Search NASA⌕ Search

SEARCH · Search NASA

Results for “rooftop solar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Photovoltaic solar array technology required for three wide scale generating systems for terrestrial applications: rooftop, solar farm, and satellite

Three major options for wide-scale generation of photovoltaic energy for terrestrial use are considered: (1) rooftop array, (2) solar farm, and (3) satellite station. The rooftop array would use solar cell arrays on the roofs of residential or commercial buildings; the solar farm would consist of large ground-based arrays, probably in arid areas with high insolation; and the satellite station would consist of an orbiting solar array, many square kilometers in area. The technology advancement requirements necessary for each option are discussed, including cost reduction of solar cells and arrays, weight reduction, resistance to environmental factors, reliability, and fabrication capability, including the availability of raw materials. The majority of the technology advancement requirements are applicable to all three options, making possible a flexible basic approach regardless of the options that may eventually be chosen. No conclusions are drawn as to which option is most advantageous, since the feasibility of each option depends on the success achieved in the technology advancement requirements specified.

Berman, P. A.↗

Satellite Beach Energy - Restructuring the Energy Balance in Satellite Beach, Florida, by Quantifying Solar Energy Production Potential using NASA POWER Data Products and LiDAR

The City of Satellite Beach, Florida, has committed to supplying 100% of its energy use from renewable energy, primarily solar, by the year 2050. The team created a methodology for estimating rooftop solar power potential using a high-resolution Light Detection and Ranging (LiDAR) dataset and the NASA Prediction of Worldwide Energy Resources (POWER) dataset to assist Satellite Beach in reaching their solar renewable energy goals. The POWER dataset provides information on direct and diffuse solar irradiation on horizontal surfaces, surface albedo, and effects of local meteorology, such as clouds. The team integrated the solar irradiance data with the LiDAR data to model slope, aspect, and shadowing in the 7 km2 study area to find suitable roof segments for solar panel installation and estimate the solar potential of each segment. This process was supplemented by an analysis of land surface temperature and urban greenness measured through the Normalized Difference Vegetation Index (NDVI) from Landsat 8 Operational Land Imager and Thermal Infrared Sensor (OLI/TIRS) observations. These metrics serve to target areas for cooling initiatives aimed at reducing Satellite Beach’s overall energy consumption. The team found the total rooftop solar potential throughout the city to be 221,919,330KWh per year with an average annual rooftop photovoltaic, or PV, potential of 55,647KWh per building. As such, the average building could generate over five times the annual energy needs for an average household if PV panels were installed on all viable areas of its roof.

Spencer Nelson↗

Washington, D.C. & Maryland Energy: Estimating Solar Potential Using NASA POWER Data to Inform Renewable Energy Policy for Washington, D.C.

In line with the Sustainable D.C. 2.0 plan to combat climate change, Washington D.C. aims to decrease its greenhouse gas emissions by 100% by 2050. As solar energy is a clean, renewable energy form, its integration into the region’s power grids lowers energy costs and incentivizes sustainable development. We partnered with the Washington D.C. Department of Energy & Environment (DOEE) to determine how urban areas surrounding D.C. can better be incorporated into decisions regarding renewable energy policy. The team used NASA’s Prediction of Worldwide Energy Resources (POWER) solar data and a Light Detection and Ranging (LiDAR) derived digital surface model, to estimate and visualize rooftop solar potential for Maryland’s Prince George’s and Montgomery counties. POWER provided solar irradiance data adjusted for tilt angle while the digital surface model contributed aspect and slope data. This methodology factored out areas that were unsuitable for solar panel installation while displaying areas that possess a high potential for energy return. The team found the total rooftop solar potential for the study area to be almost 32 million kW, which is equivalent to roughly 660 kW per building. The methodology used to generate the solar potential maps can be applied to other regions of the country seeking to efficiently utilize solar energy. The end users at the DOEE can use our resulting solar potential map and data table to effectively target buildings that have the highest potential to generate solar energy.

Edward Cronin↗

Edge Supports for Photovoltaic Modules

Mounting strips patterned after glazing gaskets. Easy to install supports for rooftop solar modules consist of extruded rubber mullions with locking zippers. Supports cut to length with utility knife and installed without special tools. Adaptable to many different roof configurations.

