The development of a cryogenic over-pressure pump

A cryogenic over-pressure pump (OPP) was tested in the prototype telescope liquid nitrogen (LN2) cooling system for the Dark Energy Survey (DES) Project. This OPP consists of a process cylinder (PC), gas generator, and solenoid operated valves (SOVs). It is a positive displacement pump that provided intermittent liquid nitrogen (LN2) flow to an array of charge couple devices (CCDs) for the prototype Dark Energy Camera (DECam). In theory, a heater submerged in liquid would generate the drive gas in a closed loop cooling system. The drive gas would be injected into the PC to displace that liquid volume. However, due to limitations of the prototype closed loop nitrogen system (CCD cooling system) for DECam, a quasiclosed-loop nitrogen system was created. During the test of the OPP, the CCD array was cooled to its designed set point temperature of 173K. It was maintained at that temperature via electrical heaters. The performance of the OPP was captured in pressure, temperature, and flow rate in the CCD LN2 cooling system at Fermi National Accelerator Laboratory (FNAL)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Edwards nXDS15iC Vacuum Scroll Pump Pressure Testing

The SRNL High Pressure Laboratory performed testing on an Edwards Model nXDS15iC Vacuum Scroll Pump on July 10th and 11th of 2013 at 723-A. This testing was done in an attempt to obtain initial compression ratio information for the nXDS15iC pump, with compression ratio defined as discharge pressure of the pump divided by suction pressure. Pressure burst testing was also done on the pump to determine its design pressure for pressure safety reasons. The Edwards nXDS15iC pump is being evaluated by SRNL for use part of the SHINE project being executed by SRNL.

42 ENGINEERING↗

Reduction of waveguide vacuum trips in CEBAF accelerating cavities with a combination ion pump and non-evaporable getter pump

Pressure spikes in the fundamental power coupler waveguide are a significant source of trips during the operation of both original and refurbished superconducting radio-frequency cavities installed in the CEBAF accelerator. In its original configuration, two waveguides from a cavity-pair are connected to a single 32 l/s ion pump. In 2017 a new cavity-pair was installed in a refurbished cryomodule in which a NEXTorr® D200-5 combination ion pump and non-evaporable getter pump was installed for each waveguide. It is shown that hydrogen is the dominant residual gas in the waveguide and simulations with Molflow+ indicated that the new pumping scheme allows reducing the pressure at the end of the waveguide by a factor of ~5 , compared to the original configuration. In conclusion, the new cavity-pair has been operating in CEBAF for a total of 431 days and it only had a total of 3 trips due to vacuum spikes in the waveguide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incorporating high-pressure electroosmotic pump and a nano-flow gradient generator into a miniaturized liquid chromatographic system for peptide analysis

Here we integrate a high-pressure electroosmotic pump (EOP), a nanoflow gradient generator, and a capillary column into a miniaturized liquid chromatographic system that can be directly coupled with a mass spectrometer for proteomic analysis. We have recently developed a low-cost high-pressure EOP capable of generating pressure of tens of thousands psi, ideal for uses in miniaturized HPLC. The pump worked smoothly when it was used for isocratic elutions. When it was used for gradient elutions, generating reproducible gradient profiles was challenging; because the pump rate fluctuated when the pump was used to pump high-content organic solvents. This presents an issue for separating proteins/peptides since high-content organic solvents are often utilized. In this work, we solve this problem by incorporating our high-pressure EOP with a nano-flow gradient generator so that the EOP needs only to pump an aqueous solution. With this combination, we develop a capillary-based nano-HPLC system capable of performing nano-flow gradient elution; the pump rate is stable, and the gradient profiles are reproducible and can be conveniently tuned. Finally, to demonstrate its utility, we couple it with either a UV absorbance detector or a mass spectrometer for peptide separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regenerative amplification of picosecond 10-{mu}m pulses in a high-pressure optically pumped CO{sub 2} laser

