Search NASA⌕ Search

SEARCH · Search NASA

Results for “radioisotope identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radioisotope Identification with List-Mode Gamma Ray Data: A rigorous assessment on the value of temporal information applied to radioisotope identification.

This work explores the potential of utilizing temporal data from gamma-ray detectors, known as list-mode data, to enhance radioisotope identification. Traditional identification methods, which rely on full gamma-ray spectrum analysis, often require long dwell times and struggle with “confuser” sources, or spectra with similarly spaced spectral peaks. We hypothesize that by leveraging the probabilistic nature of nuclear decay and the time-encoded information from decay sequences and interactions with surrounding materials, we can improve classification accuracy over static spectral analysis. This research rigorously examines the temporal content of list-mode data through exploratory data analysis via correlation discovery and information theory. We further propose a basic classification model that can utilize spectral or temporal data (or both) to determine if the incorporation of temporal information can improve radioisotope identification. The findings suggest that the temporal information present in list-mode gamma-ray data has merit and should be further investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Fireworks Algorithm in Gamma-Ray Spectrum Fitting for Radioisotope Identification

We present that identification of radioisotopic signature patterns in gamma-ray spectra is of paramount importance in various applications of gamma spectroscopy. Therefore, there are several active research efforts to develop accurate and precise methods to perform automated spectroscopic analysis and subsequently recognize gamma-ray signatures. In this work, the authors present a new method for radioisotope identification in gamma-ray spectra obtained with a low resolution radiation detector. The method fits the obtained spectrum with a linear combina-tion of known template signature patterns. Coefficients of the linear combination are evaluated by computing the solution of a single objective optimization problem, whose objective is the Theil-1 inequality coefficient. Optimization of the problem is performed by the Fireworks Algorithm, which identifies a set of coefficients that minimize the Theil-1 value. The computed coefficients are statistically tested for being significantly different than zero or not, and if at least one is found to be zero then the Fireworks Algorithm is used to reiterate fitting using the non-zero templates. Fitting iterations are continued up to the point that no linear coefficients are found to be zero. The output of the method is a list that contains the radioisotopes that have been identified in the measured spectrum. The method is tested on a set of both simulated and real experimental gamma-ray spectra comprised of a variety of isotopes, and compared to a multiple linear regression fitting, and genetic algorithm Theil-1 based fitting. Finally, results demonstrate the potentiality of the Fireworks Algorithm based method, expressed as higher accuracy and similar precision over the other two tested methodologies for radioisotope signature pattern identification in the framework of gamma-ray spectrum fitting.

Theil Coefficient↗

Absolute Efficiency Characterization of Neutron Detectors within Radioisotope Identification Devices [Slides]

Some Radioisotope Identification Devices (RIIDs) have a low efficiency neutron detector that can provide a neutron singles counting rate along with the primary gamma spectra that can be used to identify a radioisotope. When we know absolute efficiency, other characteristics of a radioisotope can be estimated such as mass or source strength when accompanied by the identity of the isotope and other observable variables. This study focuses on characterizing and comparing the absolute neutron efficiencies of some commonly used RIIDs: the ORTEC Detective X, ORTEC RADEAGLET-R, and FLIR IDentifinder 2.

Nuclear Criticality Safety Program (NCSP)↗

Sim-to-real supervised domain adaptation for radioisotope identification

Machine learning has the potential to improve the speed and reliability of radioisotope identification using gamma spectroscopy. However, meticulously labeling an experimental dataset for training is often prohibitively expensive, while training models purely on synthetic data is risky due to the domain gap between simulated and experimental measurements. In this research, we demonstrate that supervised domain adaptation can substantially improve the performance of radioisotope identification models by transferring knowledge between synthetic and experimental data domains. We consider two domain adaptation scenarios: (1) a simulation-to-simulation adaptation, where we perform multi-label proportion estimation using simulated high-purity germanium detectors, and (2) a simulation-to-experimental adaptation, where we perform multi-class, single-label classification using measured spectra from handheld lanthanum bromide (LaBr) and sodium iodide (NaI) detectors. We begin by pretraining a spectral classifier on synthetic data using a custom transformer-based neural network. After subsequent fine-tuning on just 64 labeled experimental spectra, we achieve a test accuracy of 96% in the sim-to-real scenario with a LaBr detector, far surpassing a synthetic-only baseline model (75%) and a model trained from scratch (80%) on the same 64 spectra. Furthermore, we demonstrate that domain-adapted models learn more human-interpretable features than experiment-only baseline models. Overall, our results highlight the potential for supervised domain adaptation techniques to bridge the sim-to-real gap in radioisotope identification, enabling the development of accurate and explainable classifiers even in real-world scenarios where access to experimental data is limited.

