Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference architecture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SLIA Reference Architecture Models

The SLIA Reference Architecture Models project, sponsored by the DOE CESER Energy CyberSense Program (Oct 2024–Sep 2025), advanced LLNL’s PySCES simulation tool to better support CyTRICS Prioritization and Initial Risk Assessment (PIRA) reference architectures. Key achievements include enhancements to the PySCES transmission substation facility model, expanded asset coverage, and enhancements to the PySCES code base. Software improvements reduced code complexity, migrated PySCES to Python version 3.11, introduced an object-oriented design, and added a schema database for easier updates and validation. New features support device criticality assessments and a more precise parametric simulation mode. Remaining gaps include model validation, workflow limitations, Monte Carlo convergence issues, full device criticality metric implementation, model fidelity, and general software improvements. Continued development is recommended to address these gaps and fully align PySCES with CyTRICS PIRA requirements.

97 MATHEMATICS AND COMPUTING↗

Land-Based Wind Reference Architecture

This report describes a summary and the final deliverables for the Wind Reference Architecture project funded by the Department of Energy's (DOE) Wind Energy Technology Office (WETO). The project objective was to further refine the reference architecture of the existing wind power plant reference architecture developed by Idaho National Laboratory (INL) and Sandia National Laboratories (SNL) by expanding the wind turbine generator (WTG) into a separate individual wind turbine reference architecture. Additional details regarding the wind turbine system and how it integrates with a wind power plant were researched and reflected in the reference architecture. This addition is important because it allows researchers to understand the components and devices in a wind turbine, how they function and how a wind turbine integrates into a wind power plant to be able to perform cybersecurity evaluations on the system. The communication and control systems were the focus while developing this reference architecture to understand the cybersecurity posture of a wind turbine and power plant. The information technology (IT) and operational technology (OT) systems perspective are integral in helping improve the cybersecurity posture by creating a starting point to study how wind energy can be safely designed and deployed in our power grid from an integrated systems standpoint. A holistic wind power plant and turbine reference architecture and simulation was developed and made open-sourced for further research efforts.

17 WIND ENERGY↗

Reference Architecture Discussion [Slides]

NREL is developing reference architectures - industry-validated and verified models - to provide a common operational view and emulation environment for analyzing risk to the energy sector. In this presentation, we overview our work in developing these architectures.

97 MATHEMATICS AND COMPUTING↗

The Concept and Role of Reference Architectures In NIF LRU Refurbishment Factories within LLNL

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) operates one of the most advanced laser systems in the world, relying on a vast number of optical components and Line Replaceable Units (LRUs) to maintain its functionality. Over time, these components degrade due to operational wear, necessitating refurbishment to sustain performance. However, many NIF LRU refurbishment factories have been “mothballed” or suffer from aging infrastructure, inconsistent work flows, and inefficiencies due to different approaches to production control and management. This paper explores the concept of reference architecture as a standardized framework to guide the redevelopment and restructuring of NIF LRU refurbishment factories. By establishing a common reference architecture, the refurbishment process can achieve reduced inefficiencies, produce quality products, and enhanced coordination across factories. This paper evaluates existing reference architectures, particularly those that integrate technical architecture, business architecture, customer context perspectives, and proposes tailored reference architecture for NIF LRU refurbishment factories.

42 ENGINEERING↗

A Functional Reference Architecture and Assessment Thereof for the National Ignition Facility Industrial Controls Systems

The Industrial Control System (ICS) at the National Ignition Facility (NIF) has an effective, well-established architecture based off a conventional cyclical software paradigm focused on maintainability and the identification of issues. This architecture exhibits scalability in ensuring expansions of the system conform to the existing architecture, modularity enough to allow relatively easy integrations of such expansions and works as a successful tool to introduce control system engineers new to the NIF ICS to the structure of the system at each layer. This architecture, like most software architectures, is object-oriented, lending itself to ease of understanding by control systems engineers and software engineers familiar with an object-oriented perspective. There are occasions, however, where engineers of other disciplines require insight into the functionality and structure of the ICS for the purposes of understanding fundamentally how their own system is or will be governed by the ICS, without the need for the details of operation of the ICS or the object-oriented view. For this reason, a functional architecture of the ICS could be a potent tool for communicating this insight. Even more powerful, a generalization of this proposed functional ICS architecture in the form of a National Ignition Facility and Photon Science (NIF & PS) Industrial Controls Reference Architecture could communicate this insight not just to systems governed by the ICS in the NIF proper, but across entirety of the NIF & PS Principal Associate Directorate (PAD), anywhere an instance of the ICS architecture is present, such as the approximately 40 “small labs” distributed across the directorate. Such a tool will provide an alternative means of understanding the implementation of these control systems, conducive to a larger variety of engineering and scientific disciplines.