A model is developed and numerical calculations are performed for the regenerative amplification of seed picosecond 10-{mu}m radiation pulses in a high-pressure optically pumped CO{sub 2} laser. It is established that by varying the cavity parameters, the conditions of efficient regenerative amplification may be optimised for the case of a relatively short-duration (50 ns) solid-state Cr:Er:YSGG laser and 'long-duration' (250 ns) electrodischarge chemical HF laser. It is shown that the schemes of a CO{sub 2} amplifier with optical pumping presented allow obtaining the pulses with the duration of 3ps, output energy of 1-5 mJ, and peak power of {approx}1 GW at the pump energy of 150-200 mJ. (lasers and amplifiers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geomechanical and Hydrogeological Evaluation of a Shallow Hydraulic Fracture at the Devine Fracture Pilot Site, Medina County, Texas

UT-Austin’s Devine Fracture Pilot Site, 50 miles southwest of San Antonio, Texas, has been targeted for a comprehensive, multidisciplinary development of fracture diagnostic techniques that are cross-validated by ground-truth data acquisition near a recently created, 175-ft-deep, horizontal hydraulic fracture (Ahmadian et al. 2018 Demonstration of proof of concept of electromagnetic geophysical methods for high resolution illumination of induced fracture networks. In Proceedings of the SPE Hydraulic Fracturing Technology Conference and Exhibition, The Woodlands, Texas, USA, 23–25 January 2018. SPE-189858-MS.). To evaluate the fracture diagnostic methods at this site, we conducted injection tests with a predefined volumetric flow-rate profile, resembling a diagnostic fracture injection test on September 2020. Subsequently, we developed hydrogeological and geomechanical models based on flow-rate and bottomhole-pressure measurements. History-matching efforts using a simplified layer-cake hydrogeological model resulted in the field-scale formation permeability of 9.87 × 10 –15 m 2 (10 mD) and Darcy-scale fracture permeability. The analysis of the bottomhole pressure and injection-rate history showed that (1) the newly created horizontal fracture was closed adjacent to the injection well pre-injection and (2) the initial pump-pressure increase at a nominal volumetric injection rate led to near-well fracture reopening, fluid conductivity increase, and abrupt injection-rate increase. To overcome hydrogeological-model limitations of predicting fracture reopening throughout injection, we extended the modeling to a finite-element, poroelastic analysis of horizontal-fracture growth using a cohesive-zone model. Using this fracture-reopening model, we improved the history match of the transient-pressure response during the experiment by adjusting the hydromechanical properties. Furthermore, post-injection pressure transient analyses helped reduce uncertainty in the overburden-stress gradient, and the initial hydraulic-fracturing simulation verified the plausibility of achieving the surveyed propped fracture area.

02 PETROLEUM↗

Breakdown of Angular Momentum Selection Rules in High Pressure Optical Pumping Experiments

We present measurements, by using two complementary methods, of the breakdown of atomic angular momentum selection rules in He-broadened Rb vapor. Atomic dark states are rendered weakly absorbing due to fine-structure mixing during Rb-He collisions. The effect substantially increases the photon demand for optical pumping of dense vapors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Light Duty Engine Performance Characteristics with Dimethyl Ether and Propane

Here, this paper explores the performance characteristics of a compression ignition HYUNDAI 2.2L engine operating with Dimethyl Ether (DME). Test are carried out at three operating conditions that weigh heavily in the FTP75 certification cycle (1000rpm-12Nm, 1500rpm-50Nm, 2000rpm-100Nm). The engine features a high-pressure common rail fuel injection system designed to operate with liquified gases. The main component of the fuel system is a high-pressure pump that incorporates an electronic inlet metering valve commanded on a crank-angle base to control the rail pressure. The pump, which requires no pressure regulator, provides the flow needed to the injectors without flow returning to the inlet. This novel fueling system is leveraged in tests that are conducted to examine the impact of EGR, combustion phasing, injection pressure on efficiency and emissions. In addition, the impact of introducing 15% Propane by mass is examined. During the tests, the engine ECU is aided by an Engine Controller High Speed Oversight unit (ECHO) to provide combustion phasing control, improved cylinder-to-cylinder uniformity, and an effective optimization over the testing effort. The use of DME and Propane allowed for peak thermal efficiency of nearly 43%. These fuels enable significant carbon index (CI) reductions over the baseline Diesel fuel, with indications that 50% reduction in CO 2 over the Diesel engine are possible.

