Using a recirculating anaerobic dynamic membrane bioreactor to treat hydrothermal liquefaction aqueous by-product

Hydrothermal liquefaction (HTL) has the potential to improve resource recovery at water resource recovery facilities (WRRF), but the production of a high-strength aqueous by-product (HTL-aq) is hampering HTL implementation. The formation of biofilms in anaerobic digestion have been shown to be useful when degrading recalcitrant compounds present in HTL-aq due to the promotion of direct interspecies electron transfer (DIET) and increase in the microbial activity of syntrophic and methanogenic populations. The Recirculating Anaerobic Dynamic Membrane Bioreactor (RAnDMBr) was able to degrade 65% of the chemical oxygen demand (COD) at 1.5 ± 0.2 g COD LR −1 day −1 and 5.6 ± 2.3 days producing 0.19 ± 0.02 LCH4 gCOD fed −1 . However, adding a solution rich in nutrients on a daily basis was necessary. The system presented microbial populations able to degrade aromatic compounds (i.e., Anaerolinaceae) to perform DIET and syntrophy (i.e., Syntrophus) and methanogens (i.e., Methanobacterium and Methanosarcina) with the biofilm having a higher relative abundance of methanogens than the suspended biomass. Increasing the organic loading rate to 2 g COD LR −1 day −1 caused inhibition in the system by accumulation of volatile fatty acids, probably due to an increase in phenol, N-heterocyclic and aromatic compounds. Overall, this research shows that the RAnDMBr can be used to treat HTL-aq in WRRF without inhibition at OLRs of 1.5 ± 0.2 g COD LR −1 day −1 or lower, making HTL-aq treatment more feasible. Future research should focus co-digestion of HTL-aq with a co-substrate rich in nutrients and on fouling mitigation strategies that will allow to increase the recirculation ratio to promote advective substrate transport through the biofilm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Hot Water Recirculation Systems: Designing for Success [Slides]

This presentation will focus on on-demand hot water recirculation systems and how they contribute to energy and water conservation in residential buildings. This work illustrates best practices for designing, installing, and operating these systems, drawing from research and field testing to provide practical recommendations. The ultimate goal is to reduce wait times for hot water, comply with current energy codes, and lower both energy use and greenhouse gas emissions, while improving user satisfaction. In the upcoming slides, we'll dive into case studies and explore the latest technological advancements that help achieve these objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Design improvements for a recirculating reactor: Enhanced temperature measurement and sample-isolated reactivity in steady-state kinetic studies

Building upon a previous recirculating reactor design [S.A. Tenney, K. Xie, J.R. Monnier, A. Rodriguez, R.P. Galhenage, S. Audrey, D.A. Chen, Rev. Sci. Instrum. 84, 104101 (2013)], we present significant improvements that address key limitations in steady-state kinetic measurements for heterogeneous catalysis. The enhanced reactor design features direct sample heating with a focused IR lamp and temperature measurement in direct contact with the sample, enabling more accurate temperature control and improved kinetic analysis. A critical advancement is the isolation of sample reactivity from reactor wall contributions, ensuring that only the sample contributes to measured reaction rates. This was a limitation in earlier designs where the entire reactor contributed to the observed reactivity. The system incorporates a bypass flow cell for direct comparison with powder catalysts under identical conditions using a standard plug-flow reactor configuration. We demonstrate these capabilities through CO oxidation experiments on Pt(111) single crystals and graphene-passivated Pt(111), highlighting the system's ability to differentiate catalytic activity in model systems and directly compare them with high surface area powder catalysts. This reactor is particularly suited for thin films and low surface area catalysts that are not effectively evaluated in traditional flow reactors, especially for samples with low numbers of active sites or slow reaction rates.

36 MATERIALS SCIENCE

CERF Visualization: Projected locations of new natural gas combined cycle power plants (with recirculating cooling) in Wyoming, USA (2020-2050)

Visualization of CERF outputs for years 2030-2050 in 5-year time steps for a region in Wyoming, USA. This visualization was built using a custom CesiumJS application. The region of interest was zoomed into and then the app shows the layered application of natural gas combined cycle power plants (with recirculating cooling) suitability criteria, show the siting for each year in planform, simulates the selection of a site using Net Locational Cost, and then zooms into to show a single functional gas plant and simulates its connection to the grid.

