that the beam transfers about 60% of its energy to the wake.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