Search NASASearch

SEARCH · Search NASA

Results for “radiation dose estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Distribution of plutonium and radium in the human heart

Since 1968, the United States Transuranium and Uranium Registries (USTUR) has studied the biokinetics and tissue dosimetry of uranium and transuranium elements in nuclear workers. As part of the USTUR collaboration with the Million Person Study of Low-Dose Health Effects, radiation dose to different parts of the human heart is being estimated for workers with documented intakes of 239 Pu or 226 Ra. The study may be expanded for workers with intakes of 238 U and other radionuclides. The distribution of radionuclides, expressed in terms of concentration (Bq per kg of tissue) serves as an important parameter for estimating radiation dose. Based on available organs from workers who donated their bodies or tissues for research, nine undissected hearts were selected: seven from USTUR registrants with plutonium exposure (males) and two individuals with radium intakes (female and male). For the plutonium workers, estimated 239 Pu systemic deposition ranged from <74 Bq to 1765 Bq. Estimated 226 Ra ‘initial systemic intakes’ were 10.1 MBq and 14.8 kBq for the female patient and male worker, respectively. Organ dissection was based on a heart model published by Borrego et al (2019 J. Radiol. Prot. 39 950–65). This model includes nine cardiac substructures: aorta, left main coronary artery, left atrium, left anterior descending artery, left circumflex artery, left ventricle, right atrium, right coronary artery, and right ventricle. In addition, heart valves, fat attached to epicardium, fluids, and a coronary bypass graft were collected resulting in 111 samples that are currently undergoing radiochemical analyses and mass-spectrometric measurements. The 239 Pu and 226 Ra evaluations are not completed. The results of this study are intended to support radiation worker health studies by improving associated dosimetric and epidemiological models.

USTUR

MTL_TX: A Multi-Task Transformer Model for Improved Radiation Time-Series Estimation

Controlling radiation doses at potential radioactive facilities is critical to ensuring the safety of both personnel and the public. At the Thomas Jefferson National Accelerator Facility (JLab), multiple sensors are deployed around the three experimental halls to monitor key parameters, including single-beam current, energy levels, current leakage, and radiation values during accelerator operations. In this study, we developed a Multi-task Transformer model, MTL_TX, to accurately estimate radiation doses at sensor locations based on historical data, with the aim of enhancing safety in accelerator facilities and surrounding public areas. To improve estimation accuracy, we integrated two innovative components into the proposed model: hierarchical feature embedding (HFE) and multi-level decomposition attention (MDA). Additionally, the multi-task learning (MTL) framework effectively leverages correlations among multiple sensors, enabling individual estimations for each sensor. MTL_TX achieved outstanding results on data collected in 2018, with an MSE of 0.1464, an RMSE of 0.2353, and an R 2 score of 0.8584. Furthermore, when trained on 2018 data, MTL_TX exhibited excellent generalization capability to unseen datasets from 2016 to 2019, achieving an MSE of 0.1407, an RMSE of 0.2263, and an R 2 score of 0.8831. These results demonstrate a significant improvement over existing state-of-the-art models.

Transformer

Application of FISH based G2-PCC assay for the cytogenetic assessment of high radiation dose exposures: Potential implications for rapid triage biodosimetry

