Search NASA⌕ Search

SEARCH · Search NASA

Results for “regenerative water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A hybrid regenerative water recovery system for lunar/Mars life support applications

Long-duration manned space missions will require integrated biological and physicochemical processes for recovery of resources from wastes. This paper discusses a hybrid regenerative biological and physicochemical water recovery system designed and built at NASA's Crew and Thermal Systems Division at Johnson Space Center. The system is sized for a four-person crew and consists of a two-stage, aerobic, trickling filter bioreactor; a reverse osmosis system; and a photocatalytic oxidation system. The system was designed to accommodate high organic and inorganic loadings and a low hydraulic loading. The bioreactor was designed to oxidize organics to carbon dioxide and water; the reverse osmosis system reduces inorganic content to potable quality; and the photocatalytic oxidation unit removes residual organic impurities (part per million range) and provides in situ disinfection. The design and performance of the hybrid system for producing potable/hygiene water is described. Aspects of the system such as closure, automation and integration are discussed and preliminary results presented.

Verostko, Charles E.↗

Space Station Freedom regenerative water recovery system configuration selection

The Space Station Freedom (SSF) must recover water from various waste water sources to reduce 90 day water resupply demands for a four/eight person crew. The water recovery system options considered are summarized together with system configuration merits and demerits, resource advantages and disadvantages, and water quality considerations used to select the SSF water recovery system.

Reysa, R.↗

Regenerative (Regen) ECLSS Operations Water Balance

In November 2008, the Water Regenerative System racks were launched aboard Space Shuttle flight, STS-126 (ULF2) and installed and activated on the International Space Station (ISS). These racks, consisting of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA), completed the installation of the Regenerative (Regen) ECLSS systems which includes the Oxygen Generator Assembly (OGA) that was launched 2 years prior. With the onset of active water management on the US segment of the ISS, a new operational concept was required, that of "water balance." Even more recently, in 2010 the Sabatier system came online which converts H2 and CO2 into water and methane. The Regen ECLSS systems accept condensation from the atmosphere, urine from crew, and processes that fluid via various means into potable water which is used for crew drinking, building up skip-cycle water inventory, and water for electrolysis to produce oxygen. Specification rates of crew urine output, condensate output, O2 requirements, toilet flush water and drinking needs are well documented and used as a general plan when Regen ECLSS came online. Spec rates are useful in long term planning, however, daily or weekly rates are dependent on a number of variables. The constantly changing rates created a new challenge for the ECLSS flight controllers, who are responsible for operating the ECLSS systems onboard ISS. This paper will review the various inputs to rate changes and inputs to planning events, including but not limited to; crew personnel makeup, Regen ECLSS system operability, vehicle traffic, water containment availability, and Carbon Dioxide Removal Assembly (CDRA) capability. Along with the inputs that change the various rates, the paper will review the different systems, their constraints and finally the operational means by which flight controllers manage this new challenge of "water balance."

Tobias, Barry↗

Status of the Regenerative ECLS Water Recovery System

The regenerative Water Recovery System (WRS) has completed its first full year of operation on the International Space Station (ISS). The major assemblies included in this system are the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA). This paper summarizes the on-orbit status as of May 2010, and describes the technical challenges encountered and lessons learned over the past year.

Carter, Donald Layne↗

Status of the Regenerative ECLSS Water Recovery System

NASA is developing a regenerative water recovery system (WRS) for deployment on the International Space Station (ISS), The major assemblies included in this system are the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA). The WPA has been developed by Hamilton Sundstrand Space Systems International (HSSSI), Inc., while the UPA has been developed by the Marshall Space Flight Center (MSFC). Test and verification activities have been completed for the system and planning for launch and on-orbit activation is underway. This paper summarizes the status as of April 2007 and describes some of the technical challenges encountered and lessons learned over the past year.

Bagdigian, Robert M.↗

Status of the Regenerative ECLSS Water Recovery System

NASA has completed the delivery of the regenerative Water Recovery System (WRS) for the International Space Station (ISS). The major assemblies included in this system are the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA). This paper summarizes the final effort to deliver the hardware to the Kennedy Space Center for launch on STS-126, the on-orbit status as of April 2009, and describes some of the technical challenges encountered and lessons learned over the past year.

