Search NASA⌕ Search

SEARCH · Search NASA

Results for “reproducibility of results”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Achieving Highly Reproducible Results in Graphite-based Li-ion Full Coin Cells

Electrode materials, cathodes or anodes, are mostly evaluated in half coin cells where lithium (Li) metal is used. However, due to the instability nature of Li metal, the cycling performances of the half cells is more likely reflecting Li anode stability instead of the coupled electrodes, questioning the conclusions. Full coin cells utilizing graphite as the anode effectively assesses materials. But the key factors of preparing full coin cells with reproducible performances have rarely been discussed and overlooked leading to many inconsistent results. This work discusses the scientific gap between cell preparation and observed electrochemical performances to unveil the key parameters for achieving consistent and reliable results in full coin cells, critical for effective evaluation of any new materials tested under relevant conditions. The knowledge from this work is broadly applicable in other full cells systems such as Si-based full cells or Na-ion batteries.

Hu, Jiangtao↗

Reproduced Computational Results Report for “Ginkgo: A Modern Linear Operator Algebra Framework for High Performance Computing”

The article titled “Ginkgo: A Modern Linear Operator Algebra Framework for High Performance Computing” by Anzt et al. presents a modern, linear operator centric, C++ library for sparse linear algebra. Experimental results in the article demonstrate that Ginkgo is a flexible and user-friendly framework capable of achieving high-performance on state-of-the-art GPU architectures. In this report, the Ginkgo library is installed and a subset of the experimental results are reproduced. Specifically, the experiment that shows the achieved memory bandwidth of the Ginkgo Krylov linear solvers on NVIDIA A100 and AMD MI100 GPUs is redone and the results are compared to what presented in the published article. Upon completion of the comparison, the published results are deemed reproducible.

97 MATHEMATICS AND COMPUTING↗

Hydropower Capacity Factor Trends & Analytics for the United States

This data repository contains all code, input data, and data generated for Turner et al. (2024)—“Hydropower capacity factors trending down in the United States”. File descriptions: – hydro-cf-trends-inputs.zip: Full set of input data used in this study, organized for direct entry into “/data” directory of hydro-cf-trends data processing pipeline. – hydro-cf-trends.zip: Full data processing pipeline, coded using the R {targets} framework. This is a snapshot release (v1.0) of the code repository stored at https://code.ornl.gov/turnersw/hydro-cf-trends/. – hydro-cf-trends-results.zip: Provides all dam level results required to reproduce results and graphics in Turner et al. (2024). Dams are identified by the “complxID” (root of the hydropower plant ID in the Existing Hydropower Assets Database, inherited from HILARRI). Results include: • dam_CF_trends.csv: Table of long-term trends in annualized capacity factors for 610 dams and modeled annualized capacity factors for 362 modeled dams (naturalized and assimilated flows). • dam_annualized_CF_gen.csv: Annualized time series of the following variables for each of 610 hydropower dams with nameplate > 5MW – Reported nameplate capacity (MW) – Implied maximum annual generation (MWh) – Reported net generation (MWh) – Computed annual capacity factor – Modeled annual capacity factor (362 modeled plants only)

13 HYDRO ENERGY↗

Epitaxial silicon growth for solar cells

Growth and fabrication procedures for the baseline solar cells are described along with measured cell parameters, and the results. Reproducibility of these results was established and the direction to be taken for higher efficiency is identified.

Daiello, R. V.↗

SCALE Non-LWR Models for NRC Volume 3

This dataset contains input and result files of computational simulations with the SCALE code system. The simulations cover radionuclide inventory and reactivity analyses of various advanced reactors. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE Non-LWR Models for NRC Volume 5

This dataset contains input and result files of computational simulations with the SCALE code system. The simulations cover radionuclide inventory generation, criticality calculations, and dose rate/shielding analyses of various advanced reactors. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE HTR-PROTEUS Benchmark Model

This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An open-source high-content analysis workflow for CFTR function measurements using the forskolin-induced swelling assay

