Search NASA⌕ Search

SEARCH · Search NASA

Results for “quartz crystal microbalance sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Mercury Detection Utilizing an Aquatic Animal as a Remote-Sensing Platform

Mercury species in open water, especially the accumulated methylmercury ion, pose a threat to fish and environment. Therefore, it is important to develop a small sensor package that can be integrated into a biotelemetry sensor carried by an aquatic animal, enhancing the ability to detect mercury contamination in large water areas. A quartz crystal microbalance (QCM) sensor using metal-organic framework (MOF) as sensing material was developed to detect mercury and methylmercury ions in real time based on acoustic wave perturbation. Thiol groups were introduced into the MOF UiO-66 through the organic linker to prepare the UiO-66-SH which was confirmed by infrared spectroscopy results. Batch adsorption experiments were conducted for the Hg 2+ , CH 3 Hg + , and Ca 2+ ions adsorption in the UiO-66-SH. The adsorption capacities of the mercury ions were more than an order of magnitude higher than those of the competing Ca 2+ ions at the same concentration. The frequency changes of the QCM sensor with the UiO-66-SH sensing film were an order of magnitude higher than those of the controlled baseline QCM sensor without a sensing film. Additionally, the frequency change can be tailored by adjusting the thickness of the MOF film and the adsorption properties of the sensing material. The sensor frequency change correlates well with ion adsorption capacities.

47 OTHER INSTRUMENTATION↗

Centimeter-Scale Pillared-Layer Metal–Organic Framework Thin Films Mediated by Hydroxy Double Salt Intermediates for CO 2 Sensor Applications

Fabrication of metal–organic framework (MOF) thin films over macroscopic surface areas is a subject of great interest for gas sensor application platforms such as optics and microelectronics. However, a direct synthesis of MOF films at ambient conditions, in particular pillared-layer MOF films due to their anisotropic structures, remains a significant challenge. Herein, we demonstrate for the first time a facile construction of dense and continuous pillared-layer MOF thin films on a centimeter scale via an aluminum-doped zinc oxide template and hydroxy double salt (HDS) intermediates at room temperature. A series of Cu(II)-based pillared MOFs with different 1,4-benzenedicarboxylic acid (bdc) ligands were explored for optimizing MOF film formation for CO 2 sensor applications. Nonpolar ligands with lower water solubility preferentially formed crystalline pillared MOF structures from HDS intermediates. A Cu 2 (ndc) 2 (dabco) (ndc = 1,4-naphthalene-bdc; dabco = 1,4-diazabicyclo[2.2.2]octane) MOF demonstrated the most dense and uniform film growth with micrometer thickness over one square centimeter area. This synthetic approach for growing Cu 2 (ndc) 2 (dabco) MOF thin films was successfully translated toward two sensing platforms: a quartz crystal microbalance and an optical fiber sensor. These Cu 2 (ndc) 2 (dabco) MOF-coated sensors displayed sensitivity toward CO 2 and response/recovery time on the scale of seconds, even at moderate humidity levels. Finally, this work provides a road map for producing continuous and anisotropic crystalline MOF thin films over a centimeter scale area on various substrates, which will greatly facilitate their utilization in MOF-based sensor devices, among other applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine Intelligence-Centered System for Automated Characterization of Functional Materials and Interfaces

Classic design of experiment relies on a time-intensive workflow that requires planning, data interpretation, and hypothesis building by experienced researchers. Here, in this paper, we describe an integrated, machine-intelligent experimental system which enables simultaneous dynamic tests of electrical, optical, gravimetric, and viscoelastic properties of materials under a programmable dynamic environment. Specially designed software controls the experiment and performs on-the-fly extensive data analysis and dynamic modeling, real-time iterative feedback for dynamic control of experimental conditions, and rapid visualization of experimental results. The system operates with minimal human intervention and enables time-efficient characterization of complex dynamic multifunctional environmental responses of materials with simultaneous data processing and analytics. The system provides a viable platform for artificial intelligence (AI)-centered material characterization, which, when coupled with an AI-controlled synthesis system, could lead to accelerated discovery of multifunctional materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas sensor and method of optimizing an array of gas sensors

A gas sensor (100,200) includes at least one sensor device including a surface acoustic wave (SAW) device (110) or a quartz crystal microbalance (QCM) device (210), and a layer of metal organic framework (MOF) material (120,220) disposed on each of the at least one sensor device. The at least one sensor device is structured to sense a change in mass of the MOF material.

