Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cathodic Decomposition Electrodes as Standard Reference Electrodes for Molten Salts: Example of the Lithium Eutectic Electrode for the LiCl-KCl Eutectic

Alternatives to the widely-used standard anodic decomposition reference electrodes in molten salts are necessary to enable more easily reproduced thermochemical and electrochemical data in molten salt electrolytes. The class of standard reference electrodes called cathodic decomposition electrodes (CDEs) are easily constructed and can be used to make thermochemical measurements in molten salts more directly compared to anodic decomposition electrodes. The lithium eutectic electrode (LEE) was chosen as a sample test case for validation and was applied to thermochemical measurements of electroactive species in molten LiCl-KCl eutectic. Transient measurements were made to measure the Li + /Li reduction potential at zero current in pure LiCl-KCl eutectic relative to a Li-alloy reference electrode to validate the reference potential of the LEE. Literature-reported electromotive force measurements against Li-alloy reference electrodes were used to generate a relationship between the LEE and the standard chlorine electrode and this relationship was used to evaluate measured and reported formal potential measurements for the LiCl-KCl-GdCl 3 system. This work demonstrates the general framework for defining CDEs for any molten salt system and a method for calibrating external reference electrodes against a CDE standard reference electrode, improving the ease of obtaining thermochemical and electrochemical measurements in any molten salt system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Reference Electrodes in Anion-Exchange-Membrane Electrolyzers: Impact of Stainless-Steel Gas-Diffusion Layers and Internal Mechanical Pressure

Alkaline-membrane electrolyzers operating in pure water might provide scalable low-cost H 2 production but currently lag in performance and durability compared to commercial technologies. Typically, membrane–electrode assemblies (MEAs) are optimized in electrolyzers by changing one parameter at a time and assessing the resulting system performance via two-electrode polarization and impedance measurements. These approaches are limited in their ability to assign performance changes and durability to specific electrodes or processes. We integrate a reference electrode with the MEA to separate anode and cathode responses in both polarization and impedance measurements. Here we illustrate the power of the approach by showing how the fiber diameter of stainless-steel gas-diffusion layers (GDLs) affects performance solely at the anode, while changing the thickness of the cathode GDL simultaneously affects the performance of the anode and cathode due to changes in internal pressure from mechanical compression. This finding was obscured in conventional two-electrode measurements. The work thus guides both high-performance alkaline-membrane water-electrolyzer development and illustrates a useful strategy to study structure–activity relationships in the MEA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of a U(IV)/U(III) Thermodynamic Reference Electrode for High-Temperature Molten Fluoride Salts

While thermodynamic reference electrodes with known and stable potentials are common in traditional aqueous systems, the high temperature and corrosive environment of a molten fluoride salt makes achieving long term stability with a thermodynamic reference electrode challenging, especially at temperatures of 600°C or higher. In this work, a thermodynamic reference electrode consisting of U(IV)/U(III) in a boron nitride compartment was evaluated for use in FLiBe at temperatures ≥ 600°C. FLiBe used in the study was purified by AlphaTech's proprietary process and characterized by ICP-MS and square wave voltammetry. The free oxide concentration was <2 ppm. Using the purified FLiBe, the U(IV)/U(III) thermodynamic reference electrode was shown to provide a stable, well-defined, and reproducible potential for more than 600+ hours of use in different tests. Moreover, the thermodynamic reference electrode showed a consistent potential with no signs of failure, even after being cooled between tests and then reheated for reuse. Thus, the U(IV)/U(III) reference electrode is suitable for use in rigorous electrochemical studies in molten fluoride salts. As a result, it may be useful as a common standard, facilitating the advancement of nuclear applications such as isotope separation or online monitoring of reactor systems through improved certainty in the measurement of thermodynamic potentials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Robust Reference Electrode in Aggressive Chemical and Radiation Environments in the Hanford Waste Tanks

