Printed hygroscopic electrodes for low-cost capacitive relative humidity sensors

A capacitive relative humidity sensor includes a first electrode and a second electrode, where at least the one of the electrodes is a water-permeable electrode. The electrodes act in conjunction with a water-sensitive hygroscopic dielectric material. The design enables low-cost and simple fabrication of fast-responding and stable relative humidity sensors using digital fabrication techniques.

Pierre, Adrien↗

Hydration of α-UO 3 following storage under controlled conditions of temperature and relative humidity

Changes in chemical speciation of uranium oxides following storage under varied conditions of temperature and relative humidity are valuable for characterizing material provenance. In this study, subsamples of high purity α-UO 3 were stored under four sets of controlled conditions of temperature and relative humidity over several years, and then measured periodically for chemical speciation. Powder X-ray diffraction (XRD) analysis and extended X-ray absorption fine structure spectroscopy confirm hydration of α-UO 3 to a schoepite-like end product following storage under each of the varied storage conditions, but the species formed during exposure to the lower relative humidity and lower temperature condition follows different trends from those formed under the other three storage conditions (high relative humidity with high or low temperatures, and low relative humidity with a high temperature). Thermogravimetry coupled with XRD analysis was carried out to distinguish desorption pathways of water from the hydrated end products. Density functional theory calculations discern changes in the structure of α-UO 3 following incorporation of 1, 2 or 3 H 2 O molecules or 1, 2 or 3 OH groups into the orthorhombic lattice, revealing differences in lattice constants, U–O bond lengths, and U–U distances. The collective results from this analysis are in contrast to analogous studies that report that U 3 O 8 is oxidized and hydrated in air during storage under high relative humidity conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lidar Measurements of Relative Humidity and Ice Supersaturation in the Upper Troposphere

We compute upper tropospheric relative humidity profiles using water vapor profiles measured by an airborne DIAL and a ground-based Raman lidar. LASE water vapor and MTP temperature profiles acquired from the NASA DC-8 aircraft during the recent Pacific Exploratory Mission Tropics B (PEM Tropics B) field mission in the tropical Pacific and the SAGE-III Ozone Loss and Validation Experiment (SOLVE) in the Arctic as well as water vapor profiles derived from the ground-based DOE ARM Southern Great Plains (SGP) CART Raman lidar are used. Comparisons of the lidar water vapor measurements with available in situ measurements show reasonable agreement for water vapor mixing ratios above 0.05 g/kg. Relative humidity frequency distributions computed using LASE data indicate that ice supersaturation occurred about 5-11% of the time when temperatures were below -35 C. While a higher frequency of ice supersaturation was observed during SOLVE, higher peak values of relative humidity were observed during PEM Tropics B. The relative humidity fields associated with cirrus clouds are also examined.

Ferrare, Richard A.↗

Experiments with the Mesoscale Atmospheric Simulation System (MASS) using the synthetic relative humidity

This study is intended to examine the impact of the synthetic relative humidity on the model simulation of mesoscale convective storm environment. The synthetic relative humidity is derived from the National Weather Services surface observations, and non-conventional sources including aircraft, radar, and satellite observations. The latter sources provide the mesoscale data of very high spatial and temporal resolution. The synthetic humidity data is used to complement the National Weather Services rawinsonde observations. It is believed that a realistic representation of initial moisture field in a mesoscale model is critical for the model simulation of thunderstorm development, and the formation of non-convective clouds as well as their effects on the surface energy budget. The impact will be investigated based on a real-data case study using the mesoscale atmospheric simulation system developed by Mesoscale Environmental Simulations Operations, Inc. The mesoscale atmospheric simulation system consists of objective analysis and initialization codes, and the coarse-mesh and fine-mesh dynamic prediction models. Both models are a three dimensional, primitive equation model containing the essential moist physics for simulating and forecasting mesoscale convective processes in the atmosphere. The modeling system is currently implemented at the Applied Meteorology Unit, Kennedy Space Center. Two procedures involving the synthetic relative humidity to define the model initial moisture fields are considered. It is proposed to perform several short-range (approximately 6 hours) comparative coarse-mesh simulation experiments with and without the synthetic data. They are aimed at revealing the model sensitivities should allow us both to refine the specification of the observational requirements, and to develop more accurate and efficient objective analysis schemes. The goal is to advance the MASS (Mesoscal Atmospheric Simulation System) modeling expertise so that the model output can provide reliable guidance for thunderstorm forecasting.

Chang, Chia-Bo↗

Global distributions of upper tropospheric relative humidity derived from SAGE II observations

The global distributions of upper tropospheric relative humidity derived from the archived SAGE II water vapor data set are presented. For both summer and winter months, vertical profiles of zonal mean relative humidity are derived for each of the six 20-deg latitude bands covering 60 deg N - 60 deg S. Some examples of global maps of upper tropospheric relative humidity are shown to illustrate the relationship between moist areas and convective activity.