Carter, Donald Layne↗

Status of the International Space Station Regenerative ECLSS Water Recovery and Oxygen Generation Systems

NASA is developing three racks containing regenerative water recovery and oxygen generation systems (WRS and OGS) for deployment on the International Space Station (ISS). The major assemblies included in these racks are the Water Processor Assembly (WPA), Urine Processor Assembly (UPA), Oxygen Generation Assembly (OGA), and the Power Supply Module (PSM) supporting the OGA. The WPA and OGA are provided by Hamilton Sundstrand Space Systems International (HSSSI), Inc., while the UPA and PSM are developed in- house by the Marshall Space Flight Center (MSFC). The assemblies have completed the manufacturing phase and are in various stages of testing and integration into the flight racks. This paper summarizes the status as of April 2005 and describes some of the technical challenges encountered and lessons learned over the past year.

Bagdigian, Robert M.↗

Status of the Node 3 Regenerative ECLSS Water Recovery and Oxygen Generation Systems

NASA's Marshall Space Flight Center is providing three racks containing regenerative water recovery and oxygen generation systems (WRS and OGS) for flight on the International Space Station's (ISS) Node 3 element. The major assemblies included in these racks are the Water Processor Assembly (WPA), Urine Processor Assembly (UPA), Oxygen Generation Assembly (OGA), and the Power Supply Module (PSM) supporting the OGA. The WPA and OGA are provided by Hamilton Sundstrand Space Systems International (HSSSI), while the UPA and PSM are being designed and manufactured in-house by MSFC. The assemblies are completing the manufacturing phase and are in various stages of ORU and system level testing, to be followed by integration into the flight racks. This paper gives a current status, along with technical challenges encountered and lessons learned.

Carrasquillo, Robyn L.↗

Closing the Loop on Space Trash / Is a Circular Economy Possible?

A crew member will nominally consume 2.5 kg of water per crew-member per day, rejectapproximately 0.032 kg of dry fecal solid waste per crew member per day (dry basis)and generate approximately 2,122 kg of logistical waste per year on a long-durationcrewed mission. This topic seeks to push the conversation towards completing a closedloop system and circular economy for all materials and recoverable resources withregard to waste management, regenerative water use, and recycling. In all aspects,reduction of crew maintenance time, mass, power and volume are at the forefront oftechnology development. In addition, the longevity and hardware robustness is important(lasting >3 years). Overall water recovery of >98% is desired, as well as, condensingheat exchangers that remove water from air with collection rates up to 1.45 kg of waterper hour. There are many technologies on the ground being developed for recycling andtrash management or regenerative water use that have yet to introduce themselves forspace development and infusion. Here we look to open the conversation and cross cutthese platforms to bring out some innovation and exposure into the hidden crevasses ofthe waste that humans create and how to minimize it/repurpose it, for all of humanity.

ISRU↗

Water Recovery from Bioreactor Mixed Liquors Using Forward Osmosis with Polyelectrolyte Draw Solutions

This paper reports on the use of forward osmosis (FO) with polyelectrolyte draw solutions to recover water from bioreactor mixed liquors. The work was motivated by the need for new regenerative water purification technologies to enable long-duration space missions. Osmotic membrane bioreactors may be an option for water and nutrient recovery in space if they can attain high water flux and reverse solute flux selectivity (RSFS), which quantifies the mass of permeated water per mass of draw solute that has diffused from the draw solution into a bioreactor. Water flux was measured in a direct flow system using wastewater from a municipal wastewater treatment plant and draw solutions prepared with two polyelectrolytes at different concentrations. The direct flow tests displayed a high initial flux (>10 L/m2/h) that decreased rapidly as solids accumulated on the feed side of the membrane. A test with deionized water as the feed revealed a small mass of polyelectrolyte crossover from the draw solution to the feed, yielding an RSFS of 80. Crossflow filtration experiments demonstrated that steady state flux above 2 L/m2·h could be maintained for 70 h following an initial flux decline due to the formation of a foulant cake layer. This study established that FO could be feasible for regenerative water purification from bioreactors. By utilizing a polyelectrolyte draw solute with high RSFS, we expect to overcome the need for draw solute replenishment. This would be a major step towards sustainable operation in long-duration space missions.

Calen R Raulerson↗

Development of the Miniature Total Organic Carbon Analyzer

Monitoring the Total Organic Carbon (TOC) in spacecraft potable water will be of major importance in long-duration human space exploration. In-flight analysis of potable water produced from a regenerative water processor provides immediate feedback on the quality of reclaimed water for crew health as well as water processing system health monitoring. This paper updates the progress in development of the next generation Total Organic Carbon Analyzer (TOCA) designed for the unique requirements of an exploration-class mission. The current objective is to design, build, certify, deliver, and operate a TOCA technology demonstration on the International Space Station (ISS). The next generation analyzer system technology was previously developed and selected among a feasibility study of other options. The new system provides primary advantages of reduced mass and volume through reduced system complexity and reduced need for consumables; therefore, the flight project is named MiniTOCA. The project has recently completed design of the tech demo instrument and assembled and tested a flight-like engineering development unit. The engineering unit has undergone performance testing and environmental testing which provides confidence for the project to move forward with flight unit production and certification activities. Test results are summarized in this paper. The flight unit is targeted for delivery to ISS in late 2025.

TOC↗

Development of the Miniature Total Organic Carbon Analyzer

Monitoring the Total Organic Carbon (TOC) in spacecraft potable water will be of major importance in long-duration human space exploration. In-flight analysis of potable water produced from a regenerative water processor provides immediate feedback on the quality of reclaimed water for crew health as well as water processing system health monitoring. This paper updates the progress in development of the next generation Total Organic Carbon Analyzer (TOCA) designed for the unique requirements of an exploration-class mission. The current objective is to design, build, certify, deliver, and operate a TOCA technology demonstration on the International Space Station (ISS). The next generation analyzer system technology was previously developed and selected among a feasibility study of other options. The new system provides primary advantages of reduced mass and volume through reduced system complexity and reduced need for consumables; therefore, the flight project is named MiniTOCA. The project has recently completed design of the tech demo instrument and assembled and tested a flight-like engineering development unit. The engineering unit has undergone performance testing and environmental testing which provides confidence for the project to move forward with flight unit production and certification activities. Test results are summarized in this paper. The flight unit is targeted for delivery to ISS in late 2025.

TOC↗

International Space Station Water Balance Operations

In November 2008, the Water Regenerative System racks were launched aboard Space Shuttle flight, STS-126 (ULF2) and installed and activated on the International Space Station (ISS). These racks, consisting of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA), completed the installation of the Regenerative (Regen) Environmental Control and Life Support Systems (ECLSS), which includes the Oxygen Generation Assembly (OGA) that was launched 2 years prior. With the onset of active water management on the US segment of the ISS, a new operational concept was required, that of water balance . In November of 2010, the Sabatier system, which converts H2 and CO2 into water and methane, was brought on line. The Regen ECLSS systems accept condensation from the atmosphere, urine from crew, and processes that fluid via various means into potable water, which is used for crew drinking, building up skip-cycle water inventory, and water for electrolysis to produce oxygen. Specification (spec) rates of crew urine output, condensate output, O2 requirements, toilet flush water, and drinking needs are well documented and used as the best guess planning rates when Regen ECLSS came online. Spec rates are useful in long term planning, however, daily or weekly rates are dependent upon a number of variables. The constantly changing rates created a new challenge for the ECLSS flight controllers, who are responsible for operating the ECLSS systems onboard ISS from Mission Control in Houston. This paper reviews the various inputs to water planning, rate changes, and dynamic events, including but not limited to: crew personnel makeup, Regen ECLSS system operability, vehicle traffic, water storage availability, and Carbon Dioxide Removal Assembly (CDRA), Sabatier, and OGA capability. Along with the inputs that change the various rates, the paper will review the different systems, their constraints, and finally the operational challenges and means by which flight controllers manage this new concept of "water balance."

Tobias, Barry↗

Development of an advanced combined iodine dispenser/detector

Injection of iodine into water is widely used to control microbial growth. An entirely automated device for I2 injection has been developed for spacecraft application. Transfer of I2 into the water from a concentrated form is controlled electrochemically via feedback from an integrated photometric I2 level detector. All components are contained within a package weighing only 1.23 kg (2.7 lb) dry, which occupies only 1213 cu cm (74 cu in) of space, and which has the capacity to iodinate 10,900 kg (24,000 lb) of water of 5 ppm. These features exceed design specifications. The device performed satisfactorily during extended testing at variable water flow rates and temperatures. Designed to meet specifications of the Shuttle Orbiter, the device will find application in the regenerative water systems of advanced spacecraft.

Lantz, J. B.↗

Post-treatment of reclaimed waste water based on an electrochemical advanced oxidation process

The purification of reclaimed water is essential to water reclamation technology life-support systems in lunar/Mars habitats. An electrochemical UV reactor is being developed which generates oxidants, operates at low temperatures, and requires no chemical expendables. The reactor is the basis for an advanced oxidation process in which electrochemically generated ozone and hydrogen peroxide are used in combination with ultraviolet light irradiation to produce hydroxyl radicals. Results from this process are presented which demonstrate concept feasibility for removal of organic impurities and disinfection of water for potable and hygiene reuse. Power, size requirements, Faradaic efficiency, and process reaction kinetics are discussed. At the completion of this development effort the reactor system will be installed in JSC's regenerative water recovery test facility for evaluation to compare this technique with other candidate processes.

Verostko, Charles E.↗

To Biocide or not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

To Biocide or not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

To Biocide or Not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