Search NASA⌕ Search

SEARCH · Search NASA

Results for “reactive power control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Decoupled Active and Reactive Power Control without PLL Requirement for Differential Buck Converter

This paper presents a decoupled active and reactive power control for the differential buck converter. This control does not require phase locked loop (PLL) for synchronization. Also, it achieves active and reactive power control in a simple single control loop structure. The differential buck converter has the capability to compensate the double line frequency power ripple without relying on additional hardware. Particularly, the Common Mode (CM) operation is used for active double line frequency power ripple absorption. Whereas, the Differential Mode (DM) operation is used as an active and reactive power exchanging port between the converter and the grid at the point of common coupling (PCC). The motivation behind this paper proposal are: (i) to avoid PLL induced instabilities, especially, when connecting the differential buck converter with weak grid, and (ii) direct active and reactive power control for the differential buck in a single loop control. The theoretical analyses are verified with a 5 kW converter with only 50 μF decoupling capacitor connected to a weak grid.

Khan, Ahmad↗

Single Stage PLL-less Decoupled Active and Reactive Power Control for Weak Grid Interactive Inverters

This paper presents a single stage phase locked loop-less (PLL-less) active and reactive power (PQ) control for single-phase weak grid interactive inverters. The absence of the PLL requirement in the proposed PQ control enhances the stability margin comparing to conventional current control approaches in both the stationary or the synchronous reference frame. Additionally, the proposed control scheme enables direct PQ control with a single loop control structure. This paper demonstrates that the proposed PLL-less PQ control scheme is asymptotically stable if the controller gains are positive. The necessary conditions for supplying the rated active power into the weak grid are derived. The provided analysis shows that certain amount of reactive power injection is necessary to avoid point of common coupling (PCC) voltage collapse when the rated active power is injected into the weak grid. Several case studies are provided to demonstrate the performance of the proposed PLL-less PQ control scheme under weak grid condition.

Khan, Ahmad↗

Reactive Power Control Methods for Islanded Operation

As feeder-level microgrid controls begin to incorporate multiple GFM DER and voltage regulation equipment, island reactive power dispatch strategies can be improved. Although Volt-Var Optimization (VVO) control is typical in an Advanced Distribution Management System (ADMS), most microgrid controllers do not apply VVO during island operations. This report investigates reactive power control strategies for feeder-level microgrid operations. It also proposes evaluation metrics that can be applied to analyze the performance improvements of the new microgrid control strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Overview of Issues Related to IEEE Std 1547-2018 Requirements Regarding Voltage and Reactive Power Control

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547 Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces (IEEE Std 1547-2018) was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concept and requires the appropriate information required to calculate relevant settings and configurations. Various stakeholders have different roles in implementing the standard, and portions of the standard are directed toward a specific audience who must possess specialized information and technical training to use and apply the requirements. This document aims to (1) summarize a specific portion of the standard as concisely as possible and (2) provide the reader with introductory knowledge and information to support the utilization of the requirements.

14 SOLAR ENERGY↗

Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗

Voltage Support With PV Inverters in Low-Voltage Distribution Networks: An Overview

Large solar photovoltaic (PV) penetration using inverters in low voltage (LV) distribution networks may pose several challenges, such as reverse power flow and voltage rise situations. These challenges will eventually force grid operators to carry out grid reinforcement to ensure continued safe and reliable operations. However, smart inverters with reactive power control capability enable PV systems to support voltage quality in the distribution network better. Here, this paper gives an overview of the current state-of-the-art control strategies for handling voltage problems through PV inverters and other devices. In addition, the (control) technical issues of PV systems integrated into the LV distribution network are considered from a control point of view. By comparing the control issues of PV integration into the grid, the paper aims to help distribution system operators to expand the volume of PV generation in the distribution system in an efficient and safe manner. Additionally, it will help control engineers and researchers select proper control strategies for PV systems as well as other distributed renewable sources.

42 ENGINEERING↗

Control system design for the MOD-5A 7.3 mW wind turbine generator

This paper provides descriptions of the requirements analysis, hardware development and software development phases of the Control System design for the MOD-5A 7.3 mW Wind Turbine Generator. The system, designed by General Electric Company, Advanced Energy Programs Department, under contract DEN 3-153 with NASA Lewis Research Center and DOE, provides real time regulation of rotor speed by control of both generator torque and rotor torque. A variable speed generator system is used to provide both airgap torque control and reactive power control. The wind rotor is designed with segmented ailerons which are positioned to control blade torque. The central component of the control system, selected early in the design process, is a programmable controller used for sequencing, alarm monitoring, communication, and real time control. Development of requirements for use of aileron controlled blades and a variable speed generator required an analytical simulation that combined drivetrain, tower and blade elastic modes with wind disturbances and control behavior. An orderly two phase plan was used for controller software development. A microcomputer based turbine simulator was used to facilitate hardware and software integration and test.

