Search NASA⌕ Search

SEARCH · Search NASA

Results for “record”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Guide to Handle Electronic and Physical Records Requests for Service Innovation-Records Management Services (SI-RMS) Staff

The Electronic Records Management System (ERMS) is Los Alamos National Laboratory’s method for consolidating, tracking, and preserving valuable records according to National Archives and Records Administration (NARA) requirements. Like an online library catalog, the ERMS stores unclassified electronic records that are retrievable from a remote computer system, and the ERMS contains a list of unclassified physical record holdings (paper documents, audiovisual materials, photographs, etc.) that are stored in the LANL Records Center and may be checked out. This guide covers new processes that affect both physical and electronic records. Each process begins when an employee (referred to as the requester) submits a request through the AskIT ticketing system (askit.lanl.gov). A request may include submitting a record, retrieving a record, or destroying a record.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Nasa Records Disposition Handbook: Procedures Governing the Retention, Retirement, and Destruction of Agency Records

This handbook sets forth the disposition of official records of the National Aeronautics and Space Administration. Its provisions are applicable to NASA Headquarters and all field installations. This revised edition has been enlarged in scope and re-titled to provide guidance in all aspects of records retirements, transfers, destruction, and retrievals from Federal Records Centers. New records control schedules have been added and others revised. Also included are procedures for making recommendations for improved coverage of records categories by additions or revisions. The NASA Records Control Schedules are issued under authority of the NASA Records Management Officer in accordance with Section 101-11.406, Federal Property Management Regulations. They were approved for NASA use by the National Archives and Records Service, the General Accounting Office, and by the Joint Committee on the Disposition of Executive Papers, U.S. Congress.

Source record↗

NASA records retention schedules: Procedures governing the retention, retirement, and destruction of agency records

This handbook sets forth the minimum retention periods of official records of NASA. Its provisions are applicable to NASA Headquarters and all field installations. This revised edition has been correlated to the NASA Uniform Files Index (UFI) (NHB 1442.1B), the General Records Schedules produced by the National Archives and Records Administration (NARA), and has been enlarged in scope to cover Privacy Act Systems of Records and record series previously omitted. Guidance is provided in the areas of record retirement, transfer, and retrieval from Federal Record Centers (FRC) and disposal actions. Included are provisions for making changes to these schedules by addition of new items or revision of current items. The NASA Records Retention Schedules (NRRS) were approved for NASA use by NARA, the General Services Administration, and the General Accounting Office.

Benita A Cooper↗

Development and Use of Mark Sense Record Cards for Recording Medical Data on Pilots Subjected to Acceleration Stress

A TIME-HONORED system of recording medical histories and the data obtained on physical and laboratory examination has been that of writing the information on record sheets that go into a folder for each patient. In order to have information which would be more readily retrieved, 'a program was initiated in 1952 by the U. S. Naval School of Aviation Medicine in connection with their "Care of the Flyer" study to place this information on machine record cards. In 1958, a machine record card method was developed for recording medical data in connection with the astronaut selection program. Machine record cards were also developed by the Aero Medical Laboratory, Wright-Patterson AFB, Ohio, and the Aviation Medical Acceleration Laboratory, Naval Air Development Center, Johnsville, Pennsylvania, for use in connection with a variety of tests including acceleration stress.1 Therefore, a variety of systems resulted in which data of a medical nature could easily be recalled. During the NASA, Ames Research Center centrifuge studies/'S the pilot subjects were interviewed after each centrifuge run, or series of runs, and subjective information was recorded in a log book by the usual history taking methods referred to above. After the methods Were reviewed, it' was recognized that a card system would be very useful in recording data from our pilots after they had been exposed to acceleration stress. Since the acceleration stress cards already developed did not meet our requirements, it was decided a different card was needed.

Smedal, Harald A.↗

A 2000 year varve-based climate record from the central Brooks Range, Alaska

Varved minerogenic sediments from glacial-fed Blue Lake, northern Alaska, are used to investigate late Holocene climate variability. Varve thickness measurements track summer temperature recorded at Atigun Pass, located 41 km east at a similar elevation (r2 = 0.31, P = 0.08). Results indicate that climate in the Brooks Range from 10 to 730 AD (varve year) was warm with precipitation inferred to be higher than during the twentieth century. The varve-temperature relationship for this period was likely compromised and not used in our temperature reconstruction because the glacier was greatly reduced, or absent, exposing sub-glacial sediments to erosion from enhanced precipitation.