Chiou, E. W.↗

Water adsorption on vanadium oxide thin films in ambient relative humidity

Here in this work, ambient pressure x-ray photoelectron spectroscopy (APXPS) is used to study the initial stages of water adsorption on vanadium oxide surfaces. V 2p, O 1s, C 1s, and valence band XPS spectra were collected as a function of relative humidity in a series of isotherm and isobar experiments. Experiments were carried out on two VO 2 thin films on TiO 2 (100) substrates, prepared with different surface cleaning procedures. Hydroxyl and molecular water surface species were identified, with up to 0.5 ML hydroxide present at the minimum relative humidity, and a consistent molecular water adsorption onset occurring around 0.01% relative humidity. The work function was found to increase with increasing relative humidity, suggesting that surface water and hydroxyl species are oriented with the hydrogen atoms directed away from the surface. Changes in the valence band were also observed as a function of relative humidity. The results were similar to those observed in APXPS experiments on other transition metal oxide surfaces, suggesting that H 2 O-OH and H 2 O-H 2 O surface complex formation plays an important role in the oxide wetting process and water dissociation. Compared to polycrystalline vanadium metal, these vanadium oxide films generate less hydroxide and appear to be more favorable for molecular water adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal Microbalance Monitors Relative Humidity

Sensor monitors water evaporation in industrial drying processes. Measured adsorption isotherm for instrument essentially linear over entire range of relative humidity. Testing at each temperature setting less than half hour for full relative-humidity range, with estimated frequency response time less than 10 seconds. Used to measure relative humidity of ambient atmosphere near drying paper, food textile fabrics and pulp to optimize water-drying portion of processing cycle.

Yang, L. C.↗

Relative Humidity Measurement Assurance Program Results

During the summer of 1992, the National Conference of Standards Laboratories sponsored a relative humidity measurement assurance program (RHMAP) whose purpose was to enable each participating center to assess the quality of relative humidity calibrations being performed by their respective standards laboratories. This paper presents the data which was submitted by the participants during the first round of the program and shows the multi-laboratory comparisons of the 20%, 50%, and 80% relative humidity meaurements performed.

Humidity↗

Global seasonal variations of the near-surface relative humidity levels on present-day Mars

We investigate the global seasonal variations of near-surface relative humidity and relevant attributes, like temperature and water vapor volume mixing ratio on Mars using calculations from modelled and measurement data. We focus on 2 AM local time snapshots to eliminate daily effects related to differences in insolation, and to be able to compare calculations based on modelling data from the Laboratoire de Météorologie Dynamique Mars General Circulation Model with the observations of Mars Global Surveyor Thermal Emission Spectrometer. We study the seasonal effects by examining four specific dates in the Martian year, the northern spring equinox, summer solstice, autumn equinox, and winter solstice. We identify three specific zones, where the near-surface relative humidity levels are systematically higher than in their vicinity regardless of season. We find that these areas coincide with low thermal inertia features, which control surface temperatures on the planet, and are most likely covered with unconsolidated fine dust with grain sizes smaller than ∼ 40 μm. By comparing the data of relative humidity, temperature and water vapor volume mixing ratio at three different heights (near-surface, ∼ 4m and ∼ 23m above the surface), we demonstrate that the thermal inertia could play an important role in determining near-surface humidity levels. We also notice that during the night the water vapor levels drop at ∼ 4m above the surface. This, together with the temperature and thermal inertia values, shows that water vapor likely condenses in the near-surface atmosphere and on the ground during the night at the three aforementioned regions. This condensation may be in the form of brines, wettening of the fine grains by adsorption or deliquescence. This study specifies areas of interest on the surface of present day Mars for the proposed condensation, which may be examined by in-situ measurements in the future.

Bernadett Pál↗

The aging correlation (RH + t): Relative humidity (%) + temperature (deg C)

An aging correlation between corrosion lifetime, and relative humidity RH (%) and temperature t (C) has been reported in the literature. This aging correlation is a semi-log plot of corrosion lifetime on the log scale versus the interesting summation term RH(%) + t(C) on the linear scale. This empirical correlation was derived from observation of experimental data trends and has been referred to as an experimental law. Using electrical resistivity data of polyvinyl butyral (PVB) measured as a function of relative humidity and temperature, it was found that the electrical resistivity could be expressed as a function of the term RH(%) t(C). Thus, if corrosion is related to leakage current through an organic insulator, which, in turn, is a function of RH and t, then some partial theoretical validity for the correlation is indicated. This article describes the derivation of the term RH(%) t(C) from PVB electrical resistivity data.

