Search NASA⌕ Search

SEARCH · Search NASA

Results for “resonant frequency of SRF cavities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

CHARACTERIZING AND CONTROLLING RECOVERY AND RECRYSTALLIZATION IN NIOBIUM FOR IMPROVED SRF CAVITY PERFORMANCE

Crystal defects, such as dislocations and low-angle boundaries, provide sources of magnetic flux trapping in the Nb materials used for superconducting radio frequency (SRF) resonating cavities. Improving the performance of SRF cavities, as measured through the quality factor, requires reducing these defects. SRF cavity production involves deformation processing, such as rolling and forming, and strategic annealing heat treatments. The resulting microstructures can be recovered, recrystallized, or both. Because recovery leaves many defects that can trap flux, recrystallization should improve cavity performance. Thus, processing schedules that produce complete recrystallization without excessive grain growth need to be designed. Solutions to this problem require understanding physical metallurgy and differentiating between recovered and recrystallized regions of microstructure. Backscattered electron microscopy techniques are applied to this end. We demonstrate that the conditions required to produce fully recrystallized microstructures depend on Nb impurity content, suggesting that processing schedules may need to be adjusted by material heat or lot. We also demonstrate that processing can be used to control growth of recrystallized grains to maintain mechanical strength in fully recrystallized materials. Forming cavities from cold-rolled Nb sheet material may provide strategic new routes to obtain microstructures that improve SRF cavity performance.

Taleff, E. [The University of Texas at Austin]↗

Electromagnetic response of disordered superconducting cavities

We present the results for the resonant frequency shift and quality factor of disordered niobium (Nb) superconducting radio-frequency cavities driven out of equilibrium by the resonant microwave field. The theory is based on the non-equilibrium theory of superconductivity for the current response to the electromagnetic field at the vacuum–metal interface. We are able to accurately predict the observed frequency shifts with a precision of order fractions of kHz over the full temperature range 0 < T ≤ T c , including the negative frequency shift anomalies that are observed very near T c . The origin of these anomalies is shown to be the competition between the normal metal skin depth and the London penetration depth, which diverges as T→T c ⁻. An analytical approximation to the full current response, valid for |T-Tc| $\ll$ Tc, accounts for the negative frequency shift near T c . The non-monotonic dependence of the quality factor on the quasiparticle scattering rate is related to the pair-breaking effect of disorder on the superfluid fraction and, thus, the London penetration depth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development and characterization of Nb3Sn/Al2O3 superconducting multilayers for particle accelerators

Abstract Superconducting radio-frequency (SRF) resonator cavities provide extremely high quality factors > 10 10 at 1–2 GHz and 2 K in large linear accelerators of high-energy particles. The maximum accelerating field of SRF cavities is limited by penetration of vortices into the superconductor. Present state-of-the-art Nb cavities can withstand up to 50 MV/m accelerating gradients and magnetic fields of 200–240 mT which destroy the low-dissipative Meissner state. Achieving higher accelerating gradients requires superconductors with higher thermodynamic critical fields, of which Nb 3 Sn has emerged as a leading material for the next generation accelerators. To overcome the problem of low vortex penetration field in Nb 3 Sn, it has been proposed to coat Nb cavities with thin film Nb 3 Sn multilayers with dielectric interlayers. Here, we report the growth and multi-technique characterization of stoichiometric Nb 3 Sn/Al 2 O 3 multilayers with good superconducting and RF properties. We developed an adsorption-controlled growth process by co-sputtering Nb and Sn at high temperatures with a high overpressure of Sn. The cross-sectional scanning electron transmission microscope images show no interdiffusion between Al 2 O 3 and Nb 3 Sn. Low-field RF measurements suggest that our multilayers have quality factor comparable with cavity-grade Nb at 4.2 K. These results provide a materials platform for the development and optimization of high-performance SIS multilayers which could overcome the intrinsic limits of the Nb cavity technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of Microphonic Effects on the C100 Cryomodule for High Energy Electron Beam Accelerators

The Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson National Laboratory (JLab) is a particle accelerator which can accelerate an electron beam to relativistic speeds and apply the beam onto target samples. The C100 superconducting radio frequency (SRF) cavity is the primary accelerating structure of the C100 cryomodule, one of the many cryomodules which compose the CEBAF linear accelerator. SRF cavities are particularly sensitive to internal and external vibrations that can result in a phenomenon called microphonics which degrade the operational stability of a cryomodule. The purpose of this thesis is to investigate the significance of mechanical disturbances on the electromagnetic resonant frequency of a C100 SRF cavity. Knowledge of the mechanical resonance of the cavities and cryomodule sheds light into how these disturbances are most easily realized as deformation which causes radio frequency (RF) detuning. Three studies were conducted: the development and hammer test calibration of a Finite Element Analysis (FEA) model of a C100 cavity, the development and hammer test calibration of an FEA model of a C100 cavity string, and the hammer test of the C100-10R cryomodule at the Cryomodule Test Facility (CMTF). The cavity FEA model was found to accurately predict two modes found in two real cavities in a simply supported configuration. The cavity string FEA model leveraged the calibrated cavity FEA model but was not found to accurately predict the modal behavior of a real cavity string. Even so, the modal behavior of the cavity string inside the C100-10R cryomodule was captured during a hammer test while it was partially assembled. Finally, the C100-10R cryomodule was placed in the CMTF to study RF detuning. The RF detuning spectra during hammer hits and background noise was captured. The results of the hammer testing indicate two strong peaks at low frequencies (9-10 Hz and 22-23 Hz). These two frequencies were found to be nearly coincident to four instances of mechanical resonance found during the hammer testing done on the partially-assembled C100-10R. Because of this, these two modes are believed to contribute to RF detuning of the cryomodule. This test event also included the testing of the effectiveness of a configuration of BNNT canisters designed to act as dampers. While these tests show promising results, the lurking variables render these tests somewhat inconclusive.

Hull, Caleb James↗

Cryogenic RF characterization of the MAGO cavity for high-frequency gravitational-wave detection

Superconducting radio-frequency (SRF) cavities are promising resonant sensors for gravitational-wave detection in the kHz-MHz frequency range. We report the cryogenic RF characterization of a prototype superconducting niobium cavity with an unconventional geometry designed for narrow electromagnetic mode separation. Following an adapted surface preparation procedure, cryogenic tests were performed at Fermilab and DESY at temperatures down to 2 K. Mechanical tuning at room temperature achieved a mode splitting of approximately 11 kHz at cryogenic temperature. High electromagnetic quality factors consistent with previous prototype cavities were measured. The measurements further revealed phase transfer characteristics relevant for stable low-level RF control as well as indications of mode coupling potentially caused by one-point multipacting. In addition, first cryogenic measurements of the mechanical eigenmodes yielded mechanical quality factors significantly below commonly assumed theoretical values. These results demonstrate the successful application of established SRF preparation and characterization techniques to a non-standard resonator geometry and provide important experimental input for the development of future SRF-based gravitational-wave detectors.

Dokuyucu, Can [DESY]↗

Direct current magnetic Hall probe technique for measurement of field penetration in thin film superconductors for superconducting radio frequency resonators

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently, high purity niobium is the material of choice for SRF cavities that have been optimized to operate near their theoretical field limits. This brings about the need for significant R & D efforts to develop next generation superconducting materials that could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under a high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate a superconductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements that are strongly influenced by the film orientation and shape and edge effects. In this work, we report the development of an experimental setup to measure the field of full flux penetration through films and multi-layered superconductors. Our system combines a small superconducting solenoid that can generate a magnetic field of up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the superconductor. We report this setup can be used to study alternative materials that could potentially outperform niobium, as well as superconductor–insulator–superconductor (SIS) multilayer coatings on niobium.

