Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum cascade lasers modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Density-Matrix Model for Photon-Driven Transport in Quantum Cascade Lasers

In this report we develop a time-dependent density-matrix model to study photon-assisted (PA) electron transport in quantum cascade lasers. The Markovian equation of motion for the density matrix in the presence of an optical field is solved for an arbitrary field amplitude. Level-broadening terms emerge from microscopic Hamiltonians and supplant the need for empirical parameters that are often employed in related approaches. We show that, in quantum cascade lasers with diagonal design, photon resonances have a pronounced impact on electron dynamics around and above the lasing threshold, an effect that stems from the large spatial separation between the upper and lower lasing states. With the inclusion of PA tunneling, the calculated current density and output power are in good agreement with experiment.

36 MATERIALS SCIENCE↗

Covalent Drug Binding in Live Cells Monitored by Mid-Infrared Quantum Cascade Laser Spectroscopy: Photoactive Yellow Protein as a Model System

The detection of drug-target interactions in live cells enables analysis of therapeutic compounds in a native cellular environment. Recent advances in spectroscopy and molecular biology have facilitated the development of genetically encoded vibrational probes like nitriles that can sensitively report on molecular interactions. Nitriles are powerful tools for measuring electrostatic environments within condensed media like proteins, but such measurements in live cells have been hindered by low signal-to-noise ratios. In this study, we design a spectrometer based on a double-beam quantum cascade laser (QCL)-based transmission infrared (IR) source with balanced detection that can significantly enhance sensitivity to nitrile vibrational probes embedded in proteins within cells compared to a conventional FTIR spectrometer. Here, using this approach, we detect small-molecule binding in Escherichia coli, with particular focus on the interaction between para-Coumaric acid (pCA) and nitrile-incorporated photoactive yellow protein (PYP). This system effectively serves as a model for investigating covalent drug binding in a cellular environment. Notably, we observe large spectral shifts of up to 15 cm –1 for nitriles embedded in PYP between the unbound and drug-bound states directly within bacteria, in agreement with observations for purified proteins. Such large spectral shifts are ascribed to the changes in the hydrogen-bonding environment around the local environment of nitriles, accurately modeled through high-level molecular dynamics simulations using the AMOEBA force field. Our findings underscore the QCL spectrometer’s ability to enhance sensitivity for monitoring drug–protein interactions, offering new opportunities for advanced methodologies in drug development and biochemical research.

chromophores↗

Standoff Infrared Measurements of Chemical Plume Dynamics in Complex Terrain Using a Combination of Active Swept-ECQCL Laser Spectroscopy with Passive Hyperspectral Imaging

Chemical plume detection and modeling in complex terrain present numerous challenges. We present experimental results from outdoor releases of two chemical tracers (sulfur hexafluoride and Freon-152a) from different locations in mountainous terrain. Chemical plumes were detected using two standoff instruments collocated at a distance of 1.5 km from the plume releases. A passive long-wave infrared hyperspectral imaging system was used to show time- and space-resolved plume transport in regions near the source. An active infrared swept-wavelength external cavity quantum cascade laser system was used in a standoff configuration to measure quantitative chemical column densities with high time resolution and high sensitivity along a single measurement path. Both instruments provided chemical-specific detection of the plumes and provided complementary information over different temporal and spatial scales. The results show highly variable plume propagation dynamics near the release points, strongly dependent on the local topography and winds. Effects of plume stagnation, plume splitting, and plume mixing were all observed and are explained based on local topographic and wind conditions. Measured plume column densities at distances ~100 m from the release point show temporal fluctuations over ~1 s time scales and spatial variations over ~1 m length scales. The results highlight the need for high-speed and spatially resolved measurement techniques to provide validation data at the relevant spatial and temporal scales required for high-fidelity terrain-aware microscale plume propagation models.