Cuddihy, E. F.↗

Relative humidity threshold for oxygen generation by high-purity plutonium dioxides in 3013 containers

High-purity plutonium dioxide with adsorbed water in a sealed container can generate oxygen, but oxygen will not be generated in low water loading conditions. A threshold for oxygen generation has been observed in the hydrogen generation rate normalized by the specific power for high-purity plutonium dioxide. Normalized hydrogen generation rates above this threshold generate oxygen and below the threshold consume oxygen. The threshold rate is determined by the amount of water adsorbed onto the surface of the oxide. The relative humidity of the atmosphere that the oxide is in equilibrium with determines the amount of physisorbed water adsorbed on the surface. We calculate the relative humidity corresponding to the threshold rate as a function of mass and specific surface area of material stored in 3013 containers. Exceeding the calculated relative humidity may result in flammable gas mixtures of hydrogen and oxygen at some time during storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solid organic-coated ammonium sulfate particles at high relative humidity in the summertime Arctic atmosphere

The ability of atmospheric aerosols to impact climate through water uptake and cloud formation is fundamentally determined by the size, composition, and phase (liquid, semisolid, or solid) of individual particles. Particle phase is dependent on atmospheric conditions (relative humidity and temperature) and chemical composition and, importantly, solid particles can inhibit the uptake of water and other trace gases, even under humid conditions. Particles composed primarily of ammonium sulfate are presumed to be liquid at the relative humidities (67 to 98%) and temperatures (–2 to 4 °C) of the summertime Arctic. Under these atmospheric conditions, we report the observation of solid organic-coated ammonium sulfate particles representing 30% of particles, by number, in a key size range (<0.2 µm) for cloud activation within marine air masses from the Arctic Ocean at Utqiagvik, AK. The composition and size of the observed particles are consistent with recent Arctic modeling and observational results showing new particle formation and growth from dimethylsulfide oxidation to form sulfuric acid, reaction with ammonia, and condensation of marine biogenic sulfate and highly oxygenated organic molecules. Aqueous sulfate particles typically undergo efflorescence and solidify at relative humidities of less than 34%. Therefore, the observed solid phase is hypothesized to occur from contact efflorescence during collision of a newly formed Aitken mode sulfate particle with an organic-coated ammonium sulfate particle. With declining sea ice in the warming Arctic, this particle source is expected to increase with increasing open water and marine biogenic emissions.

54 ENVIRONMENTAL SCIENCES↗

Implications of Enhanced Relative Humidity in Cold Tropical Cirrus

In situ measurements of water vapor concentration and temperature in tropical cirrus during the CRYSTAL-FACE and Pre-AVE missions indicate that the steady-state relative humidity within cirrus at T less than 200 K is about 20-30% higher than ice saturation. These measurements challenge the conventional belief, that any water vapor in excess of ice saturation should be depleted by crystal growth given sufficient time. Detailed simulations of thin cirrus near the tropopause indicate that this enhanced steady-state relative humidity increases ice number densities, decreases crystal sizes and extends cloud lifetimes. The areal coverage of thin cirrus in the tropics is increased rather than decreased as indicated by simpler conceptual models. Perhaps most significantly, the increased steady-state H2O saturation mixing ratio over ice in thin cirrus near the tropopause results in about a 0.5-1 ppmv increase in the amount of water that can enter the stratosphere across the tropical tropopause cold trap. Hence, the enhanced steady-state relative humidity in cold cirrus implies that lower tropopause temperatures are required to explain the observed stratospheric water vapor mixing ratios than previously assumed.

Jensen, Eric↗

Physical Processes Controlling the Spatial Distributions of Relative Humidity in the Tropical Tropopause Layer over the Pacific

The spatial distribution of relative humidity with respect to ice (RHI) in the boreal wintertime tropical tropopause layer (TTL, is asymptotically Equal to 14-18 km) over the Pacific is examined with the measurements provided by the NASA Airborne Tropical TRopopause EXperiment. We also compare the measured RHI distributions with results from a transport and microphysical model driven by meteorological analysis fields. Notable features in the distribution of RHI versus temperature and longitude include (1) the common occurrence of RHI values near ice saturation over the western Pacific in the lower to middle TTL; (2) low RHI values in the lower TTL over the central and eastern Pacific; (3) common occurrence of RHI values following a constant mixing ratio in the middle to upper TTL (temperatures between 190 and 200 K); (4) RHI values typically near ice saturation in the coldest airmasses sampled; and (5) RHI values typically near 100% across the TTL temperature range in air parcels with ozone mixing ratios less than 50 ppbv. We suggest that the typically saturated air in the lower TTL over the western Pacific is likely driven by a combination of the frequent occurrence of deep convection and the predominance of rising motion in this region. The nearly constant water vapor mixing ratios in the middle to upper TTL likely result from the combination of slow ascent (resulting in long residence times) and wave-driven temperature variability. The numerical simulations generally reproduce the observed RHI distribution features, and sensitivity tests further emphasize the strong influence of convective input and vertical motions on TTL relative humidity.

