Quantitative Measurements of Surface and Subsurface Features with Quartz Tuning Fork Atomic Force Microscopy and Pump-Probe Optothermal Metrology
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.
Not Available
Superconducting quantum circuits (SQC) are one of the most promising hardware platforms for quantum computing, yet their performance is currently limited by the presence of various structural defects inside the circuit's structure. Despite impressive progress in the past decade, a precise understanding of the origin of these defects from various fabrication processes and their impact on coherence is still lacking. Here, in this study, we performed a comprehensive investigation on the microstructure, superconductivity, and resonator quality factor of Nb films deposited by high-power impulse magnetron sputtering (HiPIMS) and direct current (DC) magnetron sputtering. A suite of characterization techniques, including electron microscopy with spectroscopy, secondary ion mass spectrometry, magneto-optical microscopy, and pump-probe reflectivity spectroscopy is used. We reveal that niobium (Nb) resonators fabricated using HiPIMS exhibit a smaller average grain size, thicker surface oxide with larger thickness variations (rougher surface), and a thicker amorphous Nb/Si interface layer compared to samples deposited by DC sputtering. We identified that the amorphous Nb oxides (mainly located at the Nb surface and along the grain boundaries) and Nb-Si amorphous layers (at the Nb/Si interface) are major and potential sources of two-level system (TLS), while off-stochiometric oxides and suboxides of Nb close to the surface, crystalline defects (i.e., dislocations at grain boundary, point defects introduced during deposition) are main contributors of non-TLS sources. Our findings clarify the relationship between different defects and coherence loss mechanisms, highlighting the importance of material microstructure control on performance optimization in SQC.
Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ~17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ~6 h to ~5 min in a real-time imaging scenario.
Electron transfer and carrier dynamics in MoTe 2 /WS 2 /MoS 2 trilayer heterostructures are investigated by transient absorption and photoluminescence measurements. Monolayer flakes of MoTe 2 , WS 2 , and MoS 2 are obtained by mechanical exfoliation from their bulk crystals and are used to fabricate the heterostructures by a dry-transfer technique. Here, photoluminescence spectroscopic measurements indicate that the recombination of the MoS 2 and WS 2 intralayer excitons is significantly suppressed in the heterostructure, illustrating the efficient interlayer charge transfer processes. Layer-selective time-resolved differential reflectance measurements show that the electrons excited in MoTe 2 can transfer to MoS 2 within 0.3 ps. The transferred electrons show a long lifetime of several hundred picoseconds due to their slow recombination with the spatially separated holes that reside in MoTe 2 . Furthermore, the charge transfer and recombination processes are weakly dependent on the injected carrier density. These results demonstrate the feasibility of constructing van der Waals multilayer heterostructures involving the infrared-sensitive MoTe 2 with emergent properties and provide important information to quantify the performance of MoTe 2 - based devices.
Innovation in microscopy has often been critical in advancing both fundamental science and technological progress. Notably, the evolution of ultrafast near-field optical nano-spectroscopy and nano-imaging has unlocked the ability to image at spatial scales from nanometers to ångströms and temporal scales from nanoseconds to femtoseconds. This approach revealed a plethora of fascinating light-matter states and quantum phenomena, including various species of polaritons, quantum phases, and complex many-body effects. This review focuses on the working principles and state-of-the-art development of ultrafast tip-enhanced and near-field microscopy, integrating diverse optical pump-probe methods across the terahertz (THz) to ultraviolet (UV) spectral ranges. It highlights their utility in examining a broad range of materials, including two-dimensional (2D), organic molecular, and hybrid materials. The review concludes with a spatio-spectral-temporal comparison of ultrafast nano-imaging techniques, both within already well-defined domains, and offering an outlook on future developments of ultrafast tip-based microscopy and their potential to address a wider range of materials.
The understanding and control of charge carrier interactions with defects at buried insulator/semiconductor interfaces is essential for achieving optimum performance in modern electronics. In this work, we report on the use of scanning ultrafast electron microscopy (SUEM) to remotely probe the dynamics of excited carriers at a Si surface buried below a thick thermal oxide. Our measurements illustrate a previously unidentified SUEM contrast mechanism, whereby optical modulation of the space-charge field in the semiconductor modulates the electric field in the thick oxide, thus affecting its secondary electron yield. By analyzing the SUEM contrast as a function of time and laser fluence we demonstrate the diffusion mediated capture of excited carriers by interfacial traps.
Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.
