Search NASASearch

SEARCH · Search NASA

Results for “quantum noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optical communication with two-photon coherent stages. I - Quantum-state propagation and quantum-noise reduction

To determine the ultimate performance limitations imposed by quantum effects, it is also essential to consider optimum quantum-state generation. Certain 'generalized' coherent states of the radiation field possess novel quantum noise characteristics that offer the potential for greatly improved optical communications. These states have been called two-photon coherent states because they can be generated, in principle, by stimulated two-photon processes. The use of two-photon coherent state (TCS) radiation in free-space optical communications is considered. A simple theory of quantum state propagation is developed. The theory provides the basis for representing the free-space channel in a quantum-mechanical form convenient for communication analysis. The new theory is applied to TCS radiation.

Yuen, H. P.

High-sensitivity receiver for infrared laser communications.

Description of a high-sensitivity wide-bandwidth 10.6-micron heterodyne receiver for space and ground operational use. The receiver includes a cooled HgCdTe infrared mixer diode, a conical scanner for spatial tracking, an acquisition channel for spatial search and station alignment, and an automatic frequency-control channel to maintain a fixed laser frequency offset. The infrared mixer is designed to provide nearly quantum-noise-limited operation over an extended range of mixer temperature, bias voltage, and intermediate frequency. The resultant experimental receiver has a measured noise equivalent power of less than 10 to the minus 19th W/Hz over the 15- to 40-MHz i.f. band for mixer temperatures from 85 to 115 K, and less than 2 x 10 to the minus 19th W/Hz up to 140 K. Mixer 3-dB cutoff frequencies as high as 420 MHz were measured at a mixer temperature of 125 K. An analysis and engineering equations are given for receiver noise components, noise equivalent power, available mixer conversion gain, mixer transducer gain, and quantum-noise factor in terms of such factors as mixer parameters, quantum efficiency, mixer temperature, dynamic conductance, bias voltage, local oscillator power, and i.f. amplifier characteristics.

Peyton, B. J.

Coherent infrared receivers for laser communications and radar.

Review of infrared coherent detection processes. Three receivers are described which were built with the primary goal of exploiting quantum noise limited heterodyne detection in a spectral region where atmospheric transmission characteristics are favorable. The combination of high power, high efficiency carbon dioxide lasers, coherent heterodyne receivers with sensitivities approaching the quantum noise limit, and low-loss atmospheric transmission have presented new possibilities in infrared communications and radar. In particular, high sensitivity 10.6 micrometer heterodyne receivers with wide IF bandwidths have been developed.

Peyton, B.

Noise temperature and noise figure concepts: DC to light

The Deep Space Network is investigating the use of higher operational frequencies for improved performance. Noise temperature and noise figure concepts are used to describe the noise performance of these receiving systems. It is proposed to modify present noise temperature definitions for linear amplifiers so they will be valid over the range (hf/kT) 1 (hf/kT). This is important for systems operating at high frequencies and low noise temperatures, or systems requiring very accurate calibrations. The suggested definitions are such that for an ideal amplifier, T sub e = (hg/k) = T sub q and F = 1. These definitions revert to the present definition for (hf/kT) 1. Noise temperature calibrations are illustrated with a detailed example. These concepts are applied to system signal-to-noise analysis. The fundamental limit to a receiving system sensitivity is determined by the thermal noise of the source and the quantum noise limit of the receiver. The sensitivity of a receiving system consisting of an ideal linear amplifier with a 2.7 K source, degrades significantly at higher frequencies.

Stelzried, C. T.

The Deep Space Network: Noise temperature concepts, measurements, and performance

The use of higher operational frequencies is being investigated for improved performance of the Deep Space Network. Noise temperature and noise figure concepts are used to describe the noise performance of these receiving systems. The ultimate sensitivity of a linear receiving system is limited by the thermal noise of the source and the quantum noise of the receiver amplifier. The atmosphere, antenna and receiver amplifier of an Earth station receiving system are analyzed separately and as a system. Performance evaluation and error analysis techniques are investigated. System noise temperature and antenna gain parameters are combined to give an overall system figure of merit G/T. Radiometers are used to perform radio ""star'' antenna and system sensitivity calibrations. These are analyzed and the performance of several types compared to an idealized total power radiometer. The theory of radiative transfer is applicable to the analysis of transmission medium loss. A power series solution in terms of the transmission medium loss is given for the solution of the noise temperature contribution.

Stelzried, C. T.

Quantum issues in optical communication

Various approaches to the problem of controlling quantum noise, the dominant noise in an optical communications system, are discussed. It is shown that, no matter which way the problem is approached, there always remain uncertainties. These uncertainties exist because, to date, only very few communication problems have been solved in their full quantum form.

Kennedy, R. S.

High sensitivity infrared 10.6 micrometer heterodyne receiver development

The results are presented for a study on the design of an infrared 10.6-micrometer quantum-noise-limited optical receiver subsystem. Performance measurements of the HgCdTe photomixer preamplifier combination were carried out for photomixer temperatures up to 152 K and a photomixer frequency response of up to 420 MHz was obtained. Results of temperature and bias cycling of HgCdTe photomixers are reported. Design considerations for an operational 10.6 micrometer heterodyne receiver are presented. These consist of design data on required laser LO illumination, heat load levels for photomixer cooler, photomixer uniformity and the effects of photomixer impedance match on receiver sensitivity. Analysis and measurements of 10.6 micrometer heterodyne detection in an extrinsic photoconductive (p-type) HgCdTe photomixer are also presented.

Source record

Two-photon coherent states of the radiation field

The concept of a two-photon coherent state is introduced for applications in quantum optics. It is a simple generalization of the well-known minimum-uncertainty wave packets. The detailed properties of two-photon coherent states are developed and distinguished from ordinary coherent states. These two-photon coherent states are mathematically generated from coherent states through unitary operators associated with quadratic Hamiltonians. Physically they are the radiation states of ideal two-photon lasers operating far above threshold, according to the self-consistent-field approximation. The mean-square quantum noise behavior of these states, which is basically the same as those of minimum-uncertainty states, leads to applications not obtainable from coherent states or one-photon lasers. The essential behavior of two-photon coherent states is unchanged by small losses in the system. The counting rates or distributions these states generate in photocount experiments also reveal their difference from coherent states.

Yuen, H. P.

Infrared heterodyne spectrometer measurements of vertical profile of tropospheric ammonia and ozone

Remote sensing of the concentration and vertical distribution of atmospheric gases has been carried out using a dual CO2 laser multichannel infrared heterodyne spectrometer (IHS). The high specificity and nearly quantum-noise-limited sensitivity of the IHS provide the capability of scanning individual signature lines of selected atmospheric constituents in the 9 to 11 micron region. A comprehensive investigation of the spectral overlap between CO2 laser local oscillator transitions and selected atmospheric constituents was performed; measurements of the atmospheric absorption of solar radiation from the ground were carried out at selected laser transitions for ammonia and ozone.

Peyton, B. J.

Class of near-perfect coded apertures

Coded aperture imaging of gamma ray sources has long promised an improvement in the sensitivity of various detector systems. The promise has remained largely unfulfilled, however, for either one of two reasons. First, the encoding/decoding method produces artifacts, which even in the absence of quantum noise, restrict the quality of the reconstructed image. This is true of most correlation-type methods. Second, if the decoding procedure is of the deconvolution variety, small terms in the transfer function of the aperture can lead to excessive noise in the reconstructed image. It is proposed to circumvent both of these problems by use of a uniformly redundant array (URA) as the coded aperture in conjunction with a special correlation decoding method.

Cannon, T. M.