47 OTHER INSTRUMENTATION↗

Design study of a combined interferometer and polarimeter for a high-field, compact tokamak

This article is the first design study of a combined interferometer and polarimeter on a compact, high-field, high-density, net-energy tokamak. Recent advances in superconducting technology have made possible designs for compact, high magnetic field fusion power plants, such as ARC [Sorbom et al., Fusion Eng. Des. 100, 378 (2015)], and experiments, such as SPARC [Greenwald et al., PSFC Report No. RR-18-2 (2018)]. These new designs create both challenges and opportunities for plasma diagnostics. The diagnostic proposed in this work, called InterPol, takes advantage of unique opportunities provided by high magnetic field and density to measure both line-averaged density and poloidal magnetic field with a single set of CO 2 and quantum cascade lasers. These measurements will be used for fast density feedback control, constraint of density and safety factor profiles, and density fluctuation measurements. Synthetic diagnostic testing using a model machine geometry, called MQ1 (Mission Q ≥ 1), and profiles simulated with Tokamak Simulation Code indicate that InterPol will be able to measure steady state density and poloidal magnetic field, as well as fluctuations caused by toroidal Alfven eigenmodes and other phenomena on a high-field compact tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shock tube investigation of high-temperature, extremely-rich oxidation of several co-optima biofuels for spark-ignition engines

To reduce the reliance on fossil fuels in the transportation sector and increase combustion efficiency, the Co-Optima initiative from US Department of Energy identified the top 10 biofuels for downsized, boosted, spark-ignition engines. Most of these biofuels have detailed reaction mechanisms available in literature developed based on studies at temperatures lower than 1700 K and an equivalence ratio of less than five. As such, the performance of these detailed mechanisms at high temperature and extremely rich conditions are unknown. It is important to validate kinetic mechanisms at these conditions because they are conducive to soot formation. Prediction of soot by chemical kinetic models relies on the prediction of underlying benchmark species like carbon monoxide and ethylene. In this work, we conduct high temperature (1700–2050 K) and high equivalence ratio(Φ=8.6) oxidation of these biofuels, namely 2,4,4-trimethyl-1-pentene (α-diisobutylene), ethanol, cyclopentanone, methyl acetate, and 2-methylfuran, blended in ethylene behind reflected shock waves at 4–4.7 atm pressure. Carbon monoxide and ethylene time histories are measured simultaneously using a continuous feedback quantum cascade laser near 4.9 µm and a tunable CO 2 gas laser at 10.532 nm, respectively. Results show that ethanol blend forms more carbon monoxide than other biofuels and consumes ethylene faster than the biofuel blends in the temperature range considered. Overall, the performance of different mechanisms in literature are evaluated against the experimental results. The novel reaction mechanism ‘the Co-Optima model’, which includes the sub mechanisms for all the biofuels in this study, was found to be the best mechanism for the experimental conditions studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Standoff Detection of Oil and Powder Mixtures at 12 Meters Using a Tunable Quantum Cascade Laser-Based System with a Close Focus Telescope and Uncooled Infrared Detector

We have designed and demonstrated a quantum cascade laser (QCL) based standoff system that utilizes an uncooled mercury cadmium telluride (MCT) detector with lock-in signal processing for chemical identification at a distance of 12.5 meters in indoor ambient light conditions. In the system, a tunable quad-QCL operating (1 MHz) in quasi-continuous wave mode between 8.45 and 10.03 μm (~1182 to 1000 cm –1 ) serves as the active mid-infrared source for remotely interrogating mineral, powder, and thin film oil samples including powder mixtures (6, 12.5, 25, and 50%) of crystalline quartz (SiO 2 ) in KBr. Light as reflected from a given sample is collected using a 10-inch (25.4 cm) Dall Kirkham telescope and coupled with ZnSe optics to an uncooled MCT detector. Furthermore, the mixture dependence of the highly transparent KBr and strongly absorbing quartz was found to fit a modified version of the Schatz reflectance model for compacted powder mixtures. All reflectance spectra reported are relative to an Au-coated diffuse reflector. A NIST traceable polystyrene standard reflector was also used to determine the QCL wavelength tuning range and calibration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wavelength Scaling of Widely-Tunable Terahertz Quantum-Cascade Metasurface Lasers

