Search NASA⌕ Search

SEARCH · Search NASA

Results for “rotating mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Loss-cone stabilization in rotating mirrors: thresholds and thermodynamics

In the limit of sufficiently fast rotation, rotating mirror traps are known to be stable against the loss-cone modes associated with conventional (non-rotating) mirrors. This paper calculates how quickly a mirror configuration must rotate in order for several of these modes to be stabilized (in particular, the high-frequency convective loss cone, drift cyclotron loss cone and Dory–Guest–Harris modes). Commonalities in the stabilization conditions for these modes then motivate a modified formulation of the Gardner free energy and diffusively accessible free energy to be used for systems in which the important modes have wavevectors that are orthogonal or nearly orthogonal to the magnetic field, as well as a modification to include the effects of a loss region in phase space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Boundary Layer Transition Detection on a Rotor Blade Using Rotating Mirror Thermography

Laminar-to-turbulent transition on a rotor blade in hover has been imaged using an area-scan infrared camera. A new method for tracking a blade using a rotating mirror was employed. The mirror axis of rotation roughly corresponded to the rotor axis of rotation and the mirror rotational frequency is 1/2 that of the rotor. This permitted the use of cameras whose integration time was too long to prevent image blur due to the motion of the blade. This article will show the use of this method for a rotor blade at different collective pitch angles.

Imaging↗

Effect of insulator end cap thickness on time-dependent Hartmann flow in a rotating mirror

We present a framework for analysing plasma flow in a rotating mirror. By making a series of physical assumptions, we reduce the magnetohydrodynamic (MHD) equations in a three-dimensional cylindrical system to a one-dimensional system in a shallow, cuboidal channel within a transverse magnetic field, similar to the Hartmann flow in ducts. We then solve the system both numerically and analytically for a range of values of the Hartmann number and calculate the dependence of the plasma flow speed on the thickness of the insulating end cap. We observe that the mean flow overshoots and decelerates before achieving a steady-state value, a phenomenon that the analytical model cannot capture. This overshoot is directly proportional to the thickness of the insulating end cap and the external electric field, with a weak dependence on the external magnetic field. Our simplified model can act as a benchmark for future simulations of the supersonic mirror device CMFX (centrifugal magnetic fusion experiment), which will employ more sophisticated physics and realistic magnetic field geometries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ponderomotive barriers in rotating mirror devices using static fields

Particularly for aneutronic fusion schemes, it is advantageous to manipulate the fuel species differently from one another and to expel ash promptly. The ponderomotive effect can be used to selectively manipulate particles. It is commonly a result of particle–wave interactions and has a complex dependence on the particle charge and mass, enabling species selectivity. If the plasma is rotating, e.g., due to E x B motion, the ponderomotive effect can be generated using static (i.e., time-independent) perturbations to the electric and magnetic fields, which can be significantly cheaper to produce than time-dependent waves. We propose that this feature can be particularly useful in rotating mirror machines where mirror confinement can be enhanced by rotation, both through centrifugal confinement and additionally through a ponderomotive interaction with a static azimuthal perturbation. We identify specific static perturbations that generate a ponderomotive barrier and other perturbations that can generate either a repulsive barrier or an attractive ponderomotive well, which can be used to attract particles of a certain species while repelling another. We identify the regimes in which the ponderomotive potential can enhance net plasma confinement and the regime in which plasma confinement is not enhanced. The viability of each of these effects is found to be dependent on the specifics of the rotation profile and the resultant dispersion relation in the rotating plasma.

Aneutronic fusion↗

Hypervelocity impact studies using a rotating mirror framing laser shadowgraph camera

The need to study the effects of the impact of micrometeorites and orbital debris on various space-based systems has brought together the technologies of several companies and individuals in order to provide a successful instrumentation package. A light gas gun was employed to accelerate small projectiles to speeds in excess of 7 km/sec. Their impact on various targets is being studied with the help of a specially designed continuous-access rotating-mirror framing camera. The camera provides 80 frames of data at up to 1 x 10 to the 6th frames/sec with exposure times of 20 nsec.

Parker, Vance C.↗

Method and apparatus for optically monitoring the angular position of a rotating mirror

An optical system monitors the angular position of a rotating scanning mirror to indicate the effective start and end of each scan. At a certain angular position, a ray of energy transmitted to the mirror is reflected a plurality of times between the reflectors associated with the optical system and the line on the mirror parallel to the axis, and then to a detector to sense that angular position. A single optical system may be arranged to sense a plurality of different angular positions for each revolution of the mirror.