Advancements in ultrafast electron microscopy have allowed elucidation of spatially selective structural dynamics. However, as the spatial resolution and imaging capabilities have made progress, quantitative characterization of the electron pulse trains has not been reported at the same rate. In fact, inexperienced users have difficulty replicating the technique because only a few dedicated microscopes have been characterized thoroughly. Systems replacing laser driven photoexcitation with electrically driven deflectors especially suffer from a lack of quantified characterization because of the limited quantity. The primary advantages to electrically driven systems are broader frequency ranges, ease of use and simple synchronization to electrical pumping. Here, we characterize the technical parameters for electrically driven UEM including the shape, size and duration of the electron pulses using low and high frequency chopping methods. At high frequencies, pulses are generated by sweeping the electron beam across a chopping aperture. For low frequencies, the beam is continuously forced off the optic axis by a DC potential, then momentarily aligned by a countering pulse. Using both methods, we present examples that measure probe durations of 2 ns and 10 ps for the low and high frequency techniques, respectively. Here, we also discuss how the implementation of a pulsed probe affects STEM imaging conditions by adjusting the first condenser lens.
Integrating femtosecond lasers with electron microscopies has enabled direct imaging of transient structures and morphologies of materials in real time and space. Here, we report the development of a laser-free ultrafast electron microscopy (UEM) offering the same capability but without requiring femtosecond lasers and intricate instrumental modifications. We create picosecond electron pulses for probing dynamic events by chopping a continuous beam with a radio frequency (RF)–driven pulser with the pulse repetition rate tunable from 100 MHz to 12 GHz. As a first application, we studied gigahertz electromagnetic wave propagation dynamics in an interdigitated comb structure. We reveal, on nanometer space and picosecond time scales, the transient oscillating electromagnetic field around the tines of the combs with time-resolved polarization, amplitude, and local field enhancement. This study demonstrates the feasibility of laser-free UEM in real-space visualization of dynamics for many research fields, especially the electrodynamics in devices associated with information processing technology.
This review explores magnetic field-driven emergent phenomena across various material systems, emphasizing the pivotal roles of magneto-optical and nanoscopy techniques. We examine fundamental aspects of Landau electrodynamics in both 2D and 3D systems, including quantum Hall and topological magnetoelectric effects in graphene and topological insulators. Particularly attention is given to magnetic excitations and magnetopolaritons, such as surface magnon polaritons, magnetoplasmons, and magnetoexcitons in novel quantum materials, including quantum magnets and hybrid heterostructures. Advanced imaging techniques, such as scattering-type scanning near-field optical microscopy (SNOM) and microwave impedance microscopy, are showcased for their capability to resolve these phenomena with microscopic and nanoscopic resolution. These insights are complemented by discussions of advanced experimental approaches, including cryogenic environments, ultrafast pump-probe techniques, and the integration of magnetic fields into near-field optical methodologies. We further investigate the potential of these imaging techniques for unraveling complex magnetic orders, quantum phases, and correlated electronic behaviors. Finally, we offer perspectives on future research directions and highlight emerging opportunities in the evolving field of optical magneto-nanoscopy.
Femtosecond photoexcitation of semiconducting materials leads to the generation of coherent acoustic phonons (CAPs), the behaviours of which are linked to intrinsic and engineered electronic, optical and structural properties. While often studied with pump-probe spectroscopic techniques, the influence of nanoscale structure and morphology on CAP dynamics can be challenging to resolve with these all-optical methods. Here, we used ultrafast electron microscopy (UEM) to resolve variations in CAP dynamics caused by differences in the degree of crystallinity in as-prepared and annealed GaAs lamellae. Following in situ femtosecond photoexcitation, we directly imaged the generation and propagation dynamics of hypersonic CAPs in a mostly amorphous and, following an in situ photothermal anneal, a mostly crystalline lamella. Subtle differences in both the initial hypersonic velocities and the asymptotic relaxation behaviours were resolved via construction of space-time contour plots from phonon wavefronts. Comparison to bulk sound velocities in crystalline and amorphous GaAs reveals the influence of the mixed amorphous-crystalline morphology on CAP dispersion behaviours. Further, an increase in the asymptotic velocity following annealing establishes the sensitivity of quantitative UEM imaging to both structural and compositional variations through differences in bonding and elasticity. Lastly, implications of extending the methods and results reported here to elucidating correlated electronic, optical and structural behaviours in semiconducting materials are discussed.
Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.
Catalyst-free, position-controlled indium arsenide (InAs) nanowires (NWs) of variable diameters were grown on Si (111) by selective-area epitaxy (SAE). Ultrafast pump-probe spectroscopy was conducted, from which carrier recombination mechanisms on the NW surface and interior were resolved and characterized. NWs grown using SAE demonstrated high optical quality, showing minority carrier lifetimes more than two-fold longer than that of the randomly-positioned (RP) NWs. The extracted SAE-InAs NW interior recombination lifetime was found to be as long as 7.2 ns , 13X longer than previous measurements on RP-NWs; and the surface recombination velocity 4154 cm · s - 1 . Transmission electron microscopy revealed a high density of stacking defects within the NWs, suggesting that interior recombination lifetime can be further increased by improving NW interior crystalline quality.
