Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 w/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 w/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky night monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs and CG4 was calculated using NREL equation. The calculated uncertainty (U95) of the PIRs varied from 2.43 w/m2 to 2.67 w/m2 , and for the CG4 equals 1.97 w/m2 with respect to SI.

absolute cavity pyrgeometer↗

Traceable Pyrgeometer Calibrations

This poster presents the development, implementation, and operation of the Broadband Outdoor Radiometer Calibrations (BORCAL) Longwave (LW) system at the Southern Great Plains Radiometric Calibration Facility for the calibration of pyrgeometers that provide traceability to the World Infrared Standard Group.

14 SOLAR ENERGY↗

Pyrgeometer Calibration for DOE-Atmospheric System Research Program Using NREL Method (Presentation)

Presented at the DOE-Atmospheric System Research Program, Science Team Meeting, 15-19 March 2010, Bethesda, Maryland. The presentation: Pyrgeometer Calibration for DOE-Atmospheric System Research program using NREL Method - was presented by Ibrahim Reda and Tom Stoffel on March 15, 2010 at the 2010 ASR Science Team Meeting. March 15-19, 2010, Bethesda, Maryland.

47 OTHER INSTRUMENTATION↗

Traceable Pyrgeometer Calibrations

This presentation provides a high-level overview of the progress on the Broadband Outdoor Radiometer Calibrations for all shortwave and longwave radiometers that are deployed by the Atmospheric Radiation Measurement program.

14 SOLAR ENERGY↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Secondary Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

Accurate measurements of broadband outdoor longwave irradiance are important for renewable energy applications and the study of the atmosphere and climate change. A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m 2 of those traceable to the World InfraRed Standard Group (WISG). This article describes a technique for validating this pyrgeometer calibration method using two Absolute Cavity Pyrgeometers (ACPs). The ACPs and pyrgeometer model PIR were deployed outdoors and the irradiance measured by the PIR was compared against the average irradiance measured by the two ACPs. The irradiance measured by the PIR was calculated using two equations, NREL equation and the Physikalisch Meteorologisches Observatorium Davos (PMOD) equation. The uncertainty with 95% confidence level ( U 95 ) of the irradiance measured by the PIR using NREL equation equaled ±3.51 W/m 2 with respect to SI and using PMOD equation U 95 equaled ±2.99 W/m 2 with respect to SI. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

54 ENVIRONMENTAL SCIENCES↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Transfer Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m2 of those traceable to the World InfraRed Standard Group (WISG). The ACPs and pyrgeometer model PIR were deployed outdoors, and the irradiance measured by the PIR was compared against the irradiance measured by ACP95F3. Based on the results it is possible to achieve an uncertainty of ± 3.51 W/m2. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

absolute cavity pyrgeometer↗

Results of Second Outdoor Comparison Between Absolute Cavity Pyrgeometer (ACP) and Infrared Integrating Sphere (IRIS) Radiometer at PMOD (Presentation)

The Absolute Cavity Pyrgeometer (ACP) and InfraRed Integrating Sphere radiometer (IRIS) are developed to establish a world reference for calibrating pyrgeometers with traceability to SI units. The two radiometers are un-windowed with negligible spectral dependence, and traceable to SI units through the temperature scale (ITS-90). The second outdoor comparison between the two designs was held from September 30 to October 11, 2013 at the Physikalisch-Metorologisches Observatorium Davos (PMOD). The difference between the irradiance measured by ACP and that of the IRIS was within 1 W/m2 (3 IRISs: PMOD + Australia + Germany). From the first and second comparisons, a difference of 4-6 W/m2 was observed between the irradiance measured by ACP&IRIS and that of the interim World Infrared Standard Group (WISG). This presentation includes results from the first and second comparison in an effort to establish the world reference for pyrgeometer calibrations, a key deliverable for the World Meteorological Organization (WMO), and the DOE-ASR.

47 OTHER INSTRUMENTATION↗

Results of First Outdoor Comparison Between Absolute Cavity Pyrgeometer (ACP) and Infrared Integrating Sphere (IRIS) Radiometer at PMOD (Presentation)

The ACP and IRIS are developed to establish a world reference for calibrating pyrgeometers with traceability to SI units. The two radiometers are unwindowed with negligible spectral dependence, and traceable to SI units through the temperature scale (ITS-90). The first outdoor comparison between the two designs was held from January 28 to February 8, 2013 at the Physikalisch-Metorologisches Observatorium Davos (PMOD). The difference between the irradiance measured by ACP and that of IRIS was within 1 W/m2. A difference of 5 W/m2 was observed between the irradiance measured by ACP&IRIS and that of the interim World Infrared Standard Group (WISG).

