At least 19 records

Modeling Value Flows in Utility Rate Structures

As the increased adoption of distributed energy resources continues to challenge flat utility rate structures, time-varying rates and more dynamic mechanisms like transactive energy systems can better leverage customer-sited distributed energy resources to provide grid services. However, adopting new utility policies can be a timely process and requires a high level of transparency into the energy system. A wide range of stakeholders must understand who may be affected by policy changes and how. This work employs the valuation methodology developed under Pacific Northwest National Laboratory’s Transactive Systems Program to outline the functional differences in value flow under a series of conventional rate structures and a transactive energy system. The resulting value model illustrates the nuances that arise and highlights future avenues of work that will be necessary as utilities across the country continue to develop new rate structures and market mechanisms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Residential Time-of-Use Utility Rate Structures and Economic Implications for Thermal Energy Storage

Thermal energy storage (TES) is an increasingly popular tool to level out the daily electrical demand and add stability to the electrical grid as more intermittent renewable energy sources are installed. TES systems can locally decouple high thermal loads from the operation of a heat pump or reduce the electrical energy demand of the heat pump by providing a more favorable temperature gradient. In addition, many policy makers and utility providers have introduced time-of-use (TOU) rate schedules for residential customers to better reflect the price of electricity generation and demand for specific times. TOU rate schedules price grid-provided electricity differently throughout the day depending on the region’s climate, time of year, and electrical production. Large differences between on-peak and off-peak electrical prices may create an economic advantage for a residential customer to install a TES system. In this work, the economic and energy savings are calculated for a modeled 2,400 square foot residential building with water/ice-based TES using a TOU rate structure. The weather data is from Fresno County, CA, ASHRAE climate zone 3B, and a representative residential TOU utility rate structure from Pacific Gas and Electric (PG&E) was used. The results showed that total energy consumption could be reduced by 14.5% with an 87.5% reduction in on-peak energy usage when the TES is installed. The cost of operating this system for space cooling was reduced by nearly 20% using the sample utility rate plan.

Sultan, Sara↗

Policy and Cost Allocation Considerations for Large Electric Load Interconnections: Emerging Policy Trends in Rate Structures, Interconnection, and Cost Impacts on Other System Users

Load growth in the United States is rapidly increasing: load from data centers alone has tripled over the past decade, and this growth is forecasted to continue accelerating. These and other large electric loads (LELs) promise economic benefits at the state and local level, but their deployment has also led to increasing concerns about grid impacts and potential cost shifts onto other ratepayers. Legislators, regulators, and other stakeholders are increasingly proposing and enacting policies in effort to balance these and other considerations. This white paper reviews state-level legislation, selected utility rate cases, and relevant federal orders in an effort to describe and categorize relevant trends in policies related to LEL cost allocation, interconnection, and deployment. Policy categories identified through this review include tax incentives, rate actions, and requirements related to interconnection, permitting, and reporting. By offering a taxonomy of policies, this white paper aims to offer a resource to policymakers and other stakeholders navigating this transformative moment for the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EFFORT (EFFectiveness Of Rate sTructure for enabling demand response)

This tool helps utilities evaluate potential time of use price-plans and find effective hours for price plan on peak periods and the potential price-elastic demand response. An optimization model can be used to find tiered prices for the time of use tariffs and analyze the impact on load profiles, energy consumption, utility, and customer savings. The tool is equipped with an optimization model to determine the energy consumption of electric appliances that can leverage survey data containing information on the number of appliances owned by customers. Lastly, a statistical model can be used to predict system-level load based on exogenous parameters such as weather, time of day, month, type of day, and year. The tool is scripted in Python and uses the Pyomo python optimization language.

Duwadi, Kapil↗

Comparison of the Energy-Transfer Rates in Structural and Spectral Variants of the B800–850 Complex from Purple Bacteria

