Search NASA⌕ Search

SEARCH · Search NASA

Results for “rotated control frames”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Novel Rotated Virtual Synchronous Generator Control for Power-Sharing in Microgrids with Complex Line Impedance

Virtual synchronous generator (VSG) control is based on the fact that the line impedance in a microgrid is highly inductive. This assumption was made due to the emulation of the stator winding of an electrical machine. This concept can affect the controllability of a microgrid with complex line impedance, generating deviations in the chosen operation point. To overcome this issue, additional techniques must be implemented. This paper describes a novel mathematical approach that uses the power line characteristics in a microgrid to rotate the power control reference frame and proposes a new control method called a “Rotated Virtual Synchronous Generator” (RVSG). This RVSG control approach integrates the effect of complex impedance on the microgrid’s operation and adjusts the reference frame accordingly to improve the system’s stability and performance. The use of this proposed mathematical approach in microgrids allows the further emulation of virtual inertia in microgrids that lack inertia. Finally, a comparison between RVSG control and the classical virtual synchronous generator method is carried out to show that it allows the improvement of the transient power response, power quality, stability, and performance, mainly in microgrids with complex line impedance.

42 ENGINEERING↗

Design and Analysis of an Integral MPPT Control Law for Wave Energy Conversion Systems

In this paper, we propose an integral-based maximum power point tracking (MPPT) algorithm for point absorber wave energy conversion (WEC) systems. A permanent magnet synchronous generator (PMSG) is coupled to the point absorber and its drive implements the proposed MPPT control. While the rotating frame of reference of the PMSG implements power control, the slower mechanical frequency of the incident waves are processed with an additional transformation that yields another set of dc dynamics. The computed dc power in the new reference frame, which is focused on slow wave dynamics, is input to the MPPT control law that tunes the emulated resistance of the machine drive to extract peak power from the wave absorber device. We derive a stability condition for the proposed controller and validate our control design on a simulated 10kW system.

wave energy, maximum power point tracking (MPPT), ↗

A Novel Grid-forming Voltage Control Strategy for Supplying Unbalanced Microgrid Loads Using Inverter-based Resources

This paper presents a novel grid-forming voltage control strategy for a battery energy storage system to maintain balanced three-phase output voltages when serving unbalanced loads. A stationary reference frame (αβ) based control scheme is proposed to regulate positive-sequence and negative-sequence voltages. Compared with the conventional rotating reference frame (dq) based control scheme, the proposed scheme shows better dynamic performance. Then, we analyze the system zero-sequence network and propose adding a grounding transformer to the Y/Yg connected output transformer to further reduce the voltage unbalance at the point of common coupling. The simulation results demonstrate the effective performance of the proposed voltage control scheme. Based on the results, the power-voltage unbalance curve is derived for different output transformer configurations to establish the relationship between the power unbalance limit and the voltage unbalance limit for microgrid power scheduling.

Xu, Bei↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

Rotated-Droop Control for Enhanced Stability and Power Decoupling in Microgrids With Complex Line Impedances

Classical droop control in microgrids predominantly assumes inductive line impedance, which simplifies implementation but causes power coupling and steady-state errors in systems with resistive and inductive lines. This paper proposes a rotated-droop control strategy for grid-forming inverters that reformulates the power equations by incorporating the magnitude and angle of the line impedance within a rotated reference frame. This method enhances the decoupling of active and reactive power dynamics without increasing complexity or requiring communication links. A small-signal state-space model was created to capture the dynamic behavior of the system under varying impedance parameters, preserving the original droop gains by rotating the power control structure. This allows eigenvalue-based stability analysis and enhances damping and transient performance. Simulation and experimental results validated the improved power-sharing performance, faster response, and robustness of the proposed method under different impedance conditions. This approach maintains the decentralized structure of the conventional droop control while enabling greater adaptability and scalability, making it suitable for modern inverter-based microgrids with dynamic topologies.

Campo-Ossa, Daniel Dario [Univ. of Puerto Rico, Ag↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Active tether control for a tethered multirotor

A control system and method for tensioning an active tether for a multirotor unmanned aerial system is provided. The control system includes a tensioning pulley and a tensioning spring. The tensioning spring is arranged to generate a variable tension force on the active tether. A transducer is connected adjacent to the tensioning spring to sense a linear displacement position of the tensioning pulley and to transmit a position signal to a controller. The position signal is proportional to the linear displacement position. A servomotor in communication with the controller receives a control signal from the controller in response to the position signal. The servomotor drives a cable reel. The cable reel is rotatably mounted in the frame for spooling the tether in response to rotation of the servomotor. The cable reel is rotated by the servomotor to maintain a predetermined tension on the tensioning spring.

