Spread Spectrum Time-Domain Reflectometry and Frequency Domain Reflectometry to Detect Shielded and Unshielded Cable Moisture Exposure

This work evaluates the feasibility to extend spread spectrum time-domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) electrical cable testing to characterize whether an electrical cable is submerged in water or not and where it may be submerged. Using PNNL’s ARENA cable and motor test bed, shielded and non-shielded electrical cables were evaluated using SSTDR and FDR methods to detect and locate electrical cable exposure to water. Both SSTDR and FDR showed the presence of water with a non-shielded cable. Moisture was only detectable with the shielded cable if the insulation was damaged.

reflectometry cable test, cable moisture detection↗

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nondestructive Evaluation (NDE) of Cable Moisture Exposure using Frequency Domain Reflectometry (FDR)

This Pacific Northwest National Laboratory (PNNL) milestone report assesses the capability of frequency domain reflectometry (FDR) to determine electrical cable submergence using PNNL’s Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable/motor test bed. This work includes a review of relevant literature as well as experimental tests. Nuclear power facilities have experienced various electrical cable failures related to water exposure. The current industry response involves actions to de-water cable vaults, manholes, and other cable locations. These efforts require considerable expenditure of resources, which makes it desirable for the industry to have information on cable condition and history regarding their submergence and water exposure (Mantey 2012). Two tests that are gaining favor within the nuclear industry are time-domain reflectometry (TDR) and FDR. These are low-voltage nondestructive tests that can be applied at a cable end. Testing from the cable end is important because local inspection along the cable length is very difficult due to cables being routed within trays, conduits, underground, and through walls. Both TDR and FDR techniques have been shown to locate cable insulation damage due to thermal, radiation, and mechanical damage. FDR measurements are also more sensitive than TDR to temperature changes, low-bend radius bends, and cable contact with various materials, including conductive materials like steel and water. This work evaluates the feasibility to extend FDR testing to characterizing whether an electrical cable is submerged or not and where it may be submerged using PNNL’s ARENA cable/motor test bed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Frequency Domain Reflectometry (FDR) Simulation Techniques for Digital Twin Representation of an Electrical Cable

Simulation of cable system response to frequency domain reflectometry (FDR) tests can be instrumental to understanding these tests and the nature and influence of various cable anomalies on test signatures. Reflectometry simulations are based upon a finite element representation of cable conductors and insulation to produce an S-parameter at each evaluated frequency. The aggregate collection of cable model S-parameters can simulate the influence on a test signal injected into a physical cable. Such an approach was undertaken in this work to produce a digital twin simulation of a low-voltage electrical cable. The electrical cable digital twin examined the influence of test simulation parameters and the relative influence of cable anomalies, including thermal aging, water or moisture exposure, water or moisture ingress, and other anomalies. The digital twin in this work included modeling of the conductors, insulation, jacket, and surrounding environment (air, water, etc.). The digital twin could be expanded to include cable bends, junctions and splices, branch or T systems, and termination impedances of motors or instruments. Observations and conclusions of this work include: 1. Fully 3D digital twin simulation of an electrical cable using an FDR approach is possible. However, there are tradeoffs between simulation fidelity and solution time, which must be balanced to ensure the simulation solves in an adequate amount of time (e.g., less than 20 minutes). Simulation parameters to balance include frequency bandwidth, number of frequencies, mesh density, connection impedance, and permittivity tolerance. 2. The digital twin simulation can explain FDR sensitivity to various cable anomalies, including entry and exit from an oven or water bath. 3. The digital twin simulation FDR response attenuates with distance along the cable and is further affected by the frequency bandwidth, which is similar to that observed with physical measurements. 4. The resolution of the digital twin FDR peaks increased with increasing bandwidth and with increasing number of frequencies, again similar to physical measurements. 5. The presence of multiple anomalies in the digital twin does not substantially attenuate the FDR response to anomalies located beyond the first encountered anomaly and impedance mismatch. 6. Spectral variation of the permittivity did not have a significant effect on the FDR response compared to a fixed nominal value. 7. Extension of the digital twin to 1000 ft still allowed for detection of distal anomalies near the far end of the electrical cable from the instrument connection point. 8. The ARENA test bed facilitates efficient NDE evaluations of well understood cable anomalies with various NDE methods without risking actual plant damage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