Search NASA⌕ Search

SEARCH · Search NASA

Results for “readout systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An application specific integrated circuit based multi-anode microchannel array readout system

Size reduction of two new multi-anode microchannel array (MAMA) readout systems is described. The systems are based on two analog and one digital application specific integrated circuits (ASICs). The new readout systems reduce volume over previous discrete designs by 80 percent while improving electrical performance on virtually every significant parameter. Emphasis is made on the packaging used to achieve the volume reduction. Surface mount technology (SMT) is combined with modular construction for the analog portion of the readout. SMT reliability concerns and the board area impact of MIL SPEC SMT components is addressed. Package selection for the analog ASIC is discussed. Future sytems will require even denser packaging and the volume reduction progression is shown.

Smeins, Larry G.↗

Electronic readout systems for microchannel plates

The modes of operation of position-sensitive electronic readout systems which use high-gain microchannel plate (MCP) electron multipliers are described, and their performance characteristics, along with those of the MCP, are compared. Among the structures presented are the wedge-and-strip, Codacon, and multilayer coincidence-anode MAMA (Multimode Microchannel Array) arrays. Spatial resolution of 25 x 25 sq microns (coincidence anode arrays) is achieved with an array format of 256 x 1024 pixels. On the basis of the performance data it is concluded that the readout systems using only conducting electrodes offer the best performance characteristics.

Timothy, J. G.↗

Operational characteristics of Wedge and Strip image readout systems

Application of the Wedge and Strip readout system in microchannel plate detectors for the Extreme Ultraviolet Explorer and FAUST space astronomy programs is discussed. Anode designs with high resolution (greater than 600 x 600 pixels) in imaging and spectroscopy applications have been developed. Extension of these designs to larger formats (100 mm) with higher resolution (3000 x 3000 pixels) are considered. It is shown that the resolution and imaging are highly stable, and that the flat field performance is essentially limited by photon statistics. Very high speed event response has also been achieved with output pulses having durations of less than 10 nanoseconds.

Siegmund, O. H. W.↗

Flow angle sensor and readout system

Sensor determines fluid flow angles by means of a simple vane that positions itself in the direction of the flow. The vane rotates a small light-reflecting disc as it moves while the readout system uses two cyclically polarized light beams.

Hansen, I. G.↗

Numerical data frame readout system used in testing telemetry systems

Digital telemetry systems are treated by a display system that offers direct readout as high data rates. The rates appear in numerical format and are adaptable to photographic recording techniques. The system can show bit dropouts at a memory output or locate a malfunction in a system.

Cote, C. E.↗

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

Evaluation of some wide dynamic range readout systems for photoelectric integrating spectrometers

Five types of electronic circuits commonly used for readout of currents from photomultiplier tubes were evaluated. This evaluation was conducted to define the experimental limits of achieving the widest possible dynamic range of light detection and concentration measurements in spectrochemical analysis. The circuits evaluated included the photon-counting technique and four dc circuits. These circuits displayed a dynamic range from 3 to about 4.5 decades within a repeatability criterion of 1 percent, or better. The maximum dynamic range allowed by the photomultiplier tube in this application was estimated to be about 6 decades.

Franklin, M. L.↗

An Efficient, FPGA-Based, Cluster Detection Algorithm Implementation for a Strip Detector Readout System in a Time Projection Chamber Polarimeter

A fundamental challenge in a spaceborne application of a gas-based Time Projection Chamber (TPC) for observation of X-ray polarization is handling the large amount of data collected. The TPC polarimeter described uses the APV-25 Application Specific Integrated Circuit (ASIC) to readout a strip detector. Two dimensional photoelectron track images are created with a time projection technique and used to determine the polarization of the incident X-rays. The detector produces a 128x30 pixel image per photon interaction with each pixel registering 12 bits of collected charge. This creates challenging requirements for data storage and downlink bandwidth with only a modest incidence of photons and can have a significant impact on the overall mission cost. An approach is described for locating and isolating the photoelectron track within the detector image, yielding a much smaller data product, typically between 8x8 pixels and 20x20 pixels. This approach is implemented using a Microsemi RT-ProASIC3-3000 Field-Programmable Gate Array (FPGA), clocked at 20 MHz and utilizing 10.7k logic gates (14% of FPGA), 20 Block RAMs (17% of FPGA), and no external RAM. Results will be presented, demonstrating successful photoelectron track cluster detection with minimal impact to detector dead-time.

Polarimeter↗

Readout system for radiation detector

Improved electrical circuit determines the amount of light detected by a photomultiplier tube when its output signal is in the dark-current range of the tube. The low-intensity light to which the tube responds arises from a thermo-luminescent ionized dosimeter.

Baker, B. R.↗

Radiation detector readout system Patent

Circuit design for determining amount of photomultiplier tube light detection utilizing variable current source and dark current signals of opposite polarity

Baker, B. R.↗

Working model of the London moment readout system

The operating characteristics of a porous plug which has liquid helium on one side and which is pumped on under vacuum on the other side are discussed. The system investigated consists of a container of liquid helium which is well isolated, and the only means for mass flow out of the container is through a plug mode of porous material. The plug was assumed to have liquid helium on the container side while the other side of the plug is evacuated. Three cases were considered: (1) perfect evacuation with zero pressure, (2) evacuation through a chocked orifice, and (3) evacuation through a long, small diameter pipe with heating. Mass flow rates were determined along with mass flow at temperature above the lambda point temperature. Solutions were obtained for normal and superfluid velocity.

Hendricks, J. B.↗

A SQUID readout system for a superconducting gyroscope

A design of a read out system for a superconducting gyroscope to be used in an orbiting gyroscope relativity experiment is discussed. The 'London Moment' of the superconducting rotor, which lies along the spin axis of the rotor, will be measured with a SQUID-type magnetometer. The SQUID will be built around the gyro rotor, with a very close spacing to give an inductance between 10 millionths and 1 millionth Hy. A SQUID of this design should resolve 2.07 times 10 to the minus 19th weber. The angular resolution of the gyroscope will then be 0.0035 arc-second, which is sufficient for the intended experiment.

Hendricks, J. B.↗

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.↗

Application of wedge and strip image readout systems to detectors for astronomy

Microchannel plate (MCP) detector systems that use wedge and strip anodes for imaging radiation in the range 50 A to 8000 A are described. Test data, obtained from the calibration of the Extreme Ultraviolet Explorer Satellite detectors and the ARIA EUV aeronomy sensor is presented. The long-term performance characteristics of Z-stack microchannel plates are investigated and it is shown that stable operation is achieved after an initial settling period. Conventional and new anode designs and their potential for increasing the position resolution are discussed. Position resolution of better than 80 microns FWHM has been attained for 50 mm devices, and this is shown to be essentially independent of event location. Image nonlinearity of less than 0.3 percent has been achieved with stability to better than 0.1 percent. Differential nonlinearity of less than 1 percent and stability to better than 1 percent have been obtained. Measurements of the quantum efficiency of a CsI photocathode on an MCP are presented, demonstrating efficiencies as high as 47 percent.

Siegmund, O. H. W.↗