Search NASA⌕ Search

SEARCH · Search NASA

Results for “racking test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Test Rack Development for Extended Operation of Advanced Stirling Convertors at NASA Glenn Research Center

The U.S. Department of Energy, Lockheed Martin Space Systems Company, Sunpower Inc., and NASA Glenn Research Center (GRC) have been developing an Advanced Stirling Radioisotope Generator (ASRG) for use as a power system on space science missions. This generator will make use of free-piston Stirling convertors to achieve higher conversion efficiency than with currently available alternatives. One part of NASA GRC's support of ASRG development includes extended operation testing of Advanced Stirling Convertors (ASCs) developed by Sunpower Inc. and GRC. The ASC consists of a free-piston Stirling engine integrated with a linear alternator. NASA GRC has been building test facilities to support extended operation of the ASCs for several years. Operation of the convertors in the test facility provides convertor performance data over an extended period of time. One part of the test facility is the test rack, which provides a means for data collection, convertor control, and safe operation. Over the years, the test rack requirements have changed. The initial ASC test rack utilized an alternating-current (AC) bus for convertor control; the ASRG Engineering Unit (EU) test rack can operate with AC bus control or with an ASC Control Unit (ACU). A new test rack is being developed to support extended operation of the ASC-E2s with higher standards of documentation, component selection, and assembly practices. This paper discusses the differences among the ASC, ASRG EU, and ASC-E2 test racks.

Dugala, Gina M.↗

Test Rack Development for Extended Operation of Advanced Stirling Convertors at NASA Glenn Research Center

The U.S. Department of Energy (DOE), Lockheed Martin Space Company (LMSC), Sun power Inc., and NASA Glenn Research Center (GRC) have been developing an Advanced Stirling Radioisotope Generator (ASRG) for use as a power system on space science missions. This generator will make use of free-piston Stirling convertors to achieve higher conversion efficiency than currently available alternatives. NASA GRC's support of ASRG development includes extended operation testing of Advanced Stirling Convertors (ASCs) developed by Sunpower Inc. In the past year, NASA GRC has been building a test facility to support extended operation of a pair of engineering level ASCs. Operation of the convertors in the test facility provides convertor performance data over an extended period of time. Mechanical support hardware, data acquisition software, and an instrumentation rack were developed to prepare the pair of convertors for continuous extended operation. Short-term tests were performed to gather baseline performance data before extended operation was initiated. These tests included workmanship vibration, insulation thermal loss characterization, low-temperature checkout, and fUll-power operation. Hardware and software features are implemented to ensure reliability of support systems. This paper discusses the mechanical support hardware, instrumentation rack, data acquisition software, short-term tests, and safety features designed to support continuous unattended operation of a pair of ASCs.

Dugala, Gina M.↗

Earth Viewing Applications Laboratory (EVAL). Dedicated payload, standard test rack payload, sensor modifications

The preliminary analysis of strawman earth-viewing shuttle sortie payloads begun with the partial spacelab payload was analyzed. The payloads analyzed represent the two extremes of shuttle sortie application payloads: a full shuttle sortie payload dedicated to earth-viewing applications, and a small structure payload which can fly on a space available basis with another primary shuttle payload such as a free flying satellite. The intent of the dedicated mission analysis was to configure an ambitious, but feasible, payload; which, while rich in scientific return, would also stress the system and reveal any deficiences or problem areas in mission planning, support equipment, and operations. Conversely, the intent of the small structure payload was to demonstrate the ease with which a small, simple, flexible payload can be accommodated on shuttle flights.

Source record↗

CM-2 Environmental / Modal Testing of Spacehab Racks

Combined environmental/modal vibration testing has been implemented at the NASA Glenn Research Center's Structural Dynamics Laboratory. The benefits of combined vibration testing are that it facilitates test article modal characterization and vibration qualification testing. The Combustion Module-2 (CM-2) is a space experiment that launches on Shuttle mission STS 107 in the SPACEHAB Research Double Module. The CM-2 flight hardware is integrated into a SPACEHAB single and double rack. CM-2 rack level combined vibration testing was recently completed on a shaker table to characterize the structure's modal response and verify the random vibration response. Control accelerometers and limit force gauges, located between the fixture and rack interface, were used to verify the input excitation. Results of the testing were used to verify the loads and environments for flight on the Shuttle.

