Search NASA⌕ Search

SEARCH · Search NASA

Results for “refueling station”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Enhanced methods for operating refueling station tube-trailers to reduce refueling cost

A method and apparatus are provided for operating a refueling station including source tube-trailers and at least one compressor to reduce refueling cost. The refueling station includes a gaseous fuel supply source including a plurality of tanks on a tube trailer coupled to a first control unit, and high pressure buffer storage having predefined capacity coupled to a second control unit and the first tanks by a pressure control valve and the first control unit, and at least one compressor. The refueling station is operated at different modes depending on a state of the refueling station at the beginning of each operational mode. The refueling system is assessed at the end of each operational mode to identify the state of the system and select a next mode of operation. The operational modes include consolidating hydrogen, or any gaseous fuel, within the tubes mounted on the trailer.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Providing Levelized Cost and Waiting Time Inputs for HDV Hydrogen Refueling Station Planning: A Case Study of U.S. I-75 Corridor

Widespread use of diesel fuels in freight transportation leads to greenhouse gas (GHG) emissions that play an important role in air pollution. The air pollution, as well as the energy crisis, drives the transition from diesel fuel to cleaner and more energy-efficient fuels such as hydrogen fuels. With such a transition, the strategic planning and optimization of supporting refueling infrastructure along the national highway for heavy-duty vehicles (HDVs) become a necessity. Cost and service level are two essential factors to be considered in hydrogen refueling station location and capacity optimization. The service level in this study is assessed by the delay (waiting time) at fueling stations as well as the fueling demand fulfilled. To this end, this study presents a methodology to provide waiting time (delay) and levelized hydrogen fuel cost inputs under different station configurations (number of dispensers and fill rates) for hydrogen refueling station planning. Determining the station configurations based on the trade-off between the two inputs is further discussed. Particularly, this study points out that the levelized cost and waiting time are affected by hourly demand patterns and estimates the two inputs under different peak hour fueling demand scenarios. The results suggest that, with the same daily demand, the cost, as well as the waiting time, increases obviously with the peak hour demand. In the case study, the cost grows at least 30% when the peak hour visit frequency of the daily total visits increases from 5% (evenly distributed pattern) to 10% (the most common pattern for existing diesel fueling stations along I-75). Accounting for this peak hour effect in hydrogen refueling station planning is recommended. Overall, the waiting time model and cost analysis provide key inputs for optimizing hydrogen refueling station location and configurations based on anticipated refueling demand patterns. The paper is the second in a series that aims to build a comprehensive modeling plan and optimize hydrogen refueling infrastructure along the Interstate 75 (I-75) corridor for HDVs.

Liu, Yuandong↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

Risk associated with the use of barriers in hydrogen refueling stations.

Separation distances are used in hydrogen refueling stations to protect people, structures, and equipment from the consequences of accidental hydrogen releases. Specifically, hydrogen jet flames resulting from ignition of unintended releases can be extensive in length and pose significant radiation and impingement hazards. Depending on the leak diameter and source pressure, the resulting separation distances can be unacceptably large. One possible mitigation strategy to reduce exposure to hydrogen flames is to incorporate barriers around hydrogen storage, process piping, and delivery equipment. The effectiveness of barrier walls to reduce hazards at hydrogen facilities has been previously evaluated using experimental and modeling information developed at Sandia National Laboratories. The effect of barriers on the risk from different types of hazards including direct flame contact, radiation heat fluxes, and overpressures associated with delayed hydrogen ignition has subsequently been evaluated and used to identify potential reductions in separation distances in hydrogen facilities. Both the frequency and consequences used in this risk assessment and the risk results are described. The results of the barrier risk analysis can also be used to help establish risk-informed barrier design requirements for use in hydrogen codes and standards.

08 HYDROGEN↗

Manufacturing Competitiveness and Supply Chain Analyses for Hydrogen Refueling Stations

This slide deck was presented in the monthly FCTO webinar series (May 2017). The goal of this presentation was to share our latest results and remarks on the manufacturing competitiveness analysis of the hydrogen refueling stations (HRS). Manufacturing cost models were developed for major systems in the HRS such as compressors, storage tanks, chillers, heat exchangers, and dispensers. In addition to the cost models, we also discussed important remarks from our analysis for the international trade flows and global supply chain for the hydrogen refueling stations. The last part of the presentation also highlights effect of economies of scale and high production volumes on lowering the cost of the hydrogen at the pump.