Jensen, Eric J.↗

The Vertical Structure of Relative Humidity and Ozone in the Tropical Upper Troposphere: Intercomparisons Among In Situ Observations, A-Train Measurements and Large-Scale Models

In situ measurements in the tropics have shown that in regions of active convection, relative humidity with respect to ice in the upper troposphere is typically close to saturation on average, and supersaturations greater than 20% are not uncommon. Balloon soundings with the cryogenic frost point hygrometer (CFH) at Costa Rica during northern summer, for example, show this tendency to be strongest between 11 and 15.5 km (345-360 K potential temperature, or approximately 250-120 hPa). this is the altitude range of deep convective detrainment. Additionally, simultaneous ozonesonde measurements show that stratospheric air (O3 greater than 150 ppbv) can be found as low as approximately 14 km (350 K/150 hPa). In contrast, results from northern winter show a much drier upper troposphere and little penetration of stratospheric air below the tropopause at 17.5 km (approximately 383 K). We show that these results are consistent with in situ measurements from the Measurement of Ozone and water vapor by Airbus In-service airCraft (MOZAIC) program which samples a wider, though still limited, range of tropical locations. To generalize to the tropics as a whole, we compare our insitu results to data from two A-Train satellite instruments, the Atmospheric Infrared Sounder (AIRS) and the Microwave Limb Sounder (MLS) on the Aqua and Aura satellites respectively. Finally, we examine the vertical structure of water vapor, relative humidity and ozone in the NASA Goddard MERRA analysis, an assimilation dataset, and a new version of the GEOS CCM, a free-running chemistry-climate model. We demonstrate that conditional probability distributions of relative humidity and ozone are a sensitive diagnostic for assessing the representation of deep convection and upper troposphere/lower stratosphere mixing processes in large-scale analyses and climate models.

Selkirk, Henry B.↗

Survival of Snow in the Melting Layer: Relative Humidity Influence

This study quantifies how far snow can fall into the melting layer (ML) before all snow has melted by examining a combination of in-situ observations from aircraft measurements in Lagrangian spiral descents from above through the ML and descents and ascents into the ML, as well as an extensive database of NOAA surface observer reports during the past 50 years. The airborne data contain information on the particle phase (solid, mixed, or liquid), population size distributions and shapes, along with temperature, relative humidity, and vertical velocity. A wide range of temperatures and ambient relative humidities are used for both the airborne and ground-based data. It is shown that an ice bulb temperature of 0°C, together with the air temperature and pressure (altitude), are good first order predictors of the highest temperature snowflakes can survive in the melting layer before completely melting. Particle size is also important, as is whether the particles are graupel or hail. If the relative humidity is too low, the particles will sublimate completely as they fall into the melting layer. Snow as warm as +7°C is observed from aircraft measurements and surface observations. Snow pellets survive to even warmer temperatures. Relationships are developed to represent the primary findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A theoretical index for understanding distinct land relative humidity trends in observations, reanalyses, and models

Land surface relative humidity (RH) is a key variable in the coupled land–atmosphere system that profoundly influences terrestrial hydroclimate and ecosystems. Yet historical changes in land RH are not well understood due to limited observations, biased reanalyses, and the lack of a framework for interpreting RH changes under multiple influencing factors. Here, we show that the spatiotemporal variability of land RH and its distinct historical trends among observations, reanalyses, and Earth system models are captured by a simple index based on the ratio of precipitation (P) to a modified potential evapotranspiration formulated independently of RH (PET°). The index provides a physical calibration of biased land RH in reanalyses and a quantitative framework for interpreting land RH changes. Over 1973–2024, land RH has decreased substantially, owing to the intrinsic rise in PET° with temperature and little increase in land precipitation. Reanalyses overestimate the observed RH decrease, consistent with exaggerated surface warming and precipitation decline. The index captures this coherent bias and enables a calibration using observed precipitation and temperature. Models simulate a wide range of land RH trends, but nearly all runs underrepresent the historical drying. The index captures the model spread and discrepancy and attributes them to contributions of precipitation and PET°. Weaker land RH decreases in models arise mainly from weaker subtropical precipitation declines, linked to muted intensification of subtropical highs and biased subtropical climatology. The model–observation discrepancy is unlikely explained by internal variability, implying model underestimation of forced RH decrease and a drier land future than current projections.

Earth system models↗