Search NASA⌕ Search

SEARCH · Search NASA

Results for “ring corrections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral study of star-forming rings in S0 galaxies of Dorado group – NGC 1533 and NGC 1543

ABSTRACT We have fulfilled a detailed long-slit spectroscopic analysis for two SB0 galaxies – NGC 1533 and NGC 1543, – belonging to the Dorado group. Our spectral data reveal asymmetric decoupled kinematics of the stars and ionized gas in these barred lenticular galaxies that give evidences for external origin of the gas in the rings. We have calculated the star formation rates in the rings by using the ultraviolet fluxes of the rings corrected for the foreground and intrinsic absorption; and we have estimated parameters of the stellar populations in the inner parts of the galaxies confirming that they are old – except the nucleus of NGC 1543, which demonstrates signatures of rejuvenation less than 5 Gyr ago.

Proshina, Irina S.↗

Application of a Coincidence Ring Ratio Moderator Correction to the Assay of 235U Residues

Processing of irradiated UAl targets by NaOH dissolution for the extraction of 99Mo results in the creation of high-activity highly enriched uranium (HEU)–bearing residues that must be quantified. The HEU residues generated from this process are assayed using an Active Well Coincidence Counter (AWCC) that has been modified to accommodate >1 Sv/h gamma-ray exposure rates to provide a 235U mass value for each residues container. The HEU residues include a significant amount of residual moderator from the dissolution process. Fission product decay heat drives off much—but not all—of the hydrogen from the dissolution, leaving an unknown moderator content in the residues. The moderator content impacts the induced fission rate in the HEU, detection efficiency, and die-away time of the emitted neutrons and requires implementation of a moderator correction factor. Three moderator correction techniques have been implemented: an active coincidence ring ratio method, a conventional 252Cf Add-A-Source (AAS) measurement, and an AAS ring ratio measurement. The 252Cf AAS and the AAS ring ratio methods are potentially much faster, but they require additional sample handling and precise positioning of the residues container and the 252Cf source. This study was performed using a combination of Monte Carlo N-Particle (MCNP) [1] simulation and measurements. The impact of the moderator content on the AWCC measurement and the relative performance of the three moderator correction methods are presented.

Mcelroy Jr, Robert↗

Dynamic Aperture of JLEIC Electron Collider Ring with Errors and Correction

Design of the electron and ion rings of the Jefferson Lab Electron-Ion Collider (JLEIC) features the low-beta Interaction Regions (IR) with detector solenoid, non-linear chromaticity compensation blocks (CCB), and spin rotator optics with solenoids. The high beta functions in the IR final focus quadrupoles (FFQ) and in the CCB magnets result in strong effects of errors in these magnets. Performance of the spin rotators may also be sensitive to the errors. The first part of this study includes the design of orbit correction system for both rings and evaluation of dynamic aperture (DA) with misalignment and the correction. The second part is devoted to the DA study with the FFQ non-linear field errors. The orbit correction design, the dynamic aperture, and the impact on error specifications are presented.

Lin, F.↗

Direct focusing error correction with ring-wide TBT beam position data

Turn-By-Turn (TBT) betatron oscillation data is a very powerful tool in studying machine optics. Hundreds and thousands of turns of free oscillations are taken in just few tens of milliseconds. With beam covering all positions and angles at every location TBT data can be used to diagnose focusing errors almost instantly. This paper describes a new approach that observes focusing error collectively over all available TBT data to find the optimized quadrupole strength, one location at a time. Example will be shown and other issues will be discussed. The procedure presented clearly has helped to reduce overall deviations significantly, with relative ease. Sextupoles, being a permanent feature of the ring, will need to be incorporated into the model. While cumulative effect from all sextupoles around the ring may be negligible on turn-to-turn basis it is not so in this transfer line analysis. It should be noted that this procedure is not limited to looking for quadrupole errors. By modifying the target of minimization it could in principle be used to look for skew quadrupole errors and sextupole errors as well.

