Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative limit of detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Infrared thermography NDT for in-situ defect detection in sandwich composite panel manufacturing

Composite manufacturing presents numerous challenges, as defects can arise from various sources throughout the process. In sandwich composite structures, the integration of a foam core introduces additional complexity and increases the likelihood of defect formation like delamination. To mitigate these issues and reduce the risk of future structural failures, in-situ monitoring during manufacturing is essential. This study investigates infrared (IR) thermography as a non-destructive technique for detecting manufacturing defects in foam-core sandwich composite panels under thermally excited conditions representative of in-situ processing. A stationary FLIR A8590 IR camera (640 × 512 pixels, 30Hz, 17mm lens, 9 ft stand-off distance) was used to monitor prefabricated panels subjected to controlled external heating simulating compression molding and resin cure exotherm. Interlaminar delamination defects with characteristic sizes ranging from 0.25 × 0.25in² to 5 × 5in² produced measurable surface temperature depressions of approximately 4–10°C during transient cooling, exceeding the effective noise floor of the camera by more than two standard deviations. Thicker laminates exhibited prolonged defect detectability windows due to increased thermal diffusion time. In contrast, embedded Teflon inclusions generated weak thermal contrasts of ≤ 3°C, approaching the measurement noise floor, due to limited thermal property contrast with the surrounding glass fiber composite. These results establish quantitative detectability limits for stationary thermographic inspection of sandwich composite panels under manufacturing-representative thermal cycles.

Barakat, Abdallah [ORNL] (ORCID:0000000296141398)↗

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

Proton nuclear magnetic resonance (1H NMR) of flammable organic chemicals in radioactive high–level supernatant waste at the Savannah River Site (SRS)

The Savannah River Site stores approximately 36 million gallons of radioactive and hazardous waste that contains approximately 245 million curies. The waste is sent through various chemical processes to reduce its volume and to separate various components. The facility plans to replace formic acid (a chemical used to reduce soluble mercury) with glycolic acid. Recycle solution with glycolate may flow back to the tank farm, where the glycolate can generate hydrogen gas by thermal and radiolytic mechanisms. The current analytical method for detecting glycolate (ion chromatography) in supernatant requires a large dilution to reduce interference from the nitrate anions. Hydrogen nuclear magnetic resonance is an analytical method that requires less sample dilution. It takes advantage of the CH 2 group in glycolate. Liquid samples were spiked with four different levels of glycolate to build a calibration line, as it is recommended in the standard addition method. The detection and quantitation limits determined were 1 and 5 ppm, respectively, for 32 scans, which is well below the process limit of 10 ppm. In one test, 800 scans of a supernatant spiked with 1 ppm glycolate resulted in a -CH 2 peak with a signal-to-noise ratio of 36.

1H↗

Determination of Seven Organic Impurities in FD&C Yellow No. 6 by Ultra-High-Performance Liquid Chromatography

The U.S. Food and Drug Administration (FDA) batch certifies FD&C Yellow No. 6 (Y6) to ensure that the color additive meets requirements published in the Code of Federal Regulations (CFR), including specifications for seven organic manufacturing impurities consisting of two intermediates, a reaction by-product, an impurity originating from an intermediate, and three subsidiary colors. An ultra-high-performance liquid chromatography (UHPLC) method was developed and validated for determining seven organic impurities in Y6. For comparison, the currently used high-performance liquid chromatography (HPLC) method was also validated. The new UHPLC method uses a 1.7 µm particle size biphenyl column with aqueous ammonium formate and methanol as eluants. Analytes are identified by comparing their retention times and UV-visible spectra to those of reference standards. Calibration is performed in the presence of the dye matrix and analyte levels are determined from their peak areas. UHPLC and HPLC validation studies obtained linear calibration curves and excellent values for limits of detection, limits of quantitation, recovery, repeatability, and intermediate precision for all analytes. Survey analyses of 30 samples using the UHPLC and HPLC methods yielded results that were consistent within experimental error; however, the UHPLC method provided more accurate results for two analytes that coelute using the HPLC method. The UHPLC method satisfies the accuracy and precision requisites for routine certification of Y6. The UHPLC method is faster and generates less waste than the HPLC method while delivering better sensitivity, separation, and accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Three RNA Extraction Kits with a 2019-nCoV Assay

The following characteristics of three RNA extraction kits (Norgen Biotek Total RNA Purification Kit, #17200; Bioneer AccuPrep Viral RNA Extraction Kit, #K-3033; and Promega Maxwell HT Viral TNA Kit, #AX2340) were evaluated: Limits of detection for quantitative synthetic RNA using the Centers for Disease Control and Prevention’s (CDC) 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel and the Applied Biosystems 7500 Fast Dx system; Limits of detection for positive clinical specimen using the Centers for Disease Control and Prevention’s (CDC) 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel and the Applied Biosystems 7500 Fast Dx system; Ability of the lysis buffers in each kit to inactivate the virus as measured by a cell-based infectivity assay.