Barton, Robert S.↗

Model Predictive Voltage Control of Large-Scale PV or Hybrid PV-BESS Plants

Increased penetration level of inverter-based resources (IBRs) and renewable energy in the power grid has called for more requirements from the control of IBRs. In this paper, the voltage-reactive power control of a photovoltaic (PV) power plant or hybrid PV-battery energy storage system (BESS) plant connected to a bulk power grid, whilst meeting the grid requirements, is studied. In this paper, a continuous-set model predictive control (MPC) formulation is proposed for voltage-reactive power control. For the same, an aggregated dynamic PV plant model is developed based on the recursive system equivalencing method. The formulation is then implemented in PSCAD simulation on a 125 MW PV plant or hybrid PV-BESS plant. The MPC implementation achieves 10.13% voltage improvement based on PSCAD simulation results in a balanced fault case study. Simulation results further demonstrate that MPC provides improved voltage support over the conventional proportional-integral (PI) controller post-fault occurrence.

Abu rub, Omar↗

Coordinated voltage control and reactive power regulation between transmission and distribution systems

Systems and methods are described for coordinating volt-var control between sub-transmission and distribution systems. Distributed energy resources of a distribution system are aggregated into virtual power plants from which reactive power can optimally be dispatched to the sub-transmission system. A sub-transmission controller executes a volt-var AC optimal power flow optimisation function to minimize voltage fluctuations that might otherwise occur when coordinating with a distribution system having distributed energy resources. The distribution system can use a sensitivity matrix for regulating voltage at distribution feeders while fulfilling a transmission or sub-transmission system's demand requests.

Samaan, Nader A.↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variable speed generator application on the MOD-5A 7.3 mW wind turbine generator

This paper describes the application of a Scherbiustat type variable speed subsystem in the MOD-5A Wind Turbine Generator. As designed by General Electric Company, Advanced Energy Programs Department, under contract DEN3-153 with NASA Lewis Research Center and DOE, the MOD-5A utilizes the subsystem for both starting assistance in a motoring mode and generation in a controlled airgap torque mode. Reactive power control is also provided. The Scherbiustat type arrangement of a wound rotor machine with a cycloconverter in the rotor circuit was selected after an evaluation of variable speed technologies that followed a system evaluation of drivetrain cost and risk. The paper describes the evaluation factors considered, the results of the evaluations and summarizes operating strategy and performance simulations.

Barton, Robert S.↗

Simple and Robust Carrier-Based PWM Technique for Single-Stage Three-phase Rectifier Indirect Matrix Converter

Indirect matrix converters (IMC) can offer high efficiency, high power density, and bidirectional power flow capability with a single-stage three-to single-phase AC-AC power conversion integrating a conventional three-phase active rectifier with a primary side full-bridge inverter of a dual active bridge converter. However, the IMCs generally require space vector modulation techniques, leading to complex sectors and dwell times calculations. A practical implementation of the modulation methods with a commonly used digital signal processor becomes even more challenging when considering power factor correction, harmonics reduction, and deadtime between sector transitions. This paper proposes a simple and robust carrier-based pulse width modulation (PWM) technique determined through a voltage-source inverter (VSI) to current-source inverter (CSI) to IMC conversion. This translation enables the adoption of all conventional VSI control methods with active and reactive power control in the IMCs through simple carrier and reference waveform comparison. The VSI vectors are first one-on-one matched with CSI vectors and translated to IMC modulation signals without calculating sectors and dwell times. Nine different carrier waveforms are proposed, and the converter performance is analyzed. Grid current THD and efficiency are estimated for each modulation method. The symmetric A and B methods had the lowest THD of the grid current, 2.80%, and the efficiency remained at approximately 98.3%, making it the most suitable carrier-based method proposed in this paper. The space vector PWM (SVPWM) modulation method was implemented to the DSP and generated the expected twelve gate signals.

Benson, Mikayla↗

Control, Operation, and Stability Characteristics of Grid-Forming Type III Wind Turbines: Preprint

This paper explores the control, operation, and stability characteristics of grid-forming Type III wind turbines. The paper shows that the grid-forming operation mode requires redesign of only the slower control loops for active and reactive power control, whereas the faster current control implementation can stay the same as grid-following turbines. The paper also shows that grid-forming wind turbines face higher mechanical stress than grid-following wind turbines because of the slower speed of the active power control. This stress, however, can be mitigated using advanced pitch control. The paper compares the stability characteristics of the grid-forming and grid-following operation modes of Type III turbines by comparing sequence impedance responses for both operation modes. It is found that, unlike standard Type III wind turbines, the grid-forming mode substantially reduces the risks of subsynchronous oscillations during operation with series-compensated transmission lines. Moreover, the grid-forming Type III turbines can operate stably with extremely weak grids. The findings of this paper are validated using EMT-PSCAD simulations of a 2.5-MW turbine operating in both grid-forming and grid-following modes.

49 EE - Wind and Water Power Program - Wind (EE-4W↗