Lalor, Peter W.↗

Radioisotope Identification with List-Mode Gamma-Ray Data

This work explores the potential of utilizing temporal data from gamma-ray detectors, known as list-mode data, to enhance radioisotope identification. Traditional identification methods, which rely on full gamma-ray spectrum analysis, often require long dwell times and struggle with spectra containing similarly spaced spectral peaks. We hypothesize that by leveraging the probabilistic nature of nuclear decay and the time-encoded information from decay sequences and interactions with surrounding materials, we can improve classification accuracy over static spectral analysis. This research examines the temporal content of list-mode data through exploratory data analysis via correlation discovery and qualitative distribution analysis. Additionally, we propose a probabilistic classification model that can utilize spectral data, temporal data, or both to determine if the incorporation of temporal information improves radioisotope identification. Our findings suggest that the temporal information present in list-mode gamma-ray data has merit and should be further investigated to develop more robust and optimal methods for utilizing this temporal information in applications requiring radioisotope identification.

List-mode data↗

Strontium Iodide Instrument Development for Gamma Spectroscopy and Radioisotope Identification

Development of the Europium-doped Strontium Iodide scintillator, SrI2(Eu), has progressed significantly in recent years. SrI2(Eu) has excellent material properties for gamma ray spectroscopy: high light yield (>80,000 ph/MeV), excellent light yield proportionality, and high effective atomic number (Z=49) for high photoelectric cross-section. High quality 1.5 and 2 diameter boules are now available due to rapid advances in SrI2(Eu) crystal growth. In these large SrI2(Eu) crystals, optical self-absorption by Eu2+ degrades the energy resolution as measured by analog electronics, but we mitigate this effect through on-the-fly correction of the scintillation pulses by digital readout electronics. Using this digital correction technique we have demonstrated energy resolution of 2.9% FWHM at 662 keV for a 4 in3 SrI2(Eu) crystal, over 2.6 inches long. Based on this digital readout technology, we have developed a detector prototype with greatly improved radioisotope identification capability compared to Sodium Iodide, NaI(Tl). The higher resolution of SrI2(Eu) yields a factor of 2 to 5 improvement in radioisotope identification (RIID) error rate compared to NaI(Tl).

energy resolution↗

Unsupervised domain adaptation for radioisotope identification in gamma spectroscopy

Training machine learning models for radioisotope identification using gamma spectroscopy remains an elusive challenge for many practical applications, largely stemming from the difficulty of acquiring and labeling large, diverse experimental datasets. Simulations can mitigate this challenge, but the accuracy of models trained on simulated data can deteriorate substantially when deployed to an out-of-distribution operational environment. In this study, we demonstrate that unsupervised domain adaptation (UDA) can improve the ability of a model trained on synthetic data to generalize to a new testing domain, provided unlabeled data from the target domain are available. Conventional supervised techniques are unable to utilize this data because the absence of isotope labels precludes defining a supervised classification loss. Instead, we first pretrain a spectral classifier using labeled synthetic data and subsequently leverage unlabeled target data to align the learned feature representations between the source and target domains. We compare a range of different UDA techniques, finding that minimizing the maximum mean discrepancy (MMD) between source and target feature vectors yields the most consistent improvement to testing scores. For instance, using a custom transformer-based neural network, we achieved a testing accuracy of $0.904 \pm 0.022$ on an experimental LaBr test set after performing unsupervised feature alignment via MMD minimization, compared to $0.754 \pm 0.014$ before alignment. Overall, our results highlight the potential of using UDA to adapt a radioisotope classifier trained on synthetic data for real-world deployment.

Lalor, Peter W.↗

Radioisotope identification method for poorly resolved gamma-ray spectrum of nuclear security concern

Gamma-ray signal can be used as a fingerprint for radioisotope identification. In the context of radioactive and nuclear materials security at the border control point, the detection task can present a significant challenge due to various constraints such as the limited measurement time, the shielding conditions, and the noise interference. This study proposes a novel method to identify the signal of one or several radioisotopes from a poorly resolved gamma-ray spectrum. In this method, the noise component in the raw spectrum is reduced by the wavelet decomposition approach, and the removal of the continuum background is performed using the baseline determination algorithm. Finally, the identification of radioisotope is completed using the matrix linear regression method. The proposed method has been verified by experiments using the poorly resolved gamma-ray signals from various scenarios including single source, mixing of natural uranium with five of the most common industrial radioactive sources (57Co, 60Co, 133Ba, 137Cs, and 241Am). The preliminary results show that the proposed algorithm is comparable with the commercial method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RADIOISOTOPE IDENTIFICATION OF SHIELDED AND MASKED SNM RDD MATERIALS

Sonar and speech techniques have been investigated to improve functionality and enable handheld and other man-portable, mobile, and portal systems to positively detect and identify illicit nuclear materials, with minimal data and with minimal false positives and false negatives. RadSonar isotope detection and identification is an algorithm development project funded by NA-22 and employing the resources of Savannah River National Laboratory and three University Laboratories (JHU-APL, UT-ARL, and UW-APL). Algorithms have been developed that improve the probability of detection and decrease the number of false positives and negatives. Two algorithms have been developed and tested. The first algorithm uses support vector machine (SVM) classifiers to determine the most prevalent nuclide(s) in a spectrum. It then uses a constrained weighted least squares fit to estimate and remove the contribution of these nuclide(s) to the spectrum, iterating classification and fitting until there is nothing of significance left. If any Special Nuclear Materials (SNMs) were detected in this process, a second tier of more stringent classifiers are used to make the final SNM alert decision. The second algorithm is looking at identifying existing feature sets that would be relevant in the radioisotope identification context. The underlying philosophy here is to identify parallels between the physics and/or the structures present in the data for the two applications (speech analysis and gamma spectroscopy). The expectation is that similar approaches may work in both cases. The mel-frequency cepstral representation of spectra is widely used in speech, particularly for two reasons: approximation of the response of the human ear, and simplicity of channel effect separation (in this context, a 'channel' is a method of signal transport that affects the signal, examples being vocal tract shape, room echoes, and microphone response). Measured and simulated gamma-ray spectra from a hand-held Radioisotope Identification Device were used to evaluate the algorithms. This paper will present and discuss results of the Test and Evaluation performed on two algorithms produced from the project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

Gamma Spectroscopy Detector Candidates and Radioisotope Identification Algorithms for Use in National Security Applications

In 2006, the United States Congress mandated for the Department of Homeland Security (DHS) to screen all cargo containers to protect against terrorist acts and ensure the safety and security of the nation. Containers are screened by gamma and neutron detectors to ensure threat material is not smuggled into the country. However, because commerce is radioactive, detecting the presence of radioactive materials is not sufficient in ensuring the safety and security of the nation. Radioactive materials must also be identified in real time, thus distinguishing threat sources (Uranium-235 and Plutonium-230) from non-threat sources (kitty litter, pot ash, medical isotopes). Screening cargo containers can be considered a two-step process (1) alerting to the presence of radioactive material when gamma counts exceed a threshold setting, and (2) once alerted, identifying the type of radioactive material, which is done by collecting a gamma spectra and analyzing it with an analysis tool/algorithm. For this reason, it is important to evaluate not only emerging technology in neutron and gamma detection, but also investigate new advances in algorithm development for radioisotope identification (RIID). New candidates in detection and on-board algorithm analysis might offer opportunities to make the scanning, detection, and identification process more efficient while still ensuring the health and safety of the public. This research will investigate emerging technology in radiation detection focused on gamma spectroscopy capabilities and RIID algorithms for DHS applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Questionnaire for Radioisotope Identification and Estimation from Gamma Spectra using PyRIID v2

Accurate targeting of radioisotope classifiers and estimators requires an understanding of the target problem space. In order to facilitate clear communication on expected model behavior and performance between practitioners and stakeholders on their problems, this questionnaire was created. Stakeholder responses form the basis of a trained model as well as the start of usage requirements for the model as it is integrated with analysis processes or detection systems. This questionnaire may also be useful to machine learning practitioners and gamma spectroscopists developing new algorithms as a starting point for characterizing their problem space, especially if they are using PyRIID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A NEW ALGORITHM FOR RADIOISOTOPE IDENTIFICATION OF SHIELDED AND MASKED SNM/RDD MATERIALS

Detection and identification of shielded and masked nuclear materials is crucial to national security, but vast borders and high volumes of traffic impose stringent requirements for practical detection systems. Such tools must be be mobile, and hence low power, provide a low false alarm rate, and be sufficiently robust to be operable by non-technical personnel. Currently fielded systems have not achieved all of these requirements simultaneously. Transport modeling such as that done in GADRAS is able to predict observed spectra to a high degree of fidelity; our research is focusing on a radionuclide identification algorithm that inverts this modeling within the constraints imposed by a handheld device. Key components of this work include incorporation of uncertainty as a function of both the background radiation estimate and the hypothesized sources, dimensionality reduction, and nonnegative matrix factorization. We have partially evaluated performance of our algorithm on a third-party data collection made with two different sodium iodide detection devices. Initial results indicate, with caveats, that our algorithm performs as good as or better than the on-board identification algorithms. The system developed was based on a probabilistic approach with an improved approach to variance modeling relative to past work. This system was chosen based on technical innovation and system performance over algorithms developed at two competing research institutions. One key outcome of this probabilistic approach was the development of an intuitive measure of confidence which was indeed useful enough that a classification algorithm was developed based around alarming on high confidence targets. This paper will present and discuss results of this novel approach to accurately identifying shielded or masked radioisotopes with radiation detection systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