The main goal of this study is to test the utility of calyculin A induced G2-PCC assay as a biodosimetry triage tool for assessing a wide range of low and acute high radiation dose exposures of photons. Towards this initiative, chromosome aberrations induced by low and high doses of x-rays were evaluated and characterized in G2-prematurely condensed chromosomes (G2-PCCs) by fluorescence in situ hybridization (FISH) using human centromere and telomere specific PNA (peptide nucleic acid) probes. A dose dependent increase in the frequency of dicentric chromosomes was observed in the G2-PCCs up to 20 Gy of x-rays. The combined yields of dicentrics and rings in the G2-PCCs showed a clear dose dependency up to 20 Gy from 0.02/cell for 0.1 Gy to 14.98/cell for 20 Gy. Centric rings were observed more frequently than acentric ring chromosomes in the G2-PCCs at all the radiation doses from 1 Gy to 20 Gy. A head-to-head comparison was also performed by FISH on the yields of chromosome aberrations induced by different doses of x-rays (0 Gy -7.5 Gy) in colcemid arrested metaphase chromosomes and calyculin A induced G2-PCCs. In general, the frequencies of dicentrics, rings and acentric fragments were slightly higher in G2-PCCs than in colcemid arrested metaphase chromosomes at all the radiation doses, but the differences were not statistically significant. To reduce the turnaround time for absorbed radiation dose estimation, attempt was made to obtain G2-PCCs by reducing the culture time to 36 hrs. The absorbed doses estimated in x-rays irradiated (0,1,2 and 4 Gy) G2-PCCs after 36 hrs of culture were grossly like that of G2-PCCs and colcemid arrested metaphase chromosomes prepared after 48 hrs of culture. Our study indicates that the shortened version of calyculin A induced G2-PCC assay coupled with the FISH staining technique can serve as an effective triage biodosimetry tool for large-scale radiological/nuclear incidents.

Science & Technology - Other Topics

Microreactor Incident-Free Transportation Radiation Dose Assessment

This report, prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Nuclear Regulatory Commission, provides an estimate of the radiation dose related to the transportation of microreactors following the regulatory limits established in Title 10 of the Code of Federal Regulations (10 CFR) 71.47(b). The transportation of irradiated microreactors poses unique challenges. Microreactors may be challenged to meet the current 10 mrem/hr limit at 2 meters from the vehicle in 10 CFR 71.47(b). The need to modify packaging to be within practical weight and size limits for shipping may limit the amount of shielding that can be applied for a microreactor transportation package design. Operational strategies that would necessitate moving a reactor within a short time after its operating life may result in higher radiation dose rates associated with lower cooling times. This study estimates the radiation dose to maximally exposed individuals (MEIs) under the current regulatory radiation level limit of 10 mrem/hr at 2 meters from the vehicle as well as alternative limits of 10, 50, 100, and 200 mrem/hr at 2 meters from the vehicle. This analysis expands on prior incident free transportation radiation dose assessments conducted for spent nuclear fuel (SNF) and radioactive waste transportation. The key factors analyzed include the microreactor fuel type and burnup, shipment cooling periods, shielding designs integrated into transport packaging, and exposure scenarios for MEIs for highway and rail transport. This report considers additional distances that may be associated with compensatory measures to ensure safe transport conditions under varying radiation dose limits, including enhanced routing measures, escort protocols, vehicle inspections, and operational restrictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.

AI

Deep Multitask Learning Models for Radiation Estimation at High Energy Accelerator Facility

Controlling the dose of radiation exposure in potential radioactive facilities is critical for ensuring the safety of staff and the public. Here, in this paper, we developed machine learning models to estimate radiation exposure efficiently at the Thomas Jefferson National Accelerator Facility (JLab), aiming to enhance safety in both accelerator facilities and public areas. Multiple sensors were deployed around the three experimental halls at JLab. Data on single-beam currents, energy levels, and radiation values at the sensor locations were collected during accelerator operation. We proposed a multi-task learning model for radiation estimation, utilizing either one-dimensional convolutional neural networks (1-D CNNs) or long short-term memory networks (LSTMs) as the backbone. The proposed model was trained to simultaneously estimate radiation levels at the sensor locations. Experimental results demonstrated that the proposed model with LSTM backbone achieved the best estimation performance, with an average R 2 score of 0.7557 for estimation within the same year and 0.7157 for estimation across different years. These results significantly surpassed those of competing models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Radiation damages the silicates present in polyphasic mineral aggregates causing concrete’s degradation

