High Energy Experimental Research Effort: Intensity Frontier Physics with Liquid Argon Time Projection Chambers (Final Technical Report DE-SC0017925)

The proposal “University of Florida High Energy Physics Intensity Frontier Research: Liquid Argon Detectors” requested one year of funding support for the PI, one postdoc and one graduate student to start their involvement in ongoing and upcoming experiments that use Liquid Argon Time Projection Chambers (LAr TPCs) to reconstruct neutrino interactions. Specifically, it was proposed that the group join the Short Baseline Near Detector (SBND) at Fermilab and that the PI continue their involvement in the Deep Underground Neutrino Detector (DUNE).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Submerged Medium Voltage Cable Systems at Nuclear Power Plants: A Review of Research Efforts Relevant to Aging Mechanisms and Condition Monitoring

In a submerged environment, power cables may experience accelerated insulation degradation due to water-related aging mechanisms. Direct contact with water or moisture intrusion in the cable insulation system has been identified in the literature as a significant aging stressor that can affect performance and lifetime of electric cables. Progressive reduction of the dielectric strength is commonly a result of water treeing which involves the development of permanent hydrophilic structures in the insulation coinciding with the absorption of water into the cable. Water treeing is a phenomenon in which dendritic microvoids are formed in electric cable insulation due to electrochemical reactions, electromechanical forces, and diffusion of contaminants over time. These reactions are caused by the combined effects of water presence and high electrical stresses in the material. Water tree growth follows a tree-like branching pattern, increasing in volume and length over time. Although these cables can be “dried out,” water tree degradation, specifically the growth of hydrophilic regions, is believed to be permanent and typically worsens over time. Based on established research, water treeing or water induced damage can occur in a variety of electric cables including XLPE, TR-XLPE and other insulating materials, such as EPR and butyl rubber. Once water trees or water induced damage form, the dielectric strength of an insulation material will decrease gradually with time as the water trees grow in length, which could eventually result in failure of the insulating material. Under wet conditions or in submerged environments, several environmental and operational parameters can influence water tree initiation and affect water tree growth. These parameters include voltage cycling, field frequency, temperature, ion concentration and chemistry, type of insulation material, and the characteristics of its defects. In this effort, a review of academic and industrial literature was performed to identify: 1) findings regarding the degradation mechanisms of submerged cabling and 2) condition monitoring methods that may prove useful in predicting the remaining lifetime of submerged medium voltage power cables. The research was conducted by a multi-disciplinary team, and sources included official NRC reports, national laboratory reports, IEEE standards, conference and journal proceedings, magazine articles, PhD dissertations, and discussions with experts. The purpose of this work was to establish the current state-of-the-art in material degradation modeling and cable condition monitoring techniques and to identify research gaps. Subsequently, future areas of focus are recommended to address these research gaps and thus strengthen the efficacy of the NRC’s developing cable condition monitoring program. Results of this literature review and details of the testing recommendations are presented in this report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modbus RTU for Embedded Cyber Secure Inverter Controller

