A resource adequacy assessment of correlated wide-area outages in the power grid

As the power grid is undergoing rapid transformations, numerous questions are emerging about its vulnerability to wide-area extreme events (WAEE), which could influence its operations. Relatively few analyses have been conducted to date regarding the impact of correlated outages during WAEEs on the grid’s ability to balance resources with demand. This study addresses this gap by conducting a resource adequacy analysis for a hurricane-inspired WAEE on a 2035 synthetic power grid system for the United States. A sensitivity analysis was also conducted to characterize the relative impact of weather on unserved energy. Our results indicate that although the magnitude and duration of the shortfalls vary depending on weather conditions, persistent shortfalls are observed in some regions. Initial explorations indicate a strong correlation between transmission-constrained regions and regions with persistent shortfalls. Future work could generate empirically-grounded representations for generator outages as well as conduct causal analyses of these shortfalls to improve understanding of drivers as well as possible mitigation strategies. Continued exploration of extreme weather impacts on the grid is important to develop more robust understanding of the reliability and resilience of our power systems, especially as they undergo rapid transformations.

24 POWER TRANSMISSION AND DISTRIBUTION

Electric Grid Reliability in an Era of Unprecedented Uncertainty: A Review of Advances in Electric Sector Resource Adequacy Assessment and Planning

Recent changes to the principal causes of energy shortage events on the electric grid have necessitated are thinking of paradigms for resource adequacy (RA) assessment and the related topic of procurement of a reliable portfolio. Prior studies have laid out elements of a modern paradigm for these planning activities, but there does not exist a comprehensive overview of the topic spanning academic and gray literature, and the relationship of these suggested paradigms to methods used in industry has also not been surveyed. In this paper we review recent literature establishing best practices for RA assessment and reliable portfolio procurement, and survey current practices used in industry in relation to these best practices. We establish seven key best practices for RA assessment, cover a modern methodology for capacity accreditation, and find that industry practices are not far behind the identified best practices, though some key gaps remain. We also present a suggested agenda for both academic research on the topic and opportunities for advancement in the industry.

24 POWER TRANSMISSION AND DISTRIBUTION

C4.jl [SWR-25-106]

A proof-of-concept software framework for integrating capacity expansion and production cost optimization with probabilistic resource adequacy assessment and sending feedback signals between the models.

Stephen, Gordon [National Renewable Energy Laborat

Endogenizing Probabilistic Resource Adequacy Risks in Deterministic Capacity Expansion Models

In this work, we demonstrate how power system capacity expansion models can understate the stochastic effects of thermal outages when considering resource availabilities on an hourly expected value basis, yielding system designs with multiple orders of magnitude more shortfall risk than stated adequacy targets. We develop a novel approximation approach to efficiently endogenize awareness of this risk in a deterministic, linear capacity expansion framework. We compare this approach to exogenous tuning of an energy reserve margin, the leading alternative method to compensate for unmodeled probabilistic shortfall risk. Empirical results from a test system show that the new endogenous method cost-effectively meets all regional reliability targets with a single optimization solve, and produces a near-identical system design as the incumbent method without the need for repeated re-optimizations to find an appropriate reserve level. The endogenous method may also use iterative re-optimizations to further improve solution quality, although these incremental benefits were modest in the system studied.

capacity expansion modeling

Probabilistic Grid Reliability Analysis with Energy Storage Systems

SAND2025-12025O The Probabilistic Grid Reliability Analysis with Energy Storage Systems (ProGRESS) software tool is an open-source tool for assessing the resource adequacy of the evolving electric power grid integrated with energy storage systems (ESS). This tool uses a simulation engine to create diverse scenarios that test the limits of the modern power grid consisting of a high-volume ESS and variable energy resources (VER). Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Nguyen, Tu

Empirical Assessment of Interregional Coordination to Support Resource Adequacy [Slides]

This study examines where interregional transmission could most effectively support resource adequacy in the contiguous United States. We use hourly load, renewable generation, and real-time price data from 2016–2023 for 18 planning subregions to identify periods of elevated adequacy risk, defined as the top 100 annual hours of net load and wholesale prices in each region. We then measure the temporal coincidence of these peak periods between adjacent regions and compare price patterns to assess the potential for capacity sharing. Results show that NorthernGrid West, a winter-peaking region, has low coincidence of peak net load with its summer-peaking neighbors, indicating high potential for interregional support. In contrast, regions in the Northeast have highly coincident peak periods, suggesting limited adequacy benefits from additional transmission. Price-based analysis shows peak-hour differences in the Midwest and between ERCOT and neighboring regions, indicating potential economic benefits from increased transfers. The findings provide an empirical screening of where transmission may offer the greatest reliability benefits without adding new generation capacity.