While many U.S. nuclear power plants have submitted Subsequent License Renewal Application to operate beyond 60 years, others are already considering Operations Beyond Eighty years. In such cases, concrete biological shields are exposed to neutron and gamma radiation exceeding prescribed thresholds. Radiation-induced volumetric expansion (RIVE), extensively studied in single crystals, may also contribute to the degradation of polycrystalline aggregates. Since minerals differ in atomic structure and chemistry, radiation can affect them in distinct ways. This study examines quartzite, marble, and limestone to evaluate how irradiation affects their physical attributes and chemical reactivity. Results show crystalline silicates experience significant RIVE damage and enhanced reactivity in alkaline solutions compared to non-irradiated phases. Enhanced intra- and inter-granular dissolution could compromise aggregate integrity. An empirical correlation links silicate dissolution rate to atomic constraints (density, rigidity) and radiation dose, providing a predictive framework for estimating changes in silicate aggregate properties within radiation-exposed concrete.

Bouissonnié, Arnaud [Univ. of California, Los Ange

SCALE Analyses of Scenarios in the Molten Salt Reactor Fuel Cycle

In support of the US Nuclear Regulatory Commission non-light-water reactor fuel cycle demonstration project, the capabilities of SCALE 6.3.1 for radionuclide characterization, criticality, and shielding were demonstrated through several scenarios in a molten salt reactor (MSR) nuclear fuel cycle. Three scenarios were selected for this study, with the molten salt breeder reactor (MSBR) serving as the reference design. The original thorium-based fuel salt used in MSBR was replaced with a 235 U-enriched fuel salt to better reflect anticipated future MSR concepts. The first scenario focused on the fuel salt preparation stage. Criticality analyses, using SCALE/CSAS-Shift and SCALE/SAMPLER, examined potential critical configurations in the fresh fuel salt container based on variables such as 235 U enrichment, UF 4 molar fraction, temperature, and container geometry. The second scenario explored the release of fission products during reactor operation in which the tritium buildup in the primary fuel salt was quantified through depletion calculations using SCALE/TRITON with continuous fuel makeup and fractional fission product removal. This scenario also assessed radioactivity levels in the off-gas system (OGS), quantifying radiotoxic nuclides that could be released into the environment. SCALE/SAMPLER was employed to perform uncertainty quantification to identify key operating parameters influencing the buildup of radiotoxic nuclides in the OGS. Additionally, radiation dose rates were calculated using SCALE/MAVRIC to estimate the maximum exposure levels within the reactor cell complex during operation. The final scenario evaluated the decay heat and radioactivity of the primary fuel salt collected in the drain tank, as well as the radiation dose rate outside the building from the presence of the drain tank. Overall, the application of SCALE’s various capabilities for radionuclide inventory generation, criticality analysis, and shielding in MSR fuel cycles was successfully demonstrated across these scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Reconstructing Hanford worker external doses from photons for epidemiology

The accurate reconstruction of external photon doses is essential for credible radiation epidemiology. This article presents the methodology used to derive dose estimates for 37 012 Hanford Site workers included in the Million Person Study. The approach employs historical dose records from the Hanford Radiation Exposure database and a previous epidemiology study. Bias correction factors specific to dosimeter type and period of use were applied and missing annual doses were estimated using a hierarchical nearby method to estimate deep dose equivalent for each worker. For early years with limited detection sensitivity, missed doses were quantified based on expected time-period-specific, low-dose statistical distributions. The revised dose estimates resulted in lower median and mean career doses than unadjusted data, while increasing the number of person-years with nonzero dose. Sensitivity analyses assessed the influence of bias in dosimetry measurements, missed doses and gap years on dose estimates. Differences in cumulative dose estimates between unadjusted and revised annual estimates are most prominent in the early operational years due to the highest bias during that time period.

dose reconstruction

Probing soft X-ray induced photoreduction of a model Mn-complex at cryogenic conditions