42 ENGINEERING↗

IoT Intrusion Detection Taxonomy, Reference Architecture, and Analyses

This paper surveys the deep learning (DL) approaches for intrusion-detection systems (IDSs) in Internet of Things (IoT) and the associated datasets toward identifying gaps, weaknesses, and a neutral reference architecture. A comparative study of IDSs is provided, with a review of anomaly-based IDSs on DL approaches, which include supervised, unsupervised, and hybrid methods. All techniques in these three categories have essentially been used in IoT environments. To date, only a few have been used in the anomaly-based IDS for IoT. For each of these anomaly-based IDSs, the implementation of the four categories of feature(s) extraction, classification, prediction, and regression were evaluated. We studied important performance metrics and benchmark detection rates, including the requisite efficiency of the various methods. Four machine learning algorithms were evaluated for classification purposes: Logistic Regression (LR), Support Vector Machine (SVM), Decision Tree (DT), and an Artificial Neural Network (ANN). Therefore, we compared each via the Receiver Operating Characteristic (ROC) curve. The study model exhibits promising outcomes for all classes of attacks. The scope of our analysis examines attacks targeting the IoT ecosystem using empirically based, simulation-generated datasets (namely the Bot-IoT and the IoTID20 datasets).

97 MATHEMATICS AND COMPUTING↗

Software-defined Networking for Energy Delivery Systems (SDN4EDS): An Architectural Blueprint (Final Report)

This is the initial version of a reference for suppliers and energy companies of all sizes to deploy networks based on software-defined networking technology (SDN) to improve reliability, reduce cyber security attack surface, and facilitate mitigation of adversarial behavior. It is a living document and will progress over the life cycle of the Software-Defined Networking for Energy Delivery Systems (SDN4EDS) project. Version 2 of this report provides information on the Red Team tabletop assessment performed against the initial reference architecture. Version 3 of this report updates the reference architecture with lessons learned from the Red Team tabletop assessment, as well as provides additional details for the use cases. It also provides information on the decision process that could be used by an organization when considering deploying SDN in their environment. The final version of this report consolidates all the interim reports generated by the project into a final report. It also draws from PNNL’s experience in deploying SDN to make recommendations on how SDN could be deployed in a utility environment, and provides rationale for those decisions allowing individual utilities to make risk-based and knowledge-based decisions on how to best deploy SDN in their own environment

97 MATHEMATICS AND COMPUTING↗

Software-defined Networking for Energy Delivery Systems (SDN4EDS): An Architectural Blueprint (Final Summary Report)

This is the initial version of a reference for suppliers and energy companies of all sizes to deploy networks based on software-defined networking technology (SDN) to improve reliability, reduce cyber security attack surface, and facilitate mitigation of adversarial behavior. It is a living document and will progress over the life cycle of the Software-Defined Networking for Energy Delivery Systems (SDN4EDS) project. Version 2 of this report provides information on the Red Team tabletop assessment performed against the initial reference architecture. Version 3 of this report updates the reference architecture with lessons learned from the Red Team tabletop assessment, as well as provides additional details for the use cases. It also provides information on the decision process that could be used by an organization when considering deploying SDN in their environment. The final version of this report consolidates all the interim reports generated by the project into a final report. It also draws from PNNL’s experience in deploying SDN to make recommendations on how SDN could be deployed in a utility environment, and provides rationale for those decisions allowing individual utilities to make risk-based and knowledge-based decisions on how to best deploy SDN in their own environment. This summary report provides a higher-level overview of the project reports. Readers interested in additional detail, including results of the Red Team assessments and the final configuration, are encouraged to read the full final report.