CERF

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell

Inertia-induced mixing and reaction maximization in laminar porous media flows

Solute transport and biogeochemical reactions in porous and fractured media flows are controlled by mixing, as are subsurface engineering operations such as contaminant remediation, geothermal energy production, and carbon sequestration. Porous media flows are generally regarded as slow, so the effects of fluid inertia on mixing and reaction are typically ignored. Here, we demonstrate through microfluidic experiments and numerical simulations of mixing-induced reaction that inertial recirculating flows readily emerge in laminar porous media flows and dramatically alter mixing and reaction dynamics. An optimal Reynolds number that maximizes the reaction rate is observed for individual pore throats of different sizes. This reaction maximization is attributed to the effects of recirculation flows on reactant availability, mixing, and reaction completion, which depend on the topology of recirculation relative to the boundary of the reactants or mixing interface. Recirculation enhances mixing and reactant availability, but a further increase in flow velocity reduces the residence time in recirculation, leading to a decrease in reaction rate. The reaction maximization is also confirmed in a flow channel with grain inclusions and randomized porous media. Interestingly, the domain-wide reaction rate shows a dramatic increase with increasing Re in the randomized porous media case. This is because fluid inertia induces complex three-dimensional flows in randomized porous media, which significantly increases transverse spreading and mixing. This study shows how inertial flows control reaction dynamics at the pore scale and beyond, thus having major implications for a wide range of environmental systems.

Chen, Michael A. (ORCID:0000000294614710)

Calculating the Effects of Solids Input and Removal as a Temperature Control in the Advanced Scale Up Reactor Experiment (ASURE) Facility at NETL Using Aspen

The Advanced Scale Up Reactor Experiment (ASURE) facility at NETL is being designed to be a fuel-flexible multi-purpose reactor that can be used for pyrolysis/gasification or evaluation of other high pressure “circulating fluidized bed” (CFB) chemical processes. The initial system design calculations for pyrolysis/gasification are presented in this work showing the expected performance of the ASURE facility when used as a biomass conversion reactor. Several other areas of application include gasification of any carbonaceous fuel including biomass, coal, plastics, and other waste materials. The reactor can therefore be used to produce SYNGAS of various compositions and hydrogen as well as other high value chemicals resulting from a typical tuned gasification process. This paper discusses an ASPEN model of the facility, focusing on the riser of the CFB reactor and the solids recirculation loop. The ASPEN model divides the riser into two sections. A bottom section which receives ash, char and sand which have been recirculated from a return loop. In this section an inert fluidization gas, (N2 or CO2), is introduced which acts as the primary mover of the solids through the system. The bottom section is equipped with a restricted air feed so that the recirculated char can be partially oxidized. This oxidation process along with the inventory of recirculating sand are used to effectively control the temperature in the following two chemical conversion sections of the reactor which are the pyrolysis zone followed by a tar cracking zone. Fresh fuel is added to the pyrolysis zone and undergoes drying and devolatilization. The products ash, char, volatile matter, and water vapor exit the pyrolysis zone and enter the reaction block for tar cracking. Steam and CO2 gasification reactions will be incorporated into the tar cracking zone, however at the design operating temperature, conversion from these reactions is expected to be essentially zero. The unit when completed in 2026 will test mixtures of biomass, plastics, and waste coal. This presentation discusses the basic ASPEN engineering design model for this project and provides preliminary sensitivity studies to determine how the various parts of the reactor will perform.

ASSURE

Calculating the Effects of Solids Input and Removal as a Temperature Control in the Advanced Scale Up Reactor Experiment (ASURE) Facility at NETL Using Aspen

The Advanced Scale Up Reactor Experiment (ASURE) facility at NETL is being designed to be a fuel-flexible multi-purpose reactor that can be used for pyrolysis/gasification or evaluation of other high pressure “circulating fluidized bed” (CFB) chemical processes. The initial system design calculations for pyrolysis/gasification are presented in this work showing the expected performance of the ASURE facility when used as a biomass conversion reactor. Several other areas of application include gasification of any carbonaceous fuel including biomass, coal, plastics, and other waste materials. The reactor can therefore be used to produce SYNGAS of various compositions and hydrogen as well as other high value chemicals resulting from a typical tuned gasification process. This paper discusses an ASPEN model of the facility, focusing on the riser of the CFB reactor and the solids recirculation loop. The ASPEN model divides the riser into two sections. A bottom section which receives ash, char and sand which have been recirculated from a return loop. In this section an inert fluidization gas, (N2 or CO2), is introduced which acts as the primary mover of the solids through the system. The bottom section is equipped with a restricted air feed so that the recirculated char can be partially oxidized. This oxidation process along with the inventory of recirculating sand are used to effectively control the temperature in the following two chemical conversion sections of the reactor which are the pyrolysis zone followed by a tar cracking zone. Fresh fuel is added to the pyrolysis zone and undergoes drying and devolatilization. The products ash, char, volatile matter, and water vapor exit the pyrolysis zone and enter the reaction block for tar cracking. Steam and CO2 gasification reactions will be incorporated into the tar cracking zone, however at the design operating temperature, conversion from these reactions is expected to be essentially zero. The unit when completed in 2026 will test mixtures of biomass, plastics, and waste coal. This paper presents the basic ASPEN engineering design model for this project and provides preliminary sensitivity studies to determine how the various parts of the reactor will perform.