Abstract Motivation The forskolin-induced swelling (FIS) assay has become the preferential assay to predict the efficacy of approved and investigational CFTR-modulating drugs for individuals with cystic fibrosis (CF). Currently, no standardized quantification method of FIS data exists thereby hampering inter-laboratory reproducibility. Results We developed a complete open-source workflow for standardized high-content analysis of CFTR function measurements in intestinal organoids using raw microscopy images as input. The workflow includes tools for (i) file and metadata handling; (ii) image quantification and (iii) statistical analysis. Our workflow reproduced results generated by published proprietary analysis protocols and enables standardized CFTR function measurements in CF organoids. Availability and implementation All workflow components are open-source and freely available: the htmrenamer R package for file handling https://github.com/hmbotelho/htmrenamer; CellProfiler and ImageJ analysis scripts/pipelines https://github.com/hmbotelho/FIS_image_analysis; the Organoid Analyst application for statistical analysis https://github.com/hmbotelho/organoid_analyst; detailed usage instructions and a demonstration dataset https://github.com/hmbotelho/FIS_analysis. Distributed under GPL v3.0. Supplementary information Supplementary data are available at Bioinformatics online.

Hagemeijer, Marne C.↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Chilled-Mirror Humidity Sensor: Improved Radiosonde Measurements

Chilled-mirror humidity sensor technology recently was adapted for use with the VIZ radiosonde. The principle of the chilled-mirror operation is to lower its temperature until dew forms on the mirror, at that point the dew point temperature is noted and the mirror is then heated to evaporate the moisture. The cycle is repeated. Research conducted from NASA's Wallops Flight Facility has provided comparisons between the chilled-mirror sensor and the carbon hygristor of VIZ, and the capacitive sensors of AIR Inc. and Vaisala Co. We believe the chilled-mirror sensor is accurate and would serve as a reference standard for evaluating operational radiosonde relative humidity sensors. Thus, differences seen in the comparisons are beginning to furnish insight into developing better humidity sensors. We discuss these comparison results as well as reproducibility results from a dual chilled-mirror measurement.

Schmidlin, F. J.↗

Emulation of radiation transport in 3D stochastic media using 1D planar Monte Carlo stochastic media radiation transport algorithms

A subset of stochastic media radiation transport problems involves those in which radiation is incident on a thin slab of stochastic material. Particle tracking in 3D for such problems is expensive, and 1D planar models lack accuracy because they only allow the material to change in one dimension. Therefore, we propose dimensional emulation, which through a slight modification allows existing 1D planar geometry stochastic media radiation transport models to reproduce results from the equivalent 3D models by allowing the material to change in all three dimensions, reproducing the fidelity of the 3D model for the low computational cost of the 1D planar model. In this work, we apply dimensional emulation to three Monte Carlo stochastic media radiation transport models: Chord Length Sampling (CLS), the Local Realization Preserving method (LRP), and a variant of Conditional Point Sampling (CoPS). For a common Markovian benchmark set, the 3D emulation variants of these algorithms are numerically verified to reproduce the results of the 3D variants within statistics while running 1.3 to 2 times faster in the implementation within Sandia National Laboratories open-source research code PlaybookMC. The 3D emulation variants are also shown to yield a 72%–92% reduction in error for the thin slab problems in comparison to the 1D benchmark. As a result, the 3D emulation variant of CLS and CoPS-1 are shown to reproduce 3D CLS results that were used to approximate results for a 3D spherical inclusion geometry benchmark set.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Padded Harness for Self-Acquisition of Resting 12-Lead ECGs

We have developed a dry-electrode harness that permits easy, rapid, and unsupervised self-acquisition of resting 12-lead ECGs without the use of any disposables. Various other advantageous features of the harness include: 1) padded or inflatable cushions at the lateral sides of the torso that function to press the left arm (LA) and right arm (RA) dry electrodes mounted on cushions against sideward (as shown in the Figure below) or downward-rested arms of the subject; 2) sufficient distal placement of the arm electrodes with good abutment and without the need for adhesives, straps, bands, bracelets, or gloves on the arms; 3) padding over the sternum to avoid "tenting" in the V1 through V3 (and V3R, when present) electrode positions; 4) easy-to-don, one-piece design with an adjustable single point of connection and an adjustable shoulder strap; and 5) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar lead placements.

