Search NASASearch

SEARCH · Search NASA

Results for “radiometrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Railroad Valley Radiometric Calibration Test Site (RadCaTS) as Part of a Global Radiometric Calibration Network (RadCalNet)

The Radiometric Calibration Network (RadCalNet) is a coordinated multinational effort to provide in situ data that are suitable for the radiometric calibration and validation of Earth observation sensors that operate in the visible to shortwave infrared solar reflective spectral region (400 nm to 1000 nm). The main goals of RadCalNet are to provide top-of-atmosphere reflectance data to the scientific community, standardize data collection protocols for automated test sites, and to document the SI-traceable uncertainty budgets for each automated test site, of which there are currently four. The data available from RadCalNet are suitable for the calibration and validation of spaceborne imaging spectrometers. The work presented here provides a description of RadCalNet as well as a sample of the current results from the Radiometric Calibration Test Site (RadCaTS), which is located at Railroad Valley, Nevada, USA. Selected sensors for comparison include Terra and Aqua MODIS, SNPP and NOAA-20 VIIRS, and Sentinel-3A and -3B OLCI.

RadCalNet

Radiometric rectification - Toward a common radiometric response among multidate, multisensor images

A method is developed for relating scene digital counts among several images of the same scene by identifying radiometric control sets with mean reflectances that are basically constant. The average digital-count values of the control sets are utilized to compute linear transforms that relate digital count values between images. Two Landsat TM images are studied by means of the technique using simulations of a wide range of atmospheric conditions. In the visible and near-IR bands the algorithm effectively adjusts the surface reflectance for the effects of relative atmospheric differences to within 1 percent. The proposed method is found to be an effective relative correction procedure that can be used when atmospheric optical-depth data and calibration coefficients are not available.

Hall, F. G.

Simplified Vicarious Radiometric Calibration

A measurement-based radiance estimation approach for vicarious radiometric calibration of spaceborne multispectral remote sensing systems has been developed. This simplified process eliminates the use of radiative transfer codes and reduces the number of atmospheric assumptions required to perform sensor calibrations. Like prior approaches, the simplified method involves the collection of ground truth data coincident with the overpass of the remote sensing system being calibrated, but this approach differs from the prior techniques in both the nature of the data collected and the manner in which the data are processed. In traditional vicarious radiometric calibration, ground truth data are gathered using ground-viewing spectroradiometers and one or more sun photometer( s), among other instruments, located at a ground target area. The measured data from the ground-based instruments are used in radiative transfer models to estimate the top-of-atmosphere (TOA) target radiances at the time of satellite overpass. These TOA radiances are compared with the satellite sensor readings to radiometrically calibrate the sensor. Traditional vicarious radiometric calibration methods require that an atmospheric model be defined such that the ground-based observations of solar transmission and diffuse-to-global ratios are in close agreement with the radiative transfer code estimation of these parameters. This process is labor-intensive and complex, and can be prone to errors. The errors can be compounded because of approximations in the model and inaccurate assumptions about the radiative coupling between the atmosphere and the terrain. The errors can increase the uncertainty of the TOA radiance estimates used to perform the radiometric calibration. In comparison, the simplified approach does not use atmospheric radiative transfer models and involves fewer assumptions concerning the radiative transfer properties of the atmosphere. This new technique uses two neighboring uniform ground target areas having different reflectance values. The target areas can be natural or artificial and must be large enough to minimize adjacent-pixel contamination effects. The radiative coupling between the atmosphere and the terrain needs to be approximately the same for the two targets. This condition can be met for relatively uniform backgrounds when the distance between the targets is within a few hundred meters. For each target area, the radiance leaving the ground in the direction of the satellite is measured with a radiometrically calibrated spectroradiometer. Using the radiance measurements from the two targets, atmospheric adjacency and atmospheric scattering effects can be subtracted, thereby eliminating many assumptions about the atmosphere and the radiative interaction between the atmosphere and the terrain. In addition, the radiometrically calibrated spectroradiometer can be used with a known reflectance target to estimate atmospheric transmission and diffuse- to-global ratios without the need for ancillary sun photometers. Several comparisons between the simplified method and traditional techniques were found to agree within a few percent. Hence, the simplified method reduces the overall complexity of performing vicarious calibrations and can serve as a method for validating traditional radiative transfer models