Lansing, J. C., Jr.↗

Massive, long-lived electrostatic potentials in a rotating mirror plasma

Abstract Hot plasma is highly conductive in the direction parallel to a magnetic field. This often means that the electrical potential will be nearly constant along any given field line. When this is the case, the cross-field voltage drops in open-field-line magnetic confinement devices are limited by the tolerances of the solid materials wherever the field lines impinge on the plasma-facing components. To circumvent this voltage limitation, it is proposed to arrange large voltage drops in the interior of a device, but coexist with much smaller drops on the boundaries. To avoid prohibitively large dissipation requires both preventing substantial drift-flow shear within flux surfaces and preventing large parallel electric fields from driving large parallel currents. It is demonstrated here that both requirements can be met simultaneously, which opens up the possibility for magnetized plasma tolerating steady-state voltage drops far larger than what might be tolerated in material media.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PHyTIR - A Prototype Thermal Infrared Radiometer

This paper describes the PHyTIR (Prototype HyspIRI Thermal Infrared Radiometer) instrument, which is the engineering model for the proposed HyspIRI (Hyperspectral Infrared Imager) earth observing instrument. The HyspIRI mission would be comprised of the HyspIRI TIR (Thermal Infrared Imager), and a VSWIR (Visible Short-Wave Infra-Red Imaging Spectrometer). Both instruments would be used to address key science questions related to the earth's carbon cycle, ecosystems, climate, and solid earth properties. Data gathering of volcanic activities, earthquakes, wildfires, water use and availability, urbanization, and land surface compositions and changes, would aid the predictions and evaluations of such events and the impact they create. Even though the proposed technology for the HyspIRI imager is mature, the PHyTIR prototype is needed to advance the technology levels for several of the instrument's key components, and to reduce risks, in particular to validate 1) the higher sensitivity, spatial resolution, and higher throughput required for this focal plane array, 2) the pointing accuracy, 2) the characteristics of several spectral channels, and 4) the use of ambient temperature optics. The PHyTIR telescope consists of the focal plane assembly that is housed within a cold housing located inside a vacuum enclosure; all mounted to a bulkhead, and an optical train that consists of 3 powered mirrors; extending to both sides of the bulkhead. A yoke connects the telescope to a scan mirror. The rotating mirror enables to scan- a large track on the ground. This structure is supported by kinematic mounts, linking the telescope assembly to a base plate that would also become the spacecraft interface for HyspIRI. The focal plane's cooling units are also mounted to the base plate, as is an overall enclosure that has two viewing ports with large exterior baffles, shielding the focal plane from incoming stray light. PHyTIR's electronics is distributed inside and near the vacuum enclosure, and in a nearby rack. The data acquisition technique would be to take measurements over a 51deg wide swath in the cross spacecraft velocity direction, which is brought into view through the rotating scan mirror. A landscape mosaic thus can be assembled by overlaying rows of measurements. The paper briefly outlines the proposed HyspIRI mission and its data acquisition technique; it then describes the prototype PHyTIR instrument.

Space Instrument↗

The CZCS geolocation algorithms

The Coastal Zone Color Scanner (CZCS) on board the Nimbus 7 satellite was designed to measure surface radiance upwelled from the ocean in 6 spectral bands. The CZCS spectrometer obtains its information from a rotating mirror and is timed to collect data when the mirror views the Earth surface between ca. 40 degrees to the left and right of the subsatellite track. Each scan is divided into 1968 picture elements, pixels, of 0.04 degrees scan each. In order to avoid direct reflected Sun glint, the rotating mirror shaft can be tilted so that scans across the subsatellite track up to 20 degrees forward or aft of the point directed beneath the satellite. The CZCS is the first satellite borne instrument to have this tilted scan capability and therefore poses some new problems in locating the Earth surface position of viewed pixels.

Wilson, W. H.↗

Tunable symmetry breaking in a hexagonal-stacked moiré magnet

Symmetry plays a central role in defining magnetic phases, making tunable symmetry breaking across magnetic transitions highly desirable for discovering non-trivial magnetism. Magnetic moiré superlattices, formed by twisting two-dimensional magnetic crystals, have been theoretically proposed and experimentally explored as platforms for unconventional magnetic states. However, despite recent advances, the ability to tune symmetry breaking in moiré magnetism remains limited, as twisted two-dimensional magnets predominantly inherit the magnetic properties and symmetries of their constituent layers. Here, in this work, we demonstrate a clear evolution of symmetry in hexagonal-stacked twisted double-bilayer CrI 3 as the twist angle increases from 180° to 190°. Although the net magnetization remains zero across this twist-angle range, the magnetic phase breaks only the threefold rotational symmetry at 180°, but it breaks all the rotational, mirror and time-reversal symmetries at intermediate twist angles between 181° and 185°, and all broken symmetries are recovered at 190°. This pronounced symmetry breaking at intermediate twist angles is accompanied by metamagnetic behaviour, evidenced by symmetric double hysteresis loops around zero magnetic field. Together, these results reveal that hexagonal-stacked twisted double-bilayer CrI3 at intermediate twist angles hosts a distinct moiré magnetic phase, featuring periodic in-plane spin textures with broken rotational, mirror and time-reversal symmetries.

Sun, Zeliang (ORCID:0009000770748064)↗

Origin of the framing camera.

Framing cameras of rotating mirror type, discussing optical principles used in American, British and Russian high speed cameras developed since original NACA camera

HIGH SPEED CAMERA↗

Origin of the framing camera.

