Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Role of Gas in Determining Image Quality and Resolution During In Situ Scanning Transmission Electron Microscopy Experiments

As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelastic scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. We demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A high-stability scanning tunneling microscope achieved by an isolated tiny scanner with low voltage imaging capability

We present a novel homebuilt scanning tunneling microscope (STM) with high quality atomic resolution. It is equipped with a small but powerful GeckoDrive piezoelectric motor which drives a miniature and detachable scanning part to implement coarse approach. The scanning part is a tiny piezoelectric tube scanner (industry type: PZT-8, whose d{sub 31} coefficient is one of the lowest) housed in a slightly bigger polished sapphire tube, which is riding on and spring clamped against the knife edges of a tungsten slot. The STM so constructed shows low back-lashing and drifting and high repeatability and immunity to external vibrations. These are confirmed by its low imaging voltages, low distortions in the spiral scanned images, and high atomic resolution quality even when the STM is placed on the ground of the fifth floor without any external or internal vibration isolation devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-27: Shifting Multiple EPID Imager Layers to Improve Image Quality and Resolution in MV CBCT

Purpose: Vertical stacking of four conventional EPID layers can improve DQE for MV-CBCT applications. We hypothesize that shifting each layer laterally by half a pixel relative to the layer above, will improve the contrast-to-noise ratio (CNR) and image resolution. Methods: For CNR assessment, a 20 cm diameter digital phantom with 8 inserts is created. The attenuation coefficient of the phantom is similar to lung at the average energy of a 6 MV photon beam. The inserts have attenuations 1, 2…8 times of lung. One of the inserts is close to soft tissue, resembling the case of a tumor in lung. For resolution assessment, a digital phantom featuring a bar pattern is created. The phantom has an attenuation coefficient similar to soft tissue and the bars have an attenuation coefficient of calcium sulfate. A 2 MeV photon beam is attenuated through these phantoms and hits each of the four stacked detector layers. Each successive layer is shifted by half a pixel in the x only, y only, and x and y (combined) directions, respectively. Blurring and statistical noise are added to the projections. Projections from one, two, three and four layers are used for reconstruction. CNR and image resolution are evaluated and compared. Results: When projections from multiple layers are combined for reconstruction, CNR increases with the number of layers involved. CNR in reconstructions from two, three and four layers are 1.4, 1.7 and 1.99 times that from one layer. The resolution from the shifted four layer detector is also improved from a single layer. In a comparison between one layer versus four layers in this preliminary study, the resolution from four shifted layers is at least 20% better. Conclusion: Layer-shifting in a stacked EPID imager design enhances resolution as well as CNR for half scan MV-CBCT. The project described was supported, in part, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Cleaned 5-Minute Resolution Air Quality and Meteorological Data from Nine TCEQ CAMS Sites in Houston, Texas (Nov 2021 – Oct 2022)

These data encompass 5-minute air monitoring and meteorological observations collected in the greater Houston, Texas metropolitan region, at nine (9) Continuous Ambient Monitoring Stations (CAMS) operated by the Texas Commission on Environmental Quality (TCEQ) between November 1, 2021 and October 31, 2022. The CAMS sites (CAMS 1, 8, 35, 45, 148, 403, 405, 410, and 1052) were chosen because their instrumentation includes measurements of PM2.5. These sites also provide continuous multi-parameter air-quality and meteorological measurements. Particulate matter (PM2.5, PM10) was sampled along with several trace gases, including ozone (O3), nitrogen oxides (NO, NO2, NOx), sulfur dioxide (SO2), and carbon monoxide (CO). The data set also contains standard surface meteorological parameters (temperature, humidity, pressure, wind speed, and wind direction). Several sites also include AutoGC-based measurements of volatile organic compounds (VOCs). Air monitoring instruments deployed at the selected sites comprise the following systems: BAM-1020 or TEOM (PM2.5), Thermo Scientific TEI 49i (O3), TEI 42i (NOx), and AutoGCs (VOCs). This data set is similar to the data included within the houairq5mX1.00 datastream, except for a few additional quality control steps. A systematic data cleaning and verification process was performed on the data set to ensure its quality and preparation for analysis. Removal of non-numeric status flags (e.g., [LIM], [QAS], [SPZ], [CAL], [PMA], [AQI], [SPN], [MAL]) was accomplished by employing rule-based string parsing to extract valid numerical values. Missing entries were set to -9999; however, invalid or anomalous values (e.g., 99999) were retained as originally reported by the TCEQ to preserve data provenance. The time sequence was verified for completeness, removal of duplicates, and uniformity at 5-minute intervals. Column labeling was standardized, and corresponding values were assessed for physical plausibility. All timestamps in the data set were reported in Coordinated Universal Time (UTC) as provided by the TCEQ. Further, the latitude and longitude coordinates were added for each CAMS site. A subset of the data (June 1–September 30, 2022) has been used in the following publication: Subba et al. 2025. “Implications of sea breeze circulations on boundary layer aerosols in the southern coastal Texas region.” EGUsphere 2025: 1–49, https://doi.org/10.5194/egusphere-2025-2659.