Time-resolved Kerr rotation microscopy is used to generate and measure spin valley polarization in MOCVD-grown monolayer tungsten diselenide (WSe 2 ). The Kerr signal reveals bi-exponential decay with time constants of 100 ps and 3 ns. Measurements are performed on several triangular flakes from the same growth cycle and reveal larger spin valley polarization near the edges of the flakes. This spatial dependence is observed across multiple WSe 2 flakes in the Kerr rotation measurements but not in the spatially resolved reflectivity or microphotoluminescence data. Time-resolved pump-probe overlap measurements further reveal that the Kerr signal’s spatial dependence is not due to spin diffusion on the nanosecond timescale.
Abstract Magneto-optical (MO) effects, viz. magnetically induced changes in light intensity or polarization upon reflection from or transmission through a magnetic sample, were discovered over a century and a half ago. Initially they played a crucially relevant role in unveiling the fundamentals of electromagnetism and quantum mechanics. A more broad-based relevance and wide-spread use of MO methods, however, remained quite limited until the 1960s due to a lack of suitable, reliable and easy-to-operate light sources. The advent of Laser technology and the availability of other novel light sources led to an enormous expansion of MO measurement techniques and applications that continues to this day (see section 1). The here-assembled roadmap article is intended to provide a meaningful survey over many of the most relevant recent developments, advances, and emerging research directions in a rather condensed form, so that readers can easily access a significant overview about this very dynamic research field. While light source technology and other experimental developments were crucial in the establishment of today’s magneto-optics, progress also relies on an ever-increasing theoretical understanding of MO effects from a quantum mechanical perspective (see section 2), as well as using electromagnetic theory and modelling approaches (see section 3) to enable quantitatively reliable predictions for ever more complex materials, metamaterials, and device geometries. The latest advances in established MO methodologies and especially the utilization of the MO Kerr effect (MOKE) are presented in sections 4 (MOKE spectroscopy), 5 (higher order MOKE effects), 6 (MOKE microscopy), 8 (high sensitivity MOKE), 9 (generalized MO ellipsometry), and 20 (Cotton–Mouton effect in two-dimensional materials). In addition, MO effects are now being investigated and utilized in spectral ranges, to which they originally seemed completely foreign, as those of synchrotron radiation x-rays (see section 14 on three-dimensional magnetic characterization and section 16 on light beams carrying orbital angular momentum) and, very recently, the terahertz (THz) regime (see section 18 on THz MOKE and section 19 on THz ellipsometry for electron paramagnetic resonance detection). Magneto-optics also demonstrates its strength in a unique way when combined with femtosecond laser pulses (see section 10 on ultrafast MOKE and section 15 on magneto-optics using x-ray free electron lasers), facilitating the very active field of time-resolved MO spectroscopy that enables investigations of phenomena like spin relaxation of non-equilibrium photoexcited carriers, transient modifications of ferromagnetic order, and photo-induced dynamic phase transitions, to name a few. Recent progress in nanoscience and nanotechnology, which is intimately linked to the achieved impressive ability to reliably fabricate materials and functional structures at the nanoscale, now enables the exploitation of strongly enhanced MO effects induced by light–matter interaction at the nanoscale (see section 12 on magnetoplasmonics and section 13 on MO metasurfaces). MO effects are also at the very heart of powerful magnetic characterization techniques like Brillouin light scattering and time-resolved pump-probe measurements for the study of spin waves (see section 7), their interactions with acoustic waves (see section 11), and ultra-sensitive magnetic field sensing applications based on nitrogen-vacancy centres in diamond (see section 17). Despite our best attempt to represent the field of magneto-optics accurately and do justice to all its novel developments and its diversity, the research area is so extensive and active that there remains great latitude in deciding what to include in an article of this sort, which in turn means that some areas might not be adequately represented here. However, we feel that the 20 sections that form this 2022 magneto-optics roadmap article, each written by experts in the field and addressing a specific subject on only two pages, provide an accurate snapshot of where this research field stands today. Correspondingly, it should act as a valuable reference point and guideline for emerging research directions in modern magneto-optics, as well as illustrate the directions this research field might take in the foreseeable future.
In this work, we report a method for measuring spot size and focusing conditions of the femtosecond (fs) excitation laser in situ at the specimen location in 4D ultrafast electron microscopy (UEM). The method makes use of threshold laser ablation behaviors of thin amorphous carbon membranes. For Gaussian beam profiles and for ablation threshold fluence values, we analytically derive expressions describing the relationship between ablated hole size and the actual laser spot size. Using these expressions, we developed experimental procedures for characterizing the shape and spot size of the pump beam at the specimen. We demonstrate the viability of the approach for incident excitation wavelengths of 343 nm and 515 nm, thus illustrating the applicability of the method to a range of optical wavelengths without modification. Further, we show that by measuring ablated hole size as a function of focusing condition, a full metrological characterization of the Gaussian beam propagation properties can be performed. Finally, we find good agreement for spot sizes determined with this method and with those determined by extrapolation from measurements taken outside the microscope column. Overall, this method is a simple, cost-effective means for accurate and precise determination of key pump-beam parameters in situ at the specimen location in UEM experiments.