97 MATHEMATICS AND COMPUTING↗

RESCue Model (RESCue Experiment and Model) [SWR-24-84]

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of transmission-connected hybrid renewable energy systems, consisting of a combination of wind, solar, and/or energy storage equipment, against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. The development of hybrid reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. The research thrusts for the project included (i) development of hybrid reference architectures and (ii) a cyber-resilient design framework for hybrid energy systems. The reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. A demonstration experiment was developed for one of the architectures using NREL's Cyber Range resources. This experiment configuration, deployable using open-source tools, is provided here in this repository. Additional models were developed for the wind and solar architectures as well, however the configurations for only the Energy Storage scenario are provided here: https://www.nrel.gov/docs/fy24osti/89921.pdf

Hasandka, Adarsh↗

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

NREL Stratus - Enabling Workflows to Fuse Data Streams, Modeling, Simulation, and Machine Learning

Integrating cloud services into advanced computing facilities provides significant new capabilities over focusing solely on traditional high performance computing (HPC) workloads. This brings complementary capabilities as well as enabling new focused roles for HPC. They are especially potent for workflows that fuse data streams, modeling and simulation ('modsim') and machine learning. A key challenge to adopting a hybrid edge-cloud-HPC model is to align optimal capability, data, and user intent on the right resources for each step in a workflow.?The NREL Stratus service provides a basis for this: Stratus layers capabilities needed to make?cloud services accessible to a lab-based scientific community on commercial offerings, and; currently supports upwards of 200 projects ranging from IOT integration to traditional modeling and simulation. This provides a real-world inventory of scientific workflow elements. A growing knowledge base enables placing these elements appropriately between the edge, cloud, and traditional HPC. This paper outlines a vision via reference architecture and the application of that architecture in a typical workflow highlighting multiple components: sensor data intake, cleaning and transforming (edge/cloud suitable); generation of synthetic data through modsim, computationally heavy ML training and hyperparameter optimization (HPC suitable), and; inference and deployment (cloud ideal). Every step in such a workflow involves a cost-benefit analysis regarding the data movement, computational efficiency, availability, latency, and resource capabilities. The reference architecture and examples outlined allow for understanding new opportunities in the context of emerging workflows that combine IOT, cloud, and HPC to bolster scientific productivity.

AI↗

28 NREL Stratus - Enabling Workflows to Fuse Data Streams, Modeling, Simulation, and Machine Learning: Preprint

Integrating cloud services into advanced computing facilities provides significant new capabilities over focusing solely on traditional high performance computing (HPC) workloads. This brings complementary capabilities as well as enabling new focused roles for HPC. They are especially potent for workflows that fuse data streams, modeling and simulation ('modsim') and machine learning. A key challenge to adopting a hybrid edge-cloud-HPC model is to align optimal capability, data, and user intent on the right resources for each step in a workflow.?The NREL Stratus service provides a basis for this: Stratus layers capabilities needed to make?cloud services accessible to a lab-based scientific community on commercial offerings, and; currently supports upwards of 200 projects ranging from IOT integration to traditional modeling and simulation. This provides a real-world inventory of scientific workflow elements. A growing knowledge base enables placing these elements appropriately between the edge, cloud, and traditional HPC. This paper outlines a vision via reference architecture and the application of that architecture in a typical workflow highlighting multiple components: sensor data intake, cleaning and transforming (edge/cloud suitable); generation of synthetic data through modsim, computationally heavy ML training and hyperparameter optimization (HPC suitable), and; inference and deployment (cloud ideal). Every step in such a workflow involves a cost-benefit analysis regarding the data movement, computational efficiency, availability, latency, and resource capabilities. The reference architecture and examples outlined allow for understanding new opportunities in the context of emerging workflows that combine IOT, cloud, and HPC to bolster scientific productivity.

AI↗

CReST-VCT System Integration Framework

In this paper, we propose a system integration framework for deploying the Coordinated Real-time Sub-Transmission Volt-var Control Tool (CReST VCT) functionality between the transmission system, the distribution system, and DERs. This represents one possible set of design choices to implement the coordinated optimization capabilities in an operating environment. The framework provides the following: An architectural reference model that describes how the CReST VCT solution maps into a broader grid architecture that accommodates and enables higher levels of DER penetration and utilization: A system integration reference model that defines a possible allocation of CReST VCT functionality within a utility’s operational environment. This includes one possible system design approach for allocation of functionality within software and protocol selections across the various interfaces; A list of potential performance and security issues that should be considered during an implementation. This framework does not represent a specific implementation of the CReST VCT algorithm or integration into a specific utility environment. It is intended to serve as a reference for those who plan to implement such a solution into their environment. The general model provided by the framework can be tailored to a specific environment based on its specific constraints and requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Load Shedding as Part of Primary Frequency Response To Support Networked Microgrid Operations