30 DIRECT ENERGY CONVERSION↗

Techno-economic and thermodynamic analysis of pre-cooling systems at gaseous hydrogen refueling stations

In this study, we conducted a techno-economic and thermodynamic analysis of precooling units (PCUs) at hydrogen refueling stations and developed a cost-minimizing design algorithm for the PCU observing the SAE J2601 refueling protocol for T40 stations. In so doing, we identified major factors that affect PCU cost and energy use. The hydrogen precooling energy intensity depends strongly on the station utilization rate, but approaches 0.3 kWh e /kg-H 2 at full utilization. In early fuel cell electric vehicle markets where utilization of the refueling capacity is low, the overhead cooling load (to keep the heat exchanger cold at -40°C) results in significantly high PCU energy intensity because only a small amount of hydrogen is being dispensed. We developed a parameterized precooling energy intensity prediction formula as a function of the ambient temperature and station utilization rate. We also found that the Joule-Thomson effect of the flow control device introduces a significant increase in temperature upstream of the PCU’s heat exchanger (HX), which impacts the PCU design capacity. An optimal PCU (per dispenser, at 35°C HX inlet temperature) consists of a 13-kW refrigerator and a HX with 1400 kg of thermal mass (aluminum), which currently costs $70,000 (uninstalled). Finally, the total (installed) capital and operation cost of PCU at a fully utilized hydrogen refueling station adds $0.50/kg-H 2 .

08 HYDROGEN↗

Refueling Station, Diesel, Operation

This unit process includes the emissions from operation of a refueling station for diesel. Emissions from fuel evaporation during storage and tank loading and unloading operations are included. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=589BCDAD-F002-4373-A905-50C80B1CEF2E

02 PETROLEUM↗

Insights from Hydrogen Refueling Station Manufacturing Competitiveness Analysis

In work for the Clean Energy Manufacturing Analysis Center (CEMAC), NREL is currently collaborating with Great Lakes Wind Network in conducting a comprehensive hydrogen refueling stations manufacturing competitiveness and supply chain analyses. In this project, CEMAC will be looking at several metrics that will facilitate understanding of the interactions between and within the HRS supply chain, such metrics include innovation potential, intellectual properties, learning curves, related industries and clustering, existing supply chains, ease of doing business, and regulations and safety. This presentation to Fuel Cell Seminar and Energy Exposition 2015 highlights initial findings from CEMAC's analysis.

30 DIRECT ENERGY CONVERSION↗

Two-tier tube-trailer pressure consolidation operation method for hydrogen refueling station cost reduction

An operation strategy known as two-tier “pressure consolidation” of delivered tube-trailers (or equivalent supply storage) has been developed to maximize the throughput at gaseous hydrogen refueling stations (HRSs) for fuel cell electric vehicles (FCEVs). The high capital costs of HRSs and the consequent high investment risk are deterring growth of the infrastructure needed to promote the deployment of FCEVs. Stations supplied by gaseous hydrogen will be necessary for FCEV deployment in both the near and long term. Here, the two-tier pressure consolidation method enhances gaseous HRSs in the following ways: (1) reduces the capital cost compared with conventional stations, as well as those operating according to the original pressure consolidation approach described by Elgowainy et al. (2014) [1], (2) minimizes pressure cycling of HRS supply storage relative to the original pressure consolidation approach; and (3) increases use of the station’s supply storage (or delivered tube-trailers) while maintaining higher state-of-charge vehicle fills.

08 HYDROGEN↗

Venting losses from the LH 2 trailer at the refueling station

LH 2 trailers typically vent significant amounts of vapor following delivery at a refueling station. See for example the picture on Fig. 1 of the vapor cloud due to the depressurization of trailer #7016 at LLNL. That practice is possibly too conservative with regards to the Code of Federal Regulations.