47 OTHER INSTRUMENTATION↗

Enhancing SRF cavity stability and minimizing detuning with data-driven resonance control based on dynamic mode decomposition

Effective resonance control of superconducting radio frequency (SRF) cavities is critical for large machines like LCLS-II, as failure to achieve proper control can result in increased RF power consumption, higher cryogenic heat loads, and increased costs. To address this challenge, we have developed a machine learning (ML) model based on the dynamic mode decomposition method to represent the forced cavity dynamics. Using this model, we designed a model predictive controller (MPC) and demonstrated through simulation that the MPC can effectively stabilize the amplitude and phase of SRF cavities using only a frequency actuator, even in the presence of multiple mechanical modes. The lightweight and explicit ML model makes the controller suitable for direct implementation on field-programmable gate arrays, unlocking the full potential of SRF linacs like LCLS-II, enabling higher beam power and energy, and also serving as an advanced motion controller for various applications, such as photon beamlines and storage rings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electromagnetic Response of Superconducting RF Cavities

Recently reported anomalies in frequency shift of order δƒ ~ 0.1–10 kHz for Niobium SRF cavities in a narrow temperature region near T c ≃ 9 K are sensitive to the surface preparation and Nitrogen doping. We developed methods for calculating the surface current response of Nb SRF cavities, as well as the resonant frequency shift and quality factor, as functions of temperature, frequency and disorder based on the Keldysh formulation of the theory for nonequilibrium superconductivity coupled with Maxwell’s theory and boundary conditions for the response functions and electromagnetic field. We show that the anomaly is sensitive to impurity disorder. Our results for the anomaly in the frequency shift are in good agreement with experimental results for Nb with an anisotropic gap on the Fermi surface and inhomogeneous non-magnetic disorder. We also show that the quality factor as a function of the impurity scattering rate is maximum for in SRF cavities with intermediate disorder, ℏ/τΔ~O(1) with the maximum $Q$ decreasing with increasing frequency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing Non-Equilibrium Pair-Breaking and Quasiparticle Dynamics in Nb Superconducting Resonators Under Magnetic Fields

We conducted a comprehensive study of the non-equilibrium dynamics of Cooper pair breaking, quasiparticle (QP) generation, and relaxation in niobium (Nb) cut from superconducting radio-frequency (SRF) cavities, as well as various Nb resonator films from transmon qubits. Using ultrafast pump–probe spectroscopy, we were able to isolate the superconducting coherence and pair-breaking responses. Our results reveal both similarities and notable differences in the temperature- and magnetic-field-dependent dynamics of the SRF cavity and thin-film resonator samples. Moreover, femtosecond-resolved QP generation and relaxation under an applied magnetic field reveals a clear correlation between non-equilibrium QPs and the quality factor of resonators fabricated by using different deposition methods, such as DC sputtering and high-power impulse magnetron sputtering. These findings highlight the pivotal influence of fabrication techniques on the coherence and performance of Nb-based quantum devices, which are vital for applications in superconducting qubits and high-energy superconducting radio-frequency applications.

43 PARTICLE ACCELERATORS↗

Study of Different Piezoelectric Material Stroke Displacement at Different Temperatures Using an SRF Cavity

Piezoelectric actuators are used for resonance control in superconducting linacs. The level of frequency compensation depends on the piezoelectric stroke displacement. In this study, the stroke displacement will be measured with a 1.3 GHz SRF cavity by measuring the frequency shift with respect to the voltage applied. The entire system was submerged in liquid helium. This study characterizes the PZT piezoelectric actuator (P-844K093) and a lithium niobate (P-844B0005) piezoelectric actuator. All these actuators were developed at Physik Instrumente (PI). The piezoelectric displacement was measured at different temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling frequency instability in high-quality resonant experiments