60 APPLIED LIFE SCIENCES↗

Limits of Detection for EXAFS Characterization of Heterogeneous Single-Atom Catalysts

Single-atom catalysts (SACs), consisting of individual metal atoms dispersed on a support, attract attention due to their unique reactivity, efficient use of precious metals, and precise chemical tunability. Characterization of the metal species is crucial to substantiate structure–function relationships. Authors often use—and referees often require—X-ray absorption spectroscopy (XAS) data to prove the absence of clustered metal (or metal oxide) structures after pre-treatment and under in situ or operando conditions. However, there has been no critical assessment of the limitations of XAS in substantiating such conclusive statements, which is particularly important given the potential outsized influence of minority catalyst structures in dictating catalytic activity. Here, in this article, we quantitatively assess the detection limits of XAS to identify metal (or metal oxide) clusters in samples containing predominantly single atoms by modeling the extended X-ray absorption fine structure (EXAFS) of mixtures of structures. We identified that a significant fraction of clusters can coexist with SAC active sites (e.g., ~10% metallic Pt or ~40% oxidized Pt clusters in Pt/CeO 2 SACs), while eluding detection via EXAFS with any statistical significance. To generalize these conclusions, a descriptor-based screening of bulk metal oxides using a continuous Cauchy wavelet transform was proposed that suggests certain materials for which differentiating atomically dispersed metal species and metal oxide clusters would be infeasible by EXAFS (e.g., ReO x ). Based on this analysis, we suggest best practices for the study of SACs using EXAFS and provide recommendations to ensure that conclusions do not outpace the evidence used to support them. In this rapidly expanding research area, rigorous characterization will lead to greater understanding of the behavior of SACs and ultimately improved catalytic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method Validation Summary for L16.2 AD-ISO-0015 for ISO-17025 / NFAC Applications

Methods for the analysis of semi-volatile organic compounds are employed at Savannah River National Laboratory (SRNL) for routine and non-routine samples from tank waste, process control, waste acceptance, and a wide array of other process and research samples. A method has been developed by SRNL, based on existing methods for semi-volatile analysis, for the analysis of nitroaromatic high explosives by gas chromatography / mass spectrometry in soils and sediments. Relative to past work performed at SRNL on nitroaromatic explosives, this developed, optimized, and validated method can achieve lower limits of detection and quantitation, greater precision, lower bias, higher linearity, and accuracy across a greater linear range.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility of Metal Oxide Glasses and Polymer Membranes as Sorbents for Gaseous Oxidized Mercury

Mass spectrometry methods are currently under development by the atmospheric mercury (Hg) research community to elucidate the identity of atmospheric oxidized mercury (Hg II ) compounds. Due to high instrument detection limits, materials that can quantitatively preconcentrate atmospheric Hg II without facilitating compound-altering chemical reactions are needed to support these methods. Cation exchange membranes (CEM) and nylon membranes are currently used to preconcentrate ambient Hg II for concentration measurements and Hg II compound estimation, respectively. However, CEM and nylon membranes are poor candidates for observations by mass spectrometry methods due to release of interfering compounds upon heating; glasses do not have this problem. Here, three metal oxide glasses were explored as potential alternatives for Hg II preconcentration for future use with mass spectrometry methods: calcium phosphate (CaP), iron phosphate (FeP), and calcium aluminate (CaAl). The glasses demonstrated quantitative selective capture of HgBr 2 without capture of Hg 0 . Under ambient conditions, the CaP, FeP, and CaAl sorbed 36.4 ± 12.6% of the total HgII as the CEM. However, when Hg concentrations were normalized to surface area, CaP, FeP, and CaAl sorbed more HgBr 2 in the laboratory and ambient HgII compared to CEM. The CEM and CaP retained similar concentrations of HgBr 2 when preloaded samples were deployed in the field. Additionally, a permeation tube-based calibrator was used to load sorbents with HgBr 2 for investigation of HgII retention on CEM and thermal desorption profile changes on nylon membranes during active sampling. Nylon membranes were purchased from three vendors and used to compare HgBr 2 retention; a different HgBr 2 thermal desorption profile was achieved for each vendor’s nylon membrane.

