Pressure and apparent voidage profiles for riser with an abrupt exit (T-shape) in a CFB riser operating above fast fluidization regimes
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Tests were performed in a 0.1-m diameter small circulating fluidized bed (SCFB) and 0.3 m diameter cold flow circulating fluidized bed (CFCFB) riser systems located at the National Energy Technology Laboratory (NETL) to study the effects of riser diameter on the riser hydrodynamics. These tests were performed at solids circulation rates of G s = 20 and 75 kg/m 2 s and superficial gas velocities of U g = 5.8 and 6.5 m/s using high-density polyethylene (HDPE) pellets with a density of 0.863 g/cm 3 , particle size range of 600–1400 µm (with a Sauter mean diameter of 871 µm, placing them in the Geldart B classification). Comparisons of riser axial pressure and solids fraction profiles, radial particle velocity profiles, and radial profiles of higher statistical moments and select chaos analysis parameters were considered. The results showed that for a given U g and G s , the smaller diameter riser exhibited characteristics associated with more dilute solids flow than that observed in the larger diameter riser. Additionally, the larger diameter riser exhibited a downward flow of solids near the wall under all test conditions, whereas the smaller diameter riser data exhibited little or no indications of solids downflow near the wall. Overall, these findings suggest that, from an industrial standpoint, a direct scaleup of small-scale tests cannot readily be accomplished as the solids holdup and the solids velocity profiles in small units (those normally tested in the laboratory) are not similar to those of large units and the performance of large units can therefore not be predicted from small-scale tests.
Riser hydrodynamics are a function of the flow rates of gas and solids as well as the exit geometry, particularly when operated above the upper transport velocity. This work compares the exit voidage for multiple geometries and two different solids: Geldart group A glass beads and Geldart group B coke. Geometries were changed by modifying the volume of an abrupt T-shaped exit above the lateral riser exit. This was accomplished by positioning a plunger at various heights above the exit from zero to 0.38 m. A dimensionless expression used to predict smooth exit voidage was modified to account for the effect of the depth of the blind-T. The new correlation contains the solids-gas load ratio, solids-to-gas density ratio, bed-to-particle diameter ratio, gas Reynolds Number, as well as a term for the exit geometry. This study also found that there was a minimum riser roof height above the blind-T exit beyond which the riser exit voidage was not affected by the exit geometry. A correlation for this minimum riser roof height has also been developed in this study. This study covered riser superficial gas velocities of 4.35 to 7.7 m/s and solids circulation rates of 1.3 to 11.5 kg/s.
Presented by NETL at Fluidization XV, 05/16
A linear state model is proposed to analyze dynamic behavior of a circulating fluidized bed riser. Different operating regimes were attained with high density polyethylene beads at low and high system inventories. The riser was operated between the classical choking velocity and the upper transport velocity demarcating fast fluidized and transport regimes. At a given riser superficial gas velocity, the aerations fed at the standpipe were modulated resulting in a sinusoidal solids circulation rate that goes into the riser via L-valve. The state model was derived based on the mass balance equation in the riser. It treats the average solids fraction across the entire riser as a state variable. The total riser pressure drop was modeled using Newton’s second law of motion. The momentum balance equation involves contribution from the weight of solids and the wall friction caused by the solids to the riser pressure drop. The weight of solids utilizes the state variable and hence, the riser inventory could be easily calculated. The modeling problem boils down to estimating two parameters including solids friction coefficient and time constant of the riser. It has been shown that the wall friction force acts in the upward direction in fast fluidized regime which indicates that the solids were moving downwards on the average with respect to the riser wall. In transport regimes, the friction acts in the opposite direction. This behavior was quantified based on a sign of Fanning friction factor in the momentum balance equation. The time constant of the riser appears to be much higher in fast fluidized regime than in transport conditions.
This paper presents the tests and analytical approach used on the development of a steel riser cutter for the CEV Parachute Assembly System (CPAS) used on the Orion crew module. Figure 1 shows the riser cutter and the steel riser bundle which consists of six individual cables. Due to the highly compressed schedule, initial unavailability of the riser material and the Orion Forward Bay mechanical constraints, JSC primarily relied on a combination of internal ballistics analysis and LS-DYNA simulation for this project. Various one dimensional internal ballistics codes that use standard equation of state and conservation of energy have commonly used in the development of CAD devices for initial first order estimates and as an enhancement to the test program. While these codes are very accurate for propellant performance prediction, they usually lack a fully defined kinematic model for dynamic predictions. A simple piston device can easily and accurately be modeled using an equation of motion. However, the accuracy of analytical models is greatly reduced on more complicated devices with complex external loads, nonlinear trajectories or unique unlocking features. A 3D finite element model of CAD device with all critical features included can vastly improve the analytical ballistic predictions when it is used as a supplement to the ballistic code. During this project, LS-DYNA structural 3D model was used to predict the riser resisting load that was needed for the ballistic code. A Lagrangian model with eroding elements shown in Figure 2 was used for the blade, steel riser and the anvil. The riser material failure strain was fine tuned by matching the dent depth on the anvil with the actual test data. LS-DYNA model was also utilized to optimize the blade tip design for the most efficient cut. In parallel, the propellant type and the amount were determined by using CADPROG internal ballistics code. Initial test results showed a good match with LS-DYNA and CADPROG simulations. Final paper will present a detailed roadmap from initial ballistic modeling and LS-DYNA simulation to the performance testing. Blade shape optimization study will also be presented.