Maloney, T. J.↗

Solar house system interfaced with the power utility grid

Photovoltaic cells may be used to convert sunlight directly into electrical energy and into low-grade heat to be used for large scale terrestrial solar energy conversion. Both forms of energy can be utilized if such cells are deployed in close proximity to the consumer (rooftop). CdS/Cu2S solar cells are an example of cells which may be produced inexpensively enough to become economically attractive. Cell parameters relevant for combined solar conversion are presented. Critical issues, such as production yield, life expectancy, stability of performance, are discussed. Systems design parameters related to operating temperatures are analyzed. First results obtained on Solar One, the experimental solar house of the University of Delaware, are given. Economic aspects are discussed.

Boeer, K. W.↗

Cambridge Urban Development - Quantifying Changes in Urban Albedo with NASA Earth Observations to Reduce Urban Heat Island Effect in Cambridge, Massachusetts

The urban heat island (UHI) effect occurs when urban areas have temperatures that are warmer on average than the surrounding suburban and rural regions. Low albedo surfaces traditionally found in urban landscapes, such as dark asphalt and rooftops, absorb solar irradiance and reemit heat, which contributes to the UHI effect. Cambridge,Massachusetts,part of the Boston metropolitan area,expects severe impacts on human health,infrastructure, and local environmental features due to increasing urban heat. The Massachusetts – Boston NASA DEVELOP team partnered with the City of Cambridge Community Development Department and the American Geophysical Union’s Thriving Earth Exchange to inform ongoing planning and heat mitigation efforts. High Resolution Orthoimagery (HRO) and National Agriculture Imagery Program (NAIP) scenes were analyzed in conjunction with ancillary datasets to assess changes in rooftop albedo between 2008 and 2018. Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data were used to determine nighttime land surface temperature (LST) between 2003 and 2019. Lastly, temperature anomalies were calculated using seasonally averaged nighttime LST values obtained from Aqua MODIS to display ‘hot spots’ for summers between 2004 and 2019. On average, albedo increased by 0.12 across the city, with the majority of positive change in commercial areas. Analysis of mean summer nighttime LST between 2003 and 2019 revealed a non-significant increase in temperature, although temperature anomaly maps demonstrated that Cambridge was warmer on average than rural areas. These results were incorporated in the interactive Cambridge Urban Heat Dashboard, which allows users to explore temporal trends in albedo.

Nicole Ramberg-Pihl↗

Cambridge Urban Development: Quantifying Changes in Urban Albedo with NASA Earth Observations to Reduce Urban Heat Island Effect in Cambridge, Massachusetts

The urban heat island (UHI) effect occurs when urban areas have temperatures that are warmer on average than the surrounding suburban and rural regions. Low albedo surfaces traditionally found in urban landscapes, such as dark asphalt and rooftops, absorb solar irradiance and reemit heat, which contributes to the UHI effect. Cambridge, Massachusetts, part of the Boston metropolitan area, expects severe impacts on human health, infrastructure, and local environmental features due to increasing urban heat. The Massachusetts – Boston NASA DEVELOP team partnered with the City of Cambridge Community Development Department and the American Geophysical Union’s Thriving Earth Exchange to inform ongoing planning and heat mitigation efforts. High Resolution Orthoimagery (HRO) and National Agriculture Imagery Program (NAIP) scenes were analyzed in conjunction with ancillary datasets to assess changes in rooftop albedo between 2008 and 2018. Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data were used to determine nighttime land surface temperature (LST) between 2003 and 2019. Lastly, temperature anomalies were calculated using seasonally averaged nighttime LST values obtained from Aqua MODIS to display ‘hot spots’ for summers between 2004 and 2019. On average, albedo increased by 0.12 across the city, with the majority of positive change in commercial areas. Analysis of mean summer nighttime LST between 2003 and 2019 revealed a non-significant increase in temperature, although temperature anomaly maps demonstrated that Cambridge was warmer on average than rural areas. These results were incorporated in the interactive Cambridge Urban Heat Dashboard, which allows users to explore temporal trends in albedo.

Nicole Ramberg-Pihl↗

Integrating Residential Photovoltaics With Power Lines

Report finds rooftop solar-cell arrays feed excess power to electric-utility grid for fee are potentially attractive large-scale application of photovoltaic technology. Presents assessment of breakeven costs of these arrays under variety of technological and economic assumptions.