Modern resonant sensing tools can achieve increasingly high quality factors, which correspond to extremely narrow linewidths. In such systems, time variation of the resonator’s natural frequency can potentially impact its ability to accumulate power and its resulting sensitivity. One such example is the Dark SRF experiment, which utilizes superconducting radio frequency (SRF) cavities with quality factors of Q ∼ 10 10 . Microscopic deformations of the cavity lead to stochastic jittering of its resonant frequency with amplitude 20 times its linewidth. Naively, one may expect this to lead to a large suppression in accumulated power. In this work, we study in detail the effects of frequency instability on high-quality resonant systems, utilizing the Dark SRF experiment as a case study. We show that the timescale of jittering is crucial to determining its effect on power accumulation. Namely, when the resonant frequency varies sufficiently quickly, the system accumulates power as if there were no jittering at all. This implies that the sensitivity of a jittering resonator is comparable to that of a stable resonator. In the case of Dark SRF, we find that jittering only induces a ∼ 10 % loss in power. Our results allow the dark-photon exclusion bound from Dark SRF’s pathfinder run to be refined, leading to a constraint that is an order of magnitude stronger than previously reported (corresponding to a signal-to-noise ratio that is four orders of magnitude larger). This result represents the world-leading constraint on dark photons over a wide range of masses below 6 μ eV and translates to the best laboratory-based limits on the photon mass m γ < 2.9 × 10 - 48 g .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SRF Levitation and Trapping of Nanoparticles Experiment

The levitation and trapping of micro particles using lasers is not a new accomplishment and has been applied in containerless processing and spectroscopy of microparticles. Recent developments in the field of optomechanics have achieved levitating nanoparticles such that quantum phenomena was observed which would have relevance in quantum science and technology. This two-year project sought to levitate and trap mesoscopic particles using radio frequency (RF) fields in a resonating superconducting RF (SRF) cavity. By exploiting the intrinsic characteristics of an SRF resonating cavity, the project was to explore overcoming a major limit faced by current laser trapping techniques. The goal was to establish a foundation to enable the observation of quantum phenomena of an isolated mechanical oscillator interacting with microwave fields. If successful the experiment could establish its ground-breaking relevance to quantum information science and technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

VTS Dynamic Model and Experimental Validation for Vibration Suppression

High Q-factor superconducting radio-frequency (SRF) cavities are extremely sensitive to mechanical vibrations, which can cause an uncontrolled shift of the electromagnetic resonance frequency, with detrimental effects on the cavity performance. To avoid this phenomenon (i.e. microphonics) the dynamic behavior of the assembly must be studied, to design vibration suppression systems. In this paper, the numerical model of the Vertical Test Stand (VTS) insert adopted at the Fermi National Accelerator Laboratory for cold tests was studied, in the framework of the experimental characterization of Dark SRF cavities conducted by the SQMS (Superconducting Quantum Materials and Systems) center. Due to the complexity of the assembly, experimental activity is of utmost importance to validate the model. Thus, vibration testing was performed on the actual system, and a good correlation between numerical and experimental results was found. Additionally, two different setups were compared, with and without implementing a preliminary passive vibration suppression system, to assess its effectiveness in reducing the microphonics phenomenon. The obtained results allowed for the design of an improved isolation system, which will be the subject of future experimental testing.

43 PARTICLE ACCELERATORS↗

Coming Closer to High Frequency Gravitational Wave Detection With MAGO

In the last years, low frequency gravitational waves (GWs) have been consistently measured by the LIGO&#x2;Virgo collaboration, but little to no attention has been paid to higher frequencies GWs in the range of 10 kHz to 100 MHz, at which confirmation for current theories or even new physics could be hidden. The MAGO 2.0 project aims at filling this gap in the parameter space using superconducting radio-frequency (SRF) cavities. Exploiting the excellent Q-factors of these resonators, we plan to detect tiny harmonic deformations induced by GWs which change the boundary conditions of the oscillating electromagnetic field. We present the results of the first cold tests ran at DESY and FNAL using the cavity prototype built 20 years ago at the end of the MAGO collaboration, characterizing the RF spectrum, Q-factor and surface resistance. Additionally we introduce the mechanical vibration spectrum characterization and the RF response of the cavity with the injection of a “fake GW” signal using piezoelectric actuators.