Amides↗

Glycolate Analysis in Tank 22: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

Researchers developed and tested a range of techniques to support a low mg/L Limit of Quantitation (LOQ) of glycolate in radioactive Tank 22 waste solution by Ion Chromatography (IC) and by proton NMR. For the IC method, Dionex OnGuard II cartridges were tested as a means of removing alkali earth and transition metals that can interfere during ion chromatography applications especially when analyzing for low-concentration, chelating analytes. Additionally, concentrations of nitrate in the raw Tank 22 sample (5,000 to 10,000 mg/L) were managed by using reasonable levels of sample dilution. The resulting IC performance quality was enhanced by improving the baseline, increasing sensitivity [Limit of Quantitation (LOQ) of 12 mg/L and Limit of Detection (LOD) of 4.0 mg/L], and resolving analytes into well-defined Gaussian peaks when using the Dionex OnGuard II H⁺ cartridges to remove matrix interferences. High concentrations of nitrate limited the performance of the IC method. To achieve an acceptable baseline, samples with high nitrate content require more dilution, resulting in higher detection limits. Tests on samples with higher concentrations of nitrate (Tank 30 and 32 supernate with approximately 150000 mg/L nitrate) suggested that IC detection limits for glycolate in these samples would be > 500 mg/L. Thus, an LOQ of 12 mg/L is not feasible by this IC method on evaporator feed samples. An alternative method of glycolate analysis, using proton nuclear magnetic resonance (H NMR), was developed by the research team. In initial tests, the H NMR technique provided reasonable quantitation of glycolate in Tank 22 conditions by direct observation of the liquid. The H NMR method may provide improved detection limits for solutions with higher nitrate concentrations. We recommend further development of this analysis for high nitrate LWS samples such as evaporator feed and evaporator drop tank content. A method for pretreatment of samples using crystalline silicotitanate (CST) was developed and tested. The objective of the pretreatment was to facilitate analysis of samples with higher levels of radioactivity. The pretreatment did not influence the glycolate concentration in solution, and the pretreatment is projected to reduce Cs 137 activity in a sample by a factor of 16,200. The double strike CST pretreatment was demonstrated and would allow milliliters of higher activity samples to be transferred from the Shielded Cells and handled in a containment unit for glycolate analysis. The various studies validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. Based on the results, high quality glycolate analysis of Tank 22 is feasible down to approximately 12 mg/L, with the potential for broader applicability of the methods to other conditions in the Savannah River Site Liquid Waste System (LWS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative XPS of plutonium: Evaluation of the Pu4f peak shape, relative sensitivity factors and estimated detection limits

We report that high-resolution X-ray photoelectron spectra have been acquired from sputter cleaned and in situ oxidized samples of α-plutonium and a face-centred cubic δ-plutonium–gallium alloy. The differences in the Pu4f peak shape in these two materials have been investigated, and the poorly screened satellite peaks have been quantified. Curve fitting parameters for the Pu4p 3/2 , Pu4d 5/2 , Pu4f and Pu6p 3/2 photoelectron peaks are reported, and relative sensitivity factors have been determined. The Pu4f curve fit model has been applied to data acquired using different spectrometers and alloys. Examples of quantification of the plutonium spectra are provided and minimum detection limits are calculated for common impurities in plutonium metal.

36 MATERIALS SCIENCE↗

Ultrasonic Testing (UT) and Computed Tomography (CT) Comparative Scanning of Proposed Additive Manufacturing Reference Standard

This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.

36 MATERIALS SCIENCE↗

Intentional Uranium Tagging for Material Provenance and Pathway Forensics (LA19-Intentional-Forensics-NDD3Bb) (Annual Report for FY21)

This report describes the outcomes of the third and final year of a project to research the feasibility of tagging uranium materials, especially nuclear fuels. The experimental focus remained on metallic uranium forms under prospective surface and bulk tagging scenarios. Overall, the results showed that the tags could be successfully imparted and characterized in both as-built and degraded conditions. This was in line with expectations coming into this project, indicating promise for both surface and bulk tagging of metallic forms of uranium. Multiple surface tagging techniques and detection strategies were explored in FY21, with an emphasis on improving tag quality, readability, and detection in the field. Non-radioactive materials were used as a testbed. Selective deposition via laser beam was determined to be successful in imparting a readable titanium deposit on a stainless steel base plate, and can be read with high resolution characterization techniques (e.g., scanning electron microscopy) and field capable tools (e.g., eddy current testing). Other deposition techniques, such as selective deposition via electron beam and photoluminescent tags, were explored in FY21, and while success for these techniques would be dependent on additional work, these techniques showed potential for surface tagging applications. To survey bulk taggant elements for bulk uranium metal, 16 tagging elements were spread among 18 depleted uranium castings (4 baseline, 3 mix, 1 dilution, and 10 recycle). Most of these were made and characterized in FY21. Taggant acceptability was based upon manufacturability, detectability, and persistence from the standpoint of two detection options: bulk chemical analysis (for “chemical taggants”) and microstructural analysis (for “second phase taggants”). Taggant detection in both up-front manufacturing and in the face of “degradations” such as dilution, mixing, and recycling was generally good. Two independent laboratories carried out chemical analysis on most of the castings, and often at several locations within a casting, and the results are discussed. Scanning electron microscopy+EDS microanalysis revealed the second phases mostly contained the expected tagging elements. The shapes and 2 spatial distributions of these micron-sized carbides, oxides, and intermetallic particles offers opportunities for further science-based investigation and tagging optimization. Overall, V and Co currently appear as the best choices for chemical taggants while Al, Ti, Mn, Co, Pd, and Tb all look good as second phase taggants. The other elements considered here – Sc, Ni, Ge, Nb, Ce, Ta, W, Ir, and Au – while not being ruled out, require more study to become viable options. It is of special note that in the recycling study only one of the 12 elements fell out of detection even after 10 meltings, demonstrating their persistence. An Appendix tabulates all chemical analysis results to enable more quantitative and statistical studies of detection opportunities and limitations, as a part of a related project.

