Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization and Compensation of the Atmosphere for the Inversion of AVIRIS Calibrated Radiance to Apparent Surface Reflectance

Calibrated radiance spectra measured remotely record the integrated effects of the solar source, the atmosphere, and the surface. To pursue scientific research and applications, based on the molecular absorptions and constituent scattering properties of the surface, the solar source and atmosphere must be characterized and compensated in the spectra. This paper describes a set of radiative transfer spectral fitting algorithms that characterize the absorbing and scattering constituents of the atmosphere from calibrated AVIRIS spectra. These atmospheric characteristics were used in conjunction with the illumination and observation geometries to invert the AVIRIS calibrated radiance spectra to apparent surface reflectance. A validation of the algorithm was performed with in-situ reflectance spectra acquired at the time of the AVIRIS overflight over Pasadena, California, in 1994.

Green Robert O.↗

Characterization and Compensation of the Atmosphere for the Inversion of AVIRIS Calibrated Radiance to Apparent Surface Reflectance

Calibrated radiance spectra measured remotely, record the integrated effects of the solar source, the atmosphere, and the surface. To pursue scientific research and applications, based on the molecular absorptions and constituent scattering properties of the surface, the solar source and atmosphere must be characterized and compensated in the spectra. This paper describes a set of radiative transfer spectral fitting algorithms to characterize the absorbing and scattering constituents of the atmosphere from calibrated AVIRIS spectra.

atmosphere↗

CALIPSO IIR Version 2 Level 1b Calibrated Radiances: Analysis and Reduction of Residual Biases in the Northern Hemisphere

Version 2 of the Level 1b calibrated radiances of the Imaging Infrared Radiometer (IIR) on board the Cloud-Aerosol Lidar and Infrared Satellite Observation (CALIPSO) satellite has been released recently. This new version incorporates corrections of small but systematic seasonal calibration biases previously revealed in Version 1 data products mostly north of 30° N. These biases – of different amplitudes in the three IIR channels 8.65 µm (IIR1), 10.6 µm (IIR2), and 12.05 µm (IIR3) – were made apparent by a striping effect in images of IIR inter-channel brightness temperature differences (BTDs) and through seasonal warm biases of nighttime IIR brightness temperatures in the 30–60° N latitude range. The latter were highlighted through observed and simulated comparisons with similar channels of the Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Aqua spacecraft. To characterize the calibration biases affecting Version 1 data, a semi-empirical approach is developed, which is based on the in-depth analysis of the IIR internal calibration procedure in conjunction with observations such as statistical comparisons with similar MODIS/Aqua channels. Two types of calibration biases are revealed: an equalization bias affecting part of the individual IIR images and a global bias affecting the radiometric level of each image. These biases are observed only when the temperature of the instrument increases, and they are found to be functions of elapsed time since night-to-day transition, regardless of the season. Correction coefficients of Version 1 radiances could thus be defined and implemented in the Version 2 code. As a result, the striping effect seen in Version 1 is significantly attenuated in Version 2. Systematic discrepancies between nighttime and daytime IIR–MODIS BTDs in the 30–60° N latitude range in summer are reduced from 0.2 K in Version 1 to 0.1 K in Version 2 for IIR1–MODIS29. For IIR2–MODIS31 and IIR3–MODIS32, they are reduced from 0.4 K to close to zero, except for IIR3–MODIS32 in June, where the night-minus-day difference is around −0.1 K.

Garnier, Anne↗

Comparison of Spectral Radiance Calibration Techniques Used for Backscatter Ultraviolet Satellite Instruments

Methods for determining the absolute radiometric calibration sensitivities of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration errors. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV (SSBUV), Total Ozone Mapping Spectrometer (TOMS), Ozone Mapping Instrument (OMI), and Global Ozone Monitoring Experiment 2 (GOME-2) using standardized procedures traceable to national standards. These sphere-based sensitivities agree to within three percent [k equals 2] relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary radiance calibration method for BUV instruments. The uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Centers Radiometric Calibration and Development Laboratory is shown to be 4 percent at 250nm [k equals 2] when using a single traceable calibration standard. Significant reduction in the uncertainty of nearly 1 percent is demonstrated when multiple calibration standards are used.

