Large-scale fire suppression modeling of corrugated cardboard boxes on wood pallets in rack-storage configurations

In this study, the fire growth and suppression models in FireFOAM were validated for rack-storage commodities consisting of two solid fuels, namely corrugated cardboard boxes and hardwood pallets, which are referred to as Class 2 commodity. Validation experiments included two fire-growth and two fire-suppression configurations with different rack-storage array heights (3 and 5 tiers). In the suppression study, standard-response upright ceiling sprinklers (K-factor of 160 lpm/bar1/2) were used. The time-resolved chemical heat release rates obtained from the experiments were used to validate the fire growth model. The observed sprinkler activations and fire-spread patterns were used to validate the suppression model. This study identified that lateral flame spread is primarily enabled by flames impinging on the commodity's bottom surfaces. This study also showed that obstructions, such as wood pallets, can significantly impede convective and radiative heat transfer to the underside of the commodity, reducing the lateral flame spread rate. Fire-suppression modeling revealed that both surface water transport and lateral flame spread rates are important when predicting fire-suppression behavior. Therefore, as the rack-storage array height increases, so does the water transport time, which results in the fire becoming more difficult to control. Likewise, as the lateral spread rate increases, e.g., as occurs in the absence of wood pallets, fire-suppression also becomes more difficult.

Engineering↗

Agrivoltaic Racking Design Optimization Based on Wind and Snow Loading Finite Element Analysis

The racking structure of photovoltaic (PV) systems plays a critical role in ensuring the PV panels generate power properly as it provides integral structural support and sometimes even solar tracking ability. Distinct applications of PV systems require variations of racking structure designs, which yield different mechanical performances under external loading conditions from the environment, such as heavy wind and snow. Past works, such as Reddy et al. [1], have analyzed the pressure effects of wind and snow loading on the racking structure of conventional rooftop and utility PV systems, but there is little knowledge of how various agrivoltaic racking systems perform, in terms of stress and strain, under the same loading conditions. There is also a knowledge gap in the industry on a set of optimized agrivoltaic racking design standards. This study investigates the mechanical performance of various existing racking systems and proposes novel designs that are optimized for agrivoltaics applications under wind and snow loading.

Liao, Quanhuan↗

A Case For Intra-rack Resource Disaggregation in HPC

The expected halt of traditional technology scaling is motivating increased heterogeneity in high-performance computing (HPC) systems with the emergence of numerous specialized accelerators. As heterogeneity increases, so does the risk of underutilizing expensive hardware resources if we preserve today’s rigid node configuration and reservation strategies. This has sparked interest in resource disaggregation to enable finer-grain allocation of hardware resources to applications. However, there is currently no data-driven study of what range of disaggregation is appropriate in HPC. To that end, we perform a detailed analysis of key metrics sampled in NERSC’s Cori, a production HPC system that executes a diverse open-science HPC workload. In addition, we profile a variety of deep-learning applications to represent an emerging workload. We show that for a rack (cabinet) configuration and applications similar to Cori, a central processing unit with intra-rack disaggregation has a 99.5% probability to find all resources it requires inside its rack. In addition, ideal intra-rack resource disaggregation in Cori could reduce memory and NIC resources by 5.36% to 69.01% and still satisfy the worst-case average rack utilization.

97 MATHEMATICS AND COMPUTING↗

Eligibility Assessment of Items in the TA-60 Rack Assembly and Alignment Complex Legacy Storage Yard

The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (NA-LA), documented and evaluated seven structures in the Technical Area 60 (TA-60) Rack Assembly and Alignment Complex (RAAC) legacy storage yard at Los Alamos National Laboratory (LANL or Laboratory) for listing in the National Register of Historic Places (National Register). This documentation and evaluation was conducted in compliance with Section 106 of the National Historic Preservation Act of 1966, as amended; the Code of Federal Regulations (36 CFR 800); the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office and the Advisory Council on Historic Preservation Concerning Management of the Historic Properties at Los Alamos National Laboratory, Los Alamos New Mexico (PA)1; and A Plan for the Management of the Cultural Heritage at Los Alamos National Laboratory, New Mexico (LANL’s Cultural Resources Management Plan (2017). NA-LA makes the following National Register eligibility determinations: la cuna; the rack transporter (jeep, rack trailer, and steering dolly); the Mexia diagnostic rack; the Mexia device canister; the Mexia device mounting stand; and the Mexia target stand are eligible for listing in the National Register, and the second steering dolly is not eligible for listing in the National Register. This National Register evaluation was completed because LANL proposes to develop a consolidated waste facility in TA-60 next to the former RAAC. Across 3.56 acres, LANL proposes to construct an 8,000-square-foot, pre-engineered waste storage building; a 1,500-square-foot office/warehouse building; and 28,500 square feet of covered storage. The development will also include access control features and fencing, parking spaces, and utilities. Additionally, the Laboratory will continue to use the southern part of TA-60-0017 and reuse TA-60-0086 and TA-60-0324 in the development. The consolidated waste facility will operate as a central accumulation area—storing universal waste, mixed low-level (radioactive) waste, hazardous chemicals, and New Mexico special waste—until the waste can be shipped off site.