Photosynthetic light harvesting can occur with a remarkable near-unity quantum efficiency. The B800–850 complex, also known as light-harvesting complex 2 (LH2), is the primary light-harvesting complex in purple bacteria and has been extensively studied as a model system. The bacteriochlorophylls of the B800–850 complex are organized into two concentric rings, known as the B800 and B850 rings. However, depending on the species and growth conditions, the number of constituent subunits, the pigment geometry, and the absorption energies vary. While the dynamics of some B800–850 variants have been exhaustively characterized, others have not been measured. Furthermore, a direct and simultaneous comparison of how both structural and spectral differences between variants affect these dynamics has not been performed. In this work, we utilize ultrafast transient absorption measurements to compare the B800 to B850 energy-transfer rates in the B800–850 complex as a function of the number of subunits, geometry, and absorption energies. The nonameric B800–850 complex from Rhodobacter (Rb.) sphaeroides is 40% faster than the octameric B800–850 complex from Rhodospirillum (Rs.) molischianum, consistent with structure-based predictions. In contrast, the blue-shifted B800–820 complex from Rs. molischianum is only 20% faster than the B800–850 complex from Rs. molischianum despite an increase in the spectral overlap between the rings that would be expected to produce a larger increase in the energy-transfer rate. These measurements support current models that contain dark, higher-lying excitonic states to bridge the energy gap between rings, thereby maintaining similar energy-transfer dynamics. Altogether, these results demonstrate that energy-transfer dynamics in the B800–850 complex are robust to the spectral and structural variations between species used to optimize energy capture and flow in purple bacteria.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dataset For: A Guide to Residential Energy Storage and Rooftop Solar: State Net Metering Policies and Utility Rate Tariff Structures

Federal and state decarbonization goals have led to numerous financial incentives and policies designed to increase access and adoption of renewable energy systems. In combination with the declining cost of both solar photovoltaic and battery energy storage systems and rising electric utility rates, residential renewable adoption has become more favorable than ever. However, not all states provide the same opportunity for cost recovery, and the complicated and changing policy and utility landscape can make it difficult for households to make an informed decision on whether to install a renewable system. This paper is intended to provide a guide to households considering renewable adoption by introducing relevant factors that influence renewable system performance and payback, summarized in a state lookup table for quick reference. Five states are chosen as case studies to perform economic optimizations based on net metering policy, utility rate structure, and average electric utility price; these states are selected to be representative of the possible combinations of factors to aid in the decision-making process for customers in all states. The results of this analysis highlight the dual importance of both state support for renewables and price signals, as the benefits of residential renewable systems are best realized in states with net metering policies facing the challenge of above-average electric utility rates. This dataset is intended to allow readers to reproduce and customize the analysis performed in this work to their benefit. Suggested modifications include: location, household load profile, rate tariff structure, and renewable energy system design.

14 SOLAR ENERGY↗

New fine structure cooling rate

One of the dominant electron cooling processes in the ionosphere is caused by electron impact induced fine structure transitions among the ground state levels of atomic oxygen. This fine structure cooling rate is based on theoretical cross sections. Recent advances in the numerical cross section determinations to include polarization effects and more accurate representations of the atomic target result in new lower values. These cross sections are employed in this paper to derive a new fine structure cooling rate which is between 40% and 60% of the currently used rate. A new generalized formula is presented for the cooling rate (from which the fine structure cooling rate is derived), valid for arbitrary mass and temperature difference of the colliding particles and arbitrary inelastic energy difference.

Hoegy, W. R.↗

New fine structure cooling rate

One of the dominant electron cooling processes in the ionosphere is caused by electron impact induced fine structure transitions among the ground state levels of atomic oxygen. This fine structure cooling rate is based on theoretical cross sections. Recent advances in the numerical cross section determinations to include polarization effects and more accurate representations of the atomic target result in new lower values. These cross sections are employed in this paper to derive a new fine structure cooling rate which is between 40% and 60% of the currently used rate. A new generalized formula is presented for the cooling rate (from which the fine structure cooling rate is derived), valid for arbitrary mass and temperature difference of the colliding particles and arbitrary inelastic energy difference.

Hoegy, W. R.↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Advancing Measurements and Understanding of the Rate and Structure of Atmospheric Warming