Terahertz (THz) external-cavity lasers based on quantum-cascade (QC) metasurfaces are emerging as widely-tunable, single-mode sources with the potential to cover the 1--6 THz range in discrete bands with milliwatt-level output power. By operating on an ultra-short cavity with a length on the order of the wavelength, the QC vertical-external-cavity surface-emitting-laser (VECSEL) architecture enables continuous, broadband tuning while producing high quality beam patterns and scalable power output. The methods and challenges for designing the metasurface at different frequencies are discussed. As the QC-VECSEL is scaled below 2 THz, the primary challenges are reduced gain from the QC active region, increased metasurface quality factor and its effect on tunable bandwidth, and larger power consumption due to a correspondingly scaled metasurface area. At frequencies above 4.5 THz, challenges arise from a reduced metasurface quality factor and the excess absorption that occurs from proximity to the Reststrahlen band. The results of four different devices — with center frequencies 1.8 THz, 2.8 THz, 3.5 THz, and 4.5 THz — are reported. Each device demonstrated at least 200 GHz of continuous single-mode tuning, with the largest being 650 GHz around 3.5 THz. The limitations of the tuning range are well modeled by a Fabry-Pérot cavity which accounts for the reflection phase of the metasurface and the effect of the metasurface quality factor on laser threshold. Lastly, the effect of different output couplers on device performance is studied, demonstrating a significant trade-off between the slope efficiency and tuning bandwidth.

47 OTHER INSTRUMENTATION↗

Time-resolved CO 2 , CO, and N 2 vibrational population measurements in Ns pulse discharge plasmas

Abstract Time-resolved CO 2 and N 2 vibrational populations and translational-rotational temperature are measured in a CO 2 –N 2 plasma sustained by a ns pulse discharge burst in plane-to-plane geometry. Time-resolved, absolute number density of CO generated in the plasma is also inferred from the experimental data. CO 2 and CO vibrational populations are measured by mid-IR, tunable quantum cascade laser absorption spectroscopy, and N 2 vibrational populations are measured by the ns broadband vibrational CARS. Transient excitation of N 2 and CO 2 asymmetric stretch vibrational energy modes is detected during the discharge burst. The time-resolved rate of CO generation does not correlate with N 2 or CO 2 ( ν 3 ) vibrational temperatures, indicating that CO 2 dissociation via the vibrational excitation is insignificant at the present conditions. The rate of CO generation decreases gradually during the discharge burst. The estimated specific energy cost of the CO product is close to that of N atoms in pure nitrogen, measured previously at similar operating conditions. Comparison of the experimental data with the kinetic modeling analysis indicates that CO 2 dissociation in collisions with electronically excited N 2 molecules is the dominant channel of CO generation at the present conditions, although the inferred CO yield in these processes is significantly lower than 1. The effect of vibrational energy transfer between N 2 and CO 2 on the plasma chemical processes is insignificant. The kinetic model underpredicts a rapid reduction of the N 2 and CO 2 ( ν 3 ) vibrational temperatures during the later half of the discharge burst and in the afterglow. V–T relaxation of N 2 by N and O atoms generated in the ns pulse discharge plasma does not affect the vibrational relaxation rate in a significant way. However, rapid V–T relaxation of CO 2 by O atoms has a significant effect on the relaxation rate. The difference between the experimental data and the modeling predictions may be due to the unknown scaling of the CO 2 –O V–T rates with the vibrational quantum number.

Physics↗

Frequency combs in optically injected terahertz ring quantum cascade lasers

Quantum cascade lasers (QCLs) have emerged as promising candidates for generating chip-scale frequency combs in mid-infrared and terahertz wavelengths. In this work, we demonstrate frequency comb formation in ring terahertz QCLs using the injection of light from a distributed feedback (DFB) laser. The DFB design frequency is chosen to match the modes of the ring cavity (near 3.3 THz), and light from the DFB is injected into the ring QCL via a bus waveguide. By controlling the power and frequency of the optical injection, we show that combs can be selectively formed and controlled in the ring cavity. Numerical modeling suggests that this comb is primarily frequency-modulated in character, with the injection serving to trigger comb formation. We also show that the ring can be used as a filter to control the output of the DFB QCL, potentially being of interest in terahertz photonic integrated circuits. Our work demonstrates that waveguide couplers are a compelling approach for injecting and extracting radiation from ring terahertz combs and offer exciting possibilities for the generation of new comb states in terahertz, such as frequency-modulated waves, solitons, and more.