Stanley, Thomas

NASA IKONOS Multispectral Radiometric Calibration and 3-Year Temporal Stability Assessment

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other system. In addition, the user community has little or no insight into the design and operation of commercial sensors or into the methods involved in generating commercial products. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) Directorate established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA, SSC,ESA, the University of Arizona Remote Sensing Group, and South Dacota State University. Each group determined the absolute radiometric calibration coefficients of the Space Imaging IKONOS 4-band, 4 m multispectral product covering the visible through near-infrared spectral region. For a three year period beginning in 2000, each team employed some variant of a reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with IKONOS image acquisitions and radiative transfer calculations. Several study sites throughout the United States were employed that covered nearly the entire dynamic range of the IKONOS sensor. IKONOS at-sensor radiance values were compared to those estimated by each independent group to determine the IKONOS sensor's radiometric accuracy and stability. Over 10 individual vicariously determined at-sensor radiance estimates were used each year. When combined, these estimates provided a high-precision radiometric gain calibration coefficient. No significant calibration offset was observed. The results of this evaluation provide the scientific community with an independent assessment of the IKONOS sensor's absolute calibration and temporal stability over the 3-year period. While the techniques and method described in this paper reflect those developed at the NASA SSC, the results of the entire team are included.

Pagnutti, Mary

JACIE Radiometric Assessment of QuickBird Multispectral Imagery

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) directorate,through the Joint Agency for Commercial Imagery Evaluation (JACIE) framework, established a commercial imaging satellite radiometric calibration team consisting of two groups: 1) NASA SSC ESA, supported by South Dakota State University, and 2) the University of Arizona Remote Sensing Group. The two groups determined the absolute radiometric calibration coefficients of the Digital Globe 4-band, 2.4-m QuickBird multispectral product covering the visible through near-infrared spectral region. For a 2-year period beginning in 2002, both groups employed some variant of a reflectance-based vicarious calibration approach, which required ground-based measurements coincident with QuickBird image acquisitions and radiative transfer calculations. The groups chose several study sites throughout the United States that covered nearly the entire dynamic range of the QuickBird sensor. QuickBird at-sensor radiance values were compared with those estimated by the two independent groups to determine the QuickBird sensor's radiometric accuracy. Approximately 20 at-sensor radiance estimates were vicariously determined each year. The estimates were combined to provide a high-precision radiometric gain calibration coefficient. The results of this evaluation provide the user community with an independent assessment of the QuickBird sensor's absolute calibration and stability over the 2-year period. While the techniques and method described reflect those developed at the NASA SSC, the results of both JACIE team groups are included in this paper.

Pagnutti, Mary

An Empirical Approach to Ocean Color Data: Reducing Bias and the Need for Post-Launch Radiometric Re-Calibration

A new empirical approach is developed for ocean color remote sensing. Called the Empirical Satellite Radiance-In situ Data (ESRID) algorithm, the approach uses relationships between satellite water-leaving radiances and in situ data after full processing, i.e., at Level-3, to improve estimates of surface variables while relaxing requirements on post-launch radiometric re-calibration. The approach is evaluated using SeaWiFS chlorophyll, which is the longest time series of the most widely used ocean color geophysical product. The results suggest that ESRID 1) drastically reduces the bias of ocean chlorophyll, most impressively in coastal regions, 2) modestly improves the uncertainty, and 3) reduces the sensitivity of global annual median chlorophyll to changes in radiometric re-calibration. Simulated calibration errors of 1% or less produce small changes in global median chlorophyll (less than 2.7%). In contrast, the standard NASA algorithm set is highly sensitive to radiometric calibration: similar 1% calibration errors produce changes in global median chlorophyll up to nearly 25%. We show that 0.1% radiometric calibration error (about 1% in water-leaving radiance) is needed to prevent radiometric calibration errors from changing global annual median chlorophyll more than the maximum interannual variability observed in the SeaWiFS 9-year record (+/- 3%), using the standard method. This is much more stringent than the goal for SeaWiFS of 5% uncertainty for water leaving radiance. The results suggest ocean color programs might consider less emphasis of expensive efforts to improve post-launch radiometric re-calibration in favor of increased efforts to characterize in situ observations of ocean surface geophysical products. Although the results here are focused on chlorophyll, in principle the approach described by ESRID can be applied to any surface variable potentially observable by visible remote sensing.