McNelis, Mark E.↗

CM-2 Environmental/Modal Testing of SPACEHAB Racks

Combined environmental/modal vibration testing has been implemented at the NASA Glenn Research Center's Structural Dynamics Laboratory. The benefits of combined vibration testing are that it facilitates test article modal characterization and vibration qualification testing. The Combustion Module-2 (CM-2) is a space experiment that will launch on shuttle mission STS-107 in the SPACEHAB Research Double Module. The CM-2 flight hardware is integrated into a SPACEHAB single and double rack. CM-2 rack-level combined vibration testing was recently completed on a shaker table to characterize the structure's modal response and verify the random vibration response. Control accelerometers and limit force gauges, located between the fixture and rack interface, were used to verify the input excitation. Results of the testing were used to verify the loads and environments for flight on the shuttles.

McNelis, Mark E.↗

Continuation of surge life of transient voltage suppressor

Efforts expended in testing, analyzing and the development of a meaningful definition of the mean number of peak pulses before failure (mp2bf) levels of a family of transient voltage suppressor devices were documented. Tests were done to determine the ability of the transient suppressor to effectively and reliably protect against severe short term, millisecond range, and transient voltages of the types resulting from inductive load switching and induced lightning. Existing pulse testing instrumentation was utilized, interfaced to an automatic sequencing test rack accommodating up to 50 devices. Tests were performed in step stress increments of 25% beginning at 25% and extending thru 100% rated I(pp) for each voltage category. The four voltage types test were the 6.8V, 33V, 91V, and 190V. Engineering efforts addressed the problem of improving the reliability of the 190V types.

Clark, O. M.↗

Testing Plant Responses to Rarified Atmospheres for Inflatable Greenhouses

Reduced atmospheric pressures will likely be used to minimize mass and engineering requirements for plant growth habitats used in extraterrestrial applications. A chamber with high vacuum capability was used to design and begin construction of a system for testing plant responses to reduced pressure atmospheres. Several preliminary tests were conducted to evaluate chamber suitability for plant tests and to determine performance of thermal and vacuum systems at ambient and reduced pressure atmospheres down to 0.1 atm. The first tests consisted of measurements of internal gas volume and leakage rate. The method for volume determination was quite sensitive and will be needed for plant gas exchange measurements and calculations. This information will also be used in conjunction with the leak rate. Measured leak rates on the order of 0.46 mm Hg/min at 76 mm Hg pressure are low enough to conduct sensitive carbon dioxide exchange rate measurements at reduced pressure given an adequate plant sample (0.5 to 1.0 sq m area). A test rack with lighting provided by three high-pressure sodium vapor lamps was built to accommodate both short-term and long-term plant responses. Initial short-term experiments with lettuce showed that a pressure of 77 mm Hg resulted in a 6.1-fold increase in the rate of water loss compared to water loss at ambient pressure. Plants were severely wilted after 30 minutes exposure to 77 mm Hg. Water loss was found to be inversely correlated with atmospheric pressure over the range of pressures from 0.2 to 1.0 atm; the rate of water loss at 0.2 atm was 4.3 times higher than water loss at ambient pressure. Older leaves showed moderate wilting during exposure to 156 mm Hg, but those exposed to 345 mm, Hg remained turgid. Results suggest a reduced atmospheric pressure limit of 0.2 to 0.3 atm for lettuce grown in a solid medium. Follow-up experiments with carbon dioxide control and control at high relative humidity (> 90 %) will be needed to further confirm and define safe reduced pressure limits that are feasible for plant tolerance and growth.