Wilmer, Christopher E.↗

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection

Here, a straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH 2 , with a linear range of 0.2 to 30 μg/mL and detection limit of 0.073 μg/mL. A separate calibration curve (R = 0.9786) was obtained using spiked buffered solutions of dengue NS1 protein, which resulted in a linear range of 0.2 to 10 μg/mL and a detection limit of 0.056 μg/mL. The fabricated E-MIP sensor exhibited long-term stability, high sensitivity, and good selectivity towards the targeted molecules. These results indicated that the formation of the exact and stable cavity imprints in terms of size, shape, and functionalities was successful. In our future work, we aim to use our E-MIP sensors for NS1 detection in real-life samples such as serum and blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Delineating Confinement Regimes for Nafion Thin Films via Simultaneous QCM-D and Spectroscopic Ellipsometry

Proton-conducting ionomers used in electrodes of electrochemical devices form nanometer-scale films covering metallic catalyst surfaces, wherein they experience confinement and interfacial effects absent in the bulk polymer. This confinement alters the physical properties of the ionomer film, which is postulated to increase the density and is attributed to the transport limitations observed in fuel-cell electrodes. Despite studies showing reduced swelling, no systematic measurement has validated this phenomenon by demonstrating both densification and stiffening as the film gets thinner. Here, this study aims to fill this gap by reporting the humidity-driven changes in swelling, mass uptake, and density of Nafion ionomer films cast at varying thicknesses (10–320 nm) onto a gold-plated sensor. The films were simultaneously probed during humidification using spectroscopic ellipsometry (SE) and a quartz crystal microbalance with dissipation (QCM-D), which allowed for determination of the density and shear stiffness. The effects of confinement were prominently observed below ∼30 nm, with films showing increased density along with decreased swelling and mass uptake during hydration. In addition, the confined films show a negative excess volume upon initial water sorption, implying a larger proportion of absorbed water might bound to ionic groups in accord with notion of localized densification.

Espinet, Kevin B. [University of California, Berke↗

Detection of Chymotrypsin by Optical and Acoustic Methods

Chymotrypsin is an important proteolytic enzyme in the human digestive system that cleaves milk proteins through the hydrolysis reaction, making it an interesting subject to study the activity of milk proteases. In this work, we compared detection of chymotrypsin by spectrophotometric dynamic light scattering (DLS) and quartz crystal microbalance (QCM) methods and determined the limit of chymotrypsin detection (LOD), 0.15 ± 0.01 nM for spectrophotometric, 0.67 ± 0.05 nM for DLS and 1.40 ± 0.30 nM for QCM methods, respectively. The sensors are relatively cheap and are able to detect chymotrypsin in 3035 min. While the optical detection methods are simple to implement, the QCM method is more robust for sample preparation, and allows detection of chymotrypsin in non-transparent samples. We give an overview on methods and instruments for detection of chymotrypsin and other milk proteases.

59 BASIC BIOLOGICAL SCIENCES↗

Tuning gold-based surface functionalization for streptavidin detection: A combined simulative and experimental study

A rationally designed gold-functionalized surface capable of capturing a target protein is presented using the biotin–streptavidin pair as a proof-of-concept. We carried out multiscale simulations to shed light on the binding mechanism of streptavidin on four differently biotinylated surfaces. Brownian Dynamics simulations were used to reveal the preferred initial orientation of streptavidin over the surfaces, whereas classical molecular dynamics was used to refine the binding poses and to investigate the fundamental forces involved in binding, and the binding kinetics. We assessed the binding events and the stability of the streptavidin attachment through a quartz crystal microbalance with dissipation monitoring (QCM-D). The sensing element comprises of biotinylated polyethylene glycol chains grafted on the sensor’s gold surface via thiol-Au chemistry. Finally, we compared the results from experiments and simulations. We found that the confined biotin moieties can specifically capture streptavidin from the liquid phase and provide guidelines on how to exploit the microscopic parameters obtained from simulations to guide the design of further biosensors with enhanced sensitivity.

59 BASIC BIOLOGICAL SCIENCES↗

Orientation matters: Measuring the correct surface of polyamide membranes with quartz crystal microbalance

The surface of polyamide reverse osmosis (RO) membranes which regulates interface-dominated phenomena, such as partitioning and fouling, is the one facing the feed during operation. However, the opposite surface of the polyamide selective layer, the one facing the permeate and in contact with the polysulfone porous support, is commonly analyzed in quartz crystal microbalance (QCM) measurements due to limitations of state-of-the-art transfer methodologies. Such measurements on the back surface cannot be generalized because the polyamide layer is chemically and morphologically asymmetric. Herein, we introduce a simple method to coat QCM sensors with polyamide active layers in the correct orientation (i.e., exposing their front surface) and show that interface-dominated phenomena differ significantly between orientations. We start by describing a transfer protocol to coat any surface with a polyamide layer on its front surface orientation. We then systematically analyze the chemical and morphological differences between the two surfaces of the polyamide layer of a commercial RO membrane. Finally, we demonstrate that interface-dominated phenomena depend on the orientation by showing that NaCl partitioning at pH 6 was 1.3 to 2.3-fold higher on the front surface and that organic fouling with humic acid occurred at a lower rate on this surface. The new method presented herein enables measurements on the front surface of polyamide RO membranes, which should be the standard in any future QCM studies.