Gregg, Watson W.

Assessment of the Short-Term Radiometric Stability between Terra MODIS and Landsat 7 ETM+ Sensors

The Landsat 7 (L7) Enhanced Thematic Mapper (ETM+) sensor was launched on April 15th, 1999 and has been in operation for over nine years. It has six reflective solar spectral bands located in the visible and shortwave infrared part of the electromagnetic spectrum (0.5 - 2.5 micron) at a spatial resolution of 30 m. The on-board calibrators are used to monitor the on-orbit sensor system changes. The ETM+ performs solar calibrations using on-board Full Aperture Solar Calibrator (FASC) and the Partial Aperture Solar Calibrator (PASC). The Internal Calibrator Lamp (IC) lamps, a blackbody and shutter optics constitute the on-orbit calibration mechanism for ETM+. On 31 May 2003, a malfunction of the scan-line corrector (SLC) mirror assembly resulted in the loss of approximately 22% of the normal scene area. The missing data affects most of the image with scan gaps varying in width from one pixel or less near the centre of the image to 14 pixels along the east and west edges of the image, creating a wedge-shaped pattern. However, the SLC failure has no impacts on the radiometric performance of the valid pixels. On December 18, 1999, the Moderate Resolution Imaging Spectroradiometer (MODIS) Proto-Flight Model (PFM) was launched on-board the NASA's EOS Terra spacecraft. Terra MODIS has 36 spectral bands with wavelengths ranging from 0.41 to 14.5 micron and collects data over a wide field of view angle (+/-55 deg) at three nadir spatial resolutions of 250 m, 500 in 1 km for bands 1 to 2, 3 to 7, and 8 to 36, respectively. It has 20 reflective solar bands (RSB) with spectral wavelengths from 0.41 to 2.1 micron. The RSB radiometric calibration is performed by using on-board solar diffuser (SD), solar diffuser stability monitor (SDSM), space-view (SV), and spectro-radiometric calibration assembly (SRCA). Through the SV port, periodic lunar observations are used to track radiometric response changes at different angles of incidence (AOI) of the scan mirror. As a part of the AM Constellation satellites, Terra MODIS flies approximately 30 minutes behind L7 ETM+ in the same orbit. The orbit of L7 is repetitive, circular, sunsynchronous, and near polar at a nominal altitude of 705 km (438 miles) at the Equator. The spacecraft crosses the Equator from north to south on a descending node between 10:00 AM and 10:15 AM. Circling the Earth at 7.5 km/sec, each orbit takes nearly 99 minutes. The spacecraft completes just over 14 orbits per day, covering the entire Earth between 81 degrees north and south latitude every 16 days. The longest continuous imaging swath that L7 sensor can collect is for a 14-minute subinterval contact period which is equivalent to 35 full WRS-2 scenes. On the other hand, Terra can provide the entire corresponding orbit with wider swath at any given ETM+ collection without contact time limitation. There are six spectral matching band pairs between MODIS (bands 3, 4, 1, 2, 6, 7) and ETM+ (bands 1, 2, 3, 4, 5, 7) sensor. MODIS has narrower spectral responses than ETM+ in all the bands. A short-term radiometric stability was evaluated using continuous ETM+ scenes within the contact period and the corresponding half orbit MODIS scenes. The near simultaneous earth observations (SNO) were limited by the smaller swath size of ETM+ (187 km) as compared to MODIS (2330 km). Two sets of continuous granules for MODIS and ETM+ were selected and mosaiced based on pixel geolocation information for non cloudy pixels over the North American continent. The Top-of- Atmosphere (TOA) reflectances were computed for the spectrally matching bands between ETM+ and MODIS over the regions of interest (ROI). The matching pixel pairs were aggregated from a finer to a coarser pixel resolution and the TOA reflectance values covering a wide dynamic range of the sensors were compared and analyzed. Considering the uncertainties of the absolute calibration of the both sensors, radiometric stability was verified for the band pairs. The Railroad Valley Playa, Nada (RVPN) was included in the path of this continuous orbit, which served as a verification point between the shortterm and the long-term trending results from previous studies. This work focuses on monitoring the short-term on-orbit stability of MODIS and the ETM+ RSB. It also provides an assessment of the absolute calibration differences between the two sensors over their wide dynamic ranges.

Choi, Taeyoung

Lessons Learned from the AIRS Pre-Flight Radiometric Calibration

The Atmospheric Infrared Sounder (AIRS) instrument flies on the NASA Aqua satellite and measures the upwelling hyperspectral earth radiance in the spectral range of 3.7-15.4 micron with a nominal ground resolution at nadir of 13.5 km. The AIRS spectra are achieved using a temperature controlled grating spectrometer and HgCdTe infrared linear arrays providing 2378 channels with a nominal spectral resolution of approximately 1200. The AIRS pre-flight tests that impact the radiometric calibration include a full system radiometric response (linearity), polarization response, and response vs scan angle (RVS). We re-derive the AIRS instrument radiometric calibration coefficients from the pre-flight polarization measurements, the response vs scan (RVS) angle tests as well as the linearity tests, and a recent lunar roll test that allowed the AIRS to view the moon. The data and method for deriving the coefficients is discussed in detail and the resulting values compared amongst the different tests. Finally, we examine the residual errors in the reconstruction of the external calibrator blackbody radiances and the efficacy of a new radiometric uncertainty model. Results show the radiometric calibration of AIRS to be excellent and the radiometric uncertainty model does a reasonable job of characterizing the errors.

Sounder

The Radiometric Scaling of the MODIS and VIIRS Imagers to a Common Reference and Stability Analysis for the Next Edition of CERES Products

The NASA CERES project has provided the climate quality observed TOA and computed surface fluxes to the scientific community. CERES uses MODIS and VIIRS imagers to retrieve cloud properties needed to convert Terra, Aqua, NPP, and NOAA-20 CERES footprint radiance observations into fluxes. The imagers are also used to radiometrically scale the geostationary sensors (GEO) radiances to the imager calibration reference to ensure that the GEO derived cloud properties and broadband TOA fluxes are consistent in both space and time. Both the imager and GEO retrieved cloud properties are used to compute the surface fluxes. The CERES imager and GEO calibration team uses ray-matched radiance pairs to radiometrically scale the SNPP and NOAA-20 VIIRS sensors to the Aqua-MODIS calibration reference. The radiometric scaling is further validated using geostationary imagers as transfer radiometers. The team will rely primarily on deep convective clouds to monitor the imager channel calibration stability and to correct for short term calibration drifts. The DSCOVR satellite was launched on February 25, 2015 and orbits around the L1 Lagrange point directly between the Earth and the sun. The EPIC sensor contains no onboard calibration systems. However, multiple inter-calibration studies have shown that the EPIC imager is very stable in time. The excellent radiometric stability of EPIC allows the use of EPIC observations as a stable reference to validate both the short term drift corrections of the imagers, as well as to validate the radiometric scaling factors between them. Examples of the imager relative calibration using EPIC before and after radiometric scaling will be shown along with the results from the use of invariant targets to remove imager calibration drifts.

DSCOVR-EPIC

Preliminary Evaluation of the Radiometric Calibration of LANDSAT-4 Thematic Mapper Data by the Canada Centre for Remote Sensing

The radiometric characteristics of the LANDSAT-4 TM sensor are being studied with a view to developing absolute and relative radiometric calibration procedures. Preliminary results from several different approaches to the relative correction of all detectors within each band are reported. Topics covered include: the radiometric correction method; absolute calibration; the relative radiometric calibration algorithm; relative gain and offset calibration; relative gain and offset observations; and residual radiometric stripping.

Murphy, J.

Radiometric Measurement Comparisons Using Transfer Radiometers in Support of the Calibration of NASA's Earth Observing System (EOS) Sensors

EOS satellite instruments operating in the visible through the shortwave infrared wavelength regions (from 0.4 micrometers to 2.5 micrometers) are calibrated prior to flight for radiance response using integrating spheres at a number of instrument builder facilities. The traceability of the radiance produced by these spheres with respect to international standards is the responsibility of the instrument builder, and different calibration techniques are employed by those builders. The National Aeronautics and Space Administration's (NASA's) Earth Observing System (EOS) Project Science Office, realizing the importance of preflight calibration and cross-calibration, has sponsored a number of radiometric measurement comparisons, the main purpose of which is to validate the radiometric scale assigned to the integrating spheres by the instrument builders. This paper describes the radiometric measurement comparisons, the use of stable transfer radiometers to perform the measurements, and the measurement approaches and protocols used to validate integrating sphere radiances. Stable transfer radiometers from the National Institute of Standards and Technology, the University of Arizona Optical Sciences Center Remote Sensing Group, NASA's Goddard Space Flight Center, and the National Research Laboratory of Metrology in Japan, have participated in these comparisons. The approaches used in the comparisons include the measurement of multiple integrating sphere lamp levels, repeat measurements of select lamp levels, the use of the stable radiometers as external sphere monitors, and the rapid reporting of measurement results. Results from several comparisons are presented. The absolute radiometric calibration standard uncertainties required by the EOS satellite instruments are typically in the +/- 3% to +/- 5% range. Preliminary results reported during eleven radiometric measurement comparisons held between February 1995 and May 1998 have shown the radiance of integrating spheres agreed to within +/- 2.5% from the average at blue wavelengths and to within +/- 1.7% from the average at red and near infrared wavelengths. This level of agreement lends confidence in the use of the transfer radiometers in validating the radiance scales assigned by EOS instrument calibration facilities to their integrating sphere sources.

Butler, James J.

Radiometric Characterization Results for the IKONOS, Quickbird, and OrbView-3 Sensor

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities better understand commercial imaging satellite properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Applied Sciences Directorate (ASD) at Stennis Space Center established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA ASD, the University of Arizona Remote Sensing Group, and South Dakota State University. Each group independently determined the absolute radiometric calibration coefficients of available high-spatial-resolution commercial 4-band multispectral products, in the visible though near-infrared spectrum, from GeoEye(tradeMark) (formerly SpaceImaging(Registered TradeMark)) IKONOS, DigitalGlobe(Regitered TradeMark) QuickBird, and GeoEye (formerly ORBIMAGE(Registered TradeMark) OrbView. Each team member employed some variant of reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with image acquisitions and radiative transfer calculations. Several study sites throughout the United States that covered a significant portion of the sensor's dynamic range were employed. Satellite at-sensor radiance values were compared to those estimated by each independent team member to evaluate the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these sensors' absolute calibration values.

Holekamp, Kara

Solar Tower Experiments for Radiometric Calibration and Validation of Infrared Imaging Assets and Analysis Tools for Entry Aero-Heating Measurements

The NASA Engineering and Safety Center sponsored Hypersonic Thermodynamic Infrared Measurements assessment team has a task to perform radiometric calibration and validation of land-based and airborne infrared imaging assets and tools for remote thermographic imaging. The IR assets and tools will be used for thermographic imaging of the Space Shuttle Orbiter during entry aero-heating to provide flight boundary layer transition thermography data that could be utilized for calibration and validation of empirical and theoretical aero-heating tools. A series of tests at the Sandia National Laboratories National Solar Thermal Test Facility were designed for this task where reflected solar radiation from a field of heliostats was used to heat a 4 foot by 4 foot test panel consisting of LI 900 ceramic tiles located on top of the 200 foot tall Solar Tower. The test panel provided an Orbiter-like entry temperature for the purposes of radiometric calibration and validation. The Solar Tower provided an ideal test bed for this series of radiometric calibration and validation tests because it had the potential to rapidly heat the large test panel to spatially uniform and non-uniform elevated temperatures. Also, the unsheltered-open-air environment of the Solar Tower was conducive to obtaining unobstructed radiometric data by land-based and airborne IR imaging assets. Various thermocouples installed on the test panel and an infrared imager located in close proximity to the test panel were used to obtain surface temperature measurements for evaluation and calibration of the radiometric data from the infrared imaging assets. The overall test environment, test article, test approach, and typical test results are discussed.

Splinter, Scott C.

The Landsat Data Continuity Mission Operational Land Imager (OLI) Radiometric Calibration

The Operational Land Imager (OLI) on the Landsat Data Continuity Mission (LDCM) has a comprehensive radiometric characterization and calibration program beginning with the instrument design, and extending through integration and test, on-orbit operations and science data processing. Key instrument design features for radiometric calibration include dual solar diffusers and multi-lamped on-board calibrators. The radiometric calibration transfer procedure from NIST standards has multiple checks on the radiometric scale throughout the process and uses a heliostat as part of the transfer to orbit of the radiometric calibration. On-orbit lunar imaging will be used to track the instruments stability and side slither maneuvers will be used in addition to the solar diffuser to flat field across the thousands of detectors per band. A Calibration Validation Team is continuously involved in the process from design to operations. This team uses an Image Assessment System (IAS), part of the ground system to characterize and calibrate the on-orbit data.

Markham, Brian L.

Early Radiometric Performance of Landsat-9 Thermal Infrared Sensor

Landsat-9, launched on September 27, 2021, carries the Thermal Infrared Sensor (TIRS). The Landsat-9 TIRS is a close copy of the Landsat-8 TIRS instrument; it is a two spectral-band, pushbroom sensor with three Sensor Chip Assemblies (SCAs) that cover the 15-degree field-of-view. The primary radiometric change between the instruments is the addition of baffling in the Landsat-9 TIRS telescope to mitigate the stray light issue that has impacted the radiometric quality of Landsat-8 TIRS. The on-orbit radiometric performance is monitored using the on-board variable temperature blackbody and views of deep space. Maneuvers to look at and around the moon have provided an assessment of the stray light. The absolute calibration is monitored by vicarious calibration techniques by teams at NASA/Jet Propulsion Lab and the Rochester Institute of Technology. Landsat-9 completed a three-month commissioning phase in January 2022 and has been operational since February 2022. The instrument has demonstrated excellent radiometric performance, as assessed from the on-orbit measurements. The TIRS instrument is radiometrically stable to 0.1% within a power cycle, and has noise levels below 0.1K. The lunar scans and the vicarious calibration data provide evidence that the stray light has been effectively mitigated.

Landsat-9

On-Orbit Radiometric Characterization of OLI (Landsat 8) for Applications in Aquatic Remote Sensing

Landsat-8 carries two separate sensors, namely the Operational Land Imager (OLI) and the Thermal Infrared Radiometer Suite (TIRS), that image the earth surface throughout the visible and thermal portions of the spectrum. Compared to Landsat heritage sensors, the OLI has enhanced features, which include its 12-bit radiometric resolution and the addition of a band centered at 443 nm. The dramatically improved data quality/quantity expands existing applications of Landsat imagery in aquatic sciences from the retrieval of bio-geochemical properties, such as near-surface concentrations of chlorophyll-a (CHL) and total suspended solids (TSS), to benthic mapping. This study offers analysis of OLI's absolute radiometric performance over bodies ofwater using benchmark observations, namely the top-of-atmosphere (TOA) ocean color observations and marine in situ radiometric measurements. Sensor-to-sensor comparisons are performed to derive gain factors (g1) from near-concurrent observations in TOA radiance and reflectance domains. The gains in the radiance domain were further validated/adjusted by determining a second set of gains (g2) via analysis of OLI-derived water-leaving radiance, i.e., L(sub w) (gamma), against in situ measurements made either at the Ocean Color AErosol RObotic NETwork (AERONETOC) sites or during field campaigns. The analyses yield the OLI calibration uncertainties that need to be accounted forwhen studying aquatic environments. Itwas found that, for the visible and near-infrared channels, the OLI radiometric responses, on average, are well in agreement (b 2 % discrepancies) with the TOA radiances estimated by ocean color satellites or those predicted by models based onmeasurements of aquatic and atmospheric properties. However, the TOA radiance at the new 443-nm band is found to be, on average, 3.4 % larger than the reference observations. The inter-sensor comparisons in the reflectance domain, however, indicated slightly different results with the OLI responses being low in the blue bands. To enhance the retrieval accuracy of aquatic-science products from OLI datasets, sets of temporally averaged gains (radiance and reflectance) are derived and recommended for use prior to the retrieval of in-water products.

Remote Sensing

Radiometric performance of the Voyager cameras

The Voyager Imaging Experiment provided high-quality data of Jupiter and the Galilean satellites with the two flyby trajectories in March and July of 1979. Moderately accurate radiometric measurements have been made using these data. This paper evaluates the radiometric results and describes the inflight and ground geometric and radiometric correction factors. The radiometric quantities of intensity I and geometric albedo I/F are derived, and scaling factors for each of the filters are tabulated for correcting the 'calibrated' data from the Image Processing Laboratory at JPL. In addition, the key characteristics of both Voyager I and Voyager 2 cameras are tabulated.

Danielson, G. E.