Robust Automated Residual Motion Correction for Repeat Pass SAR
No abstract available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
This article presents a measurement of the proper motion of the Ursa Minor dwarf spheroidal galaxy determined from images taken with the Hubble Space Telescope in two distinct fields. Each field contains a quasi-stellar object that serves as the "reference point". Integrating the motion of Ursa Minor in a realistic potential for the Milky Way produces orbital elements. The perigalacticon and apogalacticon are 40 (10, 76) and 89 (78, 160) kpc, respectively, where the values in the parentheses represent the 95% confidence intervals derived from Monte Carlo experiments. The eccentricity of the orbit is 0.39 (0.09, 0.79), and the orbital period is 1.5 (1.1, 2.7) Gyr. The orbit is retrograde and inclined by 124 degrees (94 deg, 36 deg ) to the Galactic plane. Ursa Minor is not a likely member of a proposed stream of galaxies on similar orbits around the Milky Way, nor is the plane of its orbit coincident with a recently proposed planar alignment of galaxies around the Milky Way. Comparing the orbits of Ursa Minor and Carina shows no reason for the different star formation histories of these two galaxies. Ursa Minor must contain dark matter to have a high probability of having survived disruption by the Galactic tidal force until the present.
This is part two of a series on the optical modeling activities for JWST. Starting with the linear optical model discussed in part one, we develop centroid and wavefront error sensitivities for the special case of a segmented optical system such as JWST, where the primary mirror consists of 18 individual segments. Our approach extends standard sensitivity matrix methods used for systems consisting of monolithic optics, where the image motion is approximated by averaging ray coordinates at the image and residual wavefront error is determined with global tip/tilt removed. We develop an exact formulation using the linear optical model, and extend it to cover multiple field points for performance prediction at each instrument aboard JWST. This optical model is then driven by thermal and dynamic structural perturbations in an integrated modeling environment. Results are presented.
Progress in the construction of the fundamental catalogs allows one to ask the following questions: 'Now that we have the FK5 with which to measure by, how good was the FK4? The FK3? How realistic were the error estimates they gave for their equatorial coordinates and their proper motions? Have their residual systematic differences continued to decrease in amplitude?' and so forth. Similar questions could be asked of the GC and the N30, and a companion paper will similarly analyze them. Finally, the identical series of questions could be asked of the AGK2, AGK3, AGK3U sequence. In this paper we develop a general method to objectively investigate, post facto, the true quality of star catalog error estimates. We present a complete mathematical formulation of the questions above and delineate the calculations needed to address them. Our initial numerical applications are restricted to a straightforward examination of the mean errors of the coordinates and proper motions in the FK3 (using the FK4 and the FK5 for comparison) and in the FK4 (using the FK5 for comparison). However, we can simply and consistently interpret the results of these computations -- for the FK catalogs fail to follow the predictions of mathematical statistics -- only if the FK3 and the FK4 contain higher angular frequency systematic errors. These errors, at the mean epochs of place of the older catalogs, are larger than the random errors in the FK5 system. We expect that our new ability to discern these features means that we can also prevent them during compilation. Finally, note that the concepts behind our procedures are completely general and can be applied to any set of compiled data -- astrometric, photometric, geodetic, and so forth.
Aircraft flight along parabolic trajectories have been proposed and executed in order to achieve low cost, near free fall conditions of moderate duration. This paper describes a six degree of freedom experiment isolation system designed to cancel out residual accelerations due to mechanical vibrations and errors in aircraft trajectory. The isolation system consists of a fine motion magnetic levitator whose stator is transported by a conventional coarse motion stage. The levitator uses wide gap voice coil actuators and has the dual purpose of isolating the experiment platform from aircraft vibrations and actively cancelling residual accelerations through feedback control. The course motion stage tracks the levitated platform in order to keep the levitator's coils centered within their matching magnetic gaps. Aspects of system design, an analysis of the proposed control strategy and simulation results are presented. Feasibility experiments are also discussed.
The National Meteorological Center Barotropic-Mesh Model has been used to test a statistical correction procedure, designated as M-II, that was developed in Schemm et al. (1981). In the present application, statistical corrections at 12 h resulted in significant reductions of the mean-square errors of both vorticity and the Laplacian of thickness. Predictions to 48 h demonstrated the feasibility of applying corrections at every 12 h in extended forecasts. In addition to these improvements, however, the statistical corrections resulted in a shift of error from smaller to larger-scale motions, improving the smallest scales dramatically but deteriorating the largest scales. This effect is shown to be a consequence of randomization of the residual errors by the regression equations and can be corrected by spatially high-pass filtering the field of corrections before they are applied.
A flight assessment has been made of a system for measuring the three components of atmospheric turbulence in the frequency range associated with airplane motions (0 to approximately 0.5 Hz). Results of the assessment indicate acceptable accuracy of the resulting time histories and power spectra. Small residual errors at the airplane short period and Dutch roll frequencies (0.5 and 0.25 Hz, respectively), as determined from in-flight maneuvers in smooth air, would not be detectable on the power spectra. However, errors at approximately 0.25 Hz can be present in the time history of the lateral turbulence component, particularly at the higher altitudes where airplane yawing motions are large. An assessment of the quantities comprising the vertical turbulence component leads to the conclusion that the vertical component is essentially accurate to zero frequency.