99 GENERAL AND MISCELLANEOUS↗

Lessons Learned "Establishing an Electrically Safe Work Condition" Specifically related to Racking Electrical Breakers

During low voltage electrical equipment maintenance, a bad breaker was identified. The breaker was racked out from the substation cubicle without following the hazardous energy control process identified in the Integrated Work Document (IWD). The IWD required the substation to be in an electrically safe work condition prior to racking the breaker. Per NFPA 70E requirements, electrical equipment shall be put into an electrically safe work condition before an employee performs work on or interacts with equipment in a manner that increases the likelihood of creating an arc flash. Racking in or out a breaker on an energized bus may increase the likelihood of creating an arc flash dependent on equipment conditions. A thorough risk assessment must be performed prior to performing such a task. The risk assessment determines the risk control measures to be put in place prior to performing the work. Electrical Safety Officers (ESO) can assist in performing risk assessments and incorporating risk control measures.

30 DIRECT ENERGY CONVERSION↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

97 MATHEMATICS AND COMPUTING↗

Electronics rack with compliant heat pipe

An electronics rack comprising a first cage, a first heat sink positioned at a rear and in thermal communication with the first cage, a second cage positioned above the first cage, and a second heat sink in thermal communication with the second cage. In another aspect, the present invention provides an electronics rack comprising a frame, a cage, a heat sink positioned at a rear of the frame, and a compliant thermal collector operatively positioned between the cage and the heat sink. The compliant thermal collector can comprise a heat pipe having a non-linear shape that facilitates flexing of the heat pipe to change the length of the thermal collector. The thermal collector advantageously includes a plurality of heat pipes and a contact bar coupling the plurality of heat pipes. Preferably, the rack further includes an adjusting mechanism (e.g., threaded rods) for adjusting a position of the contact bar.

Bilski, Jr., Walter John↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

Bermudez Rodriguez, Sergio A.↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

Bermudez Rodriguez, Sergio↗

Toughening mechanism of inter-critical heat-affected zone in a 690 MPa grade rack plate steel

Highlights: • Relationship between toughness and microstructure was confirmed. • The toughness of ICHAZ is higher than that of FGHAZ. • Fine bainitic microstructure in ICHAZ plays an important role on improving toughness. • The homogeneous distribution of dislocation and local strain facilitate the plastic deformation prior fracture. - Abstract: The inter-critical heat-affected zone (ICHAZ) and fine grain heat-affected zone (FGHAZ) of a 690 MPa grade rack plate steel were simulated by Gleeble3500 simulator. The toughening mechanism of ICHAZ was clarified by analyzing microstructural characteristics and instrumental Charpy impact tests. The study showed that the ICHAZ had higher toughness than FGHAZ. And the microstructure in FGHAZ was martensite, while bainitic microstructure was obtained in ICHAZ. Both the prior austenite grain size and effective grain size of ICHAZ were smaller than that of FGHAZ, which played an important role in improving the toughness of ICHAZ. It was found that the extensive plastic deformation prior fracture in ICHAZ could consume large energy during crack initiation and propagation. The large plastic deformation capacity of ICHAZ was related to the large fraction of large-angle boundaries and low dislocation density, as well as the homogeneous distribution of local strain and geometrically necessary dislocations.

36 MATERIALS SCIENCE↗

NREL Energy Performance Testing of Asetek's RackCDU System on a Single Rack of Twin Blade Servers: Cooperative Research and Development Final Report, CRADA Number CRD-13-518

The project will entail Asetek retrofitting 1 - 2 compute racks of servers at the National Renewable Energy Laboratory (NREL) to test and validate RackCDU's cooling performance and long-term reliability. The project will also entail measuring and reporting energy savings under a real workload by comparing total power input to the system vs. total heat removed by liquid and air. Direct measurements will be made to compare and contrast energy consumption and performance both before and after RackCDU installation. The scope of this project is strictly demonstration and feedback on the system. No development work will be performed under this CRADA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗

Equipment Qualification Report Environmental Qualification of GNB Absolyte Valve Regulated Lead Acid (VRLA) 1600 Ah100G33 Battery Rack Assembly (24590-QL-POA-EDB0-00001-11-00002_00A)