36 MATERIALS SCIENCE↗

Interrogating Proton Affinities of Organophosphonate Species Via Atmospheric Flow Tube Mass Spectrometry and Computational Methods

Within trace vapor analysis in environmental monitoring, defense, and industry, atmospheric flow tube mass spectrometry (AFT-MS) can fill a role that incorporates non-contact vapor analysis with the selectivity and low detection limits of mass spectrometry. AFT-MS has been applied to quantitating certain explosives by selective clustering with nitrate and more recently applied to detecting tributyl phosphate and dimethyl methylphosphonate as protonated species. Developing AFT-MS methods for organophosphorus species is appealing, given that this class of compounds includes a range of pollutants, chemical warfare agent (CWA) simulants, and CWA degradation products. A key aspect of targeting organophosphorus analytes has included the use of dopant ion chemistry to form adducts that impart additional analytical selectivity. The assessment of potential dopant molecules suited to enhance detection of these compounds is hindered by few published ion thermochemical properties for organophosphorus species, such as proton affinity, which can be used for approximating proton-bound dimer bond strength. As a preliminary investigation for the progression of sensing methods involving AFT-MS, we have applied both the extended kinetic method and computational approaches to eight organophosphorus CWA simulants to determine their respective gas-phase proton affinities. Notable observed trends, supported by computational efforts, include an increase in proton affinity as the alkyl chain lengths on the phosphonates increased. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Titanium dioxide and table sugar enhance the leaching of silver out of nanosilver packaging

We manufactured laboratory-scale food packages containing 2.57 ± 0.18 × 10 –3 wt% silver nanoparticles (AgNPs) and used them to show that table sugar (sucrose) and microcrystalline titanium dioxide (μTiO 2 ) enhance Ag migration from these packages and into aqueous food simulants. Ag migration into purified water was detected but was below the limit of ICP-MS quantitation, giving a range of potential Ag migration between 0.059 and 0.082 ng cm –2 packaging surface area. Ag migration into 9 wt% aqueous sucrose solution was 0.547 ± 0.084 ng cm –2 and migration into 9 wt% sucrose solution containing 0.01 wt% μTiO 2 was 0.724 ± 0.032 ng cm –2 . Total Ag migration into a 0.01 wt% μTiO 2 aqueous dispersion without sucrose was between 0.122 and 0.162 ng cm –2 , with upper and lower limits defined by the detectability of Ag in the supernatant phase of the simulant. If the midpoint of this range is taken as a baseline, these results imply that, compared to purified water, Ag migration was increased by approximately 10.3 times when the water simulant contained μTiO 2 and sucrose at commercially-relevant concentrations. Notably, the Ag migrated into water containing both ingredients exceeded the total Ag migrated into either of the single-ingredient simulants, pointing to a potential cooperative relationship between sucrose and μTiO 2 that possibly derives from binding and redox interactions between these two ingredients. Sucrose and μTiO 2 also both reduced a portion of migrated Ag + back into AgNPs, and μTiO 2 particles efficiently captured (>25% by mass) migrated Ag on their surfaces. Similar effects on migration were observed with nanocrystalline TiO 2 . Furthermore, these experiments are the first to show that TiO 2 particles exert a strong influence on the quantity and form of Ag that could migrate from AgNP-enabled packaging, suggesting that food formulations and interactions between individual food components may be important to consider when evaluating the fate of nanoparticles in these consumer applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

methamphetamine, cocaine, heroin, fentanyl, atmosp↗

National User Resource for Biological Accelerator Mass Spectrometry Annual Report

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science.

59 BASIC BIOLOGICAL SCIENCES↗