Framing cameras of rotating mirror type, discussing optical principles used in American, British and Russian high speed cameras developed since original NACA camera

FRAMING CAMERA↗

Development of replicated optics for AXAF-1 XDA testing

Advanced optical systems for applications such as grazing incidence Wolter I x-ray mirror assemblies require extraordinary mirror surfaces in terms of fine finish and surface figure. The impeccable mirror surface is on the inside of the rotational mirror form. One practical method of producing devices with these requirements is to first fabricate an exterior surface for the optical device then replicate that surface to have the inverse component with lightweight characteristics. The replicated optic is not better than the master or mandrel from which it is made. This task identifies methods and materials for forming these extremely low roughness optical components. The objectives of this contract were to (1) prepare replication samples of electroless nickel coated aluminum, and determine process requirements for plating XDA test optic; (2) prepare and assemble plating equipment required to process a demonstration optic; (3) characterize mandrels, replicas and test samples for residual stress, surface contamination and surface roughness and figure using equipment at MSFC and; (4) provide technical expertise in establishing the processes, procedures, supplies and equipment needed to process the XDA test optics.

Engelhaupt, Darell↗

Replicated Composite Optics Development

Advanced optical systems for applications such as grazing incidence Wolter I x-ray mirror assemblies require extraordinary mirror surfaces in ten-ns of fine surface finish and figure. The impeccable mirror surface is on the inside of the rotational mirror form. One practical method of producing devices with these requirements is to first fabricate an exterior surface for the optical device then replicate that surface to have the inverse component with lightweight characteristics. The replicate optic is not better than the master or mandrel from which it is made. This task is a continuance of previous studies to identify methods and materials for forming these extremely low roughness optical components.

Engelhaupt, Darell↗

Multispectral variable magnification glancing incidence x ray telescope

A multispectral, variable magnification, glancing incidence, x-ray telescope capable of broadband, high resolution imaging of solar and stellar x-ray and extreme ultraviolet radiation sources is discussed. The telescope includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable mirror carriers, each providing a different magnification, are positioned behind the primary focus at an inclination to the optical axis. Each carrier has a series of ellipsoidal mirrors, and each mirror has a concave surface covered with a multilayer (layered synthetic microstructure) coating to reflect a different desired wavelength. The mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A detector such as an x-ray sensitive photographic film is positioned at the second respective focus of each mirror so that each mirror may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected mirror on the second carrier to receive the radiation.

Hoover, Richard B.↗

JPSS-1 VIIRS Pre-Launch Response Versus Scan Angle Testing and Performance

The Visible Infrared Imaging Radiometer Suite (VIIRS) instruments on-board both the Suomi National Polar-orbiting Partnership (S-NPP) and the first Joint Polar Satellite System (JPSS-1) spacecraft, with launch dates of October 2011 and December 2016 respectively, are cross-track scanners with an angular swath of +/-56.06 deg. A four-mirror Rotating Telescope Assembly (RTA) is used for scanning combined with a Half Angle Mirror (HAM) that directs light exiting from the RTA into the aft-optics. It has 14 Reflective Solar Bands (RSBs), seven Thermal Emissive Bands (TEBs) and a panchromatic Day Night Band (DNB). There are three internal calibration targets, the Solar Diffuser, the BlackBody and the Space View, that have fixed scan angles within the internal cavity of VIIRS. VIIRS has calibration requirements of 2% on RSB reflectance and as tight as 0.4% on TEB radiance that requires the sensor's gain change across the scan or Response Versus Scan angle (RVS) to be well quantified. A flow down of the top level calibration requirements put constraints on the characterization of the RVS to 0.2%-0.3% but there are no specified limitations on the magnitude of response change across scan. The RVS change across scan angle can vary significantly between bands with the RSBs having smaller changes of approximately 2% and some TEBs having approximately 10% variation. Within aband, the RVS has both detector and HAM side dependencies that vary across scan. Errors in the RVS characterization will contribute to image banding and striping artifacts if their magnitudes are above the noise level of the detectors. The RVS was characterized pre-launch for both S-NPP and JPSS-1 VIIRS and a comparison of the RVS curves between these two sensors will be discussed.

Moyer, David↗

A cloud physics radiometer

The paper describes the design features and capabilities of a seven-channel cloud physics radiometer (CPR) for remote sensing of cloud properties. The CPR channel characteristics and functions are tabulated and diagrammed. Each of the first three channels utilizes a photo-multipler detector, with the high-voltage power supply integrated with the tube into a single unit. In operation a heater is used to keep the optics temperature at or above 273 K and this temperature is constantly monitored. The last four channel detectors and filters are all cooled to the temperature of liquid nitrogen. The inclined scanning mirror rotates at a rate of 3.48 rps. Registration pulses are triggered and recorded as the mirror enters and leaves the + or -45 deg earth observation region. The ice-cloud, water cloud, snow discriminator detector has worked quite well in general. Interesting radiometer data have been obtained and their analysis is under way. The combination of the CPR and the Cloud Lidar System will make possible sophisticated remote sensing cloud studies.

Kyle, H. L.↗