Direct imaging of neural currents using ultra-low field magnetic resonance techniques

Using resonant interactions to directly and tomographically image neural activity in the human brain using magnetic resonance imaging (MRI) techniques at ultra-low field (ULF), the present inventors have established an approach that is sensitive to magnetic field distributions local to the spin population in cortex at the Larmor frequency of the measurement field. Because the Larmor frequency can be readily manipulated (through varying B.sub.m), one can also envision using ULF-DNI to image the frequency distribution of the local fields in cortex. Such information, taken together with simultaneous acquisition of MEG and ULF-NMR signals, enables non-invasive exploration of the correlation between local fields induced by neural activity in cortex and more `distant` measures of brain activity such as MEG and EEG.

60 APPLIED LIFE SCIENCES↗

Optical properties of WO{sub 3} thin films using surface plasmon resonance technique

Indigenously assembled surface plasmon resonance (SPR) technique has been exploited to study the thickness dependent dielectric properties of WO{sub 3} thin films. WO{sub 3} thin films (80 nm to 200 nm) have been deposited onto gold (Au) coated glass prism by sputtering technique. The structural, optical properties and surface morphology of the deposited WO{sub 3} thin films were studied using X-ray diffraction, UV-visible spectrophotometer, Raman spectroscopy, and Scanning electron microscopy (SEM). XRD analysis shows that all the deposited WO{sub 3} thin films are exhibiting preferred (020) orientation and Raman data indicates that the films possess single phase monoclinic structure. SEM images reveal the variation in grain size with increase in thickness. The SPR reflectance curves of the WO{sub 3}/Au/prism structure were utilized to estimate the dielectric properties of WO{sub 3} thin films at optical frequency (λ = 633 nm). As the thickness of WO{sub 3} thin film increases from 80 nm to 200 nm, the dielectric constant is seen to be decreasing from 5.76 to 3.42, while the dielectric loss reduces from 0.098 to 0.01. The estimated value of refractive index of WO{sub 3} film is in agreement to that obtained from UV-visible spectroscopy studies. The strong dispersion in refractive index is observed with wavelength of incident laser light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of alkali–silica reaction damage in concrete using linear and nonlinear resonance techniques

Here in this study, the initiation and development of alkali–silica reaction (ASR) in concrete prisms containing reactive coarse (RCA) and reactive fine (RFA) aggregates were monitored over one year using linear and nonlinear resonance techniques. Although the linear resonance test could detect initiation and development of ASR damage in RCA specimens, it failed in the RFA specimens. Petrographic analysis confirmed the presence of early-stage ASR damage and the presence of different microcracking patterns in the RFA and RCA specimens, which may explain differences in the linear resonance data. For both RCA and RFA specimens, the nonlinear resonance test results were able to detect the initiation of ASR damage and showed a strong correlation with the ASR expansion for all specimens from different mix designs. The results demonstrate the high sensitivity of the nonlinear resonance test and its potential for quantitative evaluation of the ASR damage state of concrete specimens without a baseline measurement.

36 MATERIALS SCIENCE↗

Prompt quality monitoring of InSe and GaSe semiconductor crystals by the nuclear quadrupole resonance technique

To determine the quality of layer-structured semiconductor single crystals, the nuclear quadrupole resonance technique with successive scanning of the entire sample volume and assessment of the structural quality on the basis of the observed spectra is used. The proposed method is appropriate in the case of InSe, GaSe and GaAs ingots grown in evacuated cells by the Bridgman technique and can be used repeatedly in subsequent technological procedures with no operator access to the material. To provide scanning within a limited region of the sample and to ensure efficient interaction of the high-frequency field with the crystal, excitation and detection of the nuclear-spin-induction signal is implemented by the saddle-shaped transceiver coil of the nuclear quadrupole resonance spectrometer.