Marconato, Giovanni [Hamburg U.]↗

Quantum-Enhanced Dark-Matter Sensing with Large Photon Number Fock States in a High-Q SRF Cavity

Wave-like dark matter candidates such as axions or dark photons in the microwave frequency range can be probed using resonant superconducting cavities. We demonstrate a quantum-enhanced sensing approach based on a multimode, high-Q superconducting RF (SRF) cavity, where a large Fock state is prepared in the storage mode via sideband transitions mediated by a transmon ancilla and a measurement-based feedforward protocol, achieving high-fidelity Fock states [1]. The prepared |n⟩ state induces stimulated emission from the dark-matter field, providing an (n + 1) enhancement in transition probability and proportional boost in signal rate [2]. A secondary cavity mode functions as an in-situ reference to calibrate noise. We present the control sequence, noise-referencing strategy, and projected sensitivity improvements for axion and dark-photon detection. This multimode architecture combines large Fock state preparation with noise calibration, offering a practical path to increased scan rate in cavity-based dark-matter searches.

Kim, Taeyoon↗

Simulated Lorentz Force Detuning Compensation With A Double Lever Tuner On A Dressed ILC/1.3 GHZ Cavity At Room Temperature

Pulsed SRF linacs with high accelerating gradients experience large frequency shifts caused by Lorentz force detuning (LFD). A piezoelectric actuator with a resonance control algorithm can maintain the cavity frequency at the nominal level, thus reducing the RF power. This study uses a double lever tuner with a piezoelectric actuator for compensation and another piezoelectric actuator to simulate the effects of the Lorentz force pulse. A double lever tuner has an advantage by increasing the stiffness of the cavity-tuner system, thus reducing the impact of LFD. The tests are conducted at room temperature and with a dressed 1.3 GHz 9-cell cavity.

43 PARTICLE ACCELERATORS↗

Quantum State Transfer between Heterogeneous 3D QPUs

We present detailed analyses and microwave simulations of a quantum interconnect architecture that couples two distinct three-dimensional quantum processing units (QPUs): (i) a two-cell superconducting radio-frequency (SRF) cavity coupled to multiple transmon qubits and (ii) a waveguide-based cavity hosting a planar circuit with transmons and resonators. The modules are linked via a low-loss superconducting coaxial cable, which serves as a quantum bus. Finite-element electromagnetic simulations are performed to optimize coupling strengths and mode frequencies for high-fidelity quantum state transfer between cavities. These simulation results provide a comprehensive blueprint for the experimental realization of a flexible quantum interconnect architecture, coupling heterogeneous QPUs.

Yaker, Joey [Fermilab]↗

AMR Magnetic Sensors in Flux Expulsion Studies

Magnetic flux expulsion properties of the superconducting material such as bulk niobium, widely used for the radio-frequency cavity fabrication, substantially affect the performance characteristics of the cavities. The quality factor of the SRF resonators can be significantly compromised due to the presence of the trapped flux vortices causing additional RF energy losses in the material. Large number of experiments have been carried out by different research groups to establish the correlation of the flux trapping in niobium cavities with the presence of impurities in niobium as well as various surface treatment methods. Majority of these experiments utilize commercially available cryogenic fluxgate magnetic sensors to measure the field before and after the niobium transition to the superconducting state to quantify the amount of flux trapped. One disadvantage of the typically used fluxgates is the size of the sensing volume. As an example, the Barting-ton F and G type cryogenic fluxgates have a sensing core length of about 30mm, which is comparable to the curvature radius of the cavity walls and hence the magnetic field lines curvature radius after the expulsion. Thus, the measured field value needs to be corrected to account for the sensor effective averaging over the sensing volume. In case of the sharper geometries, for instance if the flux expulsion to be measured on the edge of the rectangular niobium flat sheet with a thickness of ~5mm, the use of the fluxgate would be impractical.

Netepenko, A.↗