The Hanford site stores more than 200 million liters of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground carbon-steel storage tanks, separated between 149 single shell tanks (SSTs) and 28 double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The tanks will need to remain in-service far beyond the initial 40-year design life, and effective corrosion control practices must remain in force to extend the tanks’ lifespans. This effort includes direct measurements of corrosion rate (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements and open circuit potential measurements). The Hanford site began monitoring the corrosion potential in select DSTs in 2008. Of the 45 reference electrodes that have been installed, 29 have failed and 6 others provided unreliable results. DOE-EM is supporting a 3-year program to develop a chemical and radiation resistant reference electrode for application in the Hanford tanks. The first year of the program focused on understanding the failure mechanism for the reference electrodes and identification of candidate construction materials that would mitigate degradation of the electrodes in the waste environment. During the second year of the program, the objectives were to: 1) test candidate materials under simulated waste conditions, 2) design components that will extend the service life of the electrode, 3) fabricate materials for prototype reference electrodes, and 4) assemble prototype reference electrodes for accelerated testing. The reference electrode is constructed of four principal parts: 1) junction, 2) casing, 3) inner chamber backfill materials, and 4) the sensing wire. Principally, improvements of the junction, casing, and inner chamber backfill materials are being pursued. The junction material at the interface between the waste and the inner chamber of the reference electrode was identified as a critical component in the failure of the reference electrodes. Nine candidate replacement junction materials were tested under simulated waste conditions to evaluate permeation rate. These materials included a variety of polymeric and ceramic materials, some of which were 3-D printed. Thus far, porous polyvinylidene fluoride materials have performed satisfactorily and are being considered for prototype development. The commercial electrode casing materials in general have performed well. Additionally, 3-D printing of chemically and mechanically stable materials is being investigated as a means for further improvement in fabrication consistency. SRNL has also investigated altering the reference electrode design to extend the service life. The new design of the interior of the reference electrode casing creates a longer, more tortuous path between the junction material and the electrode sensing wire. A finite element model was used to optimize the design without adversely impacting the circuit resistance of the electrode during the measurements, thus preserving the measurement accuracy while enhancing the service life. The inner chamber back fill materials are also critical to the performance of the reference electrode. Materials that are resistant to intruding tank waste and provide a conductive path to the sensing wire were investigated. Gel and powder materials that are interspersed with a conductive chloride bearing material were tested for their influence on diffusion and electrode resistance. All the investigated materials and components will be assembled, with collaboration from commercial vendors, to fabricate the initial prototypes. Accelerated testing of the prototypes will be initiated in Year 2 of the program and will be completed in Year 3. A recommendation on the materials of construction and the design of the new robust reference electrode will be presented to the Hanford tank farm facility.

Sykes, Kiana [Savannah River National Laboratory (↗

Reference electrode for electrochemical measurements at high temperatures

A reference electrode which is stable over a wide range of temperatures, pressures and chemical conditions is provided. The subject reference electrode according to the present invention comprises a tubular enclosure composed of quartz having a distal, closed end and a proximal, open end. An insulating ceramic rod is seemingly connected to the opening in the closed distal end of the enclosure to form micro-cracks between the ceramic rod and the quartz enclosure (called a cracked junction, CJ). The CJ gives a very tortuous path for ion conduction from inside the reference electrode (RE) to a working electrode (WE). Inside the tubular enclosure is an electrical lead (e.g., a silver wire) disposed in an electrolyte comprising a mixture of alkaline metal salts (e.g., AgCl and KCl), extending from the electrolyte upward through a sealing means at the proximal end of the quartz enclosure.

Gervasio, Dominic Francis↗

Long-Term Stability of Mullite and Magnesia-encased Ag|Ag + Reference Electrodes in Molten MgCl 2 -KCl-NaCl

In this study, the stability of Ag|Ag + molten chloride reference electrodes was studied using mullite and magnesia tubes as reference electrode membrane materials in molten MgCl 2 -KCl-NaCl for continuous immersion up to 31 d. Two electrochemical methods were used to characterize the long-term performance of the reference electrodes at 500 °C in an inert atmosphere using a Mg rod as the working electrode: open circuit potential (OCP) and onset of Mg(II) reduction as measured by cyclic voltammetry (CV). There was only a 3% difference between the average OCP measured versus the mullite and MgO reference electrodes. Potential drift was higher for mullite (−1.34 mV d −1 ) than MgO (0.22 mV d −1 ). But both drift rates were very low compared to the OCP data standard deviation, indicating that no significant drift was measured for us to 31 d.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ni/NiCI(2) Reference Electrodes For Na/NiCI(2) Cells

Reference electrodes made of nickel cores with surface layers of nickel chloride proposed for use in molten sodium tetracholoroaluminate electrolytes in experimental sodium/nickel chloride electrochemical cells. These and other sodium/metal chloride cells investigated for use in several applications, including powering electric vehicles and leveling loads in power-distribution systems. Offers potential advantages of greater durability, greater stability and reproducibility of electrochemical potentials, less sensitivity of electrochemical potentials to variations in compositions of electrolytes, and greater compatibility with cathodes, made of nickel chloride.