Borden, C. S.↗

Utilization of space technology for terrestrial solar power applications

A description is given of the evolution of photovoltaic power systems designed and built for terrestrial applications, giving attention to problem areas which are currently impeding the further development of such systems. The rooftop testing of surplus solar panels is considered along with solar powered seismic observatories, solar powered portable radio sets, and design considerations identified from past experience. Present activities discussed are related to a solar powered on-shore beacon flasher system, a solar powered buoy, and a solar powered beacon flasher buoy.

Yasui, R. K.↗

High Spatial Resolution Airborne Multispectral Thermal Infrared Remote Sensing Data for Analysis of Urban Landscape Characteristics

We have used airborne multispectral thermal infrared (TIR) remote sensing data collected at a high spatial resolution (i.e., 10m) over several cities in the United States to study thermal energy characteristics of the urban landscape. These TIR data provide a unique opportunity to quantify thermal responses from discrete surfaces typical of the urban landscape and to identify both the spatial arrangement and patterns of thermal processes across the city. The information obtained from these data is critical to understanding how urban surfaces drive or force development of the Urban Heat Island (UHI) effect, which exists as a dome of elevated air temperatures that presides over cities in contrast to surrounding non-urbanized areas. The UHI is most pronounced in the summertime where urban surfaces, such as rooftops and pavement, store solar radiation throughout the day, and release this stored energy slowly after sunset creating air temperatures over the city that are in excess of 2-4'C warmer in contrast with non-urban or rural air temperatures. The UHI can also exist as a daytime phenomenon with surface temperatures in downtown areas of cities exceeding 38'C. The implications of the UHI are significant, particularly as an additive source of thermal energy input that exacerbates the overall production of ground level ozone over cities. We have used the Airborne Thermal and Land Applications Sensor (ATLAS), flown onboard a Lear 23 jet aircraft from the NASA Stennis Space Center, to acquire high spatial resolution multispectral TIR data (i.e., 6 bandwidths between 8.2-12.2 (um) over Huntsville, Alabama, Atlanta, Georgia, Baton Rouge, Louisiana, Salt Lake City, Utah, and Sacramento, California. These TIR data have been used to produce maps and other products, showing the spatial distribution of heating and cooling patterns over these cities to better understand how the morphology of the urban landscape affects development of the UHI. In turn, these data have been used by government officials, urban planners, and other decision-makers, to make more informed decisions on how to mitigate the UHI and its subsequent impacts.

Quattrochi, Dale A.↗

Urban solar photovoltaics potential: An inventory and modelling study applied to the San Fernando Valley region of Los Angeles

Procedures for analyzing the potential of solar photovoltaic collectors to meet energy requirements in a metropolitan region are described and a modeling effort is applied to the San Fernando Valley region of Los Angeles. The procedure involves a series of steps designed to produce maps and tabulations revealing the amount of rooftop area available for establishing solar collectors and the proportion of energy requirement that could be potentially supplied by solar photovoltaics within each of the 533 mainline feeder service areas in the study area. For the sixty five square mile study area, the results showed that, with half the available flat and south facing roofs used and assuming the availability of energy storage, 52.7 percent of the actual kWh energy requirements could have been met in 1978 using photovoltaic collectors. Hourly, daily, weekly, and monthly fluctuations in potential supply and actual loads and recommendations of avenues for further research are discussed. Some further potential applications of the modeling technique are suggested.

Angelici, G. L.↗

Solar electric and thermal conversion system in close proximity to the consumer

Solar cells may be used to convert sunlight directly into electrical energy and into lowgrade heat to be used for large-scale terrestrial solar-energy conversion. Both forms of energy can be utilized if such cells are deployed in close proximity to the consumer (rooftop). Cadmium-sulfide/copper-sulfide (CdS/Cu2S) solar cells are an example of cells which may be produced inexpensively enough to become economically attractive. Cell parameters relevant for combined solar conversion are presented. Critical issues, such as production yield, life expectancy, and stability of performance, are discussed. Systems-design parameters related to operating temperatures are analyzed. First results obtained on Solar One, the experimental house of the University of Delaware, are given. Economic aspects are discussed. Different modes of operation are discussed in respect to the power utility and consumer incentives.