25 ENERGY STORAGE↗

Refueling Station, Ethanol, Operation

This unit process includes the emissions from the operation of a refueling station for an ethanol and gasoline blended fuel. Electricity demand and emissions from fuel evaporation during station filling and vehicle filling are also included. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=1983FDBF-2320-46C2-A043-BF8A14B120B1

09 BIOMASS FUELS↗

Fire Protection Engineering Design Brief Template: Hydrogen Refueling Station

Building a hydrogen infrastructure system is critical to supporting the development of alternate- fuel vehicles. This report provides a methodology for implementing a performance-based design of an outdoor hydrogen refueling station that does not meet specific prescriptive requirements in NFPA 2, The Hydrogen Technologies Code . Performance-based designs are a code-compliant alternative to meeting prescriptive requirements. Compliance is demonstrated by comparing a prescriptive-based fueling station design with a performance-based design approach using Quantitative Risk Assessment (QRA) methods and hydrogen risk assessment tools. This template utilizes the Sandia-developed QRA tool, Hydrogen Risk Analysis Models (HyRAM), which combines reduced-order deterministic models that characterize hydrogen release and flame behavior with probabilistic risk models to quantify risk values. Each project is unique and this template is not intended to account for site-specific characteristics. Instead, example content and a methodology are provided for a representative hydrogen refueling site which can be built upon for new hydrogen applications.

08 HYDROGEN↗

Sustainable hydrogen manufacturing via renewable-integrated intensified process for refueling stations

The widescale consumer adoption of hydrogen fuel cell electric vehicles (HFCEVs) is currently hindered by the high cost of small-scale hydrogen generation and the lack of extensive hydrogen refueling infrastructure. Natural gas-based hydrogen is cheaper when produced in large volumes but is also associated with high CO 2 emissions. To counter these challenges, we propose a hybrid approach where both natural gas and renewables are integrated in a synergistic manner using a dynamic process intensification technology that can be deployed on-site for meeting local demands of refueling stations. The technology is based on sorption enhanced steam methane reforming (SE-SMR) that utilizes a combination of reaction with in-situ CO 2 adsorption for enhancing process modularity, productivity and efficiency thereby outperforming conventional SMR at small scale. We develop a mixed integer linear programming (MILP)-based optimization framework for simultaneous design and scheduling of the SE-SMR process. The simultaneous optimization provides a synergistic combination whereby the renewables allow sustainable hydrogen manufacturing and the dynamic SE-SMR allows optimal use of the intermittency of the renewables. The U.S. nationwide analysis indicates that for futuristic renewable prices and a hydrogen production capacity of 2 ton/day, hydrogen can be produced at 50% less cost compared to the current cost of small-scale hydrogen generation. Finally, the city-wise analysis with varying hydrogen demand shows that even with just 5% HFCEV market penetration level, hydrogen production cost less than $3/kg can be obtained at small scales across the United States with even cheaper hydrogen for large cities.

08 HYDROGEN↗

H2USA: Siting Refueling Stations in the Northeast

To achieve cost-effective deployment of both fuel cell electric vehicles (FCEVs) and hydrogen stations, the number of vehicles and public stations must grow together in areas of highest demand. This fact sheet introduces two advanced modeling tools and presents preliminary analysis of the hydrogen refueling station locations needed to support early consumer demand for FCEVs in the Northeast United States. United States.

33 ADVANCED PROPULSION SYSTEMS↗

Refueling-station costs for metal hydride storage tanks on board hydrogen fuel cell vehicles

Refueling costs account for much of the fuel cost for light-duty hydrogen fuel-cell electric vehicles. We estimate cost savings for hydrogen dispensing if metal hydride (MH) storage tanks are used on board instead of 700-bar tanks. Here, we consider a low-temperature, low-enthalpy scenario and a high-temperature, high-enthalpy scenario to bracket the design space. The refueling costs are insensitive to most uncertainties. Uncertainties associated with the cooling duty, coolant pump pressure, heat exchanger (HX) fan, and HX operating time have little effect on cost. The largest sensitivities are to tank pressure and station labor. The cost of a full-service attendant, if the refueling interconnect were to prevent self-service, is the single largest cost uncertainty. MH scenarios achieve 0.71–0.75/kg-H 2 savings by reducing compressor costs without incurring the cryogenics costs associated with cold-storage alternatives. Practical refueling station considerations are likely to affect the choice of the MH and tank design.

08 HYDROGEN↗