Steel cable was chosen for the lower end of the drogue and main parachute risers on NASA's Orion Multi Purpose Crew Vehicle Parachute Assembly System (CPAS) to protect the risers from extreme temperatures and abrasion should they contact the crew module during deployment, as was done for Apollo. Due to the weight and deployment complexity inherent in steel, there was significant interest in the possibility of substituting textile for steel for the drogue and main parachute risers. However, textile risers could be damaged when subjected to high temperature and abrasion. Investigations were consequently performed by a subset of the authors to determine whether sacrificial, non-load-bearing textile riser covers could be developed to mitigate the thermal and abrasion concerns. Multiple material combinations were tested, resulting in a cover design capable of protecting the riser against severe riser/crew module contact interactions. A feasibility study was then conducted to evaluate the performance of the textile drogue riser cover in relevant abrasive environments. This paper describes the testing performed and documents the results of this feasibility study.
Three-dimensional high-resolution numerical simulations of a gas–solid jet in a high-density riser flow were conducted. The impact of gas–solid injection on the riser flow hydrodynamics was investigated with respect to voidage, tracer mass fractions, and solids velocity distribution. The behaviors of a gas–solid jet in the riser crossflow were studied through the unsteady numerical simulations. Substantial separation of the jetting gas and solids in the riser crossflow was observed. Mixing of the injected gas and solids with the riser flow was investigated and backmixing of gas and solids was evaluated. In the current numerical study, both the overall hydrodynamics of riser flow and the characteristics of gas–solid jet were reasonably predicted compared with the experimental measurements made at NETL.
Very High Temperature gas-cooled Reactor (VHTR) that is one of GEN-IV reactors has been developed for the purpose of hydrogen production. VHTR is characterized by high operating temperature and stepped-up inherent safety given by passive safety systems such as Reactor Cavity Cooling System (RCCS). In case the active heat removal system losses its capability, RCCS significantly contributes to the inherent safety of VHTR by removing the decay heat transferred from the reactor core to the reactor vessel. Therefore, the performance of RCCS is the key parameter to ensure the safety of the reactor. Several computation and experiment researches on the performance of RCCS have been conducted. There are two types of RCCS depending on its coolant; one is the air-cooled type and the other is water-cooled type. This study focused on the former type. Due to the excessive height of the prototype RCCS, experiment facilities were constructed in reduced scale. Korea Atomic Energy Research Institute (KAERI) constructed the quarter-scale RCCS experiment facility, NACEF and Argonne National Laboratory (ANL) has constructed half-scale experiment facility, NSTF. University of Wisconsin (UW) also has the quarter-scale experiment facility and Texas A and M University has conducted separate effect test on the jet effect at the upper plenum of RCCS. From the reduced scale experiment result, the performance of RCCS such as a heat removal rate of RCCS and a peak temperature of reactor vessel were evaluated. When the reduced-scale result is applied to the prototype, however, a distortion could be brought about due to the reduced height of RCCS in the experiments. Especially, if the heat transfer regime inside the riser which roles as a heat exchanger to discharge the decay heat into the atmosphere is not identical, the riser wall temperature and the consequent reactor vessel temperature of the prototype could be incorrectly predicted. Thus, the convective heat transfer phenomena inside the riser duct both in the reduced scale and in the prototype is necessary to be investigated. In this study, the preliminary analysis on the heat transfer phenomena inside the RCCS riser was conducted. The subjects of the analysis were the prototype RCCS riser of PMR 200, and its scaled-down experiment facilities, NACEF. First, the geometry, flow and thermal conditions of the riser in PMR200 RCCS and NACEF were introduced with a scaling method. And then, the heat transfer regimes and the heat transfer coefficient corresponding to each condition were predicted using correlation and CFD calculation. Finally, planned activities including the experiment was introduced. (authors)
Any cluster of parachute systems is subject to effects on performance due to interactions between the parachutes. One such interaction is the twisting of a riser from one parachute around that of another. Due to friction and relative motion between the risers, it is possible for the tension in the riser near the attach point to be different from the tension in the riser towards the suspension lines or canopy. This could result in system failure due to larger than expected loading. The Orion Capsule Parachute Assembly System (CPAS) designed and executed a test to quantify the amplification of the load in a parachute riser due to twist, rocking rate and angle, cluster size, and canopy load. The design of the testing approach, test matrix, and hardware are discussed along with results and findings.