Callow, Diane Schafer↗

An Optimized Parameterization of Sub‐Grid Scale Advection for Convection Permitting Models

Convection‐permitting models (CPMs) explicitly resolve deep convection yet under‐resolve the organized lateral exchanges among drafts and their environment that control entrainment/detrainment, precipitation efficiency, and mesoscale structure. In this work, we introduce the Optimized Advection Scheme (OAS), which introduces a small rotation of the Cartesian frame of reference for the horizontal winds relative to other variables used in advection that induces cross‐gradient transport to mimic under‐resolved convective mixing. The rotation angle is selected to minimize the Kullback–Leibler divergence between the simulated and satellite observed precipitation intensity distributions, yielding a physically consistent perturbation that is computationally inexpensive and portable. Optimized Advection Scheme is implemented in WRF and evaluated over Amazon (April 2014). It shifts precipitation–precipitable‐water joint distributions toward lighter rain, reduces overly intense rates, and improves mesoscale convective system (MCS) lifetime and propagation. Mechanistically, the added cross‐gradient transport promotes convective detrainment and environmental mixing, which cools and moistens the mid‐troposphere, weakens downward momentum transport, alleviates excessive downwelling shortwave biases, and warms the surface temperature. The optimized rotation angle yields comparable improvements at 4‐km and 1‐km grid spacing, demonstrating resolution‐independent benefits across the CPM gray zone. By targeting the dynamical root of under‐mixed convective circulations, rather than tuning model microphysics or closures, OAS delivers robust, scale‐aware improvements in precipitation statistics, cloud vertical structure, and characteristics of MCS (MCSs), offering a practical pathway to more reliable CPM simulations for weather and climate applications.

CPM↗

Semi-inclusive deep-inelastic scattering on a polarized spin-1 target. II. Deuteron and spectator nucleon tagging

We develop the theoretical framework for semi-inclusive deep-inelastic scattering on a polarized spin-1 target and apply it to scattering on the polarized deuteron with spectator nucleon tagging. In Part I (previous article), we present the general form of the semi-inclusive cross section and polarization observables for the spin-1 target. In Part II (this article), we consider deep-inelastic scattering on the polarized deuteron with spectator nucleon tagging as a special case of target fragmentation. Methods of light-front quantization are employed to separate nuclear and hadronic structure in the high-energy process and achieve a composite description. The light-front wave function of the polarized deuteron is obtained from a rotationally covariant three-dimensional wave function in the center-of-mass frame of the proton-neutron system. The tagged structure functions are computed in the impulse approximation. The momentum and spin distribution of the active nucleon are controlled by the deuteron polarization and the detected spectator momentum (𝐷/𝑆 wave ratio). The cross section and spin asymmetries are evaluated for general deuteron polarization (vector and tensor, longitudinal and transverse) as functions of the spectator momentum. Tensor-polarized spin asymmetries of order unity are achieved for spectator momenta of approximately 300 MeV, which select configurations with a large 𝐷 wave. Sum rules for the tagged spin structure functions are derived. The results can be used for simulations of spectator tagging in future polarized fixed-target experiments (Jefferson Lab) or at the Electron-Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Attosecond control and measurement of chiral photoionization dynamics

Many chirality-sensitive light–matter interactions are governed by chiral electron dynamics. Therefore, the development of advanced technologies making use of chiral phenomena would critically benefit from measuring and controlling chiral electron dynamics on their natural attosecond timescales. Such endeavours have so far been hampered by the lack of characterized circularly polarized attosecond pulses, an obstacle that has recently been overcome. Here we introduce chiroptical spectroscopy with attosecond pulses and demonstrate attosecond coherent control over photoelectron circular dichroism (PECD), as well as the measurement of chiral asymmetries in the forward–backward and angle-resolved photoionization delays of chiral molecules. We show that co-rotating attosecond and near-infrared (IR) pulses can nearly double the PECD and even change its sign compared with single-photon ionization. We demonstrate that chiral photoionization delays depend on both polar and azimuthal angles of photoemission in the light-propagation frame, requiring 3D momentum resolution. We measure forward–backward chiral-sensitive delays of up to 60 as and polar-angle-resolved photoionization delays of up to 240 as, which include an asymmetry of about 60 as originating from chirality in the continuum–continuum transitions. Attosecond chiroptical spectroscopy opens the door to quantitatively understanding and controlling the dynamics of chiral molecules on the electronic timescale.

Atomic and molecular interactions with photons↗

Simulation of CEFR neutronic start-up tests with FENNECS

This paper presents simulation results of selected Neutronic Start-up Tests of the China Experimental Fast Reactor (CEFR) obtained by the neutronics code FENNECS that have been performed within the frame of the IAEA Coordinated Research Program I31032. The Finite Element Neutronics code FENNECS is developed at GRS and solves the few-group steady-state and transient diffusion equation using a Galerkin-based finite element approach. Its main purpose is the safety assessment of Small Modular Reactors and Micro Reactors with complex geometry (e.g., rotating control drums) which gain increased interest internationally. Serpent has been applied to create reference models of the CEFR and cross-section libraries in 10 energy groups for FENNECS. Using these libraries, the following experiments have been simulated with FENNECS: net criticality, control rod integral and differential worth, void reactivity effect, subassembly exchange reactivity effects and reaction rate distribution. The obtained satisfactory agreements with the measurements represent a valuable contribution to the validation of FENNECS. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ultrafast Molecular Frame Quantum Tomography

Here, we develop and experimentally demonstrate a methodology for a full molecular frame quantum tomography (MFQT) of dynamical polyatomic systems. We exemplify this approach through the complete characterization of an electronically nonadiabatic wave packet in ammonia (NH 3 ). The method exploits both energy and time-domain spectroscopic data, and yields the lab frame density matrix (LFDM) for the system, the elements of which are populations and coherences. The LFDM fully characterizes electronic and nuclear dynamics in the molecular frame, yielding the time- and orientation-angle dependent expectation values of any relevant operator. For example, the time-dependent molecular frame electronic probability density may be constructed, yielding information on electronic dynamics in the molecular frame. In NH 3 , we observe that electronic coherences are induced by nuclear dynamics which nonadiabatically drive electronic motions (charge migration) in the molecular frame. Here, the nuclear dynamics are rotational and it is nonadiabatic Coriolis coupling which drives the coherences. Interestingly, the nuclear-driven electronic coherence is preserved over longer timescales. In general, MFQT can help quantify entanglement between electronic and nuclear degrees of freedom, and provide new routes to the study of ultrafast molecular dynamics, charge migration, quantum information processing, and optimal control schemes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Online task-space motion control for positioner-coordinated multi-robot manufacturing systems

Incorporating multiple robotic manipulators into large-scale manufacturing systems enhances production efficiency and expands manufacturing capabilities beyond those of single-robot systems. Workpiece positioners in robotic manufacturing have demonstrated significant benefits for process optimization, but coordination strategies for multi-robot systems with shared positioners have received limited attention. This work presents a task-space coordinated trajectory-tracking control framework for multi-robot manufacturing systems, in which robots coordinate their motions within a shared, dynamic workpiece positioning frame. A workpiece positioner actively adjusts the pose of the manufactured component to enable greater operational concurrency and improve overall production efficiency. The proposed motion-coordination scheme employs a distributed and scalable architecture, supporting coordination across heterogeneous multi-robot systems. Two optimization methodologies are introduced to manage kinematic redundancies and maintain continuous, near-optimal operation throughout the manufacturing process. The first strategy exploits a task-space dimensionality reduction to achieve locally optimal configurations by leveraging symmetry-axis rotations of the tool. The second strategy utilizes the workpiece positioner to drive the coordinated robots toward stable and kinematically favorable configurations. For both optimization strategies, multiple objectives are defined to improve key performance metrics, including manipulability, configuration consistency, proximity to mechanical limits, and motion efficiency. Addressing a key limitation of existing coordination approaches, the framework is designed around online setpoint modification, allowing coordinated robots to respond effectively to in-situ process feedback. The proposed control framework is validated using the Robot Operating System (ROS) middleware on a combination of physical and simulated multi-robot system hardware.