Bugga, Ratnakumar↗

Simply Fabricatable Reference Electrode for Studying Li Metal Interfaces Operando

Reference electrodes are essential for studying Li metal interfaces, yet their integration into coin cells remains challenging due to geometric constraints and assembly complexity. Here, we present a simple three-electrode coin cell design in which a thin Cu film is evaporated directly onto a trilayer PP/PE/PP separator, forming a conductive and flexible in situ current collector. The microporous Cu preserves separator porosity and pressure uniformity, avoiding artifacts introduced by wire- or mesh-type references. It is easily activated by Li plating and provides stable potentials for over 10 days in ether-based electrolytes without affecting Coulombic efficiency (>99%) or Li deposition morphology. Operando measurements using this design reveal electrode-specific impedance evolution and voltage responses otherwise obscured in two-electrode setups, uncovering a correlation between the SEI resistance and electrolyte ionic conductivity. This microporous Cu reference electrode offers a robust and accessible platform for characterizing reactive interfaces under realistic cycling conditions.

Sacci, Robert [ORNL] (ORCID:0000000200735221)↗

In Situ Reliability Investigation of All-Vanadium Redox Flow Batteries by a Stable Reference Electrode

Redox flow batteries (RFBs) have been studied over the past several decades as a promising candidate for stationary energy storage applications. It is therefore important to understand the reliability of RFBs and the mechanisms that cause degradation with time. Contributions from individual electrodes (cathode or anode) are difficult to separate especially for long-term cycle testing, due to the lack of a stable reference electrode. In our work, the reliability and degradation mechanisms of an all-vanadium RFB were investigated by a stable reference electrode based on the dynamic hydrogen electrode (DHE). With factor exploration and design optimization, the newly developed DHE reference electrode demonstrated high accuracy and long-term stability that enables in-situ monitoring of individual electrode signals (potentials and impedances) over hundreds of cycles in a vanadium RFB. This approach enables the full cell degradation to be separated and the degradation attributed to contributions from the cathode and anode. The cathode and anode were found to play quite different roles in the increase in overpotential of the vanadium RFB during long-term cycling. The anode reaction limited both the charge and discharge capacity over 100 cycles. In addition, the negative side also appeared to be the rate limiting factor throughout cycling as determined by EIS measurement. The cathode contributed to the performance degradation as cycling exceeded 50 cycles.

Huang, Qian↗

Reference electrode and electrochemical monitoring system

A reference electrode includes a metal body, a lead disposed within the metal body, an insulator disposed between the lead and the metal body, the insulator including a ceramic material, and a porous metal chamber coupled to the metal body, the lead extending into the porous metal chamber. The porous metal chamber is configured to maintain an electrolyte solution within the porous metal chamber to establish a redox couple with the lead.

Burak, Adam↗

Long-Term Performance of Reference Electrodes in Alkaline Radioactive Waste Storage Environments

Accurate measurements of corrosion potential are important for assessing the likelihood of internal localized corrosion and stress corrosion cracking of carbon steel tanks used for storing radioactive wastes. Reference electrodes in underground radioactive waste storage tanks are challenging to deploy, and more difficult to extract and replace frequently due to radiological exposure and disposal constraints. Hence, electrodes that exhibit stable performance over long periods of immersion in these waste environments are desirable. The present study evaluates the stability of reference electrodes used in radioactive waste storage tanks over a much longer period than previously studied. Long-term tests on Ag/AgCl and Hg/HgO reference electrodes were performed in nonradioactive simulants formulated from wastes stored at the Hanford site. Electrode degradation, which was studied by various in situ and ex situ evaluation techniques, was correlated to changes in electrode fill chemistry from waste intrusion via the porous frit junction. An intentional contamination study was performed to better understand and predict contamination effects on electrode potential drift.

Materials Science↗

Stability of a Ni/NiF 2 Reference Electrode with a Metallic Membrane for Use in Molten Fluoride Salts

In this study, an experimental high-temperature fluoride salt reference electrode (RE) developed by HiFunda LLC was tested in molten FLiNaK at 550 °C. The high-temperature reference electrode (HTRE), based on the Ni/NiF 2 redox couple, was tested over a period of 13 d for short-term stability, long-term stability, and electrochemical analysis capabilities. The HTRE was tested using open circuit potentiometry (OCP), cyclic voltammetry (CV), square wave voltammetry (SWV), and electrochemical impedance spectroscopy (EIS). The HTRE reference potential was measured against changes in salt composition by increasing FeF 2 concentrations in the melt across six additions from 0 to 0.1 mol% FeF 2 . The long-term stability of the electrode was then tested over ten days at a constant composition of 0.1 mol% FeF 2 . OCP, SWV, and CV were used to calculate an average potential drift between 7–10 mV per day. Using CV and SWV, the number of electrons transferred for iron reduction and the diffusion coefficient of Fe 2+ were measured.