43 PARTICLE ACCELERATORS↗

Note on recent measurements of the {psi}(1S){yields}{gamma}{eta}{sub C}(1S) and {psi}(2S){yields}{gamma}{eta}{sub C}(1S) branching ratios

Recently published measurements of the branching ratios B({psi}(1S){yields}{gamma}{eta}{sub C}(1S)) and B({psi}(2S){yields}{gamma}{eta}{sub C}(1S)) by the CLEO Collaboration are examined in the context of a potential model that includes both relativistic and one-loop QCD corrections to the quark-antiquark interaction. The prediction for the width {gamma}({psi}(1S){yields}{gamma}{eta}{sub C}(1S)) is in excellent agreement with the new data, but the prediction for {gamma}({psi}(2S){yields}{gamma}{eta}{sub C}(1S)) is too small. In an effort to understand this discrepancy, we derive an upper bound on {gamma}({psi}(2S){yields}{gamma}{eta}{sub C}(1S)) and point out its experimental value saturates this bound.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Extended Group Additivity Method for Polycyclic Thermochemistry Estimation

Automatic kinetic mechanism generation, virtual high-throughput screening, and automatic transition state search are currently trending applications requiring exploration of a large molecule space. Large-scale search requires fast and accurate estimation of molecules’ properties of interest, such as thermochemistry. Existing approaches are not satisfactory for large polycyclic molecules: considering the number of molecules being screened, quantum chemistry (even cheap density functional theory methods) can be computationally expensive, and group additivity, though fast, is not sufficiently accurate. Here, this paper provides a fast and moderately accurate alternative by proposing a polycyclic thermochemistry estimation method that extends the group additivity method with two additional algorithms: similarity match and bicyclic decomposition. It significantly reduces H f (298 K) estimation error from over 60 kcal/mol (group additivity method) to around 5 kcal/mol, C p (298 K) error from 9 to 1 cal/mol/K,and S(298 K) error from 70 to 7 cal/mol/K. This method also works well for heteroatomic polycyclics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Are there four-dimensional small black rings?

In d>4 dimensions, one can argue for the existence of small black rings using a scaling argument. We apply the same scaling argument to the d=4 case and demonstrate that it fails to say anything about the existence of d=4 small black rings, because stringy corrections get out of control. General relativity theorems say that there does not exist a black hole with toroidal topology for d=4, but we interpret this as saying that, for d=4 small black rings, stringy corrections are crucial which invalidate the assumptions those theorems are based on.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reduction of ring artifacts in CBCT: Detection and correction of pixel gain variations in flat panel detectors

Purpose: In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accounted by conventional flat field correction methods. In this work, the authors presented a method to identify isolated pixel clusters that exhibit gain variations and proposed a pixel gain correction (PGC) method to suppress both beam hardening and exposure level dependent gain variations. Methods: To modulate both beam spectrum and entrance exposure, flood field FPD projections were acquired using beam filters with varying thicknesses. “Ideal” pixel values were estimated by performing polynomial fits in both raw and flat field corrected projections. Residuals were calculated by taking the difference between measured and ideal pixel values to identify clustered image and FPD artifacts in flat field corrected and raw images, respectively. To correct clustered image artifacts, the ratio of ideal to measured pixel values in filtered images were utilized as pixel-specific gain correction factors, referred as PGC method, and they were tabulated as a function of pixel value in a look-up table. Results: 0.035% of detector pixels lead to clustered image artifacts in flat field corrected projections, where 80% of these pixels were traced back and linked to artifacts in the FPD. The performance of PGC method was tested in variety of imaging conditions and phantoms. The PGC method reduced clustered image artifacts and fixed pattern noise in projections, and ring artifacts in CBCT images. Conclusions: Clustered projection image artifacts that lead to ring artifacts in CBCT can be better identified with our artifact detection approach. When compared to the conventional flat field correction method, the proposed PGC method enables characterization of nonlinear pixel gain variations as a function of change in x-ray spectrum and intensity. Hence, it can better suppress image artifacts due to beam hardening as well as artifacts that arise from detector entrance exposure variation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Error Correction for the JLEIC Ion Collider Ring

The sensitivity to misalignment, magnet strength error, and BPM noise is investigated in order to specify design tolerances for the ion collider ring of the Jefferson Lab Electron Ion Collider (JLEIC) project. Those errors, including horizontal, vertical, longitudinal displacement, roll error in transverse plane, strength error of main magnets (dipole, quadrupole, and sextupole), BPM noise, and strength jitter of correctors, cause closed orbit distortion, tune change, beta-beat, coupling, chromaticity problem, etc. These problems generally reduce the dynamic aperture at the Interaction Point (IP). According to real commissioning experiences in other machines, closed orbit correction, tune matching, beta-beat correction, decoupling, and chromaticity correction have been done in the study. Finally, we find that the dynamic aperture at the IP is restored. This paper describes that work.

Wei, Guohui↗