ASSURE

Valorizing Hydrothermal liquefaction aqueous phase via nanofiltration: Enhancing biocrude production from algal biomass

The hydrothermal liquefaction aqueous phase (HTL-AP), a nutrient- and carbon-rich waste byproduct of the HTL process, can be recirculated to enhance biocrude production efficiency. To avoid dilution of the HTL feedstock and reduced fuel quality associated with recirculating untreated HTL-AP, this study investigated nanofiltration to concentrate organic compounds and separate nutrients from HTL-AP of three algal biomass sources: an algal wastewater treatment system and two from harmful algal blooms in lakes. Up to 99% of the organics were recovered in the concentrated HTL-AP (retentate), and significant increases in both permeate flux and permeation of nitrogenous compounds were achieved by increasing HTL-AP temperature to 45 °C and pH to 11. Recirculating the concentrated HTL-AP increased biocrude yield by 70%-116% and reduced biocrude nitrogen content by up to 12%. The carbon and energy capture in the biocrude also increased by 66% and 68%, respectively.

09 BIOMASS FUELS

An extraction scheme for future CEBAF FFA based energy upgrade

Jefferson lab is considering an energy increase from current 12 GeV to 22 GeV for its CEBAF accelerator. This will be accomplished by recirculating 5-6 additional turns through two parallel CEBAF LINACs using an FFA arc at each end of the racetrack. The total recirculation turns would be 10 times, the first four turns use present conventional arcs to make the 180-degree bends from one LINAC to the other. However, the last 5-6 turns will all share a single beam line inside two FFA arcs. This reduces the footprint and the cost of the project significantly. On the other hand, having the trajectories of last 5-6 recirculating beams close to each other makes it challenging to extract beams from different passes with different energies. In this paper we will explain our present extraction system for 12 GeV, our challenges and limitations, and a possible extraction solution for the 22 GeV upgrade with the goal of extracting beam at different turns/energies to different experimental halls.

Accelerator Physics

Universal Injector at LERF – Baseline Design

A new electron injector complex has been proposed within the Low Energy Recirculating Facility (LERF) vault, which would serve both the 22 GeV CEBAF and the positron programs, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three cryomodules, five isochronous arcs and three straight sections, allowing electron beam acceleration up to 650 MeV. The injector offers the flexibility to extract 1-pass and 2-pass energy electrons, as needed for positron production, with final reconfiguration to a 3-pass 650 MeV injector for 22 GeV CEBAF. This paper provides an overview of the baseline design of the Universal injector complex, including the 8 MeV injector and the recirculator. A comprehensive suite of beam dynamics studies to validate our design is being launched, starting with start-to-end tracking with Elegant followed by the orbit correction and error mitigation.

Bogacz, A. [Thomas Jefferson National Accelerator

Beam Performance of the Positron Transport Line for CEBAF Positron Upgrade

The Low Energy Recirculator Facility (LERF) at Jefferson Lab, formerly operated for the Free-Electron Laser program, has been proposed as the injector complex for the planned 12 GeV CEBAF positron upgrade (Ce+BAF), with an additional pathway to support a potential 22 GeV CEBAF electron upgrade. In this configuration, LERF would generate and pre-accelerate positrons to 123 MeV, matching the present injection energy into the North Linac. Due to the relatively large emittance expected from the positron source, a comprehensive acceptance study has been performed from LERF through the CEBAF recirculating linacs and beam transport lines to the experimental halls. The objective is to establish the positron phase-space acceptance and provide design feedback to the positron production and capture systems. Furthermore, given CEBAF’s capability to deliver highly polarized beams, spin-tracking simulations have been carried out including magnet imperfections, alignment errors, and synchrotron-radiation–induced energy spread. Particular attention is given to the evolution of the spin tune and the corresponding depolarization mechanisms along the beam delivery path, especially for providing longitudinal polarization at the experimental halls. These results inform injector design choices and assess the overall feasibility of delivering high-polarization positron beams in CEBAF.