Two different Earth-pointing missions dealing with attitude control and dynamics changes illustrate concerns with correlated error sources and coupled effects that can occur. On the OrbView-2 (OV-2) spacecraft, the assumption of a nearly-inertially-fixed momentum axis was called into question when a residual dipole bias apparently changed magnitude. The possibility that alignment adjustments and/or sensor calibration errors may compensate for actual motions of the spacecraft is discussed, and uncertainties in the dynamics are considered. Particular consideration is given to basic orbit frequency and twice orbit frequency effects and their high correlation over the short science observation data span. On the Tropical Rainfall Measuring Mission (TRMM) spacecraft, the switch to a contingency Kalman filter control mode created changes in the pointing error patterns. Results from independent checks on the TRMM attitude using science instrument data are reported, and bias shifts and error correlations are discussed. Various orbit frequency effects are common with the flight geometry for Earth pointing instruments. In both dual-spin momentum stabilized spacecraft (like OV-2) and three axis stabilized spacecraft with gyros (like TRMM under Kalman filter control), changes in the initial attitude state propagate into orbit frequency variations in attitude and some sensor measurements. At the same time, orbit frequency measurement effects can arise from dynamics assumptions, environment variations, attitude sensor calibrations, or ephemeris errors. Also, constant environment torques for dual spin spacecraft have similar effects to gyro biases on three axis stabilized spacecraft, effectively shifting the one-revolution-per-orbit (1-RPO) body rotation axis. Highly correlated effects can create a risk for estimation errors particularly when a mission switches an operating mode or changes its normal flight environment. Some error effects will not be obvious from attitude sensor measurement residuals, so some independent checks using imaging sensors are essential and derived science instrument attitude measurements can prove quite valuable in assessing the attitude accuracy.
Astrometric VLBI observations of radio stars are being made to connect the Hipparcos optical reference frame and the extragalactic radio reference frame. The antennas are switched between a star and a strong, compact reference source a few degrees away every 2-3 minutes. After correlation, the strong reference source fringes are used to determine the exact delay and rate of the weak radio star fringes, allowing the visibilities to be measured and coherently integrated for the duration of the experiment. As a result accurate astrometry has been possible on radio stars with flux densities as low as 2 mJy. All five astrometric parameters (two positions, two proper motions, and one parallax) have been obtained for several stars, with formal errors and epoch-to-epoch residuals less than 1 milliarcsecond.
Since 1988, various experiments have shown that the TV signals transmitted by direct TV satellites may easily be used to perform time transfers at the level of a few tens of nanoseconds, the main source of error being the uncertainty on the satellite position. We first present the two methods used in our experiment to reduce the effects of the satellite residual motion: the first one consists in estimating the longitude variations of the satellite and then using this information to improve other measurements. This allows reducing the uncertainty to values between 9 and 50 nanoseconds according to the position of the involved stations. In the second method we determine the satellite position by using the data collected by three calibrated stations. Time transfer between each of these stations and a fourth one has been shown to be achievable at the precision level of ten nanoseconds. A new approach based on the use of a Kalman filter is proposed in order to take into account the dynamics of the geostationary satellite. The precisions on orbital elements and clock differences and rates determination given by the first simulated applications of the Kalman filter are presented and compared to those obtained by the other methods.
The causes and effects of diurnal polar motion are described. An algorithm is developed for modeling the effects on very long baseline interferometry observables. Five years of radio-frequency very long baseline interferometry data from stations in Massachusetts, California, and Sweden are analyzed for diurnal polar motion. It is found that the effect is larger than predicted by McClure. Corrections to the standard nutation series caused by the deformability of the earth have a significant effect on the estimated diurnal polar motion scaling factor and the post-fit residual scatter. Simulations of high precision very long baseline interferometry experiments taking into account both measurement uncertainty and modeled errors are described.
The method utilizes computer programs developed for the forthcoming ATS-F/NIMBUS-F tracking and data relay experiment where the basic tracking measurements are multiple path round-trip propagation times and rates. This method of orbit computation has recently been successfully evaluated by tracking a geostationary satellite (ATS-3) using an existing VHF (150 MHz) network of automatic transponders. A master station sequentially interrogates each transponder via the ATS-3. The master site is located at Schenectady, N. Y. and four automatic transponders were located at Shannon, Reykajavik, Buenos Aires, and Seattle respectively. Data at hourly intervals were collected during a 24 hour period on April 18-19, 1973. After correcting this data for known systematic errors it was provided as input to an orbit determination program where all satellite motions during signal propagation are rigorously accounted for. The resulting estimated ATS-3 orbit yielded observational residuals on the order of 100 meters. By using more than one satellite the present scheme is further capable of accurately locating several stationary or mobile terminals as part of the overall orbital solution.
Four-component, three-axis, feedback-controlled seismograph incorporates electronic circuitry for leveling and for monitoring the feedback signal required for servo-centering. Viscous damping of the earth-motion signal, compensation of the residual long-term drift, and centering of the seismometers are provided by automatic mechanisms.
