Search NASA⌕ Search

SEARCH · Search NASA

Results for “receiver synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Pulsar Based Timing for Grid Synchronization

Existing synchronization systems in the power grid, such as the global positioning system, are susceptible to temporary or permanent failures due to various unpredictable and uncontrollable factors such as cyber-attack and electromagnetic interferences, thus affecting the accuracy and reliability of generated timing signal. In this article, a pulsar astronomy-based timing system is proposed to provide an alternative synchronization signal. Further, this clock will offer significant security improvements to power grid applications, such as a wide-area monitoring system, which depends on a precise timing signal. The hardware and software frameworks are described in detail. First, a high-speed sampling hardware platform is designed to collect signals from radio telescopes. Then a periodic pulse extraction method with three steps is proposed to process the pulsar signal, including polyphase filterbanks, incoherent de-dispersion, and sliding window folding. Lastly, three experiments are conducted to verify the effectiveness of the frameworks. The generated pulsar timing pulse is presented, and the factors affecting its accuracy are also discussed. The analysis results demonstrate that the pulsar signals can provide high-accurate timing pulses for grid synchronization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Synchrophasor measurement method for power systems

A synchrophasor measurement method for a device configured to take synchronized measurements in a power system is provided. The synchrophasor measurement method includes receiving global positioning system (GPS)-synchronized samples of a signal sensed by the device from the power system; determining a level of distortion of the signal; selecting, based on the level of distortion, a computation method, the computation method being one of an improved zero-crossing (IZC) method and an enhanced phase-lock-loop (EPLL) method; performing the selected computation method to determine at least one parameter of the signal at a reporting frequency, which is at least twice a line frequency of the power system; and outputting, at the reporting frequency, the at least one parameter to an operator of the power system to allow the operator to perform at least one of a monitoring and a controlling of at least one element of the power system.

Yao, Wenxuan↗

Integrating Hybrid-Clustering and Localized Regression for Time Synchronization of a Hierarchical Underwater Acoustic Sensor Array

Time synchronization is a critical requirement for the application of underwater acoustic sensor network (UWSN). Although a number of time synchronization protocols have been proposed for UWSN, none of them can be directly applied to autonomous acoustic receivers due to lack of hardware platform to communicate with each other. In this paper, we propose a machine learning-based time synchronization framework for autonomous receiver arrays, using the Juvenile Salmon Acoustic Telemetry System as a case study. The proposed framework consists of array partition and time synchronization. Using detections of receiver attached beacons as input, this framework synchronizes all receiver clocks to a root receiver clock. The framework has been successfully used in a field study at Trevallyn Dam forebay in Tasmania, Australia.

Fu, Tao↗

A simple amplitude decision based symbol timing synchronization method for real-time IMDD-OOFDM systems

A simple amplitude decision based symbol timing synchronization method for real-time IMDD-OOFDM transmission systems is proposed and experimentally evaluated by using directly modulated DFB laser in 25 km SSMF. The experimental results show that the hardware resource consumption of the proposed synchronization technique is only 6% of the total system which can effectively release the computation complexity without sacrificing the synchronization accuracy. Less than 2 samples offset error of synchronization accuracy can be achieved at received optical power as low as − 20 dBm without employing correlation and multiplication operations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Event Fanout/Receiver (evfr) v1.0

The event fanout-receiver is an event-based timing system implementation capable of synchronizing (with respect to clock, events and triggers) to an upstream event generator. This can be used in 2 modes: fanout or receiver. the first one receives 1 upstream timing streams and fanouts it to 36. The second one receives and decodes the stream. This has been in use by ALS for many years and this is a similar implementation, but providing a more flexible configuration

Russo, Lucas↗

Systems and methods for synchronizing converter modules

Various examples are directed to a converter system comprising first and second series-connected converter modules and a synchronization circuit. The synchronization circuit may modulate a reference signal onto a carrier signal to generate a synchronization current signal and the synchronization current signal to an output current of the converter system to generate an aggregated output current. A first converter module may receive the aggregated output current from a first current sensor and generate a first reproduced synchronization signal at least in part from the aggregated output current. A first switch control signal for switching at least one switch at the first converter may be generated based at least in part on the first reproduced synchronization signal.

Cox, Robert Williams↗

Detecting faults in turbine generators

Turbine generator faults can be detected by receiving a current signal from the turbine generator, and synchronously sampling the current signal to obtain a set of current signal samples that are evenly spaced in the phase domain, in which phase differences between adjacent current signal samples in the set of current signal samples are substantially the same. The process includes generating a frequency spectrum of the current signal samples, identifying one or more excitations in the frequency spectrum, and detecting a fault in the turbine generator based on the one or more excitations in the frequency spectrum.

Qiao, Wei↗

Sampling synchronization through GPS signals

A method uses a distributed data acquisition system with multiple, physically unconnected, data acquisition units, that can be in wireless communication with a remote host, to timestamp measurement data with sub-microsecond time base accuracy of sampling clock relative to an absolute timeframe. A current absolute time is derived from messages received from a satellite radio beacon positioning system (GPS). Measurement data is sampled by each unit at a specified sampling rate. Using hardware logic, batches of sampled data are associated with corresponding timestamps representing the absolute time at which the data was sampled. Data and timestamps may be transmitted to the host. A time offset bias is compensated by comparing timestamps against a nominal time based on start time and nominal sampling rate. The sampling clock rate may be disciplined using time pulses from the GPS receiver. An initial start of data sampling by all units can also be synchronized.

Zhuge, James Q.↗

Uncertainty Error Modeling for Non-Linear State Estimation With Unsynchronized SCADA and µPMU Measurements

Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro phasor measurement units (µPMUs) facilitate co-synchronized measurements with high granularity, albeit at an often prohibitively expensive installation cost. Supervisory control and data acquisition (SCADA) measurements can supplement µPMU data, although they are received at a slower sampling rate. Further complicating matters is the uncertainty associated with load dynamics and unsynchronized measurements–not only are the SCADA and µPMU measurements not synchronized with each other, but the SCADA measurements themselves are received at different time intervals with respect to one another. This paper proposes a non-linear state estimation framework which models dynamic load uncertainty error by updating the variances of the unsynchronized measurements, leading to a time-varying system of weights in the weighted least squares state estimator. Case studies are performed on the 33-Bus Distribution System in MATPOWER, using Ornstein–Uhlenbeck stochastic processes to simulate dynamic load conditions.

Cooper, Austin↗

Towards high data-rate diffusive molecular communications: A review on performance enhancement strategies

Diffusive molecular communications (DiMC) have recently gained attention as a candidate for nano- to micro- and macro-scale communications due to its simplicity and energy efficiency. As signal propagation is solely enabled by Brownian motion mechanics, DiMC faces severe inter-symbol interference (ISI), which limits reliable and high data-rate communications. Herein, recent literature on DiMC performance enhancement strategies is surveyed; key research directions are identified. Signaling design and associated design constraints are presented. Here, studies on fundamental information theoretic limits of DiMC channel are reviewed. Classical and novel transceiver designs are discussed with an emphasis on methods for ISI mitigation and performance-complexity tradeoffs. Key parameter estimation strategies such as synchronization and channel estimation are considered in conjunction with asynchronous and timing error robust receiver methods. Finally, source and channel coding in the context of DiMC is presented.

42 ENGINEERING↗

Neoadjuvant Chemotherapy does not Increase Complications in Oncoplastic Breast-Conserving Surgery

Background: Oncoplastic breast-conserving surgery (OBCS) broadens the indications for breast conservation. Neoadjuvant systemic chemotherapy (NAC) is used increasingly in the treatment of patients with early-stage and locally advanced breast cancer. This study aimed to evaluate the outcomes for patients who received NAC followed by OBCS. Methods: A retrospective chart review was performed for all patients who underwent OBCS involving the mastopexy/breast-reduction technique, including synchronous mastopexy/breast reduction for symmetry, at the University of Texas MD Anderson Cancer Center between January 2010 and January 2016. Patients who had received NAC were compared with those who had undergone surgery first. Demographic, treatment, and outcomes data were collected. Results: The study included 429 patients, corresponding to 713 breasts. Of these patients, 122, corresponding to 199 breasts, received NAC. The patients who received NAC were younger (p < 0.001) and had a more advanced cancer stage (p < 0.001). The overall complication rate per patient was 25.9%, with major complications occurring in 9.1% of the patients. After adjustment for risk factors, NAC was not shown to be associated with an increased risk of complications or delayed adjuvant radiation therapy (p = 0.37), irrespective of the chemotherapy regimen used or whether the interval between NAC and surgery was 4 weeks or longer. Conclusions: In a high-volume center, OBCS can be performed safely for carefully selected patients after NAC without an increased risk of complications or delayed adjuvant radiation therapy. An interval of at least 4 weeks between completion of NAC and surgery can be regarded as safe irrespective of the chemotherapy regimen used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-Layer Predictive Controller for V2G and G2V Services Using on Wireless Power Transfer Technology

This paper presents a comprehensive solution that allows electric vehicles (EV) to autonomously charge and discharge their batteries wirelessly during long term parking and/or the transient stops. A two-layer power-flow controller for bidirectional wireless power transfer system (BWPTS) in EVs applications is proposed. The proposed controller can manage the bidirectional power-flow between EV and surrounding infrastructures such as power grid, home microgrid, building micro-grid, road or another vehicle. It consists of two levels of control; the first is responsible for communicating with the surrounding infrastructures and gathering information from driver, charging station, power grid and battery management system and then, based on these information, it estimates the EV's psychological price as a function of its battery's state-of-charge (SOC) and compares it with the energy price to decide whether to charge, discharge or abstain, and how much the charging or discharging rate. The second layer receives the reference signal from the first one and generates the control parameters for two synchronized resonant converters (one is on the vehicle side and the other is on the grid side) to provide the requited power-flow. The proposed controller is adaptively estimating the system parameters to consider the misalignment conditions effects on the system performance. The parameter estimation is achieved using only one voltage sensor. The second layer control is designed based on a new analytical modeling for the power flow in the system. For verification purposes, a prototype for BWPTS was built and driven by the proposed controller, which was implemented using a field-programmable gate array (FPGA) integrated circuit. The proposed controller provides very fast and stable response during both the transient and steady state operation in comparison with the conventional PI controller.

33 ADVANCED PROPULSION SYSTEMS↗

Compressor system with heat recovery

A system includes a first working fluid compressor configured to pressurize a working fluid, and a prime mover coupled to the first working fluid compressor and configured to provide a mechanical input into the first working fluid compressor. An exhaust assembly is coupled to the prime mover and is configured to receive exhaust heat from the prime mover, the exhaust assembly including a generator configured to generate electric current based on the exhaust heat received by the exhaust assembly. A second working fluid compressor includes an electric motor electrically and synchronously coupled to the generator and configured to pressurize the working fluid.

Torrey, David Allan↗

A cryogenic continuously rotating half-wave plate mechanism for the POLARBEAR-2b cosmic microwave background receiver

In this report we present the design and laboratory evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the POLARBEAR-2b (PB-2b) cosmic microwave background receiver, the second installment of the Simons Array. PB-2b will observe at 5200 m elevation in the Atacama Desert of Chile in two frequency bands centered at 90 GHz and 150 GHz. In order to suppress atmospheric 1/f noise and mitigate systematic effects that arise when differencing orthogonal detectors, PB-2b modulates linear sky polarization using a CHWP rotating at 2 Hz. The CHWP has a 440 mm clear aperture diameter and is cooled to ≈50 K in the PB-2b receiver cryostat. It consists of a low-friction superconducting magnetic bearing and a low-torque synchronous electromagnetic motor, which together dissipate < 2 W. During cooldown, a grip-and-release mechanism centers the rotor to < 0.5 mm, and during continuous rotation, an incremental optical encoder measures the rotor angle with a noise level of 0.1 μrad/Hz. We discuss the experimental requirements for the PB-2b CHWP, the designs of its various subsystems, and the results of its evaluation in the laboratory. The presented CHWP has been deployed to Chile and is expected to see first light on PB-2b in 2020 or 2021.

47 OTHER INSTRUMENTATION↗

A new method of relative radiometric calibration for hyperspectral imaging based on skylight monitor

A new method of relative radiometric calibration based on the skylight monitor is presented for airborne hyperspectral remote sensing to eliminate the negative effect on data resulting from the time-varying skylight during a long flight. In terms of large area operation of mapping or spectral imaging, a static radiation model hardly reveals actual cases as external environment keeps changing. Compared with common considerable factors, fluctuation of skylight is the primary one that may observably affect spectral imaging continuously leading to radiation changes upon flight lines. To get rid of the influence of skylight on spectral imagery and monitoring the variation during the flight, we assemble a set of skylight monitor fixed to the aircraft cabin for the sake of recording the semi-spherical skylight keeping synchronization with hyperspectral imaging system and the position and orientation system. The skylight monitor consists of a cosine corrector on the top receiving the skylight, a stable optical fiber and a visible and near-infrared linear array modular spectrometer. The corresponding matched data of skylight with each frame of images is used to correct related digital number after stripe non-uniformity correction, achieving mean relative standard deviation (coefficient of variation or CV) of under 6% for all 256 bands. The final result shows a satisfactory calibrated image of an appropriate evaluation criteria with contrast of the original image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