Ogur, S. [Thomas Jefferson National Accelerator Fa

Marginal Soils Index Analysis & Geospatial Data

This data package contains output files associated with Mongird et al. (in prep) organized into four dataset directories. Each dataset is described in more detail below. 1. Marginal Soils Index Analysis Description: This folder contains a csv file with land needs and availability by state, power generating technology type, and scenario in 2050 when suitable siting areas are additionally constrained to areas with increasing levels of soil marginality. Files: msi_constrained_siting_availability_2050.csv Variables: Scenario - Projected 2050 scenario name State - US state abbreviation Technology - Generating technology type solar = solar photovoltaic gas_cc_re = natural gas combined cycle (recirculating cooling) wind = onshore wind gas_cc_ccs_re = natural gas combined cycle with carbon capture sequestration (recirculating cooling) gas_cc_dry = natural gas combined cycle with (dry cooling) gas_cc_pond = natural gas combined cycle with (pond cooling) coal_conv_ccs_re = conventional coal with carbon capture sequestration (recirculating cooling) Req_Capacity_MW - The amount of rated capacity required in 2050 of the given technology type in the given state and under the given scenario from the capacity expansion plan Req_Capacity_Factor - The assumed capacity factor (fraction between 0 and 1) for the given technology type in the given state and under the given scenario by the capacity expansion plan Req_Land_km2 - The amount of land required (in km-squared) to host the required generating capacity that is capable of meeting the specified capacity factor for the given technology type in the given state and under the given scenario Req_Energy_TWh - Product of Req_Capacity_MW, Req_Capacity_Factor, and 8760/1e6 for the given technology type in the given state and under the given scenario MSI_Case - The level of MSI that siting the given technology is additionally constrained to, where >0 means siting is additionally constrained to suitable land areas that have an MSI value greater than 0 >=1 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 1 >=2 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 2 >=3 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 3 Soil Attribute Rasters Description: This folder contains geospatial raster files for individual soil parameters upscaled to the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of non-missing 30m resolution values. All raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. Files: avg_cond_raster_ .tif - Average conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm max_cond_raster_ .tif - Maximum conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm min_ph_raster_ .tif- Min pH values across all soil horizons within a depth of 40 inches. avg_ph_raster_ .tif - Average pH value across all soil horizons within a depth of 40 inches. max_ph_raster_ .tif- Max pH value across all soil horizons within a depth of 40 inches. erosion_factor_raster_ .tif - Product of k-factor and percent slope flood_freq_raster_ .tif - Number of months of the year during which the area is commonly, frequently, or very frequently flooded. max_sar_raster_ .tif - Maximum sodium adsorption ratio across all horizons within a depth of 40 inches rock_frac_raster_ .tif - Fraction of the upper 6 inches of soil composed of rock fragments larger than 3 inches. temp_regime_raster_ .tif - Soil temperature regime with the following key: 0 = pergelic 1 = gelic 2 = cryic 3 = frigid 4 = isofrigid 5 = mesic 6 = isomesic 7 = thermic 8 = isothermic 9 = hyperthermic 10 =isohyperthermic Marginal Soils Index Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index at the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of 30m resolution. Both raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. A value of 0 indicates that there were no soil attributes present that indicate marginal soil. NA values indicate that data was unavailable or bodies of water. Files: marginal_soils_index_30m_raster.tif marginal_soils_index_1km_raster.tif Marginal Soils Index Resource Potential Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index + Resource Potential (MSI+RP) score at 1km resolution for geothermal, solar, and wind technologies. Raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. NA values indicate that the location is not suitable for siting the given technology due to policy, environmental, socioeconomic, topological, and other constraints regardless of soil marginality level. Areas with values greater than or equal to zero represent the product of the normalized MSI value and the normalized resource potential value. Files: geothermal_msi_ep_score_raster.tif solar_msi_ep_score_raster.tif wind_msi_ep_score_raster.tif Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Agriculture