24 POWER TRANSMISSION AND DISTRIBUTION

Impact of hydropower availability on resource adequacy of the United States western interconnection

Hydropower is a key energy source in the western interconnection of the United States, comprising about 25% of the annual installed nameplate capacity in 2020. However, its generation is increasingly impacted by changing hydrological conditions, operational constraints, environmental factors, water availability, and aging dam infrastructure. Assessing hydropower availability and resource adequacy is valuable for shaping energy policies and infrastructure requirements. In this study we evaluate the sensitivity of resource adequacy in the Western Interconnection to the unavailability of hydropower plants, under a wide-ranging set of 16,384 hydropower loss scenarios derived from a combination of 14 major hydrologic regions. Although a complete loss of hydropower capacity in any region is unlikely, studying such scenarios helps in identifying hydrologic regions most critical for maintaining resource adequacy. So, we identify key hydrologic regions with disproportionately large adequacy impacts relative to their installed hydropower capacity and study compounding effects between regions using classification and regression trees. Even after controlling for total installed capacity, we find that hydropower resources in the Pacific Northwest contribute the most to interconnection-wide adequacy outcomes, with resources in Northern California and the Desert Southwest providing more moderate incremental contributions.

13 HYDRO ENERGY

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a realtime digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBRonly scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources: Preprint

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

User requirements and user acceptance of current and next-generation satellite mission and sensor complement, oriented toward the monitoring of water resources

Principal water resources users were surveyed to determine the applicability of remotely sensed data to their present and future requirements. Analysis of responses was used to assess the levels of adequacy of LANDSAT 1 and 2 in fulfilling hydrological functions, and to derive systems specifications for future water resources-oriented remote sensing satellite systems. The analysis indicates that water resources applications for all but the very large users require: (1) resolutions on the order of 15 meters, (2) a number of radiometric levels of the same order as currently used in LANDSAT 1 (64), (3) a number of spectral bands not in excess of those used in LANDSAT 1, and (4) a repetition frequency on the order of 2 weeks. The users had little feel for the value of new sensors (thermal IR, passive and active microwaves). What is needed in this area is to achieve specific demonstrations of the utility of these sensors and submit the results to the users to evince their judgement.

Castruccio, P. A.

Identifying Robust Decarbonization Pathways for the Western U.S. Electric Power System Under Deep Climate Uncertainty

Climate change threatens the resource adequacy of future power systems. Existing research and practice lack frameworks for identifying decarbonization pathways that are robust to climate-related uncertainty. We create such an analytical framework, then use it to assess the robustness of alternative pathways to achieving 60% emissions reductions from 2022 levels by 2040 for the Western U.S. power system. Our framework integrates power system planning and resource adequacy models with 100 climate realizations from a large climate ensemble. Climate realizations drive electricity demand; thermal plant availability; and wind, solar, and hydropower generation. Among five initial decarbonization pathways, all exhibit modest to significant resource adequacy failures under climate realizations in 2040, but certain pathways experience significantly less resource adequacy failures at little additional cost relative to other pathways. By identifying and planning for an extreme climate realization that drives the largest resource adequacy failures across our pathways, we produce a new decarbonization pathway that has no resource adequacy failures under any climate realizations. This new pathway is roughly 5% more expensive than other pathways due to greater capacity investment, and shifts investment from wind to solar and natural gas generators. Our analysis suggests modest increases in investment costs can add significant robustness against climate change in decarbonizing power systems. Our framework can help power system planners adapt to climate change by stress testing future plans to potential climate realizations, and offers a unique bridge between energy system and climate modeling.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power

Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.

capacity expansion model

Decarbonization and technology cost drivers: considerations for potential future thermoelectric water use in the power sector

