Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality control charts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

In-situ imaging of nucleation and growth of superlattices from nanoscale colloidal nanoparticles

Nanoparticle-based superlattices have attracted extensive research efforts due to their versatile composition and packing-dependent optical, magnetic, electronic, catalytic, mechanical properties. Yet the experimental understanding of the thermodynamics and pathways of the crystallization processes for these systems, which govern their ultimate morphology, size, and packing structure, has for long remained underexplored. Here, this minireview highlights recent integration of liquid-phase transmission electron microscopy, which allows for real-space, real-time direct imaging of the crystallization processes at the single-particle level, with simulation and the conceptual framework established by pioneers such as Dr. A. A. Chernov. Different aspects of superlattice formation were revealed by direct imaging for the first time, such as the existence of prenucleation precursor in nonclassical crystallization, surface energy-dependent growth, and coalescence, allowing for the charting of phase coordinates and thermodynamic quantities at the nanoscale. We discuss the similarities and differences of crystal growth behaviors in atomic and nanoparticle systems, as well as engineering opportunities to fashion, shape, and achieve quality control in superlattice formation from nanoparticles, for next-generation optical and mechanical metamaterials.

36 MATERIALS SCIENCE↗

Digital twins and deep learning segmentation of defects in monolayer MX 2 phases

Developing methods to understand and control defect formation in nanomaterials offers a promising route for materials discovery. Monolayer MX 2 phases represent a particularly compelling case for defect engineering of nanomaterials due to the large variability in their physical properties as different defects are introduced into their structure. However, effective identification and quantification of defects remain a challenge even as high-throughput scanning transmission electron microscopy methods improve. This study highlights the benefits of employing first principles calculations to produce digital twins for training deep learning segmentation models for defect identification in monolayer MX 2 phases. Around 600 defect structures were obtained using density functional theory calculations, with each monolayer MX 2 structure being subjected to multislice simulations for the purpose of generating the digital twins. Several deep learning segmentation architectures were trained on this dataset, and their performances evaluated under a variety of conditions such as recognizing defects in the presence of unidentified impurities, beam damage, grain boundaries, and with reduced image quality from low electron doses. Further, this digital twin approach allows benchmarking different deep learning architectures on a theory dataset, which enables the study of defect classification under a broad array of finely controlled conditions. It thus opens the door to resolving the underpinning physical reasons for model shortcomings and potentially chart paths forward for automated discovery of materials defect phases in experiments.

36 MATERIALS SCIENCE↗

Quantifying uncertainty in physics-based predictions of rare-isotope production cross sections via Bayesian-inspired model averaging across nuclear mass tables

Accurate prediction of fragmentation cross sections is essential for rare-isotope beam production, planning new-isotope searches, and designing experiments to study the most exotic regions of the nuclear chart. However, existing reaction models and phenomenological cross-section parametrizations often exhibit significant deviations over broad regions of mass and charge. In this work, a Bayesian-inspired model-averaging framework is developed to combine abrasion-ablation (AA) calculations based on multiple nuclear mass tables into a single statistically weighted estimate. For the calibrated systems, the model weights are assigned empirically according to the relative quality of fit to measured cross sections, thereby reducing systematic model bias while preserving the underlying physics content of the AA description. The weights are constrained using proton-rich fragmentation data for the 78 Kr and 124 Xe projectiles. The resulting parameter trends are then propagated to the 92 Mo and 144 Sm systems through a controlled scaling procedure. In the present implementation, the excitation-energy prescription is fixed, while the averaging is performed across nuclear-mass inputs; the framework provides both weighted cross sections and associated uncertainty estimates. Applied to proton-rich fragmentation, the present approach provides a practical basis for interpolation and limited extrapolation in regions relevant to rare-isotope production. The resulting predictions are used to assess the production of very proton-rich nuclei, and candidate new isotopes are discussed.

Bayesian methods↗

Convergent Manufacturing of Large-Scale Components for Nuclear Applications, via Additive Manufacturing and Powder Metallurgy Hot Isostatic Pressing