Boeer, K. W.↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

A New Look For Greenbelt

Greenbelt, Maryland, 12 miles from the nation's capital, is an efficiently planned model town and most of its 1600 homes are almost identical in appearance. Four of them, however, stand out from their neighbors; they have distinctive blue glass rooftop superstructures made up of a series of solar collectors. They are part of a NASA community aid program, a joint energy research project involving the Greenbelt housing cooperative and NASA's Goddard Space Flight Center, located near the community. Built in 1935, Greenbelt is one of three government-planned communities of President Franklin D. Roosevelt's first administration; the others are Greendale, Wisconsin and Greenhills, Ohio. The government built the towns to make available low-cost housing, provide employment for workers on relief in the Great Depression era, and to establish models designed to encourage construction of similar developments by private industry. In 1952, the residents of Greenbelt formed a nonprofit cooperative called Greenbelt Homes, Inc., which bought the dwellings, facilities and a large part of the land from the government. The homes are individually owned but collectively maintained by the co-op, with each owner paying a prorated share of utility and maintenance costs. Greenbelt residents are mostly in the low and medium income brackets, and one of every three families lives on a fixed retirement income. For that reason, the sharp escalation of fuel oil prices that began in 1973 imposed particular hardship on the co-op community. So Greenbelt Homes' management asked its NASA neighbor, Goddard Space Flight Center, for assistance in setting up a solar energy research project. The idea was to conduct a small scale demonstration to show what savings could be realized by solar heating Greenbelt homes, with an eye toward possible future expansion of solar energy systems as a means of combating rising fuel costs. Goddard undertook the project as part of the federal government's effort to research and demonstrate ways of conserving energy. The Center was well qualified for the assignment, having acquired extensive expertise in designing thermal control systems for satellites, which must maintain stable temperatures for successful operation.

Source record↗

Solar potential inventory and modeling

Image processing procedures for calculating the energy that roof-mounted solar collectors can potentially supply in a metropolitan area are presented. Satellite multispectral imagery from which land cover types can be determined digitally was sampled in order to estimate the percentage of land area occupied by flat or south-facing roof tops in residential and commercial/industrial areas. Procedures were applied to the various power subdistricts of the western San Fernando valley of California, and it was found that on the average 120% of the existing power demand could be met if only half the useable rooftop area were utilized, amounting to 385 MW of peak power and indicating the applicability of solar cells to power generation in urban areas.

Angelici, G. L.↗

Photovoltaic Roofs

Solar cells perform two functions: waterproofing roof and generating electricity. Sections through horizontal and slanting joints show overlapping modules sealed by L-section rubber strips and side-by-side modules sealed by P-section strips. Water seeping through seals of slanting joints drains along channels. Rooftop photovoltaic array used watertight south facing roof, replacing shingles, tar, and gravel. Concept reduces cost of residential solar-cell array.

Drummond, R. W., Jr.↗

Portable linear-focused solar thermal energy collecting system

A solar heat collection system is provided by utilizing a line-focusing device that is effectively a cylindrically curved concentrator within a protected environment formed by a transparent inflatable casing. A target, such as a fluid or gas carrying conduit is positioned within or near the casing containing the concentrator, at the line focus of the concentrator. The casing can be inflated at the site of use by a low pressure air supply to form a unitary light weight structure. The collector, including casing, concentrator and target, is readily transportable and can be used either at ground level or on rooftops. The inflatable concentrator can be replaced with a rigid metal or other concentrator while maintaining the novel advantages of the whole solar heat collection system.

Miller, C. G.↗

Uses of infrared thermography in the low-cost solar array program

The Jet Propulsion Laboratory has used infrared thermography extensively in the Low-Cost Solar Array (LSA) photovoltaics program. A two-dimensional scanning infrared radiometer has been used to make field inspections of large free-standing photovoltaic arrays and smaller demonstration sites consisting of integrally mounted rooftop systems. These field inspections have proven especially valuable in the research and early development phases of the program, since certain types of module design flaws and environmental degradation manifest themselves in unique thermal patterns. The infrared camera was also used extensively in a series of laboratory tests on photovoltaic cells to obtain peak cell temperatures and thermal patterns during off-design operating conditions. The infrared field inspections and the laboratory experiments are discussed, and sample results are presented.

Glazer, S. D.↗