47 OTHER INSTRUMENTATION↗

Laser absorption measurements of temperature, pressure, CO, and CO 2 at near-MHz rates in post-detonation fireballs with comparison to synthetic measurements

A laser absorption spectroscopy (LAS) diagnostic was used to obtain measurements of temperature, pressure, CO, and CO 2 at 500 kHz or 1 MHz in post-detonation fireballs produced by hemispherical samples of pentaerythritol tetranitrate (PETN). A quantum-cascade laser was scanned over multiple CO absorption transitions near 2008.5 cm −1 at 1 MHz, while an interband-cascade laser was scanned over a CO 2 absorption transition near 2394.8 cm −1 at 500 kHz. Light from each laser was combined onto a single path and passed through a detonation chamber approximately 83 mm above the 12-mm diameter hemispherical PETN charge. The CO and CO 2 absorption signals were post-processed to obtain time histories of temperature, pressure, species column pressures (P CO L, P CO2 L), and species column mole fractions (X CO L, X CO2 L). Additionally, schlieren imaging was performed simultaneously at 500 kHz to aid interpretation of the LAS measurements. Experimental and synthetic (i.e., CFD based) LAS measurements were compared to evaluate the accuracy of the CFD model and its ability to model the turbulent afterburning of the detonation products in air. In general, the experimental measurements exhibit reasonable agreement with the synthetic measurements at early times; thereby supporting the accuracy of the CFD model. Periods of disagreement between experimental and synthetic measurements at later times are most likely due to a reflected shock and detonator cavity jetting, which are not accounted for in the CFD model.

Schwartz, Charles J. [Purdue Univ., West Lafayette↗

Polarized QED cascades

By taking the spin and polarization of the electrons, positrons and photons into account in the strong-field QED processes of nonlinear Compton emission and pair production, we find that the growth rate of QED cascades in ultra-intense laser fields can be substantially reduced. While this means that fewer particles are produced, we also found them to be highly polarized. We further find that the high-energy tail of the particle spectra is polarized opposite to that expected from Sokolov–Ternov theory, which cannot be explained by just taking into account spin-asymmetries in the pair production process, but results significantly from 'spin-straggling'. We employ a kinetic equation approach for the electron, positron and photon distributions, each of them spin/polarization-resolved, with the QED effects of photon emission and pair production modelled by a spin/polarization dependent Boltzmann-type collision operator. For photon-seeded cascades, depending on the photon polarization, we find an excess or a shortage of particle production in the early stages of cascade development, which provides a path towards a controlled experiment. Throughout this paper we focus on rotating electric field configuration, which represent an idealized model and allows for a straightforward interpretation of the observed effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THz time-domain characterization of amplifying quantum-cascade metasurface

An amplifying quantum-cascade (QC) metasurface, the key component of the QC vertical-external-cavity surface-emitting-laser (VECSEL), is studied as a function of injected current density using reflection-mode terahertz time domain spectroscopy. Nearly perfect absorption is measured at zero bias, which is associated with the transition from the weak to strong coupling condition between the metasurface resonance and an intersubband transition within the QC material. An increase in reflectance is observed as the device is biased, both due to reduction in intersubband loss and the presence of intersubband gain. Significant phase modulation associated with the metasurface resonance is observed via electrical control, which may be useful for electrical tuning of QC-VECSEL. These results provide insight into the interaction between the intersubband QC-gain material and the metasurface and modify the design rules for QC-VECSELs for both biased and unbiased regions.

42 ENGINEERING↗