Greenberry Environmental Qualification Report 550001.001-35.0.5 provides basis for assignment of qualified life for: GNB Absolyte Valve Regulated Lead Acid (VRLA) 1600 Ah 100G33 Battery Rack Assembly in accordance with the requirements specified 24590-WTP-3PS-G000-T0015 (Rev 2) and Environmental Qualification Plan 550001.001-35.0.1 (Rev. 3). The equipment qualification basis represents the most conservative capability of the equipment. The analysis performed for the qualification is not less conservative than the bounding environmental conditions detailed in contract documents issued to Greenberry in contract 24509-QL-POA-EDB0-00001 Rev.0. The qualified life of 10 years has been established based upon an end-condition objective of the equipment condition indicators that correlate to the ability of equipment to perform its safety function. The VRLA Battery Cell Assembly was aged by 10 years (minimum) in accordance with conditions specified by Bechtel Equipment Qualification Datasheet 24590-LAW-EUQ-UPE 00003 Rev. 3 and the process conditions specified by the Instrument Data Sheet 24590-LAW EUD-UPE-00009 Rev. 2. Greenberry Industrial has contracted with GNB Industrial Battery Co located at 4115 S Zero St, Fort Smith, AR 72908 to perform age conditioning, monitoring, and capacity testing in accordance with Environmental Qualification Plan 550001.001-35.0.1 Rev. 1. The required process at the stated conditions set by the parameters established by the plan were completed satisfactorily. The details of the of the test process observed by Greenberry is detailed in the attached Seismic Test Log 550001.001-7.0.3, including examples of the objective evidence collected during the qualification process.

54 ENVIRONMENTAL SCIENCES↗

Challenges for Megawatt-Scale Artificial Intelligence Rack Infrastructure

As artificial intelligence (AI) computing densities continue to increase, industry is pursuing megawatt-scale rack architectures that require tightly coordinated advances in electrical power delivery, thermal management, operations, and infrastructure integration. This document summarizes the primary technical challenges for achieving this target.

Nawaz, Kashif [ORNL] (ORCID:0000000251612491)↗

Examination of an Electrified Bar Rack Fish Guidance Device for Hydropower Turbines

The potential of hydropower turbines to cause injury or mortality to fish is a concern. To reduce this risk, engineers have begun to develop a conically arranged, cantilevered electrified bar rack (Center Sender). This device is proposed to be mounted within the intake of a turbine, guiding downstream-passing fish towards the center of the turbine where blade velocities are lower and blades are thicker, likely reducing the potential for fish to be injured. A simplified version was installed in a flume for testing with Rainbow trout (Oncorhynchus mykiss) while examining several parameters such as electrification, bar spacing, bar angle, and water velocity. The most effective settings were observed to be a water velocity of 1.0 m s -1 with all bars installed at an angle of 40° with electrification on. Other combinations were still effective but had varying results. A minimal proportion (2.3%) of fish passed at lower velocities with bars electrified and mounted at 20°, suggesting that while it functions well as a guidance device in high-velocity conditions, it performs better as a barrier at lower velocities. The study suggests that the Center Sender has promising potential for reducing the harmful effects of hydropower turbines on fish populations by guiding them away from stressors. Further research is needed, but current results encourage its potential use in hydropower operations.

13 HYDRO ENERGY↗

Whisper Sensitivity Study of the NMIS ATR Fuel Storage Racks

A sensitivity study was performed on the NMIS ATR fuel storage racks as part of the CSE to implement the boron-carbide aluminum composite shelves. Whisper was used as part of this study to find applicable benchmarks for validation purposes. It was found that Whisper is very useful in finding benchmarks for the most sensitive isotopes in a problem but can be used to search for sensitivities related to specific isotopes. Whisper gave confidence in the NMIS validation and helped the author learn details about the physics of the problem as well.

99 GENERAL AND MISCELLANEOUS↗

Spent fuel storage rack

A system for storing nuclear fuel assemblies includes a plurality of cells housed within a support structure. A first cell may house a first fuel assembly and a second cell may house a second fuel assembly. A plurality of compartments separate the plurality of cells and provide passageways for coolant entering a bottom end of the support structure to remove heat from the nuclear fuel assemblies. A first perforation transfers coolant between the first cell and one or more of the compartments, and a second perforation transfers coolant between the second cell and the one or more compartments. At least a portion of the coolant entering the bottom end of the support structure is transferred between the plurality of cells and the plurality of compartments. Two or more fuel storage racks may be stacked together in alternating fuel patterns to facilitate cooling the fuel assemblies with liquid or air.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