Powder metallurgy (PM)–hot isostatic pressing (PM-HIP) has long been recognized as a powerful route for producing fully dense, near net shape metallic components. By consolidating powders under high temperature and pressure, HIP provides isotropic properties, uniform microstructures, and scalability to complex geometries that are vital for sectors such as aerospace, energy, and nuclear power. Yet despite these advantages, the technology has remained constrained by costly trial and error canister fabrication, limitations of conventional forging, and incomplete knowledge about how the canister design influences final part properties. Additive manufacturing (AM), by contrast, thrives on design freedom and geometric flexibility but struggles with speed, scalability, and cost when applied to very large structures. The research presented in this report investigated how a convergent manufacturing approach, combining AM with PM-HIP, can merge the strengths of both technologies, leveraging AM’s flexibility for canister design and HIP’s consolidation capability to deliver reliable, large, and complex parts. The work progressed through three case studies that built on one another in scale and complexity. Small cylindrical canisters fabricated by conventional methods, laser powder bed fusion, and directed energy deposition were filled with stainless steel powders and subjected to HIP. The resulting parts demonstrated near-full density and mechanical properties on par with wrought stainless steel, showing for the first time that AM canisters can be a direct substitute for conventional ones without sacrificing quality. The next step involved a medium-scale, noncentrosymmetric T-valve, which is an enclosed, multibranch geometry that tested the limits of AM + PM-HIP integration. The T-valve achieved predictable shrinkage and uniform densification, confirming feasibility for enclosed designs. However, this study also revealed oxide inclusions and interfacial challenges at the AM + HIP boundary, underscoring the critical importance of controlling interface chemistry and employing robust, in situ strategies, such as melt pool monitoring and thermal monitoring, coupled with nondestructive evaluation techniques such as x-ray computed tomography. Finally, the effort culminated in fabricating a large-scale impeller weighing nearly 2000 lb and spanning 5 ft in diameter. Produced via multirobot wire arc AM and hot isostatic pressed to near-full density, the impeller validated industrial-scale feasibility. Predictive models closely matched experimental shrinkage, tensile properties were spatially uniform across the component, and the AM + PM-HIP interface proved mechanically sound despite the presence of oxide-decorated prior particle boundaries. This large-scale demonstration is a major milestone, showing that hybrid AM + PM‑HIP can reliably deliver components at reactor-relevant scales. Collectively, these studies charted a logical pathway: small-scale work built scientific confidence, medium-scale work highlighted opportunities and challenges, and large-scale work proved industrial impact. The overarching conclusion of this report is that AM + PM-HIP should not be seen as a replacement for forging but as a complementary pathway that provides the US with flexibility, resilience, and new options for manufacturing nuclear-grade components. Looking ahead, several directions emerge as critical to sustaining progress. Predictive modeling must become faster, more accessible, and more accurate, with digital twins and machine learning reducing reliance on trial and error. Powders and alloys must be optimized for HIP, with improved cleanliness, reduced oxides, and tailored chemistries that enhance creep, fatigue, and irradiation resistance. Interfaces between AM and HIP regions must be better engineered through coatings, machining strategies, and surface treatments to mitigate oxide formation and ensure reliable bonding to explore opportunities for HIP of targeted compositional parts, as well as multimaterial HIP cladding applications. Monitoring and nondestructive evaluation need to expand, incorporating multimodal sensors, x-ray computed tomography, and real-time data integration through platforms such as Pelican. At the same time, the pathway to industrial adoption requires techno-economic analysis, machinability studies, and qualification frameworks aligned with industry and regulatory standards. Finally, workforce and academic engagement must be strengthened. Programs that train technicians and engineers for US Navy and US Department of Energy manufacturing challenges should be paired with academic partnerships to support fundamental research, with open sharing of non-export-controlled data to accelerate innovation and build the next generation of experts. In conclusion, this report demonstrates that hybrid AM + PM-HIP is scientifically viable and strategically important. By combining the design agility of AM with the consolidation strength of HIP and embedding modeling, monitoring, and workforce development, this approach provided a transformative new capability for US manufacturing. The path forward is clear: hybrid AM + PM-HIP is not just a promising research direction but is also potentially an industrially relevant pathway that can reshape how nuclear-grade components are designed, qualified, and deployed.

36 MATERIALS SCIENCE↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Global Trends of ASME "N-Stamp" Certifications for Nuclear Component Vendors

