Search NASA⌕ Search

SEARCH · Search NASA

Results for “range hood”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Factors Impacting Range Hood Use in California Houses and Low-Income Apartments

Venting range hoods can control indoor air pollutants emitted during residential cooktop and oven cooking. To quantify their potential benefits, it is important to know how frequently and under what conditions range hoods are operated during cooking. We analyzed data from 54 single family houses and 17 low-income apartments in California in which cooking activities, range hood use, and fine particulate matter (PM 2.5 ) were monitored for one week per home. Range hoods were used for 36% of cooking events in houses and 28% in apartments. The frequency of hood use increased with cooking frequency across homes. In both houses and apartments, the likelihood of hood use during a cooking event increased with the duration of cooktop burner use, but not with the duration of oven use. Actual hood use rates were higher in the homes of participants who self-reported more frequent use in a pre-study survey, but actual use was far lower than self-reported frequency. Residents in single family houses used range hoods more often when cooking caused a discernible increase in PM 2.5 . In apartments, residents used their range hood more often only when high concentrations of PM 2.5 were generated during cooking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Range Hood Use and Effectiveness in Reducing Indoor Air Pollution During Gas and Induction Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. The study installed electric induction stoves and repeated measurements over three 2-week intensive periods, at baseline and at the end of two consecutive 3-month study phases. Stove replacements occurred at the start of Phase 1 or Phase 2 by random assignment. There were 4184 cooking events identified by automated analysis of time-series data from temperature sensors mounted above the cooktops and 1038 related range hood usage events detected from data recorded by anemometers, smart plugs, or motor loggers. Analysis of 1-minute resolved PM2.5 and NO 2 data identified and quantified 2685 PM 2.5 events and 2606 NO 2 events. Range hood use was characterized as a binary variable (>3 min vs. <3 min use). Range hood use was more common during cooking events associated with particle emissions and longer cooking durations. PM 2.5 concentrations during events with range hood use were comparable to those without use, which could result from limited effectiveness or if range hoods were preferentially used during higher-emission cooking scenarios. In homes with gas cooking, integrated NO 2 concentrations were about 45 percent higher during cooking events with no range hood use compared to those range hood use. The lowest pollutant levels were observed when the range hood operated for more than half of the cooking duration. These findings show that operation of venting range hood during cooking can substantially reduce short-term indoor exposure NO 2 in homes with gas cooking.

Fang, Yi↗

Measured Performance of Over the Range Microwave Range Hoods

The California residential building code requires kitchen exhaust ventilation to protect indoor air quality. The requirement can be met with a kitchen exhaust fan or a range hood that conforms to airflow and sound specifications based on certified, standard test results. Appliances that integrate an exhaust fan with an over the range microwave (OTRs) are popular for their space saving utility; but for years there were none with the certified performance data required for building code compliance. This project, initiated during that period, aimed to evaluate OTR models found in new California homes and compare their performance to range hoods that minimally met code requirements. The study aimed to expand on limited information available about OTR performance with a particular focus on measuring the fraction of cooktop-generated air pollutants that are captured and removed by the exhaust devices, a parameter called “capture efficiency”. Airflow and capture efficiency (CE) were measured in a simulated kitchen in Berkeley Lab’s FLEXLAB facility. Airflows were measured using several variations of a balanced-pressure flow method (Walker et al. 2001) including a protocol that had been used in the California Healthy Efficient New Gas Homes (HENGH) field study. Measurements were made for six OTRs observed in the field study, including three with certified test results (published after the start of this project) for airflow and sound. Measurements were also made on two standard range hoods with comparable airflows and costs to the OTRs, when accounting for the microwave functionality. CE was measured using the CO 2 emitted from burners while heating pots of water (POW) as a tracer and calculating the ratio of added CO 2 in the exhaust flow over the total CO 2 generated from burning fuel. Results show that OTRs generally met the California code requirements for airflow, which are the same as those of the residential ventilation standard of ASHRAE. It was determined that the field protocol used in HENGH study homes was biased low by ~14% on average. The CE performance of OTRs tested in this study were consistent with those tested under controlled conditions in prior studies, showing CE increasing with airflow and being higher for emissions occurring at the back cooktop burner(s) compared with front burner emissions. The measured CE covered a range of 40% to 85% for the front burners and 60% to 100% for the back burners. The relationship of CE to airflow for OTRs was within the range of those found for standard range hoods in this study and prior studies, with the key caveat that OTRs appear to have more consistent CE performance for emissions on the front burner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Residential Smart Range Hood