Arbogast, Alex [ORNL] (ORCID:0000000154740723)↗

Dynamic P-Q Capability and Abnormal Operation Analysis of a Wind Turbine with Doubly-Fed Induction Generator

After several accidents occurred in wind farms in the United States and around the world, the subsynchronous oscillation (SSO) issues in grid-connected wind farms have gained serious attention. Particularly, these issues have caused significant challenges to wind turbines with a doubly fed induction generator (DFIG) because it is connected to the grid via both its stator and rotor paths. Traditionally, a P-Q capability chart is utilized to assure the safe operation boundary for a synchronous generator. But the energy conversion characteristics of a DFIG wind turbine are completely different. A critical factor to affect the reliable operation of a DFIG wind turbine is the rated current and pulse-width modulation (PWM) saturation constraints of its power converters. These constraint conditions can be affected by the wind turbine rotating speed and grid conditions. However, a detailed study of DFIG P-Q capability from these perspectives has not been conducted, which has hindered adequate understanding of many abnormal wind turbine operations reported in the literature and the development of advanced control technologies to overcome the challenges. The proposed study in this paper considers vector control implementation to DFIG power electronic converters in the dq reference frame, and the models and algorithms developed for the P-Q capability study have addressed specific DFIG power converter constraints that are different from those of a traditional synchronous generator. The paper especially focuses on exploring the dynamic natures of DFIG P-Q capability under uncertain and variable conditions to explore the root causes of many abnormal operations of DFIG wind turbines reported in the literature. The proposed study is validated through an electromagnetic transient simulation model of a grid-connected DFIG wind turbine. The proposed study has the potential to lead to the development of new DFIG control technologies that can help overcome the challenges for many abnormal operations of DFIG wind turbines.

17 WIND ENERGY↗

Theory of edge localized mode suppression by static resonant magnetic perturbations in the DIII-D tokamak

According to a recent paper [Hu et al ., Phys. Plasmas 26, 120702 (2019)], mode penetration at the top of the pedestal is a necessary and sufficient condition for the suppression of edge localized modes (ELMs) by a resonant magnetic perturbation (RMPs) in an H-mode tokamak discharge. This paper employs asymptotic matching theory to model a particular DIII-D discharge in which ELMs were suppressed by an externally generated, static, n ¼ 2, RMP whose amplitude was modulated at a frequency of 1 Hz. It is demonstrated that the response of the plasma to the applied RMP, in the immediate vicinities of the rational (i.e., resonant) surfaces, is governed by nonlinear, rather than by linear, physics. This is the case because the magnetic island widths associated with driven reconnection exceed the linear layer widths, even in cases where driven reconnection is strongly suppressed by plasma rotation. The natural frequency at a given rational surface (i.e., the helical frequency at which the locally resonant component of the RMP would need to propagate in order to maximize driven reconnection) is found to be offset from the local E B frame in the ion diamagnetic direction. The size of the offset is mostly determined by neoclassical poloidal rotation. Finally, the predictions of a fully nonlinear plasma response model are found to be broadly consistent with the DIII-D experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incremental rotary rolling mill and method

A rolling mill system for Incremental rotary shaping of an elongated workpiece is provided that includes first and second workpiece holders. A support frame has a track with the first and second workpiece holders being movably associated with the track, the workpiece holders and an associated workpiece being movable in unison along the track. A radial chuck is mounted to the frame that includes a plurality of jaws that are movable radially inwardly and outwardly. Each jaw has a tool mounted thereto that is rotatable about an axis of rotation, with the axis of rotation of each tool being oriented at a skew angle relative to the longitudinal axis of a workpiece. A source of electric current and an electrically conductive flow path are provided for flowing electrical current through a workpiece. A controller is provided that is configured to control the operation of each of the first motor, second motor and third motor, and to control the flow of current flowing through the tools to the workpiece.

Zeng, Qiang↗

Disruptive neoclassical tearing mode seeding in DIII-D with implications for ITER

New studies identify the critical parameters and physics governing disruptive neoclassical tearing mode (NTM) onset. An m/n = 2/1 mode in DIII-D that begins to grow robustly after a seeding event (edge localized mode ELM or sawtooth precursor and crash) causes the mode rotation to drop close to the plasma's Er = 0 rest frame; this condition opens the stabilizing ion-polarization current 'gate' and destabilizes an otherwise marginally stable NTM. Our new experimental and theoretical insights and novel toroidal theory-based modeling are benchmarked and scalable to ITER and other future experiments. Here, the nominal ITER rotation at q = 2 is found to be stabilizing ('gate closed') except for MHD-induced transients that could 'open the gate'. Extrapolating from the DIII-D ITER baseline scenario (IBS) discharges, MHD transients are much more likely to destabilize problematic robustly growing 2/1 NTMs in ITER; this makes predictions of seeding and control of both ELMs and sawteeth imperative for more than just minimizing divertor pulsed-heat loading.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