Historically, nuclear component manufacturing vendors, from small businesses through large conglomerates, have felt compelled to obtain an American Society for Mechanical Engineers (ASME) Nuclear Certification, known colloquially as an "N-stamp", to assure supply chain quality standards that will be acceptable to regulators and safety concerns. Since the N-stamp quality standard is a U.S.-origin code, combined with the apparent decline in the U.S. nuclear industry alongside the growth of the Asian nuclear industry, there is the question of whether the rest of the world, including new entrants to the nuclear industry, also regard N-stamp as a needed certification. This study addresses this question through analysis of the entire N-stamp database of holders, and former holders, of N-stamp certificates of all types and for all regions worldwide from 1989-2020 (the dates available in the database). From this 30 years of data, we find that actually U.S.-based vendors still consistently obtain the largest number of N-stamps worldwide over all time periods, but also find that the countries participating in the N-stamp certification process has broadly expanded beyond just North America, Japan, S. Korea and Western Europe (the primary N-stamp recipients before the mid-2000's). We produced global heats maps and bar charts to illustrate our findings, as well as further investigation into why the data shows changes over time and region. We note that nuclear entities involved with Soviet-type reactors do not participate in the N-stamp process, but instead pursue the Russian version PNAE, which is substantially similar to the ASME code. We conclude that at least from the N-stamp database, the United States nuclear component manufacturing industry is alive and well, although there have been some consolidations, and that the ASME N-stamp appears to still be a valued certificate worldwide, including in China which now ranks second only to the United States in obtaining N-stamp certificates in recent years. We further note that the vendors of new reactor types, in particular High Temperature Gas-Cooled Reactors (HTGRs) and Small Modular Reactors (SMRs), are actively engaged with ASME (and other U.S.-based nuclear standards bodies such as the American Nuclear Society and Nuclear Energy Institute) to coordinate updates to the ASME N-Stamp criteria to ensure applicability of the code for these new designs. Implications of these findings include the following: The global use of the U.S.-origin N-stamp certification supports the view that, despite the decline of the U.S. nuclear industry, the United States remains an esteemed global leader in the area of nuclear safety. As the U.S. Government works to revitalize the U.S. nuclear industry, especially in the area of exports, it may be beneficial to leverage the global standing of the N-stamp certification. The findings indicate that the N-stamp database would be a useful tool for the U.S. Government to use to track the growth of the civil nuclear industry in foreign countries, under certain circumstances. The Excel-format N-stamp database produced as part of this study may be a useful tool for this purpose. N-stamp data may be a useful tool for foreign governments to use to identify nuclear manufacturers within their own country, especially to identify "targets" for outreach on nuclear export control compliance. The U.S. Government could carry this message to foreign partners during bilateral engagements or as part of Nuclear Suppliers Group (NSG) discussions on industry outreach.

42 ENGINEERING↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Final Report

The Graphite Technology Development Program ran a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. This report focuses on the fourth experiment, Advanced Graphite Creep 4 (AGC 4). The Advanced Reactor Development (ARD) Technology Development Office (TDO) Program for research and development activities require documentation of qualified monitoring data to design and license the first high-temperature reactor nuclear plant. Qualified data meets the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. AGC-4 began with Advanced Test Reactor (ATR) Cycle 157D on May 30, 2015. After irradiating the graphite for two cycles, the capsule was removed from the reactor after ATR Cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation was resumed with Cycle 162A on October 7, 2017 after the interfering experiment was removed from the reactor. AGC-4 irradiation completed by the end of Cycle 166B on January 10, 2020. Between Cycles 162A and 166B, AGC-4 capsule was removed from the reactor core during two Powered Axial Locator Mechanism (PALM) Cycles 163A and 165A to avoid overheating. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. A total of 9,256,184 out of all 11,167,213 temperature records (or 82.9%) are Qualified for use by the ARD Program and 1,911,029 missing values are Failed. Argon, helium, and total gas flow data were within expected ranges, except only eight out-of-range values occurred during outages. A total of 21,240,627 out of all 22,288,5103 gas flow rates (or 92.8%) are Qualified for use by the ARD Program and 1,644,476 are Failed records mostly due to missing values. Discharge gas line moisture values were consistently low during full ATR power, except for 162B, when moisture content was increasing to more than 200 ppmv by the end of this cycle. During outages, moisture content reached as high as 700 ppmv. 1,089,941 out of a total of 1,107,331 moisture values (or 98.4%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 17,390 missing moisture values are Failed. Graphite creep specimens were subjected to one of three loads: 393, 491, or 589 lbf. For a brief period during Cycle 157D between 12:19 on June 2, 2015, and 08:23 on June 11, 2015, the load cells were wired incorrectly, resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from Cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use but must be taken into account when analyzing the effect of load on creep. 6,095,728 out of a total of 6,403,985 moisture values (or 95.2%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 308,257 missing load values are Failed. Stack displacement increased consistently throughout the eight cycles, with total displacement reached highest value of 2.4 in by the end of irradiation. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed seven times throughout irradiation. All stacks were raised successfully each time. 4,744,974 out of a total of 6,094,513 displacement values (or 77.9%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 1,349,539 displacement values are Failed mostly due to missing values. Analyses were conducted on correlations between TCs to look for trends and step changes that might indicate instrument degradation or failure. Correlation analysis was used to identify instances when TCs form short circuits, referred to as virtual junctions, which result in TCs reporting temperatures from some location in the capsule other than the location where they were intended to read. No evidence of virtual junctions was found. Analyses were also conducted on control charts of temperature differences of between two TCs, which are expected to behave consistently throughout the entire irradiation period. Upward or downward trend over time indicates at least one TC in the pair was drifted. Examining control charts for all 66 possible pairs out of twelve TCs installed in the AGC-4 capsules reveal no clear drift failures occurred, except unstable behavior of two TCs in Zone 3, TC-7 and TC-8, over irradiation time. In conclus

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