The rate and geographic pattern of atmospheric warming are key indicators of historical climate change and play a role in modulating future changes in Earth’s climate. The past and future evolution of atmospheric temperature is simulated using global climate models while observational estimates of past warming are derived from satellite microwave measurements. Individual climate models simulate widely varying rates of past and future atmospheric warming and most model simulations exhibit greater tropospheric (lowest ~10 km of atmosphere) temperature change than satellite observations between 1979 and 2020. This project examined intermodel differences in the pattern of atmospheric warming and how these differences influence climate feedbacks that can amplify or damp the rate of global surface warming. A key result is that climate model representation of the current climate can influence climate feedbacks and the simulation of future changes in climate. Another focus of this project was to analyze how models respond to different input datasets, such as volcanic aerosols or sea surface temperature (in atmosphere-only simulations). We find that different prescribed inputs can affect simulated changes in atmospheric temperature, even though “input uncertainty” is often unconsidered in model-observational comparisons. A final focus of this research project was to consider the influence of natural internal climate variability on satellite era changes in climate. Although the Earth is warming substantially due to anthropogenic emissions of greenhouse gases, the observed warming rate can be modulated by natural variations in the Earth’s climate. We find that natural climate variability has slowed the rate of tropical tropospheric warming, which explains model-satellite differences in the rate of tropospheric warming.

58 GEOSCIENCES↗

Structural Certification of Human-Rated Inflatable Space Structures

This paper details the results of an initial study to develop a certification plan for human-rated inflatable space structures, including guidelines for qualification testing. Habitable softgoods inflatables are multi-layered shell structures that use high-strength webbing, cordage and broadcloth fabric to carry the skin loads of a variety of volumetric shapes and structural architectures. The primary objectives of this study are to define the key parameters that affect these structures and propose a statistically robust approach to defining safety and knockdown factors based on test and analysis. Current NASA standards for habitable inflatable space structures use a factor of safety of 4, which was inherited from airship design criteria. An updated approach to defining a design factor, taking into account material strength variability, load variability in the article, number of test samples, and damage and degradation effects is specified. Accurate analytical modeling of these structures is hindered by the difficulty of obtaining accurate and consistent material data due to load-history- dependent, nonlinear load versus strain behavior. A building block approach to certification is detailed that uses stochastic modeling and statistical test design and analysis to address the unique challenges these high-strength softgoods structures present. Human-rated inflatable modules are a transformative capability for launching much larger habitable volumes into space than is possible with rigid shell structures. This research aims to provide the framework for certifying these structures for future human space exploration missions.

Jones, Thomas C.↗

Spokane Eco-District Campus Performance Under Alternative Electricity Rates: Benefits for virtual power plant participants and suppliers

Here, the respective benefits for virtual power plant participants and suppliers are revealed and compared under alternative electricity rate structures, including conventional large commercial electricity rates, large commercial electricity rates with special rates for demand-side generation, and dynamic hourly transactive prices. These three scenarios were explored using the capabilities of the Eco-District campus, a virtual power plant in Spokane, Washington, that is supplied electricity by Avista Utilities. The Eco-District Campus was modeled to host solar power generation, battery energy storage, and thermal energy resources that must be coordinated with building heating and cooling needs. First, the electricity supplier’s costs for energy, infrastructure, and energy losses were modeled. Then, the virtual power plant’s performance was modeled while presuming that its manager would minimize its costs under its electricity rate structure. The demand charges of conventional commercial electricity rates managed monthly peak, as would be expected, but hourly dynamic transactive pricing resulted in a striking alignment between the costs incurred by the supplier and the virtual power plant’s energy costs.

Electricity rates↗

Predicting initial dissolution rates using structural features from molecular dynamics simulations

Predicting chemical durability of glass materials is important for various applications from daily life such as drink glass and kitchen ware to advanced technologies such as nuclear waste disposal and biomedicine. In this work, we explored prediction of initial dissolution rate through structural features from molecular dynamics (MD) simulations for a wide range of glass compositions (total 28) including borosilicate and aluminosilicate glasses, ZrO 2 -containing and V 2 O 5 -containing boroaluminosilicate glasses. The initial dissolution rates (r 0 ) measured experimentally at 90 °C with varying solution conditions were correlated with structural features (e.g., polyhedral linkages and non-bridging oxygen species) obtained from MD simulations, either from this study or from literature. Since hydrolysis of the glass network through breaking of the network former linkages (e.g., Si-O-Si, Si-O-Al, etc.) is a critical step of network glass dissolution, the statistics of these linkages obtained from MD were correlated to r0 through linear regression, where the coefficient of determination (R 2 ) and root mean square error are found to be 0.949 and 0.681, respectively. This model was compared and discussed with existing models developed by various approaches including machine learning, the kinetic rate equation, topological constraint theory, and other descriptors from MD simulations. The discussion provides insights on future model improvements to predict glass dissolution. In addition, the impact of V 2 O 5 on the glass dissolution was examined in detail, implicating that the impact is not the same across all glass compositions and test conditions.

