Search NASA⌕ Search

SEARCH · Search NASA

Results for “rate-determining step”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Homogeneous reactions of hydrocarbons, silane, and chlorosilanes in radiofrequency plasmas at low pressures

The ion-molecule and radical-molecule mechanisms are responsible for the dissociation of hydrocarbon, silane, and chlorosilane monomers and the formation of polymerized species, respectively, in an RF plasma discharge. In a plasma containing a mixture of monomer and argon the rate-determining step for both dissociation and polymerization is governed by an ion-molecule type of interaction. Adding hydrogen or ammonia to the monomer-argon mixture transforms the rate-determining step from an ion-molecule interaction to a radical-molecule interaction for both monomer dissociation and polymerization.

Avni, R.↗

Trace contaminant adsorption and sorbent regeneration in closed ecological systems

Correlation was obtained for determining sorptive capacity of carbon for pure and mixed contaminants under dry and humid conditions at various temperatures. Vacuum desorption rates were investigated for single particles and for sorbent beds. For sorbent beds, rate-determining step is Knudsen diffusion through interparticle voids.

Arnold, C. R.↗

Mechanism of the oxidation of titanium disilicide.

Study of the oxidation of TiSi2 at temperatures of 300 to 1300 C. Wafers prepared using the techniques of powder metallurgy had densities of 95 to 98% of the theoretical value. On oxidation at temperatures up to 600 C, the polished wafers formed a protective, titania-silica glass. The rate data indicate a complex surface and diffusion-limited mechanism. Above 600 deg C, the oxide consisted of an amorphous SiO2 film with crystalline islands of TiO2 (rutile). From 1000 to 1300 C, parabolic kinetics with an activation energy of 21.3 kcal/mole were observed. These data are consistent with a model in which the rate-determining step is the diffusion of oxygen through the silica film with the simultaneous diffusion of titanium from the substrate to the islands of rutile growing on top of the amorphous silica.

Schwettmann, F. N.↗

Electrode kinetics of oxygen reduction - A theoretical and experimental analysis of the rotating ring-disc electrode method

In order to calculate most of the rate constants for the intermediate formation of H2O2 in the electroreduction of O2 to H2O, the theoretical treatments of the rotating ring-disc electrode method by Damjanovic et al. (1966, 1967), Bagotskii et al. (1968, 1969), and Wroblowa et al. (1976) are modified. Rotating ring-disc electrode experimental data obtained for O2 reduction in Pt in 0.55 M H2SO4 are used to illustrate the calculations of rate constants according to the above theoretical treatments. A simple reaction model as proposed by the first author is consistent with the experimental data. The results indicate that O2 (97 percent) reduces to H2O in a direct four-electron transfer reaction. The adsorption of O2 is probably the rate-determining step in the potential region more negative than 0.5 V vs. reversible hydrogen electrode.

Hsueh, K.-L.↗

Adsorption and solvation of ethanol at the water liquid-vapor interface: a molecular dynamics study

The free energy profiles of methanol and ethanol at the water liquid-vapor interface at 310K were calculated using molecular dynamics computer simulations. Both alcohols exhibit a pronounced free energy minimum at the interface and, therefore, have positive adsorption at this interface. The surface excess was computed from the Gibbs adsorption isotherm and was found to be in good agreement with experimental results. Neither compound exhibits a free energy barrier between the bulk and the surface adsorbed state. Scattering calculations of ethanol molecules from a gas phase thermal distribution indicate that the mass accommodation coefficient is 0.98, and the molecules become thermalized within 10 ps of striking the interface. It was determined that the formation of the solvation structure around the ethanol molecule at the interface is not the rate-determining step in its uptake into water droplets. The motion of an ethanol molecule in a water lamella was followed for 30 ns. The time evolution of the probability distribution of finding an ethanol molecule that was initially located at the interface is very well described by the diffusion equation on the free energy surface.

NASA Discipline Exobiology↗

Carbon isotope effects associated with aceticlastic methanogenesis

The carbon isotope effects associated with synthesis of methane from acetate have been determined for Methanosarcina barkeri 227 and for methanogenic archaea in sediments of Wintergreen Lake, Michigan. At 37 degrees C, the 13C isotope effect for the reaction acetate (methyl carbon) --> methane, as measured in replicate experiments with M. barkeri, was - 21.3% +/- 0.3%. The isotope effect at the carboxyl portion of acetate was essentially equal, indicating participation of both positions in the rate-determining step, as expected for reactions catalyzed by carbon monoxide dehydrogenase. A similar isotope effect, - 19.2% +/- 0.3% was found for this reaction in the natural community (temperature = 20 degrees C). Given these observations, it has been possible to model the flow of carbon to methane within lake sediment communities and to account for carbon isotope compositions of evolving methane. Extension of the model allows interpretation of seasonal fluctuations in 13C contents of methane in other systems.