33 ADVANCED PROPULSION SYSTEMS↗

Correlations to predict frictional pressure loss of hydraulic-fracturing slurry in coiled tubing

Compared with conventional-tubing fracturing, coiled-tubing (CT) fracturing has several advantages. CT fracturing has become an effective stimulation technique for multizone oil and gas wells. It is also an attractive production-enhancement method for multiseam coalbed-methane wells, and wells with bypassed zones. The excessive frictional pressure loss through CT has been a concern in fracturing. The small diameter of the string limits the cross-sectional area open to flow. Furthermore, the tubing curvature causes secondary flow and results in extra flow resistance. This increased frictional pressure loss results in high surface pumping pressure. The maximum possible pump rate and sand concentration, therefore, have to be reduced. To design a CT fracturing job properly, it is essential to predict the frictional pressure loss through the tubing accurately. This paper presents correlations for the prediction of frictional pressure loss of fracturing slurries in straight tubing and CT. They are developed on the basis of full-scale slurry-flow tests with 11/2-in. CT and slurries prepared with 35 lbm/1,000 gal of guar gel. The extensive experiments were conducted at the full-scale CT-flow test facility. The proposed correlations have been verified with the experimental data and actual field CT-fracturing data. Case studies of wells recently fractured are provided to demonstrate the application of the correlations. The correlations will be useful to the CT engineers in their hydraulics design calculations.

01 COAL, LIGNITE, AND PEAT↗

DOE SBIR 2014 Topic 2.C – Phase I Final Report

Freshwater is a vital resource for human survival as well as a key component of a wide range of industrial and agricultural needs. However, only 0.65% of the world’s water resources are available as freshwater, and the demand on the world’s water reserves continues to increase, with the demand beginning to outpace the supply in many areas. A water-energy nexus is being reached that requires low –cost and –energy solutions for various degrees of treated water. In a 2012 survey, 88% of Americans were concerned about potential water shortages and approximately two-thirds of the world’s population will be suffering a water shortage over the next few years. Seawater and other saline water materials make up around 98% of the available water, representing an almost unlimited supply of water. The energy, cost and maintenance to remove salts and other unwanted compounds is a barrier to widespread implementation of salt-to-freshwater facilities. These facilities most commonly use reverse osmosis (RO) systems. Due to the high required pressures and moving parts these facilities consume much grid energy and require constant maintenance leading to high capital and operational costs. RO also generates highly concentrated brine that is costly to safely return to the ocean. Capacitive desalination (or capacitive deionization [CDI]) has no moving parts (aside from a low pressure pump and valves), operates at low pressure and does not generate brine that is hazardous to marine life. Not only can the capacitive charge/discharge be cycled almost indefinitely but the system uses low energy and capacitive discharge electrical current can be co-generated back to the system. However, CDI has not seen widespread use for large- or small- scale desalination because electrode efficiency limits the extraction rate below what is useful for most applications. Mainstream Engineering Corporation (MEC) has demonstrated an innovative new electrode structure for the high efficiency desalination of brackish water by capacitive deionization. Electrode manufacturing (nanomanufacturing) is a highly scalable and low-cost electrochemical self-assembly method using a templated process that Mainstream has pioneered and leveraged for several energy technologies over the last decade. The primary accomplishment for Phase I is the fabrication and demonstration of CDI electrode structures are: • Demonstrating the linear scalability of templated approach to the fabrication scaling the electrode structure. • Demonstrated the ability to tune the fabrication of the electrode structures to produce electrodes with a highly controllable aligned nanopore diameter and nanopore depth. • Demonstrated the efficient removal of a sodium chloride salt from brackish water with a 60 times improvement in mg-salt removed/g-carbon compared to a commercial system under the same conditions. • Demonstrated good reproducibility and stability of the electrode structure under realistic CDI operating conditions. • Demonstrated charge efficiency as high as 93% with an expected system level energy requirement of 0.7 to 1.5 kWh/m3 of water; significantly lower than the 2.9 to 3.7 kWh/m3 observed for RO systems Based on the performance characteristics of the electrodes, Mainstream was able to propose a modular and scalable capacitive deionization design that can be adapted to a wide range of conditions providing energy efficient desalination of brackish water.