54 ENVIRONMENTAL SCIENCES↗

Mach-Zehnder recording systems for pulsed power diagnostics

Fiber-optic transmission and recording systems, based on Mach-Zehnder modulators, have been developed and installed at the National Ignition Facility (NIF), and are being developed for other pulsed-power facilities such as the Z accelerator at Sandia, with different requirements. We present the design and performance characteristics for the mature analog links, based on the system developed for the Gamma Reaction History diagnostic at the OMEGA laser and at NIF. For a single detector channel, two Mach-Zehnders are used to provide high dynamic range at the full recording bandwidth with no gaps in the coverage. We present laboratory and shot data to estimate upper limits on the radiation effects as they impact recorded data quality. Finally, we will assess the technology readiness level for mature and developing implementations of Mach-Zehnder links for these environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Titanium, vanadium and chromium valences in silicates of ungrouped achondrite NWA 7325 and ureilite Y-791538 record highly-reduced origins

Titanium, Cr, and V valences were determined by applying micro-X-ray Absorption Near Edge Structure (micro-XANES) spectroscopy methods to individual grains of olivine and pyroxene in the ungrouped achondrite NWA 7325 and ureilite Y-791538, as well as to plagioclase in NWA 7325. The advantages of applying multiple, multivalent-element-based oxybarometers to individual grains are (1) the ability to cover the entire oxygen fugacity (fO2) range encountered in nature, and (2) the increased reliability from consistent results for semi-independent fO2 proxies. fO2 values were inferred from each mineral valence determination after correcting with available laboratory-experiment-derived, valence-specific partition coefficients to obtain melt valences and then calibrating with the fO2 values of the relevant equal species proportions points suggested for igneous (primarily basaltic) systems. The resulting olivine and pyroxene valences are highly reduced and similar in the two meteorites with substantial fractions of Cr2+, Ti3+ and V2+. The exception is Cr in NWA 7325 pyroxene which is much more oxidized than the Cr in its olivine. Chromium and Ti in plagioclase in NWA 7325 is relatively oxidized (V valence not determined). The anomalously oxidized Cr in NWA 7325 pyroxene may be due to a secondary reheating event that oxidized Cr in the pyroxene without similarly oxidizing Ti and V. Such a separation of the redox couples may be an effect of re-equilibration kinetics, where the valence of Cr would be more rapidly modified. These valences yielded similar mean fO2s for the two meteorites; IW-3.1 ± 0.2 for NWA 7325 and IW-2.8 ± 0.2 for Y-791538, consistent with an origin of NWA 7325 in either Mercury or an asteroid that experienced redox conditions similar to those on the ureilite parent body.

58 GEOSCIENCES↗

A multi-century tree-ring record of spring flooding on the Mississippi River

Widespread destructive flooding is a common phenomenon along the Lower Mississippi River, and river managers have long sought to understand the temporal variability and relevant climatic factors of the system. One of the important drawbacks to better understanding the flood regime of this and similar large river systems is the relatively short instrumental record of flooding. In this study, we present a novel, annually-resolved tree-ring record of spring flooding based on anatomically anomalous “flood rings” preserved in trees growing about 60 km downstream of the Mississippi and Ohio River confluence. Our chronology records 39 flood-ring years between 1770 and 2009 including nearly all of the observed significant floods of the 20th century as well as severe floods documented in prior centuries. Comparison of the flood ring record with stream gage observations suggests that large-magnitude floods lasting for more than 10 days, during the spring flood season, are most likely to cause a flood ring in sampled trees. Instrumental and paleo-proxy records of atmospheric circulation features relevant to spring flooding on the Lower Mississippi were also examined. Results of this research suggest that similar flood-ring records could provide important insight into flood history elsewhere in the Mississippi River system and perhaps climate variability over North America.

Engineering↗

Fast optical recording media based on semiconductor nanostructures for image recording and processing

Fast optical recording media based on semiconductor nanostructures (CdTe, GaAs) for image recording and processing with a speed to 10{sup 6} cycle/s (which exceeds the speed of known recording media based on metal-insulator-semiconductor-(liquid crystal) (MIS-LC) structures by two to three orders of magnitude), a photosensitivity of 10{sup -2}V/cm{sup 2}, and a spatial resolution of 5-10 (line pairs)/mm are developed. Operating principles of nanostructures as fast optical recording media and methods for reading images recorded in such media are described. Fast optical processors for recording images in incoherent light based on CdTe crystal nanostructures are implemented. The possibility of their application to fabricate image correlators is shown.

36 MATERIALS SCIENCE↗

Scale and the isotopic record of C4 plants in pedogenic carbonate: from the biome to the rhizosphere

The 13C/12C ratio in pedogenic carbonate (i.e., CaCO3 formed in soil) is a significant tool for investigating C4 biomes of the past. However, the paleoecological meaning of d13C values in pedogenic carbonate can change with the scale at which one considers the data. We describe studies of modern soils, fossil soils, and vegetation change in the Chihuahuan Desert of North America and elsewhere that reveal four scales important for paleoecologic interpretations. (1) At the broadest scale, the biome scale (hundreds to millions of km2), an isotopic record interpreted as C3 vegetation replacing C4 grasslands may indicate invading C3 woody shrubs instead of expanding C3 forests (a common interpretation). (2) At the landscape scale (several tens of m2 to hundreds of km2), the accuracy of scaling up paleoclimatic interpretations to a regional level is affected by the landform containing the isotopic record. (3) At the soil-profile scale (cm2 to m2), soil profiles with multiple generations of carbonate mixed together have a lower-resolution paleoecologic record than soil profiles repeatedly buried. (4) At the rhizosphere scale (lm2 to cm2), carbonate formed on roots lack the 14 17 enrichment observed at broader scales, revealing different fractionation processes at different scales. A multi-scale approach in dealing with d13C in pedogenic carbonate will increase the accuracy of paleoecologic interpretations and understanding of soil geomorphic climatic interactions that affect boundaries between C4 and C3 vegetation.