latitude↗

Quantitative metrics for assessment of chemical image quality and spatial resolution

Rationale: Currently objective/quantitative descriptions of the quality and spatial resolution of mass spectrometry derived chemical images are not standardized. Development of these standardized metrics is required to objectively describe chemical imaging capabilities of existing and/or new mass spectrometry imaging technologies. Such metrics would allow unbiased judgment of intra-laboratory advancement and/or inter-laboratory comparison for these technologies if used together with standardized surfaces. Methods: We developed two image metrics, viz., chemical image contrast (ChemIC) based on signal-to-noise related statistical measures on chemical image pixels and corrected resolving power factor (cRPF) constructed from statistical analysis of mass-to-charge chronograms across features of interest in an image. These metrics, quantifying chemical image quality and spatial resolution, respectively, were used to evaluate chemical images of a model photoresist patterned surface collected using a laser ablation/liquid vortex capture mass spectrometry imaging system under different instrument operational parameters. Results: The calculated ChemIC and cRPF metrics determined in an unbiased fashion the relative ranking of chemical image quality obtained with the laser ablation/liquid vortex capture mass spectrometry imaging system. These rankings were used to show that both chemical image contrast and spatial resolution deteriorated with increasing surface scan speed, increased lane spacing and decreasing size of surface features. Conclusions: ChemIC and cRPF, respectively, were developed and successfully applied for the objective description of chemical image quality and spatial resolution of chemical images collected from model surfaces using a laser ablation/liquid vortex capture mass spectrometry imaging system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performances of a new generation tracking detector: the MEG II cylindrical drift chamber

Abstract The cylindrical drift chamber is the most innovative part of the MEG II detector, the upgraded version of the MEG experiment. The MEG II chamber differs from the MEG one because it is a single volume cylindrical structure, instead of a segmented one, chosen to improve its resolutions and efficiency in detecting low energy positrons from muon decays at rest. In this paper, we show the characteristics and performances of this fundamental part of the MEG II apparatus and we discuss the impact of its higher resolution and efficiency on the sensitivity of the MEG II experiment. Because of its innovative structure and high quality resolution and efficiency the MEG II cylindrical drift chamber will be a cornerstone in the development of an ideal tracking detector for future positron-electron collider machines.

Physics↗

Resolution of the Electron Microscope at the Atomic Scale

The importance of atomic-resolution electron microscopy as a tool for structure analysis lies in its ability to produce images in which each peak corresponds to the position of an atom (or atomic column) within the specimen. Being able to distinguish between atoms (or columns) that appear close together when projected in the chosen viewing direction depends on the resolution of the microscope. Knowledge of the resolution of any particular electron microscope is crucial to judge if its resolution is appropriate for the specimen. In addition, resolution quality will determine the precision of measured atom positions.

A-OK↗

Enhancing trap and fault seal analyses by integrating observations from HR3D seismic data with well logs and conventional 3D seismic data, Texas inner shelf