The power sector is currently undergoing significant changes, driven by a combination of factors, including decarbonization and technology innovation. This study aims to assess implications of these drivers on U.S. power sector technology futures and the associated water and environmental implications for cooling thermoelectric power plants. Specifically, we evaluate four decarbonization scenarios for the contiguous United States that vary in assumptions concerning demand growth and technology costs, with technology costs driving alternative outcomes that prioritize either technologies that require low amounts of water (such as wind, solar, and battery) or high amounts of water (such as nuclear and carbon capture and storage). These scenarios are executed in a power sector capacity expansion model and compared to two reference scenarios that assume status quo with policy and cost drivers. Our analysis indicates that future U.S. thermoelectric water withdrawals could decrease by 25%–60%, but water consumption could more than triple in some scenarios. These changes are driven by a combination of retirement of some power facilities, shifts in cooling technologies, and new technology deployment. The water use patterns vary across the United States, with the eastern regions demonstrating a lot more variability in water consumption across scenarios than western regions. However, local concerns can influence these possible investments, since increased water consumption can exacerbate water scarcity, leading to conflicts among competing users and affecting regional social, environmental, and economic dynamics. Future work should consider possible costs associated with alternate water sources, as well as improve the representation of water constraints within simulations. Inclusion of extreme events and alternate modeling platforms (e.g. production cost modeling and resource adequacy) may also be warranted to further stress test the robustness of these possible technology futures. Such assessments will be critical for ensuring decarbonization and other infrastructure-oriented investments lead to a reliable and resilient power grid.

24 POWER TRANSMISSION AND DISTRIBUTION

Long-Duration Energy Storage Grid Integration-Valuation Framework and Incentive Gaps

Given these challenges and current modeling gaps on Long Duration Energy Storage (LDES), enhancing the structure and design of existing planning, operations, and organized wholesale markets can better characterize the value of LDES to the power system. To more thoroughly assess the gaps and barriers to LDES investment and readiness for integration into a future grid, we conducted stakeholder outreach through an online survey, interviews with individual independent system operators/regional transmission organizations, and a literature review. Based on this assessment, we identified a set of opportunities for LDES focused development, including a framework to quantify the contributions of LDES on resource adequacy, reliability, and resiliency. Specifically, we identify the potential demand for and benefits of an open-source, LDES-centric evaluation framework that can guide future planning, operations, market design, and policy reforms.

24 POWER TRANSMISSION AND DISTRIBUTION

AgRISTARS: Agriculture and resources inventory surveys through aerospace remote sensing

The major objectives and FY 1980 accomplishments are described of a long term program designed to determine the usefulness, cost, and extent to which aerospace remote sensing data can be integrated into existing or future USDA systems to improve the objectivity, reliability, timeliness, and adequacy of information. A general overview, the primary and participating agencies, and the technical highlights of each of the following projects are presented: early warning/crop condition assessment; foreign commodity production forecasting; yield model development; supporting research; soil moisture; domestic crops and land cover; renewable resources inventory; and conservation and pollution.

Source record

Impacts of Regional Coordination on Transmission Needs for Power System Resource Adequacy [Slides]

Resource adequacy (RA) is an important component of bulk power system reliability that addresses whether there are sufficient resources available to meet electricity demand at all times. RA analysis is used to assess whether the planned power system will provide reliable electricity to consumers while accounting for equipment outages, weather variability, and load uncertainty. Coordination between regions can enable resource sharing to meet RA needs if sufficient transmission capacity exists. Transmission's role in RA coordination can be particularly pronounced for large power systems like the U.S. electricity grid which contains geographically diverse demand and weather-dependent resources. Depending on the level of coordination desired, existing inter-regional transmission capacity may not be sufficient. This study is designed to assess optimal pathways for the development of inter-regional transmission in the U.S. under varying levels of RA coordination. Results can inform long-term grid infrastructure planning and provide insights into potential benefits of greater coordination for generation and transmission planning between regional U.S. power systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Energy Adequacy Studies: Nodal vs Zonal and Ramp-Rate Representation

This work investigates limitations in current energy adequacy studies, particularly concerning the representation of grid complexities. We highlight how traditional zonal modeling approaches, which simplify large geographic areas and generator capabilities, can mask critical transmission constraints and localized resource shortfalls. By analyzing nodal versus zonal pricing differences and the empirical distribution of generator ramp-rates, we demonstrate that these simplified assumptions may misrepresent system flexibility and deliverability. Our findings underscore the need for more granular, nodal-level analyses and data-driven characterizations of generation assets to provide a more accurate and robust assessment of energy reliability and adequacy, ultimately supporting a more resilient and efficient energy infrastructure.