54 ENVIRONMENTAL SCIENCES↗

Recorded Information Management Records Move Project

Throughout the history of Sandia National Laboratories, both federal and corporate records have been stored in 12 structures in remote areas of the lab, none of which are compliant storage facilities under federal regulations. Upon inspection by the National Archives and Records Administration (NARA), findings were levied against Sandia along with recommendations on correcting the issues. The RM Department anticipated over 38,000 boxes of legacy records in Sandia’s current holdings. The current storage areas present an abundance of unknown issues and risks associated with the move project. Along with the large amount of records, and media types, this project faces issues with over 50 years of ever changing filing systems and human error pertaining to data entry, boxes being processed and destroyed. This document presents the final data and results pertaining to the Recorded Information Management Department corrective actions in a well laid out project plan that accommodated safety, security, environmental concerns and of course the records.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Long-term surveillance and maintenance records: challenges inherent to managing electronic records - 15165

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) is an integral part of DOE's strategy to ensure that legacy liabilities of former nuclear weapons production sites are properly managed following the completion of environmental cleanup activities. Records management is crucial to the protection of health, environmental, and legal interests of the Department and the public. LM is responsible for preserving long-term surveillance and maintenance (LTS and M) records in performance of its mission. Electronic records (e-records) documenting LTS and M activities are becoming more prevalent. Managing e-records creates new challenges in maintaining their accessibility and readability for the duration of their use. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distributed Order Recording Techniques for Efficient Record-and-Replay of Multi-threaded Programs

After all these years and all these other shared memory programming frameworks, OpenMP is still the most popular one. However, its greater levels of non-deterministic execution makes debugging and testing more challenging. The ability to record and deterministically replay the program execution is key to address this challenge. However, scalably replaying OpenMP programs is still an unresolved problem. In this paper, we propose two novel techniques that use Distributed Clock (DC) and Distributed Epoch (DE) recording schemes to eliminate excessive thread synchronization for OpenMP record and replay. Our evaluation on representative HPC applications with ReOMP, which we used to realize DC and DE recording, shows that our approach is 2-5x more efficient than traditional approaches that synchronize on every shared-memory access. Furthermore, we demonstrate that our approach can be easily combined with MPI-level replay tools to replay non-trivial MPI+OpenMP applications. We achieve this by integrating ReOMP into ReMPI, an existing scalable MPI record-and-replay tool, with only a small MPI-scale-independent runtime overhead.

Fu, Xiang↗

Single-shot optical recording with sub-picosecond resolution spans record nanosecond lengths

With the advent of electronics, oscilloscopes and photodiodes are now routinely capable of measuring events well below nanosecond resolution. However, these electronic instruments do not currently measure events below 10 ps resolution. From Walden’s observation that there is an engineering tradeoff between electronic bit depth and temporal resolution in analog-to-digital converters, this technique is projected to have extremely poor fidelity if it is extended to record single events with picosecond resolution. While this constraint may be circumvented with extensive signal averaging or other multiple measurements approaches, rare events and nonrepetitive events cannot be observed with this technique. Techniques capable of measuring information in a single shot are often required. There is a general lack of available technologies that are easily scalable to long records with sub-picosecond resolution, and are simultaneously versatile in wavelength of operation. Since it is difficult to scale electronic methods to shorter resolutions, we instead aim to scale optical methods to longer records. Demonstrated optical recording methods that have achieved 1 ps resolution and long recording lengths rely on either time scaling to slow down the temporal information or, like Wien, perform time-to-space mapping so that fast events may be captured with a conventional camera.

47 OTHER INSTRUMENTATION↗

Single-shot optical recorder with sub-picosecond resolution and scalable record length on a semiconductor wafer

In this study, we demonstrate a novel, single-shot recording technology for transient optical signals. A resolution of 0.4 ps over a record length of 54 ps was demonstrated. Here, a pump pulse crossing through a signal samples a diagonal “slice” of space–time, enabling a camera to record spatially the time content of the signal. Unlike related X (2) -based cross-correlation techniques, here the signal is sampled through optically pumped carriers that modify the refractive index of a silicon wafer. Surrounding the wafer with birefringent retarders enables two time-staggered, orthogonally polarized signal copies to probe the wafer. Recombining the copies at a final crossed polarizer destructively interferes with them, except during the brief stagger window, where a differential phase shift is incurred. This enables the integrating response of the rapidly excited but persistent carriers to be optically differentiated. Lastly, this sampling mechanism has several advantages that enable scaling to long record lengths, including making use of large, inexpensive semiconductor wafers, eliminating the need for phase matching, broad insensitivity to the spectral and angular properties of the pump, and overall hardware simplicity.

42 ENGINEERING↗