14 SOLAR ENERGY↗

Absolute Cavity Pyrgeometer to Measure the Absolute Outdoor Longwave Irradiance with Traceability to International System of Units, SI

This article describes a method of measuring the absolute outdoor longwave irradiance using an absolute cavity pyrgeometer (ACP), U.S. Patent application no. 13/049, 275. The ACP consists of domeless thermopile pyrgeometer, gold-plated concentrator, temperature controller, and data acquisition. The dome was removed from the pyrgeometer to remove errors associated with dome transmittance and the dome correction factor. To avoid thermal convection and wind effect errors resulting from using a domeless thermopile, the gold-plated concentrator was placed above the thermopile. The concentrator is a dual compound parabolic concentrator (CPC) with 180{sup o} view angle to measure the outdoor incoming longwave irradiance from the atmosphere. The incoming irradiance is reflected from the specular gold surface of the CPC and concentrated on the 11 mm diameter of the pyrgeometer's blackened thermopile. The CPC's interior surface design and the resulting cavitation result in a throughput value that was characterized by the National Institute of Standards and Technology. The ACP was installed horizontally outdoor on an aluminum plate connected to the temperature controller to control the pyrgeometer's case temperature. The responsivity of the pyrgeometer's thermopile detector was determined by lowering the case temperature and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The responsivity is then used to calculate the absolute atmospheric longwave irradiance with an uncertainty estimate (U{sub 95}) of {+-}3.96 W m{sup 02} with traceability to the International System of Units, SI. The measured irradiance was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the Interim World Infrared Standard Group, WISG. A total of 408 readings were collected over three different nights. The calculated irradiance measured by the ACP was 1.5 W/m{sup 2} lower than that measured by the two pyrgeometers that are traceable to WISG, with a standard deviation of {+-}0.7 W m{sup -2}. These results suggest that the ACP design might be used for addressing the need to improve the international reference for broadband outdoor longwave irradiance measurements.

14 SOLAR ENERGY↗

Uncertainty Estimates for SIRS, SKYRAD, & GNDRAD Data and Reprocessing the Pyrgeometer Data (Presentation)

The National Renewable Energy Laboratory (NREL) and the Atmospheric Radiation Measurement (ARM) Climate Research Facility work together in providing data from strategically located in situ measurement observatories around the world. Both work together in improving and developing new technologies that assist in acquiring high quality radiometric data. In this presentation we summarize the uncertainty estimates of the ARM data collected at the ARM Solar Infrared Radiation Station (SIRS), Sky Radiometers on Stand for Downwelling Radiation (SKYRAD), and Ground Radiometers on Stand for Upwelling Radiation (GNDRAD), which ultimately improve the existing radiometric data. Three studies are also included to show the difference between calibrating pyrgeometers (e.g., Eppley PIR) using the manufacturer blackbody versus the interim World Infrared Standard Group (WISG), a pyrgeometer aging study, and the sampling rate effect of correcting historical data.

14 SOLAR ENERGY↗

Absolute cavity pyrgeometer

Implementations of the present disclosure involve an apparatus and method to measure the long-wave irradiance of the atmosphere or long-wave source. The apparatus may involve a thermopile, a concentrator and temperature controller. The incoming long-wave irradiance may be reflected from the concentrator to a thermopile receiver located at the bottom of the concentrator to receive the reflected long-wave irradiance. In addition, the thermopile may be thermally connected to a temperature controller to control the device temperature. Through use of the apparatus, the long-wave irradiance of the atmosphere may be calculated from several measurements provided by the apparatus. In addition, the apparatus may provide an international standard of pyrgeometers' calibration that is traceable back to the International System of Units (SI) rather than to a blackbody atmospheric simulator.

47 OTHER INSTRUMENTATION↗

Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developed the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introducing an Absolute Cavity Pyrgeometer for Improving the Atmospheric Longwave Irradiance Measurement (Presentation)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer(ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined bylowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the WorldRadiation Center with traceability to the WISG. A total of 408 readings was collected over three different clear nights. The calculated irradiance measured by the ACP was 1.5 W/m2 lower than that measured by the two pyrgeometers that are traceable to WISG. Further development and characterization of the ACP might contribute to the effort of improving the uncertainty and traceability of WISG toSI.