The Modbus communication protocol is a widely adopted communication standard in industrial control systems. This communication protocol is known for being reliable and straightforward to implement while being versatile in terms of its operating parameters while supporting multiple formats over various hardware infrastructures and architectures. Many intelligent devices such as Programmable Logic Controllers (PLCs), Human-Machine Interfaces (HMIs), Internet-of-Things (IoT), and various Operational Technologies (OT) utilize Modbus for their communication systems. These types of systems must communicate with each other through a standardized and central communication process. To support the integration of these modular systems, a Field-Programmable Gate Array (FPGA) can act as an embedded central routing fabric for this communication to take place. Embedded systems are versatile enough to interface with various devices and systems to accomplish various goals. Additionally, embedded systems require relatively small physical designs to minimize the required resources to facilitate the intended application by providing low-level system access. This minimization of system resources goes hand in hand with reducing the financial cost of a proposed solution or system. As remotely collaborating researchers often use FPGAs to prototype designs that are required to have a method for data transmission among systems, it is imperative to provide a baseline standard for communications among devices and systems. A typical method of implementing the Modbus RTU communication protocol in an embedded environment is using integrated logic architectures within the FPGA called “Intellectual Property (IP) cores.” IP cores can be designed using integrated logic or circuit designs to function as an embedded processor. These IP cores can then perform the required computational actions to support the Modbus RTU communication protocol by utilizing high-level programming languages such as the C programming language. The hardware description language of Very High-Speed Integrated Circuit Hardware Description Language (VHDL) allows for the control of real hardware at the logic gate and signal level. These logic gates and signals can be designed and controlled to perform desired actions based on the system design. Programming an FPGA using VHDL allows an individual to access the lowest abstraction level of the system during FPGA development. This level of abstraction is referred to as the register-transfer level (RTL), which gives access to manipulating values and variables at the register level. This register-level manipulation provides precision over creating the logical circuit within the FPGA, thus minimizing the required code to perform desired operations. The Modbus RTU communication protocol can be implemented within an FPGA using VHDL programming to establish a standardized and embedded serial communication pathway. This implementation provides a standardized communication protocol to streamline research efforts among researchers, thus increasing the efficiency of research efforts. Additionally, this Modbus RTU implementation requires fewer resources when compared to typical communication protocol implementations that utilize an IP core, reducing the hardware requirement for effective research efforts.

communication↗

Key materials of vanadium flow batteries: electrolytes

Electrolytes not only dictates the device performance, but also the major part of VRFB system cost, making it as main focus of extensive research efforts in this field. Most research efforts directed towards finding an optimal supporting electrolyte and/or additive materials, which can increase the vanadium cations solubility and stability. Current research efforts were mostly trial and error methods, yielding marginal improvements in chemical/thermal stability while potentially compromising on other functional properties such as conductivity and viscosity. In addition, any supporting electrolyte and/or additives used to enhance vanadium solubility or cell potential will eventually diffuse across the membrane making it necessary to be compatible with both half-cell reactions to ensure long battery life. Another aspect of ensuring longer battery life cycle with minimum self-discharge of VRFB would be the additive/supporting electrolyte should exhibit prolonged thermal and chemical stability, typically over 30 days at battery operating temperature of -5 to 50 C. These practical requirements may limit the implementation of many additives currently under investigation. Despite extensive research, identifying the optimal material for stabilizing the vanadium electrolyte has been rather slow owing to the widely used empirical approach.

Murugesan, Vijayakumar↗

Mitigation of methane emissions in cities: How new measurements and partnerships can contribute to emissions reduction strategies

Cities generate 70% of anthropogenic greenhouse gas emissions, a fraction that is grow-ing with global urbanization. While cities play an important role in climate change mitigation, there has been little focus on reducing urban methane (CH4) emissions. Here, we develop a conceptual framework for CH 4 mitigation in cities by describing emission processes, the role of measurements, and a need for new institutional partnerships. Urban CH 4 emissions are likely to grow with expanding use of natural gas and organic waste disposal systems in growing population centers; however, we currently lack the ability to quantify this increase. We also lack systematic knowledge of the relative contribution of these distinct source sectors on emissions. We present new observations from four North American cities to demonstrate that CH4 emissions vary in magnitude and sector from city to city and hence require different mitigation strategies. Detections of fugitive emissions from these systems suggest that current mitiga- tion approaches are absent or ineffective. These findings illustrate that tackling urban CH 4 emissions will require research efforts to identify mitigation targets, develop and implement new mitigation strategies, and monitor atmospheric CH 4 levels to ensure the success of mitigation efforts. This research will require a variety of techniques to achieve these objectives and should be deployed in cities globally. In conclusion, we suggest that metropolitan scale partnerships may effectively coordinate systematic measurements and actions focused on emission reduction goals.