Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a Detector Model for Generation of Synthetic Radiographs of Cargo Containers

Creation of synthetic cargo-container radiographs that possess attributes of their empirical counterparts requires accurate models of the imaging system response. Synthetic radiographs serve as surrogate data in studies aimed at determining system effectiveness for detecting target objects when it is impractical to collect a large set of empirical radiographs. In the case where a detailed understanding of the detector system is available, an accurate detector model can be derived from first principles. In the absence of this detail, it is necessary to derive empirical models of the imaging-system response from radiographs of well-characterized objects. Such a case is the topic of this work, where we demonstrate the development of an empirical model of a gamma-ray radiography system with the intent of creating a detector-response model that translates uncollided photon transport calculations into realistic synthetic radiographs. The detector-response model is calibrated to field measurements of well-characterized objects thus incorporating properties such as system sensitivity, spatial resolution, contrast, and noise.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Reconstruction of 2D x-ray radiographs at the National Ignition Facility using pinhole tomography (invited)

Two-dimensional radiographs of imploding fusion capsules are obtained at the National Ignition Facility by projection through a pinhole array onto a time-gated framing camera. Parallax among images in the image array makes it possible to distinguish contributions from the capsule and from the backlighter, permitting correction of backlighter non-uniformities within the capsule radiograph. Furthermore, precise determination of the imaging system geometry and implosion velocity enables combination of multiple images to reduce signal-to-noise and discover new capsule features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Morphometric Comparison of Clavicle Outlines from 3D Bone Scans and 2D Chest Radiographs: A Short-listing Tool to Assist Radiographic Identification of Human Skeletons

This paper describes a computerized clavicle identification system, primarily designed to resolve the identities of unaccounted for US soldiers who fought in the Korean War. Elliptical Fourier analysis is used to quantify the clavicle outline shape from skeletons and postero-anterior antemortem chest radiographs to rank individuals in terms of metric distance. Similar to leading fingerprint identification systems, shortlists of the top matching candidates are extracted for subsequent human visual assessment. Two independent tests of the computerized system using 17 field-recovered skeletons and 409 chest radiographs demonstrate that true positive matches are captured within the top 5% of the sample 75% of the time. These results are outstanding given the eroded state of some field-recovered skeletons and the faintness of the 1950’s photoflurographs. These methods enhance the capability to resolve several hundred cold cases for which little circumstantial information exists and current DNA and dental record technologies cannot be applied.

computer assisted↗

Reporting of Trauma-related Radiographic Images in After-hours Trauma Units: Experiences of Radiographers and Medical Practitioners in the Eastern Cape, Republic of South Africa

Radiographer reporting, as a response to the universal shortage of radiologists, is an established practice in several countries across the globe. Effective patient management and improved service delivery have resulted since the implementation of radiographer reporting; however, this practice has not yet materialised in the Republic of South Africa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A single-pixel X-ray imager concept and its application to secure radiographic inspections

Imaging technology is generally considered too invasive for arms control inspections due to the concern that it cannot properly secure sensitive features of the inspected item. However, this same sensitive information, which could include direct information on the form and function of the items under inspection, could be used for robust arms control inspections. The single-pixel X-ray imager (SPXI) is introduced as a method to make such inspections, capturing the salient spatial information of an object in a secure manner while never forming an actual image. The method is built on the theory of compressive sensing and the single pixel optical camera. The performance of the system is quantified here using simulated inspections of simple objects. Measures of the robustness and security of the method are introduced and used to determine how such an inspection would be made which can maintain high robustness and security. In particular, it is found that an inspection with low noise (<1%) and high undersampling (>256×) exhibits high robustness and security.