Corey, Kenneth A.↗

Plant Responses to Rarified Atmospheres

Reduced atmospheric pressures will likely be used to minimize mass and engineering requirements for plant growth habitats used in extraterrestrial applications. This report provides a brief survey of key literature related to responses of plants to atmospheric variables and a broad rationale for designing minimal atmospheres for future plant growth structures on the Martian surface. The literature and recent work suggest that atmospheric pressure limits for normal plant function are likely to be 10 kPa or perhaps slightly lower. At Kennedy Space Center, a chamber with high vacuum capability was used to design and begin construction of a system for testing plant responses to reduced pressure atmospheres. A test rack with lighting provided by 3, high-pressure sodium vapor lamps was built to conduct measurements of short-term plant responses. Initial experiments with lettuce showed that a pressure of 10 kPa resulted in a 6.1-fold increase in the rate of water loss compared to water loss at ambient pressure (101 kPa).

Corey, Kenneth A.↗

Development and testing of the rack insertion device

Installing and removing experiment racks in a Space Station Logistics Module will become a repetitive operation at Kennedy Space Center (KSC) in the near future. A Rack Insertion Device (RID) consisting of an Extendible Boom, End Effector, and Positioning Base is being developed for the task. This paper discusses the key elements of the RlD's function and design. Prototype test results for the RlD's Extendible Boom and End Effector are presented. Also discussed are future end effectors that will further enhance the RlD's Space Station processing capability.

Strickland, G. Scott↗

Heated Rack For Weathering Tests

Outdoor photothermal aging reactor (OPTAR) simple device exposing polymer specimens to both heat and natural sunlight. Intended to provide accelerated aging data for service life of polymers used in outdoor environments. In principle, OPTAR accelerates (but does not initiate) degradation of polymers resulting from sunlight and other weathering effect (eg. rain, wind, ozone). Aging of tested material accelerated, but under almost-natural conditions.

Cuddihy, Edward F.↗

Design, Fabrication, and Testing of a Composite Rack Prototype in Support of the Deep Space Habitat Program

In support of the Deep Space Habitat project a number of composite rack prototypes were developed, designed, fabricated and tested to various extents ( with the International Standard Payload Rack configuration, or crew quarters, as a baseline). This paper focuses specifically on a composite rack prototype with a direct tie in to Space Station hardware. The outlined prototype is an all composite construction, excluding metallic fasteners, washers, and their associated inserts. The rack utilizes braided carbon composite tubing for the frame with the sidewalls, backwall and flooring sections utilizing aircraft grade composite honeycomb sandwich panels. Novel additively manufactured thermoplastic joints and tube inserts were also developed in support of this effort. Joint and tube insert screening tests were conducted at a preliminary level. The screening tests allowed for modification, and enhancement, of the fabrication and design approaches, which will be outlined. The initial joint tests did not include mechanical fasteners. Adhesives were utilized at the joint to composite tube interfaces, along with mechanical fasteners during final fabrication (thus creating a stronger joint than the adhesive only variant). In general the prototype was focused on a potential in-space assembly approach, or kit-of-parts construction concept, which would not necessarily require the inclusion of an adhesive in the joint regions. However, given the tie in to legacy Station hardware (and potential flight loads with imbedded hardware mass loadings), the rack was built as stiff and strong as possible. Preliminary torque down tests were also conducted to determine the feasibility of mounting the composite honeycomb panels to the composite tubing sections via the additively manufactured tube inserts. Additional fastener torque down tests were also conducted with inserts (helicoils) imbedded within the joints. Lessons learned are also included and discussed.

Smith, Russ↗

Materials Science Research Rack-1 Fire Suppressant Distribution Test Report

Fire suppressant distribution testing was performed on the Materials Science Research Rack-1 (MSRR-1), a furnace facility payload that will be installed in the U.S. Lab module of the International Space Station. Unlike racks that were tested previously, the MSRR-1 uses the Active Rack Isolation System (ARIS) to reduce vibration on experiments, so the effects of ARIS on fire suppressant distribution were unknown. Two tests were performed to map the distribution of CO2 fire suppressant throughout a mockup of the MSRR-1 designed to have the same component volumes and flowpath restrictions as the flight rack. For the first test, the average maximum CO2 concentration for the rack was 60 percent, achieved within 45 s of discharge initiation, meeting the requirement to reach 50 percent throughout the rack within 1 min. For the second test, one of the experiment mockups was removed to provide a worst-case configuration, and the average maximum CO2 concentration for the rack was 58 percent. Comparing the results of this testing with results from previous testing leads to several general conclusions that can be used to evaluate future racks. The MSRR-1 will meet the requirements for fire suppressant distribution. Primary factors that affect the ability to meet the CO2 distribution requirements are the free air volume in the rack and the total area and distribution of openings in the rack shell. The length of the suppressant flowpath and degree of tortuousness has little correlation with CO2 concentration. The total area of holes in the rack shell could be significantly increased. The free air volume could be significantly increased. To ensure the highest maximum CO2 concentration, the PFE nozzle should be inserted to the stop on the nozzle.

Wieland, P. O.↗

The ISS Increments 3 and 4 Test Report: For the Active Rack Isolation System ISS Characterization Experiment (ARIS-ICE)

The purpose of ARIS-ICE is to improve, optimize then operationally test and document the performance of the ARIS system on the International Space Station. The ICE program required testing across a full 3 increments (2 through 4). This paper represents the operational report summarizing our accomplishments through the third and fourth increment of testing. The main objectives and results of the increment two testing are discussed in The Increment two Operational Report. This report can be obtained from the ISS Payloads Office or from (http://iss-www.isc.nasa.gov/sslissapt/payofc/OZ3/ARIS.html). In summary these were to ensure the smooth and successful activation of the system and correct operational issues related to long term testing. Then the follow on increment 3 & 4 testing encompassed the majority of the on orbit performance assessments and improvements made to the ARIS system. The intent here is to report these preliminary results of the increment 3 & 4 ARIS-ICE testing as well as the ARIS system improvements made for our users and customers.

Quraishi, Naveed↗

Evaluation of composite components on the Bell 206L and Sikorsky S-76 helicopters

Progress on two programs to evaluate structural composite components in flight service on Bell 206L and Sikorsky S-76 commercial helicopters is described. Forty ship sets of composite components that include the litter door, baggage door, forward fairing, and vertical fin have been installed on Bell Model 206L helicopters that are operating in widely different climates. Component installation started in 1981 and selected components were removed and tested at prescribed intervals over a ten year evaluation. Four horizontal stabilizers and eleven tail rotor spars that are production components on the S-76 helicopter were tested after prescribed periods of service to determine the effects of the operating environment on their performance. Concurrent with the flight evaluation, materials used to fabricate the components were exposed in ground racks and tested at specified intervals to determine the effects of outdoor environments. Results achieved from 123,000 hours of accumulated service on the Bell 206L components and 53,000 hours on the Sikorsky S-76 components are reported. Seventy-eight Bell 206L components were removed and tested statically. Results of seven years of ground exposure of materials used to fabricate the Bell 206L components are presented. Results of tests on four Sikorsky S-76 horizontal stabilizers and eleven tail rotor spars are also presented. Panels of material used to fabricate the Sikorsky S-76 components that were exposed for six years were tested and results are presented.

Baker, Donald J.↗

Evaluation of Composite Components on the Bell 206L and Sikorsky S-76 Helicopters

Progress on two programs to evaluate structural composite parts in flight service on Bell 206L and Sikorsky S-76 commercial helicopters is described. Forty ship sets of composite parts that include the litter door, baggage door, forward fairing, and vertical fin were installed on Bell Model 206L helicopters that are operating in widely different climates. Part installation started in 1981 and selected parts are being removed and tested at prescribed intervals over a 10 yr evaluation. Four horizontal stabilizers and eleven tail rotor spars that are production parts on the S-76 helicopter are being tested after prescribed periods of service to determine the effects of the operating environment on their performance. Concurrent with the flight evaluation, materials used to fabricate the parts are being exposed in ground racks and tested at specified intervals to determine the effects of outdoor environments. Results achieved from 123,000 hrs of accumulated service on the Bell 206L parts and 53,000 hrs on the Sikorsky S-76 parts are reported. Seventy-eight Bell 206L parts were removed and tested statically. Results of 7 yrs of ground exposure of materials used to make the Bell 206L parts are presented.

Baker, Donald J.↗

Flight service evaluation of composite components on Bell 206L and Sikorsky S-76 helicopters

Progress on two programs to evaluate composite structural components in flight service on commercial helicopters is described. Thirty-six ship sets of composite components that include the litter door, baggage door, forward fairing, and vertical fin were installed on Bell Model 206L helicopters that are operating in widely different climatic areas. Four horizontal stabilizers and ten tail rotor spars that are production components on the S-76 helicopter were tested after prescribed periods of service to determine the effects of the operating environment on their performance. Concurrent with the flight evaluation, specimens from materials used to fabricate the components were exposed in ground racks and tested at specified intervals to determine the effects of outdoor environments. Results achieved from 14,000 hours of accumulated service on the 206L components, tests on a S-76 horizontal stabilizer after 1600 hours of service, tests on a S-76 tail rotor spar after 2300 hours service, and two years of ground based exposure of material coupons are reported.

Baker, D. J.↗

Results and Interpretation of the WFRD ELS Distillation Down-Select Test Data

Testing of the Wiped-film Rotating-disk (WFRD) evaporator was conducted in support of the Exploration Life Support Distillation Down-Select Test. The WFRD was constructed at NASA Ames Research Center (ARC) and tested at NASA Marshall Space Flight Center (MSFC). The WFRD was delivered to MSFC in September 2009, and testing of solution #1 and solution #2 immediately following. Solution #1 was composed of humidity condensate and urine, including flush water and pretreatment chemicals. Solution #2 was composed of hygiene water, humidity condensate, and urine, including flush water and pretreatment chemicals. During the testing, the operational parameters of the WFRD were recorded and samples of the feed, brine, and product were collected and analyzed. The steady-state results of processing 414L of feed solution #1 and 1283L of feed solution #2 demonstrated that running the WFRD at a brine temperature of 50 C gave an average production rate of 16.7 L/hr. The specific energy consumption was 80.5W-hr/L. Data Analysis shows that the water recovery rates were 94% and 91%, respectively. The total mass of the WFRD as delivered to MSFC was 300 Kg. The volume of the tests stand rack was 1m width x 0.7m depth x 1.9m height or 1.5 cu m of which about half of the total volume is occupied by equipment. Chemical analysis of the distillate showed an average TOC of 20ppm, a pH of 3.5, and a conductivity of 98 mho/cm. The conductivity of the distillate, compared to the feed, decreased by 98.9%., the total ion concentration decreased by 99.6%, the total organics decreased 98.6%, and the metals were at or below detection limits

Delzeit, Lance Dean↗

Exploratory screening tests of several alloys and coatings for automobile thermal reactors

A total of 23 materials (including uncoated ferritic and austenitic iron-base alloys, uncoated nickel and cobalt-base superalloys, and several different coatings on AISI 304 stainless steel) were screened as test coupons on a rack in an automobile thermal reactor. Test exposures were generally 51 hours including 142 thermal cycles of 10 minutes at 1010 + or - 30 C test coupon temperature and 7-minutes cool-down to about 510 C. Materials that exhibited corrosion resistance better than that of Hastelloy X include: a ferritic iron alloy with 6 weight percent aluminum; three nickel-base superalloys; two diffused-aluminum coatings on AISI 304; and a Ni-Cr slurry-sprayed coating on AISI 304. Preliminary comparison is made on the performance of the directly impinged coupons and a reactor core of the same material.

Oldrieve, R. E.↗