We describe the calibration and data processing methods used to generate full-sky maps of the cosmic microwave background (CMB) from the first year of Wilkinson Microwave Anisotropy Probe (WMAP) observations. Detailed limits on residual systematic errors are assigned based largely on analyses of the flight data supplemented, where necessary, with results from ground tests. The data are calibrated in flight using the dipole modulation of the CMB due to the observatory's motion around the Sun. This constitutes a full-beam calibration source. An iterative algorithm simultaneously fits the time-ordered data to obtain calibration parameters and pixelized sky map temperatures. The noise properties are determined by analyzing the time-ordered data with this sky signal estimate subtracted. Based on this, we apply a pre-whitening filter to the time-ordered data to remove a low level of l/f noise. We infer and correct for a small (approx. 1 %) transmission imbalance between the two sky inputs to each differential radiometer, and we subtract a small sidelobe correction from the 23 GHz (K band) map prior to further analysis. No other systematic error corrections are applied to the data. Calibration and baseline artifacts, including the response to environmental perturbations, are negligible. Systematic uncertainties are comparable to statistical uncertainties in the characterization of the beam response. Both are accounted for in the covariance matrix of the window function and are propagated to uncertainties in the final power spectrum. We characterize the combined upper limits to residual systematic uncertainties through the pixel covariance matrix.
The SOUP experiment on Spacelab 2 includes a 30 cm visible light telescope and focal plane package mounted on the Instrument Pointing System (IPS). Scientific goals of the experiment dictate pointing stability requirements of less than 0.05 arcsecond jitter over periods of 5-20 seconds. Quantitative derivations of these requirements from two different aspects are presented: (1) avoidance of motion blurring of diffraction-limited images; (2) precise coalignment of consecutive frames to allow measurement of small image differences. To achieve this stability, a fine guider system capable of removing residual jitter of the IPS and image motions generated on the IPS cruciform instrument support structure has been constructed. This system uses solar limb detectors in the prime focal plane to derive an error signal. Image motion due to pointing errors is compensated by the agile secondary mirror mounted on piezoelectric transducers, controlled by a closed-loop servo system.
The rotational orientation (Universal Time and the variation of latitude at McDonald Observatory, Texas) of the earth has been determined between mid 1970 and mid 1982 from McDonald Observatory lunar laser ranging (LLR) data. Universal Time, UT1, is calculated and supplied in three forms, the raw daily decomposition values, the Gaussian filtered values and the Fourier smoothed values. Formal error estimates are available for all three types. LLR can calculate corrections to one component of polar motion, the variation of latitude at McDonald Observatory. Modelling improvements have been applied here and a significant drop is seen in the residuals. The rms weighted residual for the entire thirteen year data span (3,326 'normal' points acquired between August 1969 and May 1982) is 18.7 cm.
A document discusses a mechanism that uses flex-pivots in a parallelogram arrangement to provide frictionless motion with an unlimited lifetime. A voicecoil actuator drives the parallelogram over the required 5-cm travel. An optical position sensor provides feedback for a servo loop that keeps the velocity within 1 percent of expected value. Residual tip/tilt error is compensated for by a piezo actuator that drives the interferometer mirror. This mechanism builds on previous work that targeted ground-based measurements. The main novelty aspects include cryogenic and vacuum operation, high reliability for spaceflight, compactness of the design, optical layout compatible with the needs of an imaging FTS (i.e. wide overall field-of-view), and mirror optical coatings to cover very broad wavelength range (i.e., 0.26 to 15 m).
The 1982-1983 El Nino/Southern Oscillation (ENSO) event was accompanied by the largest interannual variation in the Earth's rotation rate on record. In this study we demonstrate that atmospheric forcing was the dominant cause for this rotational anomaly, with atmospheric angular momentum (AAM) integrated from 1000 to 1 mbar (troposphere plus stratosphere) accounting for up to 92% of the interannual variance in the length of day (LOD). Winds between 100 and 1 mbar contributed nearly 20% of the variance explained, indicating that the stratosphere can play a significant role in the Earth's angular momentum budget on interannual time scales. Examination of LOD, AAM, and Southern Oscillation Index (SOI) data for a 15-year span surrounding the 1982-1983 event suggests that the strong rotational response resulted from constructive interference between the low-frequency (approximately 4-6 year) and quasi-biennial (approximately 2-3 year) components of the ENSO phenomenon, as well as the stratospheric Quasi-Biennial Oscillation (QBO). Sources of the remaining LOD discrepancy (approximately 55 and 64 microseconds rms residual for the European Centre for Medium-Range Forecasting (EC) and U.S. National Meteorological Center (NMC) analyses) are explored; noise and systematic errors in the AAM data are estimated to contribute 18 and 33 microseconds, respectively, leaving a residual (rms) of 40 (52) microseconds unaccounted for by the EC (NMC) analysis. Oceanic angular momentum contributions (both moment of inertia changes associated with baroclinic waves and motion terms) are shown to be candidates in closing the interannual axial angular momentum budget.