Global changes in the deployment of distributed energy resources, control and communications technologies, business models, and regulatory policy are increasing the operational options for future distribution systems. One such option is the coordinated operation of distributed resources to form microgrids and networks of microgrids to support traditional bulk power systems during normal operations and critical end-use loads during outages. While individual standalone microgrids have been extensively studied and deployed, the coordinated operation of networked microgrids is operationally more challenging due to the dynamic boundaries and changing mix of generation resources. Here, this paper presents a method of using a distributed control architecture to support primary frequency response in networked microgrids operations. The support of primary frequency response is accomplished using the Open Field Message Bus reference architecture and Grid Friendly Appliance controllers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Evaluation of Next-Generation Grid Automation and Controls with High PV Penetration

This paper presents a hardware-in-the-loop (BIL) simulation to evaluate the performance of an advanced grid automation architecture, referred to as data-enhanced hierarchical control (DEHC), in achieving voltage regulation and conservation voltage reduction (CVR) in distribution networks with very high photovoltaic (PV) generation. This architecture comprises an advanced distribution management system (ADMS), a distributed energy resource management system (DERMS), and grid-edge devices working synergistically to provide the grid benefits. The HIL setup used for the evaluation includes ADMS, DERMS, and grid-edge devices. The DEHC performance is evaluated in two representative scenarios considering loose and tight constraints of the power factor at the substation. The results show that the DEHC architecture is effective in achieving voltage regulation and CVR and thus enables the grid integration of high levels of PV generation.

ADMS↗

Architecture Design for Remote Operation of Microreactors: Poster

The nuclear sector is pursuing a number of advanced reactor concepts, one of which is the microreactor, an advanced reactor characterized by a power output of less than 20 MWth. These reactors are intended for use in applications where traditional power solutions are economically or logistically impractical. One key feature required for the successful deployment of microreactors is a remote operation capability, which can dramatically cut staffing expenses by eliminating the need for licensed operators to be present at the site of each reactor and instead concentrate in a centrally located operations center. In moving to a remote operations framework for nuclear reactors, the number of potential attack surfaces for a cyber adversary looking to cause harm or disruption increases. Therefore, a robust cybersecurity architecture is required to mitigate these potential vulnerabilities. This paper explores the functional infrastructure, security, and communication requirements to adapt remote operations to nuclear applications. It then presents a reference architecture for remote operations of microreactors that applies best practices in cybersecurity and remote communications in the context of a digital twin remote operation system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

5G Zero Trust Architecture: A Testable and Phased Approach

With the emphasis being placed on Zero Trust Architecture in technology and by Executive Order (Executive Order on Improving the Nation’s Cybersecurity ), an investigation was performed as to the feasibility of implementing this approach into 5G. Reference documents include NIST Special Publication 800-207 and Department of Defense (DoD) Zero Trust Reference Architecture , and these provided guidance as to the overall approach. Progress is being made within 5G to address the lack of Zero Trust Architecture; a June 2021 DoD press release indicated that “The prototype 5G network is built on the next generation of Open Radio Network standards and designed to comply with DOD specifications for zero-trust architecture for native security and secure connectivity with other networks.”

5G↗

Advanced Module Architecture for Reduced Costs, High Durability and Significantly Improved Manufacturability (Final Report)

This project demonstrated a new module architecture (referred to herein as Glass/Glass) using silicone edge seals and an interlayer polymer that reduces manufacturing costs, significantly streamlines manufacturing processes, and reduces cap-ex costs while improving module reliability. A prototype manufacturing process to fabricate this new module architecture was demonstrated with a significantly improved process cycle time for the lamination step from the current industry standard of 13.5 minutes to approximately 30 seconds for each of the individual edge seal and internal polymer application steps. Samples are fabricated, strenuously stressed, and characterized to quantify the cost benefits, hardware capacities and accelerated stress performance of the new architecture. These results are being compared to a standard, laminated baseline architecture using a Glass/EVA/Glass or Glass/Thermoplastic/Glass design that traditionally has high moisture vapor transmission rates (MVTR).

14 SOLAR ENERGY↗