Soft X-ray absorption spectroscopy of first row transition elements at their respective L -edges provides important information about the oxidation and spin states of the metal centers. However, the associated sample damage in radiation-sensitive samples substantially alters the electronic and chemical structures of redox-active metal centers. Here, we measure the soft X-ray spectrum of the model Mn III (acac) 3 complex containing a redox-active Mn III metal center in an octahedral environment with a superconducting transition-edge sensor detector. To reduce the secondary damage resulting primarily from the diffusion of radicals and electrons, the spectra are collected at 30 K and 80 K on solid samples. Starting from the first scan, we detect the contribution of X-ray induced sample damage leading to a change in the Mn II intensity. However, at low temperatures, particularly at 30 K, we do not observe a gradual increase in the radiation damage with successive scans with the X-ray beam at the same spot. At our estimated dose of 90 kGy, we find 62% of Mn III (acac) 3 is still intact at 30 K. However, at room temperature, we see a gradual increase in radiation damage with increasing numbers of scans at the same spot, which is consistent with the possibility of increased diffusion rates of secondary radicals and electrons as noted in other studies.

L-edge spectroscopy

Argonne National Laboratory Site Environmental Report for Calendar Year 2023

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2023. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY

X-ray Security Imaging on Personal Dosimetry

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY

Estimation of General Area Dose Rates During Closure Weld Operations on the DOE Standard Canister Pacific Basin Nuclear Conference 2024

The Department of Energy (DOE) Spent Nuclear Fuel (SNF) Road Ready Demonstration Project is an effort to package DOE-managed SNF for road-ready dry storage. A key operation in this demonstration is performing the closure weld on the DOE Standard Canister after it has been loaded with the SNF. Planning the closure weld operations is ongoing and must consider what parts of the operations (if any) can be done manually and what parts must be done remotely. A key parameter to inform the evolving planning of these operations is the dose rate in the vicinity of the canister and the dose hazard posed to the closure weld operators and collocated workers. This study developed a Monte Carlo N-Particle (MCNP) model of the closure weld operation, which was used to estimate general area dose rates as well as dose rates to the welding location, weld operators, and collocated workers. These estimates provide some insight into the potential radiation exposure hazard for workers during the operations and are a factor to be considered in the ongoing development of designs, technology, processes, and administrative controls for packaging DOE-managed SNF for road-ready dry storage.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Radiation Dose Modeling for Niowave’s Accelerator Driven Uranium Target Assembly 3

Molybdenum-99 is a high-value radionuclide commonly used for medical purposes within the United States. The National Nuclear Security Administration (NNSA) seeks to reliably produce the radioisotope 99 Mo without the use of highly enriched uranium. NNSA’s Office of Material Management and Minimization (M3) provides funding and government laboratory expertise to private companies to expedite the production process domestically and currently funds designs that use low-enriched uranium or other 99 Mo production pathways. Several production designs are being explored across the industry, including uranium fission and photonuclear conversion of 100 Mo targets. Niowave Inc. seeks to produce 99 Mo via a high-energy electron accelerator that strikes a lead-bismuth eutectic target that ultimately produces a consistent neutron flux. The neutron flux then interacts in a subcritical reactor core configuration to produce fission in low-enriched or natural uranium targets. These fissionable targets are then processed to extract 99 Mo. The purpose of this work is to estimate the neutron and photon dose response across Niowave’s proposed facility for worker safety during operation. Owing to the size of the proposed Niowave facility and necessary shielding, unbiased Monte Carlo radiation transport is impractical, and variance reduction methods are required. This work focuses on the weight window variance reduction method to produce high confidence dose response results within a Monte Carlo radiation transport code. Specifically, an adjoint-informed weight window methodology was created to improve the dose response estimates for accelerator-driven subcritical reactor designs. This adjoint-informed methodology was implemented for Niowave’s proposed design and improved dose results at far-field locations across the facility. Acceptable dose rate contours for the proposed facility were generated across the facility and are presented in this work.

07 ISOTOPE AND RADIATION SOURCES

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks