Search NASA⌕ Search

SEARCH · Search NASA

Results for “raman spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Raman Spectroscopy

Raman spectroscopy is one of the mostly utilized optical spectroscopic tools for revealing both the catalyst structure and surface chemistry in heterogeneous catalysis. It has recently seen increasing role in catalysis research, thanks to the development of new Raman instrumentations, reactors, and combination with other techniques, leading to in situ and operando studies with significant temporal and spatial resolutions. This chapter aimed to provide a general overview of the applications of Raman spectroscopy in heterogeneous catalysis. It starts with an introduction to the fundamentals of Raman scattering including theory and pros and cons for catalysis research; followed by a description of the typical setup of a Raman system and recent advances in Raman instrumentations; then a chronology of the applications of Raman spectroscopy for ex situ, in situ, and operando studies of catalysis; elucidations of the advances in improving the temporal and spatial resolution of Raman spectroscopy of catalysis; Raman application case studies related to catalyst synthesis, treatments, and function under reaction conditions; illustrations of the power of multimodal approach including Raman spectroscopy in catalysis research; and ended with a brief summary and a future outlook.

Braatz, Jisue↗

Raman Spectroscopy

Raman spectroscopy is one of the mostly utilized optical spectroscopic tools for revealing both the catalyst structure and surface chemistry in heterogeneous catalysis. It has recently seen increasing role in catalysis research, thanks to the development of new Raman instrumentations, reactors, and combination with other techniques, leading to in situ and operando studies with significant temporal and spatial resolutions. This chapter aimed to provide a general overview of the applications of Raman spectroscopy in heterogeneous catalysis. It starts with an introduction to the fundamentals of Raman scattering including theory and pros and cons for catalysis research; followed by a description of the typical setup of a Raman system and recent advances in Raman instrumentations; then a chronology of the applications of Raman spectroscopy for ex situ, in situ, and operando studies of catalysis; elucidations of the advances in improving the temporal and spatial resolution of Raman spectroscopy of catalysis; Raman application case studies related to catalyst synthesis, treatments, and function under reaction conditions; illustrations of the power of multimodal approach including Raman spectroscopy in catalysis research; and ended with a brief summary and a future outlook.

Braatz, Jisue↗

A novel method for quantifying irradiation damage in nuclear graphite using Raman spectroscopy

Raman spectroscopy has long been used in studying irradiation damage in carbon/graphite materials. It is however unclear if the measurements from different types of materials are directly comparable. Further, decoupling the contribution from irradiation temperature and fluence to the total damage in nuclear graphite possessing irradiation damage gradient is currently not readily feasible as it requires a complete set of test reactor irradiation experiments over the relevant temperature and fluence range. A novel methodology has therefore been proposed and developed to quantify total irradiation damage evolution at crystal level based on graphite Raman G-band position shift. Specifically, G-band positions derived from a large number of spectra collected from the fractured surface of microfine-grained POCO ZXF-5Q graphite possessing proton irradiation damage gradient were plotted with open literature Raman data on HOPG, BEPO (AXGP graphite), PCEA and IG-110 graphite as a function of dpa. The total damage level within 2σ beam radius in this POCO graphite was estimated to be equivalent to ~2–5 dpa at ~350–370 °C. Derived G-band positions were then mapped to the three-stage amorphization trajectory model indicating beam centre area has entered the second stage, i.e., transitioning from nanocrystalline graphite into amorphous carbon. G-band position relative shift (ΔG) curve with a ‘turn-around’ peak as a function of total damage can be used for in-service lifetime prediction. Importantly, the developed methodology has the potential to ‘unify’ total damage levels across different grades of nuclear graphite caused by ion, neutron and proton irradiation at different temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a Structural Transformation of Carbon Nanotube Materials by Raman Spectroscopy

Raman spectra of carbon nanotubes and carbon microstructure materials synthesized on Si substrates by pulsed laser vaporization have been measured in the range of 50/cm to 4500/cm with the excitation of He-Ne laser. It is found that the formation of nanotubes depends strongly on the growth temperatures and high quality multi-wall and single-wall nanotubes were produced at 700 and 990 C, respectively. The Raman spectra of one sample grown at 700 C were found to be dependent on the excitation intensity. The spectra of the sample suggest that the structure is similar to that of multi-wall nanotubes at low excitation intensity (2.5 kW/sq cm) and it converts to the structure of single-wall nanotubes at higher intensity (25 kW/sq cm). Measurements taken while cycling the light intensity indicate a reversible structural transition.

Cui, Y.↗

Nanoindentation-Enhanced Tip-Enhanced Raman Spectroscopy

We combine nanoindentation, herein achieved using atomic force microscopy (AFM)-based pulsed-force lithography, with tip-enhanced Raman spectroscopy (TERS) and imaging. Our approach entails indentation and multimodal characterization of otherwise flat Au substrates, followed by chemical functionalization and TERS spectral imaging of the indented nanostructures. We find that the resulting structures, which vary in shape and size depending on the tip used to produce them, may sustain nano-confined and significantly enhanced local fields. We take advantage of the latter and illustrate TERS-based ultrasensitive detection/chemical fingerprinting as well as chemical reaction imaging – all using a single platform for nano-lithography, topographic imaging, hyperspectral dark field optical microscopy, and TERS.

Wang, Chih-Feng↗

Plastic deformation mechanism of calcium-silicate hydrates determined by deviatoric-stress Raman spectroscopy

Highlights: • C-(A-)S-H samples under stress were characterized at the bond and grain level. • Small angle scattering showed that 720 MPa reduced grain thickness by 30%. • In-situ Raman showed that cross-linked C-A-S-H slips along its intralayer. • However, in-situ Raman showed that C-S-H slips along the interlayer. • In-situ Raman also showed a growth in CaCO{sub 3}, indicating fracture in both samples. Creep of the cement matrix affects the structural stability of concrete. In Portland cements, the creep is largely controlled by the binding phase calcium-(aluminum-)silicate-hydrate, or C-(A-)S-H. This phase has a lamellar structure and under deviatoric stress aligns its c-axis with the principal stress. However, the limiting resistance to this reorientation is unknown at the nanocrystalline level. Small-angle X-ray scattering shows that the lamellae thickness decreases under 100's MPa deviatoric stress. Deviatoric stress Raman spectroscopy shows that there are two ways that this break-up can occur. If the material's silicate chains are cross-linked, then strain in SiO bonds does not increase above certain stresses, indicating a relaxation adjacent to the SiO bond. If the chains are not cross-linked, then the silicate chains are broken up by rastering against each other, introducing defects. These results show that the plastic deformation of C-(A-)S-H is relevant for Portland cement creep.

36 MATERIALS SCIENCE↗

Enhanced Carbon Dioxide Uptake in Drilled Hollow Core Fibers for Raman Spectroscopy

Fiber-based Raman spectroscopy enhances the Raman signal by maximizing the overlap of the optical field and the gas species. However, filling the hollow-core fiber (HCF) with gas requires time that is dependent on the fiber core diameter, fiber length, and pressure of the gas. At ambient pressure, the fiber gas uptake is driven by diffusion into the fiber ends, severely limiting the response time of the system. By laser drilling access holes to the core along the length of the fiber, the uptake time of the gas is reduced, improving the system response time. In this work, we study the carbon dioxide (CO 2 ) sensor dynamics based on Raman signal intensity generated in HCFs. The signal intensity versus gas concentration is characterized by controlling the CO 2 concentration in the surrounding environment of the fiber. Next, we characterize the gas uptake time in HCFs as a function of fiber length. Finally, we optimize the access hole configuration along the fiber, demonstrating reduced sensor uptake time by a factor of three.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Planetary Mineralogy Using Simultaneous Time Resolved Fluorescence and Raman Spectroscopy

Micro-Raman spectroscopy is one of the primary methods of mineralogical analysis in the laboratory, and more recently in the field. Because of its versatility and ability to interrogate rocks in their natural form it is one of the front runners for the next generation of in situ instruments designed to explore adverse set of solar system bodies (e.g. Mars, Venus, the Moon, and other primitive bodies such as asteroids and the Martian moons Phobos and Deimos), as well as for pre-selection of rock and soil samples for potential cache and return missions.

miniature microchip laser↗

Temperature profiles of inhibited flames using Raman spectroscopy

Laser Raman scattering from vibrational and rotational states of N2 and H2 has been used to determine temperature profiles for several H2/O2/N2 flames with and without HBr present. The inhibiting effect of HBr is clearly demonstrated and the derived properties of burning velocity and inhibition index are in good agreement with previous experimental measurements and theoretical calculations.

Drake, M. C.↗

Time-Gated Raman Spectroscopy (Intern Final Report)

Time-gated Raman spectroscopy is a powerful tool for rapid non-destructive analysis of chemical compounds, particularly when combined with other investigative methods. Time-gating the signal obtained from a sample during Raman spectroscopy allows for the removal of background emission and black body radiation, improving clarity and accuracy of scans. The main objectives of this project were to prove the lab’s time-gated Raman spectroscopy system works as proof of concept and to make select improvements to the in-house LabVIEW software used to run the time-gated system. This time-gated system will be added to the CTK’s TAP reactors in the future, but this is out of the scope of this internship project. This research is important, as understanding the mechanisms behind catalysts leads to designing better systems/materials and the perfection of catalysts, and energy-efficient chemical manufacturing is key when designing a greener future. The research for this project was done with samples at both ambient conditions in sample holders and at operando conditions (i.e., high temperature, unsteady-state) inside a small-volume chemical reactor. Numerous spectro-kinetic scans of the catalysts were obtained, but the advanced dynamics of these systems are still being interpreted. There is data that demonstrates that the time-gated system is correctly rejecting emission from samples, and one can observe real-time changes in the signal from the sample, due to coking or changes induced by redox chemistry. Chemical manufacturers and the planet are the main beneficiaries of catalysis research, as better catalysts will reduce carbon emissions.