An understanding of trap and fault seal quality is critical for assessing hydrocarbon prospectivity. To achieve this, modern analytical techniques leverage well data and conventional industry-standard 3D seismic data to evaluate the trap, and any faults displacing the reservoir and top seal intervals. Above all, geological interpretation provides the framework of trap and fault seal analyses, but can be hindered by the data resolution, quality and acquisition style of the conventional seismic data. Furthermore, limiting the analysis to only the petroleum system at depth may lead to erroneous perceptions because interpreting overburden features, such as shallow faults or gas chimneys, can provide valuable observations with respect to container performance, and can to help validate trap and fault seal predictions. Here, a supplement to conventional 3D data are high-resolution 3D seismic (HR3D) data, which provide detailed images of the overburden geology. This study utilizes an HR3D seismic volume in the San Luis Pass area of the Texas inner shelf, where shallow fault tips and a sizeable gas chimney are interpreted over an unsuccessful hydrocarbon prospect. Static post-drill fault seal and trap analyses suggest that the primary fault displacing the structural closure could have withheld columns of gas c. 100 m high, but disagree with our HR3D seismic interpretations and dry-well analyses. From our results, we hypothesize that tertiary gas migration through fault conduits reduced the hydrocarbon column in the prospective Early Miocene reservoir, and may have resulted from continued movement along the intersecting faults. Overall, this study reinforces the importance of understanding the overburden geology and geohistory of faulted prospects, and demonstrates the utility of pre-drill HR3D acquisition when conducting trap and fault seal analyses.

3D seismic↗

A HYBRID SOLAR WIND MODEL OF THE CESE+HLL METHOD WITH A YIN-YANG OVERSET GRID AND AN AMR GRID

A hybrid three-dimensional (3D) MHD model for solar wind study is proposed in the present paper with combined grid systems and solvers. The computational domain from the Sun to Earth space is decomposed into the near-Sun and off-Sun domains, which are respectively constructed with a Yin-Yang overset grid system and a Cartesian adaptive mesh refinement (AMR) grid system and coupled with a domain connection interface in the overlapping region between the near-Sun and off-Sun domains. The space-time conservation element and solution element method is used in the near-Sun domain, while the Harten-Lax-Leer method is employed in the off-Sun domain. The Yin-Yang overset grid can avoid well-known singularity and polar grid convergence problems and its body-fitting property helps achieve high-quality resolution near the solar surface. The block structured AMR Cartesian grid can automatically capture far-field plasma flow features, such as heliospheric current sheets and shock waves, and at the same time, it can save significant computational resources compared to the uniformly structured Cartesian grid. A numerical study of the solar wind structure for Carrington rotation 2069 shows that the newly developed hybrid MHD solar wind model successfully produces many realistic features of the background solar wind, in both the solar corona and interplanetary space, by comparisons with multiple solar and interplanetary observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Joint X-ray and neutron refinement with phenix.refine

The implementation of crystallographic structure-refinement procedures that include both X-ray and neutron data (separate or jointly) in the PHENIX system is described. Approximately 85% of the structures deposited in the Protein Data Bank have been solved using X-ray crystallography, making it the leading method for three-dimensional structure determination of macromolecules. One of the limitations of the method is that the typical data quality (resolution) does not allow the direct determination of H-atom positions. Most hydrogen positions can be inferred from the positions of other atoms and therefore can be readily included into the structure model as a priori knowledge. However, this may not be the case in biologically active sites of macromolecules, where the presence and position of hydrogen is crucial to the enzymatic mechanism. This makes the application of neutron crystallography in biology particularly important, as H atoms can be clearly located in experimental neutron scattering density maps. Without exception, when a neutron structure is determined the corresponding X-ray structure is also known, making it possible to derive the complete structure using both data sets. Here, the implementation of crystallographic structure-refinement procedures that include both X-ray and neutron data (separate or jointly) in the PHENIX system is described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stereolithographic Fabrication of a Flow Cell For Improved Neurochemical Sensor Testing

The human brain remains a mystery to researchers. Scientists at Lawrence Livermore National Laboratory (LLNL) have developed highly sensitive and flexible multimodal multielectrode arrays (MEAs) with the potential to be both powerful diagnostic and therapeutic tools when dealing with neurological ailments such as Alzheimers, Parkinson’s, Post Traumatic Stress Disorder, and Traumatic Brain Injuries. These MEAs include biosensors in addition to electrodes for electrical stimulation and recording. The transition from the traditional rigid neural probes to the flexible MEAs has led LLNL researchers on the search for alternative testing and characterization methods for flexible devices in vitro. The rigid devices have been shown to be more abrasive and damaging to the brain when implanted, but due to their rigidity – are more robust and resilient to noise artifacts in in vitro testing. The flexible MEAs, similar in size and flexibility to a human hair, cause much less damage in the brain but have had a difficult time maintaining their integrity and collecting data without high-levels of noise due to the formation of inertial eddies (due to increased turbulent flow) moving the flexible MEA during in vitro testing. The goal of this project was to design a fluidic cell to allow for a more constant electrochemical testing & characterization of biosensors on these flexible MEAs. Design and fabrication of the fluidic cell was through the use of CAD software and a stereolithography printer using clear photopolymer resin (appropriate for biomedical use and quality resolution). Flow cells facilitate analyte delivery to biosensor surfaces in a more constant and controlled fashion, allowing for –in this case –a better electrodeposition of thin-film Platinum-Iridium (Pt-Ir) on MEAs of 16 Platinum disc electrodes 50µm in diameter. Platinum-Iridium alloy electrodes have been widely used in biomedical and industrial applications. Iridium adds mechanical stiffness to platinum. PtIr is a FDA approved electrode material for human implantable devices.