The solids flow in a circulating fluidized bed (CFB) riser is often described to have a core-annular structure. For a given superficial gas velocity, at the initial introduction of solids into a riser a flow structure of dilute upflow regime exists. Continuing to increase the solids flow in the riser transitions the flow structure to the core-annular flow regime. However, with further increase of solids flow a condition is reached, depending on the superficial gas velocity, where all the solids across the riser cross section flow upwards, even those at the wall. When the solids flux, solids fraction and gas velocity are relatively high, such a condition is described as the dense phase suspense upflow (DSU) regime. In this paper we report our observations of these flow regime transitions by using a laser Doppler velocimeter (LDV) to monitor the upward and downward particle flow velocities at and near the riser wall of the National Energy Technology Laboratory’s 30.4 centimeters diameter CFB cold flow model. The particles were high density polyethylene (PPE) spheres with a Sauter mean diameter of 861 micron and a density of 800 kg/m3. Three superficial gas velocities of 6.55 m/s, 10.67 m/s and 13.72 m/s were used in this study. For the case of superficial gas velocity 6.55 m/s, the experimental data show that the transition from dilute upflow to core-annular flow occurred when the solids flux was about 7 kg/m{sup 2}-s and the transition from core-annular flow to dense suspension upflow was about 147 kg/m{sup 2}-s. As the superficial gas velocity was increased to 10.67 m/s the corresponding flow regime transitions were at 34 kg/m{sup 2}-s and 205 kg/m{sup 2}-s, respectively. For the case of superficial gas velocity of 13.72 m/s the data showed no distinct transition of flow regimes. The particles were all upflow for the range of solids fluxes from 10 kg/m{sup 2}-s to 286 kg/m{sup 2}-s.
Dynamic analyses have been applied to the temporal signals from an Electro Capacitance Volume Tomography instrument located near mid-height on the riser of an industrial-scale cold-flow circulating fluidized bed to characterize gas-solids flow behavior in the riser. Twelve capacitance electrodes surround the cylindrical riser over a height of 1.3 m. The instrument used a neural network deconvolution algorithm to determine the spatially resolved solids fraction recorded at 52 Hz. Experiments were carried out over a range of gas and solids flows in the transport regime using a Geldart Group B bed material, high density polyethylene with mean particle size of 880 μm. The radial solids distribution was found to vary from one-time step to the next between profiles typical of laminar and turbulent flow. The duration of time spent in each of these flow profiles depended upon the operating regime – dilute, core-annular, or fast fluidized bed. The chaotic structure of the temporal data was characterized using the three conventional approaches: the first 4 moments from the distribution of signal in time, system memory parameters from the autocorrelation function and the Hurst exponent, and analysis of the correlationentropy and correlation dimension of the attractor. These signal analysis techniques were used to clearly distinguish differences between different transport operating regimes. Specifically, it was experimentally observed that a riser transitions from core annular flow profile to dilute and dense regimes via increasing the frequency of short term transients to either dilute or dense flow profiles, respectively. A regime map was generated based upon these dynamics using solids flux and gas velocity axes. Fast fluidized, core annular, and dilute each exhibited different degree of dynamic characteristics typical of fluid dominated or particle compromising behavior. It should be noted that the magnitude for the different statistics was in the same range regardless of the regime, it was the radial profile for the statistic that changed and subsequently identified that there was a change in the regime. Finally, a reduced regime map was developed consisting of plotting the gas velocity normalized by the upper transport velocity versus the solids flux normalized by the saturation carrying capacity. The use of this reduced plot allowed the data from widely different conditions to be plotted and compared on the same<p>graph. Note that in many instances, some of the statistics identified the operating point as being in one regime while others indicated that it was in another indicating a transition region between dilute or core annular regimes and between the core annular and fast fluidization regimes. This now provides a tool that can be used to optimize process performance, identify changes in operating states, or replicate process dynamics during process scaling or changing operating parameters. </p>
Nuclear decommissioning is constrained and defined by radiation and radioactive contamination. Where radiation is high and its distribution is unknown simply gathering the data needed for project planning can become a challenge. Fukushima Daiichi epitomises this challenge. The complex sequence of events at the plant following the March 2011 earthquake and tsunami has resulted in extensive physical damage and an essentially unpredictable distribution of contamination. TEPCO have applied a range of manual and robotics techniques to map the status of the plant, but many significant areas have remained no-go zones due to a combination of high radiation, physical hazards and obstacles. Further, even in areas where manual survey is feasible, there is strong desire to minimise human exposure to radiation by deploying robots where possible. Riser is a fully autonomous UAV equipped with an infrastructure-free 3D navigation and mapping system, inspection cameras and a CZT spectrometric measurement capability. The system has been custom designed specifically to meet the needs of the nuclear inspection. Riser is capable of accessing areas with dose rates of hundreds of milli-sievert per hour and producing 3D models and radiation surveys with accurately located data points. The data from Riser can subsequently be fused using Createc's N-Visage engine to produce three-dimensional contamination maps which can be used for predictive modelling of future D and D activity. Riser has been deployed at Fukushima Daiichi since March 2017. We present examples of data and analysis outputs, as well as general learning about deploying autonomous robots at a nuclear site. (authors)