Arms Control↗

In Situ Real-Time Radiographic Study of Thin Film Formation Inside Rotating Hollow Spheres

Hollow spheres with uniform coatings on the inner surface have applications in optical devices, time- or site controlled drug release, heat storage devices, and target fabrication for inertial confinement fusion experiments. The fabrication of uniform coatings, which is often critical for the application performance, requires precise understanding and control over the coating process and its parameters. Here, we report on in-situ real-time radiography experiments that provide critical spatio-temporal information about the distribution of fluids inside hollow spheres during uniaxial rotation. Image analysis and computer fluid dynamics simulations were used to explore the effect of liquid viscosity and rotational velocity on the film uniformity. The data were then used to demonstrate the fabrication of uniform sol-gel chemistry derived porous polymer films inside 2mm inner diameter diamond shells.

aerogel↗

Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40–200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A survey of radiographers' confidence and self-perceived accuracy in frontline image interpretation and their continuing educational preferences

The provision of a written comment on traumatic abnormalities of the musculoskeletal system detected by radiographers can assist referrers and may improve patient management, but the practice has not been widely adopted outside the United Kingdom. The purpose of this study was to investigate Australian radiographers' perceptions of their readiness for practice in a radiographer commenting system and their educational preferences in relation to two different delivery formats of image interpretation education, intensive and non-intensive. A cross-sectional web-based questionnaire was implemented between August and September 2012. Participants included radiographers with experience working in emergency settings at four Australian metropolitan hospitals. Conventional descriptive statistics, frequency histograms, and thematic analysis were undertaken. A Wilcoxon signed-rank test examined whether a difference in preference ratings between intensive and non-intensive education delivery was evident. The questionnaire was completed by 73 radiographers (68% response rate). Radiographers reported higher confidence and self-perceived accuracy to detect traumatic abnormalities than to describe traumatic abnormalities of the musculoskeletal system. Radiographers frequently reported high desirability ratings for both the intensive and the non-intensive education delivery, no difference in desirability ratings for these two formats was evident (z = 1.66, P = 0.11). Some Australian radiographers perceive they are not ready to practise in a frontline radiographer commenting system. Overall, radiographers indicated mixed preferences for image interpretation education delivered via intensive and non-intensive formats. Further research, preferably randomised trials, investigating the effectiveness of intensive and non-intensive education formats of image interpretation education for radiographers is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of radiographers’ mammography screen-reading accuracy in Australia

This study aimed to evaluate the accuracy of radiographers’ screen-reading mammograms. Currently, radiologist workforce shortages may be compromising the BreastScreen Australia screening program goal to detect early breast cancer. The solution to a similar problem in the United Kingdom has successfully encouraged radiographers to take on the role as one of two screen-readers. Prior to consideration of this strategy in Australia, educational and experiential differences between radiographers in the United Kingdom and Australia emphasise the need for an investigation of Australian radiographers’ screen-reading accuracy. Ten radiographers employed by the Westmead Breast Cancer Institute with a range of radiographic (median = 28 years), mammographic (median = 13 years) and BreastScreen (median = 8 years) experience were recruited to blindly and independently screen-read an image test set of 500 mammograms, without formal training. The radiographers indicated the presence of an abnormality using BI-RADS®. Accuracy was determined by comparison with the gold standard of known outcomes of pathology results, interval matching and client 6-year follow-up. Individual sensitivity and specificity levels ranged between 76.0% and 92.0%, and 74.8% and 96.2% respectively. Pooled screen-reader accuracy across the radiographers estimated sensitivity as 82.2% and specificity as 89.5%. Areas under the reading operating characteristic curve ranged between 0.842 and 0.923. This sample of radiographers in an Australian setting have adequate accuracy levels when screen-reading mammograms. It is expected that with formal screen-reading training, accuracy levels will improve, and with support, radiographers have the potential to be one of the two screen-readers in the BreastScreen Australia program, contributing to timeliness and improved program outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving radiograph analysis throughput through transfer learning and object detection