NASA Discipline Exobiology↗

New Gas Polarographic Hydrogen Sensor

Polarography is the measurement of the current that flows in solution as a function of an applied voltage. The actual form of the observed polarographic current depends upon the manner in which the voltage is applied and on the characteristics of the working electrode. The new gas polarographic H2 sensor shows a current level increment with concentration of the gaseous H2 similar to those relating to metal ions in liquid electrolytes in well-known polarography. This phenomenon is caused by the fact that the diffusion of the gaseous H2 through a gas diffusion hole built in the sensor is a rate-determining step in the gaseous-hydrogen sensing mechanism. The diffusion hole artificially limits the diffusion of the gaseous H2 toward the electrode located at the sensor cavity. This gas polarographic H2 sensor. is actually an electrochemical-pumping cell since the gaseous H2 is in fact pumped via the electrochemical driving force generated between the electrodes. Gaseous H2 enters the diffusion hole and reaches the first electrode (anode) located in the sensor cavity to be transformed into an H+ ions or protons; H+ ions pass through the electrolyte and reach the second electrode (cathode) to be reformed to gaseous H2. Gas polarographic 02 sensors are commercially available; a gas polarographic 02 sensor was used to prove the feasibility of building a new gas polarographic H2 sensor.

Dominguez, Jesus A.↗

H2 Detection via Polarography

Polarography is the measurement of the current that flows in solution as a function of an applied voltage. The actual form of the observed polarographic current depends upon the manner in which the voltage is applied and on the characteristics of the working electrode. The new gas polarographic H2 sensor shows a current level increment with concentration of the gaseous H2 similar to those relating to metal ions in liquid electrolytes in well-known polarography. This phenomenon is caused by the fact that the diffusion of the gaseous H2 through a gas diffusion hole built in the sensor is a rate-determining step in the gaseous-hydrogen sensing mechanism. The diffusion hole artificially limits the diffusion of the gaseous H2 toward the electrode located at the sensor cavity. This gas polarographic H2 sensor is actually an electrochemical-pumping cell since the gaseous H2 is in fact pumped via the electrochemical driving force generated between the electrodes. Gaseous H2 enters the diffusion hole and reaches the first electrode (anode) located in the sensor cavity to be transformed into an H ions or protons; H ions pass through the electrolyte and reach the second electrode (cathode) to be reformed to gaseous H2. Gas polarographic O2 sensors are commercially available; a gas polarographic O2 sensor was used to prove the feasibility of building a new gas polarographic H2 sensor.

Dominquez, Jesus↗

Reversible Colorimetric Sensing of Volatile Analytes By Wicking in Close Proximity to A Photonic Film

Isolation of volatile analytes from environmental or biological fluids is a rate-determining step that can delay the response time for continuous sensing. In this paper, we demonstrate a colorimetric sensing system that enables the rapid detection of gas-phase analytes released from a flowing micro-volume fluid sample. The sensor platform is an analyte-responsive metal-insulator-metal (MIM) thin-film structure integrated with a large area quartz micropillar array. This allows precise planar alignment and microscale separation (310 μm) of the optical and fluidic structures. This configuration offers rapid and homogeneous color changes over large areas that permits detection by low-resolution optics or eye, which is well-suited to portable/wearable devices. For our proof-of-principle demonstration, we utilized a poly(methyl methacrylate) (PMMA) spacer and evaluated the sensor's response (color change) to ethanol vapor. We show that the RGB color value is quantitatively linked to the spacer swelling, which is reversible and repeatable. The optofluidic platform reduces the sensor response time from minutes to seconds compared with experiments using a conventional chamber. The sensor's concentration-dependent response was examined, confirming the potential of the reported sensing platform for continuous, compact, and quantitative colorimetric analysis of volatile analytes in low-volume samples, such as biofluids.

Timothy J. Palinski↗

The reduction of chlorine on carbon in AlCl3-KCl-NaCl melts

Using a rotating vitreous carbon disk electrode, the kinetic parameters for chlorine reduction in an AlCl3-KCl-NaCl (57.5-12.5-30 mol percent) melt were determined. It was found that the reduction of chlorine occurs according to two paths, with the first step probably being rate-determining.

Holleck, G. L.↗