Electrochemistry↗

Long-Term Performance of Ag/AgCl Reference Electrodes for Corrosion Potential Monitoring in Radioactive Tank Waste at the Hanford Site

This work studied the exposure effects of radioactive tank waste on the long-term performance of single junction Ag/AgCl reference electrodes for corrosion potential monitoring at the Hanford Site. Electrodes from three manufacturers with very different designs were studied using open-circuit potential and electrochemical impedance measurements in radioactive tank waste. Post-test analyses were conducted on some failed electrodes using destructive and nondestructive techniques. The intrusion of the aggressive and radioactive chemicals in tank waste through the porous frit materials was the primary mechanism that led to the clogging of frit, physical and chemical degradation of AgCl bonded to Ag wire, and alteration of the internal electrolyte. Radiolytic chemical species such as H2O2 and HNO3 may have also induced the degradation of the Ag wire. The extent of electrode degradation and failure probability highly depended on the electrode design and environmental conditions. Chemicals in tank waste had stronger effects than radiation on the long-term performance of the Ag/AgCl reference electrodes.

Materials Science↗

Potentiodynamic Polarization of Pure Metals and Alloys in Molten LiF-NaF-KF (FLiNaK) Using the K/K + Dynamic Reference Electrode

The potentiodynamic polarization method using the K/K + dynamic reference electrode was used to understand the corrosion behavior of Ni, Fe, Cr, the Ni-20Cr binary alloy, and 316L stainless steel in molten 46.5LiF-11.5NaF-42KF (FLiNaK, composition in mol %) salt at 700 °C. Exposure of the materials without an applied potential revealed that Ni and Fe were stable in FLiNaK, but Cr was dissolved rapidly. The apparent redox potentials of each material with respect to the K/K + redox couple are compared to gain insight into how the applied potential relates to the dominant corrosion mechanism for each alloy. Furthermore, the polarized pure metals experienced uniform surface recession while corrosion in the alloys resulted in preferential elemental dissolution depending on the applied potential with respect to the K/K + reference reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigating Electrochemical Impedance Spectroscopy Artifacts in PEMWE Reference Electrode Measurements

This study investigates strategies to improve the quality of electrochemical impedance spectroscopy (EIS) measurements using reference electrodes (RE) in proton exchange membrane water electrolyzers (PEMWE). We demonstrate that adding a low impedance wire in parallel to the RE significantly enhances signal accuracy, especially at high frequencies. Additionally, we identify electrical pad heaters as a source of measurement noise. EIS measurements fulfilling Kramers–Kronig validity criteria were only achieved in their absence. These insights advance the diagnostic capabilities of REs in water electrolyzers and support more reliable, spatially resolved analysis of electrochemical losses within the cell.

08 HYDROGEN↗

Impedance studies of Ni/Cd and Ni/H2 cells using the cell case as a reference electrode

Impedance measurements have been made on several Ni/Cd and Ni/H2 flightweight cells using the case as a reference electrode. For these measurements the voltage of the case with respect to the anode or cathode is unimportant provided that it remains stable during the measurement of the impedance. In the cells measured so far, the voltages of the cell cases with respect to the individual electrodes differ from cell to cell even at the same overall cell voltage, but they remains stable with time. The measurements can thus be used to separate the cell impedance into the contributions of each electrode, allowing improved diagnosis of cell problems.

Reid, Margaret A.↗

Solvent independent reference electrodes for use with non-aqueous electrolytes

The present disclosure relates to a method for forming a reference electrode for use in electrochemical testing applications. The method may involve positioning a porous frit against one end of a hollow tube, and securing the frit and the hollow tube to one another to form an assembly. The method may further involve forming a silver sulfide coating on a silver wire to produce a silver sulfide coated silver wire. The method may further involve filling the hollow tube with a non-aqueous solution, and inserting at least a portion of the silver sulfide coated silver wire into the non-aqueous solution in the hollow tube.

Horwood, Corie↗