This report documents the development testing of a residential smart range hood for automated mitigation of air pollutants generated during cooking events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured air quality impacts after teaching parents about cooking ventilation with a video: a pilot study

BackgroundCooking-related emissions contribute to air pollutants in the home and may influence children’s health outcomes.ObjectiveIn this pilot study, we investigate the effects of a cooking ventilation intervention in homes with gas stoves, including a video-based educational intervention and range hood replacement (when needed) in children’s homes.MethodsThis was a pilot (n = 14), before-after trial (clinicaltrials.gov #NCT04464720) in homes in the San Francisco Bay Area that had a school-aged child, a gas stove, and either a venting range hood or over-the-range microwave/hood. Cooking events, ventilation use, and indoor air pollution were measured in homes for 2–4 weeks, and children completed respiratory assessments. Midway, families received this intervention: (1) education about the hazards of cooking-related pollutants and benefits of both switching to back burners and using the range hood whenever cooking and (2) ensuring the range hood met airflow and sound performance standards. The educational intervention was delivered via a video developed in conjunction with local youth.ResultsWe found substantially increased use of back burners and slight increases in range hood use during cooking after intervening. Even though there was no change in cooking frequency or duration, these behavior changes resulted in decreases in nitrogen dioxide (NO2), including significant decreases in the total integrated concentration of NO2 over all cooking events from 1230 ppb*min (IQR 336, 7861) to 756 (IQR 84.0, 4210; p < 0.05) and NO2 collected on samplers over the entire pre- and post-intervention intervals from 10.4 ppb (IQR 3.5, 47.5) to 9.4 (IQR 3.0, 36.1; p < 0.005). There were smaller changes in PM2.5, and no changes were seen in respiratory outcomes.ImpactThis pilot before-after trial evaluated the use of a four-minute educational video to improve cooking ventilation in homes with gas stoves and one or more school-aged children. Participant behavior changed after watching the video, and there were decreases in indoor air pollutant concentrations in the home, some of which were significant. This brief video is now publicly available in English and Spanish (wspehsu.ucsf.edu/projects/indoor-air-quality), and this provides suggestive evidence of the utility of this simple intervention, which could be particularly beneficial for households that have children with asthma.

Holm, Stephanie M↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

Effective Kitchen Ventilation for Healthy Zero Net Energy Homes with Natural Gas

Past studies indicate that kitchen ventilation that minimally complies with California’s Residential Building Code is inadequate at controlling combustion pollutants from natural gas burners and particulate matter produced during cooking. Effectiveness is further limited by misperceptions that kitchen ventilation is infrequently needed. This project developed the technical basis for updating kitchen ventilation requirements to protect health in new California homes, especially in smaller homes common among low-income renters. Tasks included (1) a field study of ventilation equipment performance and indoor air quality in 23 low-income apartments at four sites; (2) analysis of range hood use related to cooking time and household parameters using data from 54 houses and 17 low-income apartments; (3)a measurement-based study to quantify performance of over-the-range microwave ovens with integrated exhaust fans;and (4) pollutant exposure simulations to inform capture efficiency standards.The field study found operational deficiencies with mechanical ventilation systems in a substantial fraction of low-income apartments that affected performance, resulting in higher exposures to pollutants generated indoors. Using gas cooking burners produced high short-term and weekly time-averaged nitrogen dioxide in apartments.Range hoods were used more frequently with cooking in houses (36percent) than apartments (28percent); use increased with overall cooking frequency in a home and with duration of cooktop but not oven events; actual use was correlated to, but lower than,self-reported use;and use was more frequent in houses when cooking generated any fine particulate matter (PM2.5)or when high PM2.5resulted from cooking in apartments. Performance of over-the-range microwaves with integrated exhaust fans was similar to that of range hoods of comparable price. Simulation analysis found that performance standards need to be updated to ensure that kitchen exhaust ventilation adequately protects for substantial cooking in new California residences.

03 NATURAL GAS↗

Indoor air quality in new and renovated low-income apartments with mechanical ventilation and natural gas cooking in California

This work presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ), formaldehyde and carbon dioxide (CO 2 ) and time-integrated formaldehyde, NO 2 and nitrogen oxides (NO X ). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM 2.5 , formaldehyde, NO 2 , and CO 2 were 7.7 µg/m 3 , 14.1 ppb, 18.8 ppb, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM 2.5 above the California annual outdoor standard of 12 µg/m 3 and also discrete days above the World Health Organization 24-h guideline of 25 µg/m 3 . Two apartments had weekly NO 2 above the California annual outdoor standard of 30 ppb.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured indoor PM2.5, black carbon, and oxidative potential before and after replacing gas with induction cooking in asthmatic households

Cooking is a major source of fine particulate matter (PM) in homes and evidence to date is inconclusive about the impact of cooking fuel on measures of residential PM exposure. The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality (IAQ) and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. Intensive measurements occurred over three 2-week intensive periods: at baseline and at the end of two consecutive 3-month study phases. Participants were randomly assigned to have their gas stoves replaced with electric induction at the start of Phase 1 or Phase 2. As part of the IAQ assessment, we collected particulate matter on Teflon filters using ultrasonic personal air samplers (UPAS). The filters were analyzed to quantify time-integrated PM 2.5 mass concentration, black carbon (BC) oxidative potential (OP). OP was measured using the SLF-OH assay, an acellular chemical assay that quantifies production of OH radicals in simulated lung fluid (SLF). Across all comparisons, PM 2.5 mass tended to be higher during gas cooking than induction electric cooking, although only one transition (Baseline to Phase 1) was statistically discernible at p<0.05. BC and mass-normalized OP showed no measurable differences across stove types or across phases. These preliminary findings suggest that stove fuel alone may not be the dominant determinant of indoor PM 2.5 concentrations in this sample, as previous studies have reported that indoor PM 2.5 during cooking can also be influenced by factors such as cooking practices, food and oil type, kitchen ventilation, and outdoor infiltration.

Lin, Zhuoying↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooking methods and kitchen ventilation availability, usage, perceived performance and potential in Canadian homes

Cooking is a substantial contributor to air pollutant exposures in many residences. Effective use of kitchen ventilation can mitigate exposure; however, information on its availability, usage, and potential to increase its use across the population has been limited. This study aimed to obtain nationally representative information on cooking methods, kitchen ventilation availability and usage, and the potential for education to increase effective usage. An online survey was sent to a representative sample of Canadian homes to collect data on cooking methods, the presence and use of mechanical kitchen ventilation devices, perceived device performance, and willingness to implement mitigation strategies. Responses were weighted to match key demographic factors and analyzed using non-parametric statistics. Among the 4500 respondents, 90% had mechanical ventilation devices over the cooktop (66% of which were vented to the outside), and 30% reported regularly using their devices. Devices were used most often for deep-frying, followed by stir-frying, sautéing or pan-frying, indoor grilling, boiling or steaming. Almost half reported rarely or never using their ventilation devices during baking or oven self-cleaning. Only 10% were fully satisfied with their devices. More frequent use was associated with the device being vented to the outdoors, having more than two speed settings, quiet operation if only one speed, covering over half of the cooktop, and higher perceived effectiveness. After being informed of the benefits of kitchen ventilation, 64% indicated they would consider using their devices more often, preferentially using back burners with ventilation, and/or using higher ventilation device settings when needed. This study provides population-representative data on the most used cooking methods, kitchen ventilation availability and usage, and influencing factors in Canadian homes. Such data are needed for exposure assessments and evaluating the potential to mitigate cooking-related pollutant exposures via more effective use of kitchen ventilation. The data can be reasonably extrapolated to the United States, given the similarities in residential construction practices and cultural norms between the two countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Internal Performance of a Fixed-Shroud Nonaxisymmetric Nozzle Equipped with an Aft-Hood Exhaust Deflector

An investigation was conducted in the model preparation area of the Langley 16-Foot Transonic Tunnel to determine the internal performance of a fixed-shroud nonaxisymmetric nozzle equipped with an aft-hood exhaust deflector. Model geometric parameters investigated included nozzle power setting, aft-hood deflector angle, throat area control with the aft-hood deflector deployed, and yaw vector angle. Results indicate that cruise configurations produced peak performance in the range consistent with previous investigations of nonaxisymmetric convergent-divergent nozzles. The aft-hood deflector produced resultant pitch vector angles that were always less than the geometric aft-hood deflector angle when the nozzle throat was positioned upstream of the deflector exit. Significant losses in resultant thrust ratio occurred when the aft-hood deflector was deployed with an upstream throat location. At each aft-hood deflector angle, repositioning the throat to the deflector exit improved pitch vectoring performance and, in some cases, substantially improved resultant thrust ratio performance. Transferring the throat to the deflector exit allowed the flow to be turned upstream of the throat at subsonic Mach numbers, thereby eliminating losses associated with turning supersonic flow. Internal throat panel deflections were largely unsuccessful in generating yaw vectoring.

Asbury, Scott C.↗

Tests of an NACA 66,2-420 Airfoil of 5-Foot Chord at High Speed, Special Report

This report covers tests of a 5-foot model of the NACA 66,2-420 low-drag airfoil at high speeds including the critical compressibility speed. Section coefficients of lift, drag, and pitching moment, and extensive pressure-distribution data are presented. The section drag coefficient at the design lift coefficient of 0.4 increased from 0.0042 at low speeds to 0.0052 at a Mach number of 0.56 (390 mph at 25,000 ft altitude). The critical Mach number was about 0.60. The results cover a Reynold number range from 4 millions to 17 millions.

Hood, Manley J.↗

The Effect of Surface Irregularities on Wing Drag: Roughness - 3

Tests have been made in the N.A.C.A. 8-foot high-speed wind tunnel of the drag caused by roughness on the surface of an airfoil of N.A.C.A. 23012 section and 5-foot chord. The tests were made at speeds from 80 t o 500 miles per hour at lift coefficients from 0 to 0.30. For conditions corresponding to high-speed flight, the increase in the drag was 30 percent of the profile drag of the smooth airfoil for the roughness produced by spray painting and 63 percent for the roughness produced. by 0.0037-inch carborundum grains. About one-half the drag increase was caused by the roughness on the forward one-fourth of the airfoil. Sandpapering the painted surface with No. 400 sandpaper made it sufficiently smooth that the drag was no greater than when the surface was polished. In the lower part of the range investigated the drag due to roughness increased rapidly with Reynolds Number.

Hood, Manley J.↗

Characterization of the Superconducting Microwave Properties of Aluminum Manganese

A microwave kinetic inductance detector (MKID) is a superconducting pair breaking detector that offers a number of unique advantages for realizing large-format arrays of ultra-sensitive detectors, such as inherent multiplexibility and relative ease of fabrication. With the detection threshold being set by the Cooper pair binding energy, and correspondingly, the superconducting critical temperature (T c ), typically well-understood MKID materials such as aluminum (Al) present a lower limit on the operating frequency. Aluminum manganese (Al-Mn) is a promising candidate material for MKIDs because it can be fabricated with nearly identical processing as pure Al, but allows for control of the T c , with varying levels of Mn doping or post-deposition heat treatment. In this study, we present initial results from an early characterization of AlMn using a series of lumped-element superconducting microwave resonators, including measurements of T c , internal quality factor, and noise performance over a range of Mn doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Immersive cyberspace system

An immersive cyberspace system is presented which provides visual, audible, and vibrational inputs to a subject remaining in neutral immersion, and also provides for subject control input. The immersive cyberspace system includes a relaxation chair and a neutral immersion display hood. The relaxation chair supports a subject positioned thereupon, and places the subject in position which merges a neutral body position, the position a body naturally assumes in zero gravity, with a savasana yoga position. The display hood, which covers the subject's head, is configured to produce light images and sounds. An image projection subsystem provides either external or internal image projection. The display hood includes a projection screen moveably attached to an opaque shroud. A motion base supports the relaxation chair and produces vibrational inputs over a range of about 0-30 Hz. The motion base also produces limited translation and rotational movements of the relaxation chair. These limited translational and rotational movements, when properly coordinated with visual stimuli, constitute motion cues which create sensations of pitch, yaw, and roll movements. Vibration transducers produce vibrational inputs from about 20 Hz to about 150 Hz. An external computer, coupled to various components of the immersive cyberspace system, executes a software program and creates the cyberspace environment. One or more neutral hand posture controllers may be coupled to the external computer system and used to control various aspects of the cyberspace environment, or to enter data during the cyberspace experience.

Park, Brian V.↗