SIGN Fracture Care International partners with surgeons in low-resource hospitals worldwide to provide access to effective orthopedic care by donating educational materials and innovatively designed surgical implants. Over two decades, SIGN’s Online Surgical Database (SOSD) has grown to contain over 500,000 medical images, with radiographs holding the majority share. One challenge in working with hospitals worldwide is that both the radiographs uploaded to the SOSD and the data entry accompanying the uploads vary in quality. To improve the accuracy of data in the SOSD, we trained a model to detect surgical implants in radiographs. We first developed a tool to automatically detect radiographs, then trained an object detection model to determine the number and placement of surgical implants visible in the radiograph. Active learning was used to generate a training set containing 2,510 radiographs with screws, nails, and plates labeled by bounding boxes. Training a model to simultaneously recognize all three classes of implants gave a low average precision (AP) for the plate class, likely due to the low number of plate instances in our training set and the large variety of surgical plates used by SIGN-partnered surgeons. Applying standard image augmentation techniques to increase the plate count in our training set did not appreciably increase the AP of plate detection. To improve plate detection, we redrew the bounding boxes to account for correlations between the screw and plate classes. Training one model to detect nails and screws and a separate model to detect plates increased the AP of plate detection by 78.8 percentage points. The AP of each class was 80.7% for screws, 93.6% for nails, and 92.6% for plates; meanwhile, the sensitivity was 92% for screws, 86% for nails, and 81% for plates. We show that object detection methods can be used to detect surgical implants in radiographs of varying quality; however, the detection ability is dependent on the type of implant, and some implants, in our case plates, must be treated differently than others. Such tools can improve the throughput of radiograph analysis, assisting physicians and surgeons with the treatment of bone fractures.

60 APPLIED LIFE SCIENCES↗

A review of computer aided interpretation technology for the evaluation of radiographs of aluminum welds

Industrial radiography is a well established, reliable means of providing nondestructive structural integrity information. The majority of industrial radiographs are interpreted by trained human eyes using transmitted light and various visual aids. Hundreds of miles of radiographic information are evaluated, documented and archived annually. In many instances, there are serious considerations in terms of interpreter fatigue, subjectivity and limited archival space. Quite often it is difficult to quickly retrieve radiographic information for further analysis or investigation. Methods of improving the quality and efficiency of the radiographic process are being explored, developed and incorporated whenever feasible. High resolution cameras, digital image processing, and mass digital data storage offer interesting possibilities for improving the industrial radiographic process. A review is presented of computer aided radiographic interpretation technology in terms of how it could be used to enhance the radiographic interpretation process in evaluating radiographs of aluminum welds.

Lloyd, J. F., Sr.↗

Monte Carlo N-Particle Transport Performance of Predicting Digital Radiographic IQI Inspection

The identification of porosity, geometric noncompliance, and other defect types are critical to the qualification of materials and components. X-ray radiographic nondestructive testing is a common industrial inspection method for process quality control and component qualification and certification. Digital radiography provides a quick and efficient alternative when compared to traditional film-based inspection. The quality of radiographic inspection is dependent on equipment specifications, such as the source spot size and detector pixel size, and the specific parameters selected for use for the radiographic technique. To evaluate if an x-ray system and technique is sufficient for a given requirement, a radiographic image quality indicator (IQI) can be used. Radiographic IQIs in hard to machine materials or hard to manufacture defects can be time consuming and expensive to manufacture. This study was conducted to evaluate current Savannah River National Laboratory (SRNL) x-ray imaging systems with a custom tantalum IQI and using Monte Carlo simulations to predict the performance of future systems. The tantalum IQI was tested using a Siefert Isovolt 420 keV x-ray tube with a Perkin Elmer XRD 1611 flat panel with 100-micron pixels. Using the Monte Carlo N-Particle transport software, the radiographic tally was used to simulate the photon flux through an identical tantalum IQI. These simulations provided a benchmark as to the best theoretical identification on a given system using our tantalum IQI. The simulations were refined to match SRNL’s current systems’ noise levels, leading to confidence in their ability to predict the performance of other systems that may be purchased and deployed in the future at the Savannah River Site. Future studies will be conducted to prove this research can be extended to artificially evaluate the ability for systems to identify critical defect sizes through x-ray radiographic inspection, drastically reducing the cost and time burdens of producing high-fidelity radiographic test articles.

digital X-ray radiography↗

Improvements in solid state radiographic converter screens.

Description of two different kinds of solid-state radiographic converter screens which have been developed. After briefly reviewing the working principles of the solid-state image converter - a sandwich type structure consisting of a photoconductive layer and an electroluminescent layer with a semiconductive layer and a black layer between them, two different kinds of radiographic converter screens are described - a radiographic amplifier screen that can be used as a substitute for the fluoroscopic screen, and a radiographic storage screen that can be used instead of radiographic films. The construction of both kinds of converters is fundamentally the same, the only difference being in the sensing photoconductive material. The radiographic amplifier screen has a moderately fast response, while the radiographic storage screen displays the image long after the irradiation is stopped.

Szepesi, Z.↗