residual errors↗

Spectral radiance calibrations between 165-300 nm - An interlaboratory comparison

The spectral radiance of deuterium lamps calibrated by the Max-Planck-Institut fuer Astronomie (MPI), by the U.S. National Bureau of Standards (NBS), and by the Physikalisch-Technische Bundesanstalt (PTB) are compared to check the agreement of UV radiometric scales. The NBS group used the optically thin continuum radiation from a wall-stabilized hydrogen arc as its fundamental radiometric standard, while the MPI and PTB groups used the synchrotron radiation facility in DESY. It is found that the spectral radiance scales based upon the DESY synchrotron and the NBS hydrogen arc are consistent, at least for one wavelength relative to another.

Bridges, J. M.↗

Radiance calibration of spherical integrators

Techniques for improving the knowledge of the radiance of large area spherical and hemispherical integrating energy sources have been investigated. Such sources are used to calibrate numerous aircraft and spacecraft remote sensing instruments. Comparisons are made between using a standard source based calibration method and a quantum efficient detector (QED) based calibration method. The uncertainty involved in transferring the calibrated values of the point source standard lamp to the extended source is estimated to be 5 to 10 percent. The use of the QED allows an improvement in the uncertainty to 1 to 2 percent for the measurement of absolute radiance from a spherical integrator source.

Mclean, James T.↗

Intercomparison of Laboratory Radiance Calibration Standards

Several standards for radiometric calibration were measured repeatedly with a spectroradiometer in order to understand how they compared in accuracy and stability. The tested radiance standards included a NIST 1000 W bulb and halon panel, two calibrated and stabilized integrating spheres, and a cavity blackbody. Results indicate good agreement between the blackbody and 1000 W bulb/spectralon panel, If these two radiance sources are assumed correct, then the integrating spheres did not conform. to their manufacturer-reported radiances in several regions of the spectrum. More detailed measurements am underway to investigate the discrepancy.

Pavri, Betina↗

Far ultraviolet spectral radiance calibrations at NBS.

The range of NBS radiometric calibration services has been extended into the far ultraviolet region of the spectrum where a dc high-power hydrogen wall-stabilized arc is used as a primary standard of spectral radiance. A capability in the range from 130 to 360 nm (overlapping conventional tungsten strip lamp radiometry) is presently available with estimated uncertainties between 5 and 10%, depending upon wavelength. The status of radiometric source standards in the far ultraviolet is briefly reviewed, and the hydrogen arc and NBS calibration facility are described in detail. The use of commercially available mercury Krefft-Rossler lamps and deuterium arc lamps as transfer or secondary standards is discussed, and the spectra of these lamps calibrated with the hydrogen arc standard are presented.

Ott, W. R.↗

Radiance calibration of the High Altitude Observatory white-light coronagraph on Skylab

The processing of over 35,000 photographs of the solar corona obtained by the white-light coronograph on Skylab is described. Calibration of the vast amount of data was complicated by temporal effects of radiation fog and latent image loss. These effects were compensated by imaging a calibration step wedge on each data frame. Absolute calibration of the wedge was accomplished through comparison with a set of previously calibrated glass opal filters. Analysis employed average characteristic curves derived from measurements of step wedges from many frames within a given camera half-load. The net absolute accuracy of a given radiance measurement is estimated to be 20%.

Poland, A. I.↗

SIMBIOS Normalized Water-Leaving Radiance Calibration and Validation: Sensor Response, Atmospheric Corrections, Stray Light and Sun Glint

This Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) contract supports acquisition of match up radiometric and bio-optical data for validation of Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) and other ocean color satellites, and evaluation of uncertainty budgets and protocols for in situ measurements of normalized water leaving radiances.

Mueller, James L.↗

Climate Quality Broadband and Narrowband Solar Reflected Radiance Calibration Between Sensors in Orbit

vAs the potential impacts of global climate change become more clear [1], the need to determine the accuracy of climate prediction over decade-to-century time scales has become an urgent and critical challenge. The most critical tests of climate model predictions will occur using observations of decadal changes in climate forcing, response, and feedback variables. Many of these key climate variables are observed by remotely sensing the global distribution of reflected solar spectral and broadband radiance. These "reflected solar" variables include aerosols, clouds, radiative fluxes, snow, ice, vegetation, ocean color, and land cover. Achieving sufficient satellite instrument accuracy, stability, and overlap to rigorously observe decadal change signals has proven very difficult in most cases and has not yet been achieved in others [2]. One of the earliest efforts to make climate quality observations was for Earth Radiation Budget: Nimbus 6/7 in the late 1970s, ERBE in the 1980s/90s, and CERES in 2000s are examples of the most complete global records. The recent CERES data products have carried out the most extensive intercomparisons because if the need to merge data from up to 11 instruments (CERES, MODIS, geostationary imagers) on 7 spacecraft (Terra, Aqua, and 5 geostationary) for any given month. In order to achieve climate calibration for cloud feedbacks, the radiative effect of clear-sky, all-sky, and cloud radiative effect must all be made with very high stability and accuracy. For shortwave solar reflected flux, even the 1% CERES broadband absolute accuracy (1-sigma confidence bound) is not sufficient to allow gaps in the radiation record for decadal climate change. Typical absolute accuracy for the best narrowband sensors like SeaWiFS, MISR, and MODIS range from 2 to 4% (1-sigma). IPCC greenhouse gas radiative forcing is approx. 0.6 W/sq m per decade or 0.6% of the global mean shortwave reflected flux, so that a 50% cloud feedback would change the global reflected flux by approx. 0.3 W/sq m or 0.3% per decade in broadband SW calibration change. Recent results comparing CERES reflected flux changes with MODIS, MISR, and SeaWiFS narrowband changes concluded that only SeaWiFS and CERES were approaching sufficient stability in calibration for decadal climate change [3]. Results using deep convective clouds in the optically thick limit as a stability target may prove very effective for improving past data sets like ISCCP. Results for intercalibration of geostationary imagers to CERES using an entire month of regional nearly coincident data demonstrates new approaches to constraining the calibration of current geostationary imagers. The new Decadal Survey Mission CLARREO is examining future approaches to a "NIST-in-Orbit" approach of very high absolute accuracy reference radiometers that cover the full solar and infrared spectrum at high spectral resolution but at low spatial resolution. Sampling studies have shown that a precessing CLARREO mission could calibrate other geo and leo reflected solar radiation and thermal infrared sensors.

Wielicki, Bruce A.↗

Radiative transfer based retrieval of reflectance from calibrated radiance imagery measured by an imaging spectrometer for lithological mapping of the Clark Mountains, California

Spectral radiance imagery measured by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are reduced to reflectance through compensation for atmospheric scattering, water vapor absorption, absorption of the well mixed gases, solar irradiance and the solar zenith angle. The LOWTRAN 7 (Kneizys et al., 1989) radiative transfer code form the basis for this retrieal. LOWTRAN 7 is constrained with water vapor determinations from the AVIRIS radiance data through an algorithm operating on the 940 nm atmospheric water band for every spatial element. In situ measurements of atmospheric optical depths are used to constrain the LOWTRAN 7 aerosol models. Accuracy of the retrieved reflectance spectra is evaluated with respect to surface spectra measured at the time of the overflight. The mineral bastnaesite is identified in the analysis of the retrieved reflectance imagery. These reflectance data provide a means to map the subtle mineral gradients in the PreCambrian block of the Clark Mountain range in southeastern California for geological analysis.

Green, Robert O.↗

TPSAS-NF1676L-10737-DND

The Clouds and the Earth's Radiant Energy System (CERES) project provides the community a quality climate TOA and surface fluxes and cloud properties and are key elements in evaluating the ability of climate models to predict both past and future climate states. One important aspect of successful climate monitoring is satellite calibration. The CERES instantaneous broadband calibration radiance stability is 0.1% per year, whereas the accuracy of the longwave (LW) and shortwave (SW) is better than 0.5% and 1% respectively. CERES uses the 3-hourly GEO fluxes and clouds to provide diurnally averaged daily and monthly TOA flux means from the CERES measurements onboard the Terra (10:30 AM local equator crossing time) and Aqua (13:30 PM) sun-synchronous satellites. The GEO radiances are calibrated against MODIS as a reference to provide consistent GEO retrieved cloud properties and derived broadband fluxes. These fluxes are then carefully normalized against the well-calibrated CERES fluxes to ensure climate quality fluxes, free of GEO artifacts. With the upcoming release of Edition3 products, CERES has just recalibrated all the CERES instruments to ensure that both Terra and Aqua fluxes are on the same radiometric scale and the removal of all known instrument trends. CERES will also recalibrate all GEO satellites using the entire GEO time record. CERES employs collocated, coincident ray-matched GEO/MODIS radiances as its primary technique, calibrating GEO radiances beginning in the year 2000. The advantage of the ray-matching technique is that it provides a full dynamic range of radiances to check the linearity of the GEO visible instrument. CERES uses deep convective clouds and invariant desert sites to validate the primary technique. All three methods can assess the stability of the GEO visible instrument. Examples of the CERES GEO calibration techniques and validation efforts will be shown at the conference. Special emphasis will be given to the newly incorporated desert site methodology.

R. Bhatt↗

Assessment of MODIS Thermal Emissive Band On-Orbit Calibration

Sixteen Moderate Resolution Imaging Spectroradiometer thermal emissive bands (TEBs) cover the wavelength from 3.75 to 14.24 m. TEB calibration uses data collected from the detector responses to the onboard blackbody (BB) and space view. The BB was designed to operate either at a constant temperature for detector linear gain calibration or at temperatures varying from ambient ( 270 K) to 315 K for on-orbit characterization of nonlinear coefficients. In this paper, we assess TEB on-orbit calibration performance in two aspects: One is to review the calibration trending on the orbital, daily, and multiyear timescales, and the other is to analyze the on-orbit calibration radiance uncertainty and its impact on the calibration. The calibration trending confirms the detector response dependence on the instrument temperature. The temperature trending and prelaunch characterization provide the basis for determining the calibration radiance source temperature range and uncertainties. An analytical approach was used to assess the impacts of onboard radiance uncertainties. The BB emission uncertainty, resulting from the temperature measurement error and emissivity uncertainty, causes a calibration uncertainty up to 0.3%, a value decreasing with the band wavelength. The BB nonblackness effect is analyzed and found to be insignificant. For the band with the lowest BB emissivity, the nonblackness affects the calibration radiance by less than 0.08%. The cavity emission uncertainty and the scan-mirror emission uncertainty both cause a less than 0.1% calibration uncertainty. The analysis of the nonlinear calibration coefficient uncertainty shows that its effect on the low Earth-view brightness-temperature range varies by band and is generally insignificant.

Chang, Tiejun↗

The Use of Transfer Radiometers in Validating the Visible through Shortwave Infrared Calibrations of Radiance Sources Used by Instruments in NASA's Earth Observing System

The detection and study of climate change over a time frame of decades requires successive generations of satellite, airborne, and ground-based instrumentation carefully calibrated against a common radiance scale. In NASA s Earth Observing System (EOS) program, the pre-launch radiometric calibration of these instruments in the wavelength region from 400 nm to 2500 nm is accomplished using internally illuminated integrating spheres and diffuse reflectance panels illuminated by irradiance standard lamps. Since 1995, the EOS Calibration Program operating within the EOS Project Science Office (PSO) has enlisted the expertise of national standards laboratories and government and university metrology laboratories in an effort to validate the radiance scales assigned to sphere and panel radiance sources by EOS instrument calibration facilities. This state-of-the-art program has been accomplished using ultra-stable transfer radiometers independently calibrated by the above participating institutions. In ten comparisons since February 1995, the agreement between the radiance measurements of the transfer radiometers is plus or minus 1.80% at 411 nm, plus or minus 1.31% at 552.5 nm, plus or minus 1.32% at 868.0 nm, plus or minus 2.54% at 1622nm, and plus or minus 2.81% at 2200nm (sigma =1).

Butler, James J.↗