36 MATERIALS SCIENCE↗

Turbulence structure at high shear rate

The structure of homogeneous turbulence in the presence of a high shear rate is studied using results obtained from three-dimensional time-dependent numerical simulations of the Navier-Stokes equations on a grid of 512 x 128 x 128 node points. It is shown that high shear rate enhances the streamwise fluctuating motion to such an extent that a highly anisotropic turbulence state with a one-dimensional velocity field and two-dimensional small-scale turbulence develops asymptotically as total shear increases. Instantaneous velocity fields show that high shear rate in homogeneous turbulent shear flow produces structures which are similar to the streaks present in the viscous sublayer of turbulent boundary layers.

Lee, Moon Joo↗

Measurements of cosmic expansion and growth rate of structure from voids in the Sloan Digital Sky Survey between redshift 0.07 and 1.0

ABSTRACT We present measurements of the anisotropic cross-correlation of galaxies and cosmic voids in data from the Sloan Digital Sky Survey (SDSS) Main Galaxy Sample, Baryon Oscillation Spectroscopic Survey (BOSS), and extended BOSS luminous red galaxy catalogues from SDSS Data Releases 7, 12, and 16, covering the redshift range 0.07 < z < 1.0. As in our previous work analysing voids in subsets of these data, we use a reconstruction method applied to the galaxy data before void finding in order to remove selection biases when constructing the void samples. We report results of a joint fit to the multipole moments of the measured cross-correlation for the growth rate of structure, fσ8(z), and the ratio DM(z)/DH(z) of the comoving angular diameter distance to the Hubble distance, in six redshift bins. For DM/DH, we are able to achieve a significantly higher precision than that obtained from analyses of the baryon acoustic oscillations and galaxy clustering in the same data sets. Our growth rate measurements are of lower precision but still comparable with galaxy clustering results. For both quantities, the results agree well with the expectations for a Λ cold dark matter model. Assuming a flat Universe, our results correspond to a measurement of the matter density parameter $\Omega _\mathrm{m}=0.337^{+0.026}_{-0.029}$. For more general models, the degeneracy directions obtained are consistent with and complementary to those from other cosmological probes. These results consolidate void–galaxy cross-correlation measurements as a pillar of modern observational cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

The Completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: measurement of the BAO and growth rate of structure of the emission line galaxy sample from the anisotropic power spectrum between redshift 0.6 and 1.1

We analyse the large-scale clustering in Fourier space of emission line galaxies (ELG) from the Data Release 16 of the Sloan Digital Sky Survey IV extended Baryon Oscillation Spectroscopic Survey. The ELG sample contains 173,736 galaxies covering 1,170 square degrees in the redshift range 0.6 < z < 1.1. We perform a BAO measurement from the post-reconstruction power spectrum monopole, and study redshift space distortions (RSD) in the first three even multipoles. Furthermore, photometric variations yield fluctuations of both the angular and radial survey selection functions. Those are directly inferred from data, imposing integral constraints which we model consistently. The full data set has only a weak preference for a BAO feature (1.4σ). At the effective redshift zeff = 0.845 we measure $D_{\rm V}(z_{\rm eff})/r_{\rm drag} = 18.33_{-0.62}^{+0.57}$, with DV the volume-averaged distance and rdrag the comoving sound horizon at the drag epoch. In combination with the RSD measurement, at zeff = 0.85 we find $f\sigma _8(z_{\rm eff}) = 0.289_{-0.096}^{+0.085}$, with f the growth rate of structure and σ8 the normalisation of the linear power spectrum, $D_{\rm H}(z_{\rm eff})/r_{\rm drag} = 20.0_{-2.2}^{+2.4}$ and DM(zeff)/rdrag = 19.17 ± 0.99 with DH and DM the Hubble and comoving angular distances, respectively. These results are in agreement with those obtained in configuration space, thus allowing a consensus measurement of fσ8(zeff) = 0.315 ± 0.095, $D_{\rm H}(z_{\rm eff})/r_{\rm drag} = 19.6_{-2.1}^{+2.2}$ and DM(zeff)/rdrag = 19.5 ± 1.0. This measurement is consistent with a flat ΛCDM model with Planck parameters.

79 ASTRONOMY AND ASTROPHYSICS↗