36 MATERIALS SCIENCE↗

A lab-based ambient pressure x-ray photoelectron spectrometer with exchangeable analysis chambers

Ambient pressure X-ray photoelectron spectroscopy (APXPS) is a powerful spectroscopy tool that is inherently surface sensitive, elemental, and chemical specific, with the ability to probe sample surfaces under Torr level pressures. Herein, we describe the design of a new lab-based APXPS system with the ability to swap small volume analysis chambers. Ag 3d(5/2) analyses of a silver foil were carried out at room temperature to determine the optimal sample-to-aperture distance, x-ray photoelectron spectroscopy analysis spot size, relative peak intensities, and peak full width at half maximum of three different electrostatic lens modes: acceleration, transmission, and angular. Ag 3d(5/2) peak areas, differential pumping pressures, and pump performance were assessed under varying N{sub 2}(g) analysis chamber pressures up to 20 Torr. The commissioning of this instrument allows for the investigation of molecular level interfacial processes under ambient vapor conditions in energy and environmental research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Ion-Accessible Surface Area CNT-Ultracapacitors for Groundwater Desalination

Fresh water is a vital resource for human survival, as well as a key component for a wide range of industrial and agricultural needs. However, only 0.65% of the world’s water resources are available as fresh water, and the demand on the world’s water reserves continues to rise, with the demand already beginning to outpace the supply in many areas. A water-energy nexus is being reached that requires low -cost and -energy solutions for various degrees of treated water. Public awareness of the problem has also risen, such that in a 2012 survey, 88% of Americans reported concerns about potential water shortages. Approximately two-thirds of the world’s population could suffer water shortages over the next few years. Seawater and other saline water supplies make up around 98% of the world’s accessible water. Properly treated to reduce the levels of salinity, this represents an almost unlimited supply of fresh water. The high energy requirements, capital costs, and maintenance requirements to remove salts and other unwanted compounds, however, are barriers to widespread implementation of salt-to-freshwater facilities. These facilities most commonly use reverse osmosis (RO) systems that suffer from high required pressures and failures of moving parts; additionally, these facilities consume much grid energy and require constant maintenance, leading to high capital and operational costs. The RO process also generates large volumes of highly concentrated bio-hazardous brine that is costly to safely return to the ocean. In contrast to RO, capacitive desalination or capacitive deionization (CDI) has fewer moving parts (a low-pressure pump and several valves), operates at low pressure, and does not generate large quantities of brine that are hazardous to marine life. The capacitive charge/discharge of a CDI system can be cycled almost indefinitely, and the system has low energy requirements because the capacitive discharge electrical current can be co-generated back to the system. RO must remove the water from the salt while CDI removes the salt from the water. This represents a significant difference in the number of molecules which must be moved and energy required to desalinate water. However, CDI has not seen widespread use for large- or small-scale desalination because electrode efficiency has limited the extraction rate below what is useful for most applications. Mainstream demonstrated the following successes during this SBIR program: Performance - We developed an innovative new electrode structure for the high-efficiency removal of ions from salt-contaminated water samples by CDI. Based on prototype electrochemical tests, our CDI consumes as low as 0.71 kW/m 3 of treated water (compared to 2.9 to 3.7 kW/m 3 for RO). Scalability – During Phase II, we increased the electrode size from 3.8 cm 2 single-sided electrodes to 180 cm 2 double-sided electrodes. Using larger acid baths and CVD furnace, we increased electrode fabrication capacity increased by 315 times. Scalable electrochemical CDI stack design and balance of plant – During Phase II, we demonstrated at scalable low-pressure drop stack design and balance of plant for the continuous removal of ions. Corrosion Resistance – Based on accelerated corrosion testing data, our high-quality graphitic electrodes have a significantly improved corrosion resistance. This was 20 times better corrosion resistance than our Phase I electrodes and significantly higher than typical CDI system electrodes. Flexibility –By tuning the pore size of the electrode materials, we demonstrated the removal of key target ionic contaminants, such as sodium chloride, nitrate, and phosphate salts. These ionic contaminants are common in agricultural and industrial wastewater runoff and are difficult to remove by conventional methods, which require excessive use of reagents.