36 MATERIALS SCIENCE↗

Ultrasonic Resonance Techniques for Materials Research

Mechanical resonances are directly related to the physical behavior of a system at the bulk and microscopic levels. In materials science, resonant ultrasound spectroscopy (RUS) has long been a preferred nondestructive method to study mechanical resonances of solids and precisely measure quantitative material properties, namely elasticity. In recent years, advances in computational power and hardware have enabled RUS to be relevant for an increasing range of applications, such as advanced manufacturing. An extension of this technique, nonlinear RUS (NRUS), has been demonstrated to provide unmatched sensitivity to early-stage damage. NRUS was originally developed to probe geologic materials but has become a vital tool in nondestructive evaluation and materials research, offering a powerful means of quantifying and characterizing microstructural nonlinearity in a broad range of materials. This review summarizes recent developments and growth opportunities in RUS and NRUS techniques, modeling, and applications across a wide range of material systems including metals, composites, geomaterials, and explosives.

36 MATERIALS SCIENCE↗

Dynamics of fluorinated imide-based ionic liquids using nuclear magnetic resonance techniques

There is increasing interest in studying molecular motions in ionic liquids to gain better insights into their transport properties and to expand their applications. Here, in this study, we have employed the fast field cycling relaxometry and pulsed field gradient nuclear magnetic resonance techniques to investigate the rotational and translational dynamics of fluorinated imide-based ionic liquids (ILs) at different temperatures. We have studied a total of six ILs composed of the 1-butyl-3-methylimidazolium cation ([BMIM] + ) combined with chemically modified analogs of the bis((trifluoromethyl)sulfonyl)imide anion ([NTf 2 ] − or [TFSI] − ). The primary objective of this paper is to broaden the understanding of how the anion's conformational flexibility, fluorination, and mass affect the molecular dynamics of cations and anions. Our results indicate that flexibility has the most significant impact on the rotational and translational motions of ions. Meanwhile, the effect of fluorination and mass is only relevant when conformational flexibility does not change significantly between the ILs being compared.

25 ENERGY STORAGE↗

A biofilm microreactor system for simultaneous electrochemical and nuclear magnetic resonance techniques

In order to fully understand electrochemically active biofilms and the limitations to their scale-up in industrial biofilm reactors, a complete picture of the microenvironments inside the biofilm is needed. Nuclear magnetic resonance (NMR) techniques are ideally suited for the study of biofilms and for probing their microenvironments because these techniques allow for non-invasive interrogation and in situ monitoring with high resolution. By combining NMR with simultaneous electrochemical techniques, it is possible to sustain and study live electrochemically active biofilms. Here, we introduce a novel biofilm microreactor system that allows for simultaneous electrochemical and NMR techniques (EC-NMR) at the microscale. Microreactors were designed with custom radiofrequency resonator coils, which allowed for NMR measurements of biofilms growing on polarized gold electrodes. For an example application of this system, we grew Geobacter sulfurreducens biofilms. NMR was used to investigate growth media flow velocities, which were compared to simulated laminar flow, and electron donor concentrations inside the biofilms. We use Monte Carlo error analysis to estimate standard deviations of the electron donor concentration measurements within the biofilm. The EC-NMR biofilm microreactor system can ultimately be used to correlate extracellular electron transfer rates with metabolic reactions and explore extracellular electron transfer mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strain-tunable microwave-resonance technique for quantum materials

By integrating a dielectric microwave resonator with a piezoelectric-based strain device, we develop an in situ strain-tunable microwave spectroscopy technique that enables contactless measurements of material properties under strain. To demonstrate the capability of this device, we measure the strain-dependent microwave surface impedance of the representative iron-based superconductor Ba⁢Fe 2 (As 1−𝑥 ⁢P 𝑥 ) 2 at the slightly overdoped composition. We successfully control and observe the suppression of superconductivity under both compressive and tensile anisotropic lattice distortions along the tetragonal [110] T direction, as manifested by changes in the quality factor and resonance frequency shifts of microwave resonance. Furthermore, strain-induced changes in microwave surface resistivity, an extension of conventional DC-limit transport elastoresistivity to the microwave regime, provide information on electronic anisotropy equivalent to that of DC elastoresistivity, while offering a contactless alternative. Furthermore, our strain-tunable cavity therefore serves as a powerful, contactless probe of fundamental material properties under strain and may also potentially facilitate the design of hybrid quantum systems with strain-engineered quantum degrees of freedom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling and characterizing the elastodynamic response of octet-truss lattice structures using resonance techniques