Schlegel, T. T.↗

Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

Researchers at NASA s Johnson Space Center and at Orbital Research, Inc. (a NASA SBIR grant recipient) have recently developed a dry-electrode harness that allows for self-acquisition of resting 12-lead ECGs by minimally trained laypersons. When used in conjunction with commercial wireless (e.g., Bluetooth(TM) or 802.11-enabled) 12-lead ECG devices and custom smart phone-based software, the collected 12-lead ECG data can also immediately be forwarded from any geographic location within cellular range to the user s physician(s) of choice. The system can also be used to immediately forward to central receiving stations 12-lead ECG data collected during space flight or during activities in any remote terrestrial location supported by an internet or cellular phone infrastructure. The main novel aspects of the system are first, the dry-electrode 12-lead ECG harness itself, and second, an accompanying Android(TM) smart phone-based wireless 12-lead ECG capability. The ECG harness nominally employs dry electrodes manufactured by Orbital Research, Inc, recently cleared through the Food and Drug Administration (FDA). However, other dry electrodes that are not yet FDA cleared, for example those recently developed by Nanosonic, Inc as part of another NASA SBIR grant, can also be used. The various advantageous features of the harness include: 1) laypersons can be quickly instructed on its correct use, remotely if necessary; 2) all tangled "leadwire spaghetti" is eliminated, as is the common clinical problem of "leadwire reversal"; 3) all adhesives and disposables are also eliminated, the harness being fully reusable; if multiple individuals intend to use use the same harness, then standard antimicrobial wipes can be employed to sterilize the dry electrodes (and harness surface if needed) between users; 5) padded cushions at the lateral sides of the torso function to press the left arm (LA) and right arm (RA) dry electrodes mounted on the cushions against sideward or downward-rested arms of the subject; 6) sufficient distal placement of the arm electrodes achieves good electrode abutment to the arms without the need for adhesives, straps, bands, bracelets, or gloves; 7) padding over the sternum avoids "tenting" in the V1 through V3 (and, when present, the V3R) electrode positions; 8) easy-to-don, one-piece design with an adjustable, front-side single point of connection and an adjustable shoulder strap; and 9) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar placements. The main limitation of the harness is that "one size does not fit all", meaning that an appropriately sized harness (small, medium, large, etc) must be chosen on the basis of an individual's size. To facilitate the use of the harness with inexpensive, commodity-grade cell phones and tablet devices, 12-lead ECG software is also being developed to accompany the harness for wireless use with Android. For this part of the project, NASA has teamed with TopCoder, Inc and the Harvard-affiliated NASA Tournament Lab in sponsoring java-based software programming contests through TopCoder. While ECG signals from the harness can already be wirelessly received and thoroughly processed (locally or remotely) by commercial-grade conventional (as well as advanced) 12-lead ECG software running on Microsoft Windows(TM), the Android-based software, once completed, will "cast a wider net" by allowing for a greater percentage of cell phone owners to participate in inexpensive, store-and-forward recordings of 12-lead ECGs worldwide, including for example Android cell phone users in many remote, third-world locations. At the time of writing, the Android 12-lead ECG software platform consists of a basic but expanding graphical user interface and accompanying software that: 1) wirelessly receives the 12-lead ECG data stream from a Bluetooth-based, FDA-cleared 12-leaCG device attached to the harness; 2) locally stores the same data in binary format to the SD card on the Android cell phone; and 3) makes the data stream in available in real time, for now to TopCoder's java programming contestants.