Cox, Dr. Philip↗

Utah FORGE: Drilling Data for Student Competition

Diagnostic drilling data (Pason log files) from Well 58-32 (previously labeled MU-ESW1), which was drilled near Milford Utah during Phase 2B of the FORGE Project to confirm geothermal reservoir characteristics met requirements for the final FORGE site. This dataset includes both raw, unprocessed drilling data recorded at 1Hz and a processed version downscaled to ~0.3m (1 ft) intervals. Diagnostic drilling data were collected to obtain useful information regarding the nature of the subsurface materials and performance of the drilling rig and drilling bits, including rate of penetration (ROP), weight on bit, temperature, pump pressure, etc.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Stimulation Pressure and Circulation Data April, 2024

This dataset consists of all of the pressure pumping data for Utah FORGE Well16A78-32 fracturing stages, Well 16B78-32 fracturing stages, and a 9-hour circulation test which took place after all of the frac plugs were drilled out. Fracturing in the wells took place in stages from April 3rd to April 17th, while the circulation test occurred on April 27th, 2024. Data is in excel files, with ReadMe files for each of the .zip folders that detail what data is available. Also attached here is wellhead pressure data from Pason that is referred to in the ReadMe files.

15 GEOTHERMAL ENERGY↗

Peristaltic pump-based low range pressure sensor calibration system

Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressure leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a High-Pressure Fuel Injection System for Use with Propane-DME

Paper details the design approach and performance of a high-pressure common rail fuel injection system used with Propane-DME mixtures targeting high injection pressures on a light duty 2.2L inline-4 compression ignition engine. The study estimates the bulk modulus of elasticity based on the hardware geometry and operating pressures to assess the compressibility of Propane and DME across a range of pressures typical of the LD engine application. The compressibility factor ranges from 500 to 3000 bar, significantly lower than the theoretical values for the conditions tested. The high-pressure pump performance is optimized via the implementation of an inlet metering valve operated on a crank-angle open/close sequence to control pressure at the common rail. The application of a model-based controller and the use of high-speed sampling of rail pressure indicate that pressure at the rail can be attained with the pump metering valve, and without use of the pressure relieve valve present in the rail. Results show a significant reduction on pumping work parasitics and of fuel heating, on the order of 40°C, at typical working conditions with the proposed approach. Injector rates of injection with Propane-DME are very similar to those of Diesel. Paper compares bench data of rates of injection versus simulation predictions across operating pressures of 200 to 1000bar and from injection commands spanning 0.20 to 2.0ms. Furthermore, the accuracy of the model predictions are attributed in part by to the updated fuel compressibility modulus descriptions attained during the testing.

42 ENGINEERING↗

The Turbulent Pressure Spectrum Within the Roughness Sublayer of a Subarctic Forest Canopy

The turbulent static pressure spectrum E pp (k x ) as a function of longitudinal wavenumber k x in the roughness sublayer of forested canopies is of interest to a plethora of problems such as pressure transport in the turbulent kinetic energy budget, pressure pumping from snow or forest floor, and coupling between flow within and above canopies. Long term static pressure measurements above a sub-arctic forested canopy for near-neutral conditions during the winter and spring were collected and analyzed for three snow cover conditions: trees and ground covered with snow, trees are snow free but the ground is covered with snow, and snow free cover. In all three cases, it is shown that E pp (k x ) obeys the attached eddy hypothesis at low wavenumbers (1/δ < k x < 1/z) —with E pp (k x ) ∝ u$^4_*$k$^{-1}_x$ and Kolmogorov scaling in the inertial subrange at higher wavenumbers—with E pp (k x ) ∝ ϵ 4/3 k x -7/3 , where u * is the friction velocity at the canopy top, is the mean turbulent kinetic energy dissipation rate, z is the distance from the snow top, and is the boundary layer depth. The implications of these two scaling laws to the normalized root-mean squared pressure C p = o p /u$^2_*$ and its newly proposed logarithmic scaling with normalized wall-normal distance z/δ are discussed for snow covered and snow free vegetation conditions. The work here also shows that k$^{-1}_x$ the in the E pp (k x ) appears more extensive and robust than its longitudinal velocity counterpart.

Aslan, Toprak [Finnish Meteorological Inst., Helsi↗