Characterization of additively manufactured materials and structures is an ongoing effort for the advanced manufacturing community. This article will investigate an approach using resonant spectral ultrasound (RUS) to measure the effective elastic constants of an Octet Truss lattice and apply the results to continuum bases models representing the lattice regions in different structures. The study is focused on simple lattices structures fabricated from Ti5553 using a laser powder bed fusion process (LBPF). Solid and lattice samples are measured to determine RUS estimates for the elastic properties of the bulk material and the effective elastic properties of the lattice structure. The estimated elastic properties are then incorporated into 3d finite element models using a continuum approximation of the physical AM parts. Comparisons show good agreement between the experimentally measured eigen frequencies of the Ti5553 LBPF parts and the eigen frequencies calculated using the continuum approximations based on the effective RUS elastic properties. The current results suggest there is additional physics and geometrical effects that are accounted for in the RUS continuum approximation of the lattice that are not captured in the full 3d finite element model of the parts utilizing only the base material properties.

36 MATERIALS SCIENCE↗

Insights into Rotational and Translational Dynamics in Mixtures of Ethylene Glycol and Choline Chloride Using Nuclear Magnetic Resonance Techniques

This work examines molecular dynamics and interactions in ethylene glycol–choline chloride (EG–ChCl) mixtures across 0–33 mol % ChCl, spanning the true eutectic region near 17–20 mol % and the commonly used 1:2 formulation. We combine pulsed-field-gradient (PFG) diffusion, fast-field-cycling (FFC) relaxometry, temperature-dependent 13 C T 1 , and nuclear Overhauser effect spectroscopy (NOESY) to disentangle local from macroscopic dynamics. PFG and FFC show that both translational and average rotational motions largely track the strong increase in viscosity with ChCl content, with ethylene glycol consistently diffusing faster than the choline cation and no global dynamical anomaly at the eutectic composition. More subtle, site-specific composition effects nevertheless emerge. The ratio of the diffusion coefficient of the hydroxyl group of choline to the diffusion coefficient of the methyl group of choline displays a shallow minimum in the 17–25 mol % region, indicating a modest change in how the hydroxyl-bearing end of choline samples the underlying translational motion relative to the methyl groups. 13 C T 1 analysis shows that rotational correlation times at 25 °C generally increase with ChCl, reflecting viscosity-coupled slowing, while the CH 2 –N α site exhibits a small but reproducible deviation from this monotonic trend near the eutectic. NOESY spectra at similar compositions reveal enhanced cross-relaxation between EG and choline protons, consistent with increased headgroup–solvent contact density rather than a wholesale structural rearrangement. Overall, our multitechnique study demonstrates that EG–ChCl dynamics are predominantly viscosity-dominated, with the eutectic region acting as a subtle dynamical crossover where specific choline segments become maximally coupled to the hydrogen-bond network. These insights refine the structure–dynamics picture of choline-chloride DESs and provide practical guidance for tuning composition in electrochemical, separation, and catalytic applications.

diffusion↗

Following the Transient Reactions in Lithium-Sulfur Batteries Using In an In Situ Nuclear Magnetic Resonance Technique

Li-S batteries hold great potential for next-generation, large-format power source applications; yet, the fundamental understanding of the electrochemical reaction pathways remains lacking to enable their functionality as promised. Here, in situ NMR technique employing a specially designed cylindrical micro battery was used to monitor the chemical environments around Li+ ions during repetitive charge-discharge process and track the transient electrochemical and chemical reactions occurring in the whole Li-S system. The in situ NMR provides real time, quantitative information related to the temporal concentration variations of the polysulfides with various chain lengths, providing important clues for the reaction pathways during both discharge and charge processes. The in-situ technique also reveals that redox reactions may involve transient species that are difficult to detect in ex-situ NMR study. Intermediate species such as charged free radicals may play an important role in the formation of the polysulfide products. Additionally, in situ NMR measurement simultaneously reveals vital information on the 7Li chemical environments in the electrochemical and parasitic reactions on the lithium anode that promotes the understanding of the failure mechanism in the Li-S system. These new insights could help design effective strategies to accelerate the development of Li-S battery technology.

Environmental Molecular Sciences Laboratory↗

Resonance Inspection Techniques & Analysis (RITA)

Resonance Inspection encompasses a suite of techniques for the purpose of materials characterization and nondestructive evaluation. These techniques utilize the mechanical resonances of the sample(s) to determine and monitor material properties (e.g., elastic moduli, phase changes), sort mechanically defective parts, determine the presence/level of mechanical damage (micro-cracking, delaminations, disbonding, etc.) and monitor mass/density fluctuations to name a few applications. The Resonance Inspection Techniques & Analyses (RITA) system has been developed to facilitate these and other applications in a user friendly and cost effective package.

Ulrich II, Timothy↗

Conduction-Electron Spin Resonance in HgSe Crystals

Samples of a gapless HgSe semiconductor with different iron impurity concentrations are investigated. HgSe:Fe samples are examined by the electron-spin-resonance technique. Multiple resonance lines caused by unpaired spins of different origins are analyzed. The properties of electrons localized at shallow impurities are described using a hydrogen-like model. The effect of an internal field on the resonance lines is established. It is found that the conduction of HgSe is not only nonparabolic, but also nonspherical.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Study on New Isotope Analysis Technique with Resonance Ionization Mass Spectrometry Using Inductively Coupled Plasma as an Atomic Source (ICP-RIMS)

We have proposed the novel isotope analysis technique with Resonance Ionization Mass Spectrometry using Inductively Coupled Plasma as an atomic source (ICP-RIMS). Each component of ICP-RIMS is conceptually designed. We conclude that the orthogonal acceleration time-of-flight mass spectrometer (oa-TOF-MS) driven by a high-repetition-rate pulsed laser would be suitable system for ICP-RIMS. We, additionally, suggest that the first vacuum stage of the vacuum interface, which is between the sampling and skimmer cones, is desired to maintain as low pressure as possible in order to suppress the Doppler broadening and to skim the supersonic jet effectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resonant acoustic monitoring of damage in plug‐screw feeders

Abstract Plug‐screw feeders are critical in many industrial processes for compressing slurry materials via a rotating plug‐screw feeder. Over time, increasing plug‐screw feeder wear will eventually lead to catastrophic mechanical failure. Early detection of the wear state can prevent unplanned catastrophic failures resulting in operational shut‐downs, costly repairs, and most importantly the health and safety of workers. We present a theoretical basis for a noninvasive, in operando acoustic resonant technique to monitor the wear state of plug‐screw feeders. The technique is based on tracking the resonant acoustic modes of the plug‐screw feeder, which are sensitive to the plug‐screw feeder geometry, material, and operating conditions. We implemented a multivariate polynomial model to estimate the plug‐screw feeder wear state using multiple acoustic resonances by simulating the acoustic resonant modes for two categories of wear (tip and thread damage) that are common in plug‐screw feeders. Fitting multiple resonances to the polynomial model, we demonstrate accurate estimation of the total mass loss, as well as characterization of the type of damage (i.e., tip vs. thread). Current approaches for monitoring plug‐screw feeder wear rely on shutting down the operation and visually inspecting the plug‐screw feeder. The presented acoustic technique offers a noninvasive, in operando measurement approach that mitigates unplanned catastrophic failures. The acoustic resonance technique presented in the paper has a broad range of industrial applications including the Pharmaceutical, Mining, Integrated Biorefineries (IBR), and Additive Manufacturing industries, to name a few.

36 MATERIALS SCIENCE↗

Characterization of the Properties of Barium–Strontium Titanate Films and Controlled Elements Based on Them in the Frequency Range of 1–60 GHz

The electrical properties of barium–strontium titanate films and tunable capacitors based on them are studied in a wide frequency range. The dielectric losses in ferroelectric films at frequencies up to 30 GHz are estimated based on the parameters of capacitors measured using various resonance techniques. Direct measurements of the properties of the films were carried out at a frequency of 60 GHz using the open-resonator technique. Based on the comparison with semiconductor analogues, the prospects of using thin-film ferroelectric elements in the millimeter-wavelength range are shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