Marginal Soils Index Analysis & Geospatial Data

This data package contains output files associated with the Mongird et al. paper entitled "Can US power grid expansion avoid prime agricultural lands?" and is organized into four dataset directories. Each dataset is described in more detail below. 1. Marginal Soils Index Analysis Description: This folder contains a csv file with land needs and availability by state, power generating technology type, and scenario in 2050 when suitable siting areas are additionally constrained to areas with increasing levels of soil marginality. Files: msi_constrained_siting_availability_2050.csv Variables: Scenario - Projected 2050 scenario name State - US state abbreviation Technology - Generating technology type solar = solar photovoltaic gas_cc_re = natural gas combined cycle (recirculating cooling) wind = onshore wind gas_cc_ccs_re = natural gas combined cycle with carbon capture sequestration (recirculating cooling) gas_cc_dry = natural gas combined cycle with (dry cooling) gas_cc_pond = natural gas combined cycle with (pond cooling) coal_conv_ccs_re = conventional coal with carbon capture sequestration (recirculating cooling) Req_Capacity_MW - The amount of rated capacity required in 2050 of the given technology type in the given state and under the given scenario from the capacity expansion plan Req_Capacity_Factor - The assumed capacity factor (fraction between 0 and 1) for the given technology type in the given state and under the given scenario by the capacity expansion plan Req_Land_km2 - The amount of land required (in km-squared) to host the required generating capacity that is capable of meeting the specified capacity factor for the given technology type in the given state and under the given scenario Req_Energy_TWh - Product of Req_Capacity_MW, Req_Capacity_Factor, and 8760/1e6 for the given technology type in the given state and under the given scenario MSI_Case - The level of MSI that siting the given technology is additionally constrained to, where >0 means siting is additionally constrained to suitable land areas that have an MSI value greater than 0 >=1 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 1 >=2 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 2 >=3 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 3 Soil Attribute Rasters Description: This folder contains geospatial raster files for individual soil parameters upscaled to the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of non-missing 30m resolution values. All raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. Files: avg_cond_raster_ .tif - Average conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm max_cond_raster_ .tif - Maximum conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm min_ph_raster_ .tif- Min pH values across all soil horizons within a depth of 40 inches. avg_ph_raster_ .tif - Average pH value across all soil horizons within a depth of 40 inches. max_ph_raster_ .tif- Max pH value across all soil horizons within a depth of 40 inches. erosion_factor_raster_ .tif - Product of k-factor and percent slope flood_freq_raster_ .tif - Number of months of the year during which the area is commonly, frequently, or very frequently flooded. max_sar_raster_ .tif - Maximum sodium adsorption ratio across all horizons within a depth of 40 inches rock_frac_raster_ .tif - Fraction of the upper 6 inches of soil composed of rock fragments larger than 3 inches. temp_regime_raster_ .tif - Soil temperature regime with the following key: 0 = pergelic 1 = gelic 2 = cryic 3 = frigid 4 = isofrigid 5 = mesic 6 = isomesic 7 = thermic 8 = isothermic 9 = hyperthermic 10 =isohyperthermic Marginal Soils Index Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index at the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of 30m resolution. Both raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. A value of 0 indicates that there were no soil attributes present that indicate marginal soil. NA values indicate that data was unavailable or bodies of water. Files: marginal_soils_index_30m_raster.tif marginal_soils_index_1km_raster.tif Marginal Soils Index Resource Potential Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index + Resource Potential (MSIxRP) score at 1km resolution for geothermal, solar, and wind technologies. Raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. NA values indicate that the location is not suitable for siting the given technology due to policy, environmental, socioeconomic, topological, and other constraints regardless of soil marginality level. Areas with values greater than or equal to zero represent the product of the normalized MSI value and the normalized resource potential value. Files: geothermal_msi_rp_score_raster.tif solar_msi_rp_score_raster.tif wind_msi_rp_score_raster.tif Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Agriculture

Machine learning modeling and model predictive control of a closed-circuit reverse osmosis system

Closed-circuit reverse osmosis (CCRO) offers a flexible and energy-efficient alternative to conventional reverse osmosis by operating in a semi-batch mode that recycles brine, enabling higher recovery rates and reduced specific energy consumption (SEC). However, developing accurate, system-level dynamic models for CCRO remains challenging due to its nonlinear, multi-phase operation and sensitivity to variable feed water conditions. Traditional modeling approaches, such as NARMAX (nonlinear autoregressive moving average with exogenous inputs), often struggle to generalize across varying inlet feed concentrations, necessitating frequent parameter re-estimation and limiting their utility for real-time control applications. To address these limitations, we developed a long short-term memory (LSTM) neural network model trained on an extensive experimental data set from a CCRO pilot plant. The model accepts three inputs, feed flow rate, recirculation flow rate, and initial feed conductivity, and predicts three key outputs: reject conductivity, feed pump power draw, and recirculation pump power draw. We validated the LSTM model against experimental data, demonstrating its ability to distinguish between different feed conductivities and adapt to variable flow rates. Subsequently, we incorporated the LSTM model within a nonlinear model predictive control (MPC) scheme and conducted closed-loop simulations to optimize the integrated SEC (iSEC). In conclusion, the results project up to a 6% reduction in iSEC by using MPC to optimize performance over the entire experiment duration, without requiring any random excitation for data collection or parameter re-estimation.

Desalination

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.