47 OTHER INSTRUMENTATION↗

Introducing an Absolute Cavity Pyrgeometer (ACP) for Improving the Atmospheric Longwave Irradiance Measurement (Poster)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer(ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined bylowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the WorldRadiation Center with traceability to the WISG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the World Infrared Standard Group Field Campaign Report

The standard to which broadband infrared irradiance radiometers (pyrgeometers) are compared is called the World Infrared Standard Group (WISG), maintained in Davos, Switzerland, at the World Radiation Center. WISG consists of four pyrgeometers that were calibrated using the absolute sky-scanning radiometer (ASR; Philipona 2001). The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility has recently adopted this as its standard and all Eppley precision infrared radiometer (PIR) pyrgeometers in ARM are currently being calibrated by transfer calibrations from WISG. Subsequently, the ASR has fallen out of operation, Julian Gröbner (2012) developed the infrared integrating sphere (IRIS) radiometer, and Ibrahim Reda (2012) developed the absolute cavity pyrgeometer (ACP). The IRIS and ACP make absolute measurements of broadband downwelling infrared irradiance using different approaches. These two instruments have been compared to each other and to the WISG (Gröbner et al. 2014). The two newer instruments agreed within about 1 Wm-2 with each other, but not with the WISG, which was 2-5 Wm-2 lower depending on the column water vapor loading. Consequently, a case for changing the current WISG has been made by Gröbner and Reda, basing their suggestion on a total of nine hours of simultaneous IRIS and ACP comparison data as well as data from 177 clear-sky nights between the IRIS and WISG radiometers from October 2009 to December 2013 (Gröbner et al. 2014). These findings were later confirmed during the second International Pyrgeometer Comparison (IPgC-II) held in September/October 2015 at Physikalisch-Meteorologisches Observatorium Davos (PMOD)/World Radiation Center (WRC), bringing the total to about 20 hours of simultaneous ACP and IRIS measurements spread across two years and five days, in the mountainous environment of Davos. For this campaign, the WISG evaluation team deployed several instruments for absolute infrared radiation measurements and pyrgeometers that have been tied to the original standard (ASR) to ARM’s Southern Great Plains (SGP) atmospheric observatory in the fall of 2017. The experiment was carried out in two phases in order to increase the probability of collecting measurements at a range of water vapor column values, to which the measurements have shown some dependence. Phase 1 of the deployment ran from October 15 to 28, and Phase 2 ran from November 26 to December 9. Four redundant IRIS and two redundant ACP made coincident measurements during this time (the ASR no longer being available for comparison). The link to the WISG was provided by two pyrgeometers calibrated relative to the WISG prior to the campaign at SGP and also measuring coincidently with the two absolute radiometers. In addition, three of the original pyrgeometers directly tied to the original ASR were deployed. (See Figure 1 for instrument setup.) The experiment took place in the fall when water vapor columns were expected to range below and above the 1-cm level that is crucial for ferreting out the water vapor dependence of these measurements that has been noted in Gröbner et al. 2014 and other measurements. An additional source of longwave radiation flux observations was provided by the atmospheric emitted radiance interferometer (AERI). The AERI measures downwelling spectral radiance from 3.3 to 19 μm with a calibration that is better than 1% of the ambient radiance (Knuteson et al. 2004), and so serves as a potential source of evaluation for the WISG. The AERI’s field of view is 2 degrees, and is directed towards zenith. Earlier ARM projects led by Tony Clough as part of the Broadband Heating Rate Profile (BBHRP) effort demonstrated how to derive longwave flux from these zenith radiance observations.

AERI, instrument calibration, Southern Great Plain↗

Introducing an Absolute Cavity Pyrgeometer (ACP) for Improving the Atmospheric Longwave Irradiance Measurement (Poster)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer (ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined by lowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the WISG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical and traceable atmospheric longwave irradiance data sets with traceability to the International System of units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World InfraRed Standard Group (WISG) not to SI units. In 2013 the Absolute Cavity Pyrgeometer (ACP), [Reda et al., 2012] was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS) developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) [J. Grobner, 2012]. ACP and IRIS are absolute instruments traceable to SI units through the International Temperature Scale ITS-90. Results of six comparisons between ACP and IRIS at different location have shown that the irradiance measured by WISG pyrgeometers is underestimating clear-sky atmospheric longwave irradiance by 2 to 6 W/m 2 [Grobner et al., 2014]. Therefore, once the world reference is established with traceability to SI units the WISG would be corrected then used to calibrate field pyrgeometers with traceability to SI units. The described method below is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