36 MATERIALS SCIENCE↗

Studies of Minerals, Organic and Biogenic Materials through Time-Resolved Raman Spectroscopy

A compact remote Raman spectroscopy system was developed at NASA Langley Research center and was previously demonstrated for its ability to identify chemical composition of various rocks and minerals. In this study, the Raman sensor was utilized to perform time-resolved Raman studies of various samples such as minerals and rocks, Azalea leaves and a few fossil samples. The Raman sensor utilizes a pulsed 532 nm Nd:YAG laser as excitation source, a 4-inch telescope to collect the Raman-scattered signal from a sample several meters away, a spectrograph equipped with a holographic grating, and a gated intensified CCD (ICCD) camera system. Time resolved Raman measurements were carried out by varying the gate delay with fixed short gate width of the ICCD camera, allowing measurement of both Raman signals and fluorescence signals. Rocks and mineral samples were characterized including marble, which contain CaCO3. Analysis of the results reveals the short (approx.10-13 s) lifetime of the Raman process, and shows that Raman spectra of some mineral samples contain fluorescence emission due to organic impurities. Also analyzed were a green (pristine) and a yellow (decayed) sample of Gardenia leaves. It was observed that the fluorescence signals from the green and yellow leaf samples showed stronger signals compared to the Raman lines. Moreover, it was also observed that the fluorescence of the green leaf was more intense and had a shorter lifetime than that of the yellow leaf. For the fossil samples, Raman shifted lines could not be observed due the presence of very strong short-lived fluorescence.

Garcia, Christopher S.↗

Advancing Enhanced Raman Spectroscopy to Detect and Measure NOW Pheromones (CPRB 2022 proposal)

Insect sex pheromones are chemical compounds that insects release to attract their partners over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. These pheromone-based strategies can include monitoring, mating disruption, mass trapping, attract-and-kill and push-pull. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage by this pest. Just how mating disruption works is not fully established and likely varies across products and target species. For instance, the extent to which synthetic pheromones compete with natural pheromone is not well understood, or in the case of monitoring, how efficaciously the insect follows the diffusing plumes, especially across large blocks and at plot borders. Furthermore, there may be specific conditions under which poor or impeded diffusion of synthetic pheromone diminishes the disruption effect, which could result in some males effectively locating females for reproduction. At the same time, many commercially available synthetic lures are also available, and growers have been effectively using them to track population development – although the attractive range of these lures remains unclear. That is, while pheromone lures can attract many moths, the relationship between trap capture and local populations, much less crop damage, remains unclear. Regardless of the emission source (aerosol puffers, meso emitters, lures etc.), we currently lack the ability to fully understand how these synthetic pheromone compounds diffuse away from their point-source of emission – and subsequently how this might affect the efficacy of mating disruption and/or the accuracy of monitoring efforts. Raman spectroscopy (RS) may offer a means to detect synthetic pheromone because of its analytical properties and recent technological advancements. In combination with nanostructured probes, RS has a demonstrated capability to detect volatiles at extremely low concentrations. While other methods for detecting pheromones have proven to be successful, such analytical methods like mass spectrometry (MS) gas chromatography (GC) require sampling in the fields and are not real-time. Other methods such as EAG/ EAD are also invasive (use antennas) but are of course valuable. Opto-electronic, micro and nano sensors just recently enticed interest. We fall in this latter category, proposing the use of optical spectroscopy (Raman) in a fiber aided by nanostructures to provide a chemical fingerprint without transductions and in real-time (i.e. no sampling). To date, we have been able to generate Raman signatures for the main chemicals in synthetic pheromones (a first for science, to the best of our knowledge), observe their trends at different concentrations, and also provide a clear distinction of such signatures in mixed samples via Principal Component Analysis (PCA) – all of which strengthens our conclusions on the ability of RS to detect emissions in more realistic conditions. We also established processes to enhance the detection sensitivity via preconcentration with Solid Phase Micro Extraction (SPME) fibers and Surface Enhanced Raman Spectroscopy (SERS) to increase the overall optical signals. Furthermore, we explored limitations and requirements for detecting from dispensers, lures, or live moths, including Dept. of Energy and CA State regulatory approvals. Finally, we setup some of our first “orchard in a box” experiments to measure pheromone diffusion along with developing appropriate models.

42 ENGINEERING↗

Constructing a Raman Spectroscopy System

The project aims to understand how Raman spectroscopy works by constructing a system based on existing concepts of the technique and utilizing NASA’s available tools and software to analyze the collected data. Once the data is successfully interpreted and proven, other improvements to the assembled system will then be explored. Part of the paper goes through several phases of construction of the system and improvements made. Nevertheless, the data obtained and the results were unsatisfactory as they need to be further analyzed for accuracy. The ultimate ambition was to be able to assist NASA with its objective of implementing a remote and compact Raman spectroscopy system on a rover for future planetary surface characterization such as Mars and lunar surfaces via a Raman spectroscopy system that the agency’s Senior Engineer, Dr. M. Nurul Abedin, has been working on since the early 2000s [2,3,4].

Jake Nguyen↗