Fouling behavior↗

Reversible parts-per-trillion-level detection of perfluorooctane sulfonic acid in tap water using field-effect transistor sensors

Widespread, persistent and toxic per- and polyfluoroalkyl substances (PFAS) pose a major threat to water systems and human health. Current detection methods are relatively expensive, slow and complex, underscoring the need for more accessible alternatives to meet increasingly stringent PFAS regulations. Here, in this study, we present an ultrasensitive sensing platform for perfluorooctane sulfonic acid detection in tap water with a reporting limit ( ~ 250 parts per quadrillion) lower than the US Environmental Protection Agency’s regulatory standard (4 parts per trillion), using a remote gate field-effect transistor featuring β-cyclodextrin (β-CD)-modified reduced graphene oxide as the sensing membrane. The sensor exhibits excellent selectivity against common inorganic ions, natural organic matter and select organic pollutants in tap water. The reversible and rapid response ( < 2 min) indicates the potential of remote gate field-effect transistor for continuous in-line monitoring. Mechanistic studies using quartz crystal microbalance and molecular dynamics simulations reveal key roles of analyte adsorption and charge properties in sensing performance and offer insights for designing more selective PFAS capture probes.

Wang, Yuqin [University of Chicago, IL (United Sta↗

Accessibility and Mechanical Stability of Nanoporous Zinc Oxide and Aluminum Oxide Coatings Synthesized via Infiltration of Polymer Templates

The conformal nanoporous inorganic coatings with accessible pores that are stable under applied thermal and mechanical stresses represent an important class of materials used in the design of sensors, optical coatings, and biomedical systems. Here, we synthesize porous AlO x and ZnO coatings by the sequential infiltration synthesis (SIS) of two types of polymers that enable the design of porous conformal coatings—polymers of intrinsic microporosity (PIM) and block co-polymer (BCP) templates. Using quartz crystal microbalance (QCM), we show that alumina precursors infiltrate both polymer templates four times more efficiently than zinc oxide precursors. Using the quartz crystal microbalance (QCM) technique, we provide a comprehensive study on the room temperature accessibility to water and ethanol of pores in block copolymers (BCPs) and porous polymer templates using polystyrene-block-poly-4-vinyl pyridine (PS75-b-P4VP25) and polymers of intrinsic microporosity (PIM-1), polymer templates modified by swelling, and porous inorganic coatings such as AlO x and ZnO synthesized by SIS using such templates. Importantly, we demonstrate that no structural damage occurs in inorganic nanoporous AlO x and ZnO coatings synthesized via infiltration of the polymer templates during the water freezing/melting cycling tests, suggesting excellent mechanical stability of the coatings, even though the hardness of the inorganic nanoporous coating is affected by the polymer and precursor selections. We show that the hardness of the coatings is further improved by their annealing at 900 °C for 1 h, though for all the cases except ZnO obtained using the BCP template, this annealing has a negligible effect on the porosity of the material, as is confirmed by the consistency in the optical characteristics. These findings unravel new potential for the materials being used across various environment and temperature conditions.

36 MATERIALS SCIENCE↗

Application of Multiharmonic QCM-D for Detection of Plasmin at Hydrophobic Surfaces Modified by β-Casein

Plasmin protease plays an important role in many processes in living systems, including milk. Monitoring plasmin activity is important for control of the nutritional quality of milk and other dairy products. We designed a biosensor to detect the proteolytic activity of plasmin, using multiharmonic quartz crystal microbalance with dissipation (QCM-D). The β-casein immobilized on the hydrophobic surface of 1-dodecanethiol on the AT-cut quartz crystal was used to monitor plasmin activity. We demonstrated detection of plasmin in a concentration range of 0.1–20 nM, with the limit of detection about 0.13 ± 0.01 nM. The analysis of viscoelastic properties of the β-casein layer showed rapid changes of shear elasticity modulus, μ, and coefficient of viscosity, η, at plasmin sub-nanomolar concentrations, followed by modest changes at nanomolar concentrations, indicating multilayer architecture β-casein. A comparative analysis of viscoelastic properties of β-casein layers following plasmin and trypsin cleavage showed that the higher effect of trypsin was due to larger potential cleavage sites of β-casein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