Schlegel, Todd T.↗

A multimodal and integrated approach to interrogate human kidney biopsies with rigor and reproducibility: guidelines from the Kidney Precision Medicine Project

Comprehensive and spatially mapped molecular atlases of organs at a cellular level are a critical resource to gain insights into pathogenic mechanisms and personalized therapies for diseases. The Kidney Precision Medicine Project (KPMP) is an endeavor to generate three-dimensional (3-D) molecular atlases of healthy and diseased kidney biopsies by using multiple state-of-the-art omics and imaging technologies across several institutions. Obtaining rigorous and reproducible results from disparate methods and at different sites to interrogate biomolecules at a single-cell level or in 3-D space is a significant challenge that can be a futile exercise if not well controlled. Here we describe a “follow the tissue” pipeline for generating a reliable and authentic single-cell/region 3-D molecular atlas of human adult kidney. Our approach emphasizes quality assurance, quality control, validation, and harmonization across different omics and imaging technologies from sample procurement, processing, storage, shipping to data generation, analysis, and sharing. We established benchmarks for quality control, rigor, reproducibility, and feasibility across multiple technologies through a pilot experiment using common source tissue that was processed and analyzed at different institutions and different technologies. A peer review system was established to critically review quality control measures and the reproducibility of data generated by each technology before their being approved to interrogate clinical biopsy specimens. The process established economizes the use of valuable biopsy tissue for multiomics and imaging analysis with stringent quality control to ensure rigor and reproducibility of results and serves as a model for precision medicine projects across laboratories, institutions and consortia.

59 BASIC BIOLOGICAL SCIENCES↗

A Phenomenological Model for Cavitation

A phenomenological model of cavitation is presented, based on observations that both large relative negative pressures and large negative time derivatives of pressure are required for cavitation onset. We simulated two cavitation experiments to generate cavitation scaling parameters for relative pressure drop and rate of pressure drop. Our results show the model, while simple, is effective at reproducing results from laboratory experiments of cavitation. The parameters were then used in conjunction with a human surrogate computational model to predict, at any position within the head, the probability of intracranial cavitation caused by exposure to a blast event. The results suggest that the magnitude of blast overpressure observed in field data is sufficient to cause intracranial cavitation. Our analysis indicates that the helmeted head, when compared to the unhelmeted head configuration, results in a decrease but not elimination of cavitation exposure. When density functions of cavitation probability versus cumulative brain volume are combined with an injury severity model, the results show helmet efficacy at low and moderate risk levels. However, the convergence of unhelmeted and helmeted probability density functions at high-to-excessive risk thresholds indicates the helmet offers diminishing protection at elevated exposure levels, relative to the unhelmeted baseline. Future investigation and collaboration with neuroscience subject matter experts are needed to contextualize the current computational results. While the present work contributes specific and quantified predictions of intracranial cavitation location and severity, more research is required to apply our results to clinical settings with population-based brain injury subjects and controls. The relationship between our intracranial cavitation predictions with their anticipated clinical sequelae remains a topic in need of exploration.

60 APPLIED LIFE SCIENCES↗

Charge coupled devices

The results are presented of a program to design, fabricate, and test CCD arrays suitable for operation in an electron-bombarded mode. These intensified charge coupled devices have potential application to astronomy as photon-counting arrays. The objectives of this program were to deliver arrays of 250 lines of 400 pixels each and some associated electronics. Some arrays were delivered on tube-compatible headers and some were delivered after incorporation in vacuum tubes. Delivery of these devices required considerable improvements to be made in the processing associated with intensified operation. These improvements resulted in a high yield in the thinning process, reproducible results in the accumulation process, elimination of a dark current source in the accumulation process, solution of a number of header related problems, and the identification of a remaining major source of dark current. Two systematic failure modes were identified and protective measures established. The effects of tube processing on the arrays in the delivered ICCDs were determined and are reported along with the characterization data on the arrays.

Walker, J. W.↗

Surface tension of natural silicate melts from 1,200-1,500 C and implications for melt structure

The surface tension between silicate liquid and gas is measured for four lava compositions (limburgite to andesite) from 1,200 to 1,500 C. It is noted that the magnitude of surface tension (gamma) is in the range 350-370 dynes/cm. Variations found in gamma as a function of liquid composition are small and have no obvious relation to liquid composition. Gamma is also found to vary little with furnace atmosphere - air, Ar, CO2, H2, CO and their mixtures. It is found that a relaxation time of hours to days, depending on temperature, is required before reproducible results can be obtained from originally crystalline starting material. The reproducible temperature dependence of gamma for complex silicate liquid solution is found to be small, positive, and a relatively simple function of liquid composition.

Walker, D.↗