36 MATERIALS SCIENCE↗

Data for Renewable Energy Planning, Policy, and Investment

Reliable, robust, and validated data are critical for informed planning, policy development, and investment in the clean energy sector. The Renewable Energy (RE) Explorer was developed to support data-driven renewable energy analysis that can inform key renewable energy decisions globally. This document presents the types of geospatial and other data at the core of renewable energy analysis and decision making. Individual data sets used to inform decisions vary in relation to spatial and temporal resolution, quality, and overall usefulness. From Data to Decisions, a complementary geospatial data and analysis decision guide, provides an in-depth view of these and other considerations to enable data-driven planning, policymaking, and investment. Data support a wide variety of renewable energy analyses and decisions, including technical and economic potential assessment, renewable energy zone analysis, grid integration, risk and resiliency identification, electrification, and distributed solar photovoltaic potential. This fact sheet provides information on the types of data that are important for renewable energy decision making using the RE Data Explorer or similar types of geospatial analysis tools.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Production of the thermal scattering law and neutron scattering cross sections for ice from first principles - 14503

Water ice can exist in many polymorphic phases as a result of the wide range of geometric ordering possible for the hydrogen bonds between H{sub 2}O molecules. Ice Ih, which can form under normal atmospheric pressure at 273 K, is the most common type. Ab initio density functional theory, incorporating the generalized gradient approximation (GGA) for the exchange-correlation energy, is used to simulate the hexagonal structure of ice Ih and calculate phonon dispersion relations with harmonic lattice dynamics. While the unit cell for ice Ih contains four molecules with particular alignments of the H{sub 2}O molecules possible, the structure has globally disordered proton arrangement. To improve capturing this random distribution, a 12-molecule unit cell is incorporated along with a 2x2x2 supercell. The total phonon density of states is determined by randomly sampling dispersion relations in the first Brillouin zone. The translational, librational, bending, and stretching modes are produced with high-quality resolution and are consistent with the optical peaks and ranges observed in Raman, infrared, and inelastic neutron scattering experiments [1]. The phonon spectrum is used to calculate the S(α,β) thermal scattering law for ENDF [2] publication in the incoherent approximation, which is appropriate due to the relatively small coherent nuclear scattering cross section for H{sub 2}O. These theoretical results are compared to experimental S(α,β) at 268 K [3] and trends are found to be in good agreement. Finally, total scattering cross sections are calculated by integrating over S(α,β) to determine the incoherent inelastic cross sections and then separately adding the absorption and incoherent elastic components. These results are compared to experimental total cross sections for ice Ih at 115 K over a range of incident energies [4] and found to provide excellent agreement. (authors)

42 ENGINEERING↗

The effect of horizontal resolution on simulation quality in the Community Atmospheric Model, CAM5.1

We present an analysis of version 5.1 of the Community Atmospheric Model (CAM5.1) at a high horizontal resolution. Intercomparison of this global model at approximately 0.25°, 1°, and 2° is presented for extreme daily precipitation as well as for a suite of seasonal mean fields. In general, extreme precipitation amounts are larger in high resolution than in lower-resolution configurations. In many but not all locations and/or seasons, extreme daily precipitation rates in the high-resolution configuration are higher and more realistic. The high-resolution configuration produces tropical cyclones up to category 5 on the Saffir-Simpson scale and a comparison to observations reveals both realistic and unrealistic model behavior. In the absence of extensive model tuning at high resolution, simulation of many of the mean fields analyzed in this study is degraded compared to the tuned lower-resolution public released version of the model.

58 GEOSCIENCES↗

Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm{sup 2} and the total size of the detector head is 47.8 × 46.3 mm{sup 2}. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