Circulating fluidized bed riser reactors have been a commercial reality for some 80 to 90 years. Through all this time and hundreds if not thousands of research papers on the topic, no clear understanding exists on what is required to design and build a process reactor. There are numerous reasons for this, but the most significant reason is likely that riser reactors are chaotic in nature and unless this chaotic behavior is accounted for, there will be wide discrepancies in the predicted performance and in attempts to scale these reactors without significant trial and error. This work puts forth a new methodology to design riser reactors based upon the desired operating range using the chaotic microstructure behavior. This is accomplished through the use of a nondimensional regime map that was developed using chaotic parameters of memory and order/disorder along with higher moments of skewness and kurtosis. Validation of the approach is provided with circulating fluidized bed combustors and applied to the design of the NETL ASURE facility.
Here we develop a fast multi-fidelity modeling method for very complex correlations between high- and low-fidelity data by working in modal space to extract the proper correlation function. We apply this method to infer the amplitude of motion of a flexible marine riser in cross-flow, subject to vortex-induced vibrations (VIV). VIV are driven by an absolute instability in the flow, which imposes a frequency (Strouhal) law that requires a matching with the impedance of the structure; this matching is easily achieved because of the rapid parametric variation of the added mass force. As a result, the wavenumber of the riser spatial response is within narrow bands of uncertainty. Hence, an error in wavenumber prediction can cause significant phase-related errors in the shape of the amplitude of response along the riser, rendering correlation between low- and high-fidelity data very complex. Working in modal space as outlined herein, dense data from low-fidelity data, provided by the semi-empirical computer code VIVA, can correlate in modal space with few high-fidelity data, obtained from experiments or fully-resolved CFD simulations, to correct both phase and amplitude and provide predictions that agree very well overall with the correct shape of the amplitude response. We also quantify the uncertainty in the prediction using Bayesian modeling and exploit this uncertainty to formulate an active learning strategy for the best possible location of the sensors providing the high fidelity measurements.
This experimental plan defines crystal settling experiments to be in support of the U.S. Department of Energy – Office of River Protection crystal tolerant glass program. The road map for development of crystal-tolerant high level waste glasses recommends that fluid dynamic modeling be used to better understand the accumulation of crystals in the melter riser and mechanisms of removal. A full-scale version of the Hanford Waste Treatment and Immobilization Plant (WTP) melter riser constructed with transparent material will be used to provide data in support of model development. The system will also provide a platform to demonstrate mitigation or recovery strategies in off-normal events where crystal accumulation impedes melter operation. Test conditions and material properties will be chosen to provide results over a variety of parameters, which can be used to guide validation experiments with the Research Scale Melter at the Pacific Northwest National Laboratory, and that will ultimately lead to the development of a process control strategy for the full scale WTP melter. The experiments described in this plan are divided into two phases. Bench scale tests will be used in Phase 1 (using the appropriate solid and fluid simulants to represent molten glass and spinel crystals) to verify the detection methods and analytical measurements prior to their use in a larger scale system. In Phase 2, a full scale, room temperature mockup of the WTP melter riser will be fabricated. The mockup will provide dynamic measurements of flow conditions, including resistance to pouring, as well as allow visual observation of crystal accumulation behavior.
MP-PIC (multi-phase particle in cell) method combined with the EMMS (energy minimization multi- scale) drag force model was implemented with the open source program MFIX to simulate the gas–solid flows in CFB (circulatingfluidizedbed) risers. Calculated solid flux by the EMMS drag agrees well with the experimental value; while the traditional homogeneous drag over-predicts this value. EMMS drag force model can also predict the macro-and meso-scale structures. Quantitative comparison of the results by the EMMS drag force model and the experimental measurements show high accuracy of the model. The effects of the number of particles per parcel and wall conditions on the simulation results have also been investigated in the paper. This work proved that MP-PIC combined with the EMMS drag model can successfully simulate the fluidized flows in CFB risers and it serves as a candidate to realize real-time simulation of industrial processes in the future.