Search NASA⌕ Search

SEARCH · Search NASA

Results for “rotating mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Boundary Layer Transition Detection on a Rotor Blade Using Rotating Mirror Thermography

Laminar-to-turbulent transition on a rotor blade in hover has been imaged using an area-scan infrared camera. A new method for tracking a blade using a rotating mirror was employed. The mirror axis of rotation roughly corresponded to the rotor axis of rotation and the mirror rotational frequency is 1/2 that of the rotor. This permitted the use of cameras whose integration time was too long to prevent image blur due to the motion of the blade. This article will show the use of this method for a rotor blade at different collective pitch angles.

Imaging↗

Hypervelocity impact studies using a rotating mirror framing laser shadowgraph camera

The need to study the effects of the impact of micrometeorites and orbital debris on various space-based systems has brought together the technologies of several companies and individuals in order to provide a successful instrumentation package. A light gas gun was employed to accelerate small projectiles to speeds in excess of 7 km/sec. Their impact on various targets is being studied with the help of a specially designed continuous-access rotating-mirror framing camera. The camera provides 80 frames of data at up to 1 x 10 to the 6th frames/sec with exposure times of 20 nsec.

Parker, Vance C.↗

Method and apparatus for optically monitoring the angular position of a rotating mirror

An optical system monitors the angular position of a rotating scanning mirror to indicate the effective start and end of each scan. At a certain angular position, a ray of energy transmitted to the mirror is reflected a plurality of times between the reflectors associated with the optical system and the line on the mirror parallel to the axis, and then to a detector to sense that angular position. A single optical system may be arranged to sense a plurality of different angular positions for each revolution of the mirror.

Lansing, J. C., Jr.↗

PHyTIR - A Prototype Thermal Infrared Radiometer

This paper describes the PHyTIR (Prototype HyspIRI Thermal Infrared Radiometer) instrument, which is the engineering model for the proposed HyspIRI (Hyperspectral Infrared Imager) earth observing instrument. The HyspIRI mission would be comprised of the HyspIRI TIR (Thermal Infrared Imager), and a VSWIR (Visible Short-Wave Infra-Red Imaging Spectrometer). Both instruments would be used to address key science questions related to the earth's carbon cycle, ecosystems, climate, and solid earth properties. Data gathering of volcanic activities, earthquakes, wildfires, water use and availability, urbanization, and land surface compositions and changes, would aid the predictions and evaluations of such events and the impact they create. Even though the proposed technology for the HyspIRI imager is mature, the PHyTIR prototype is needed to advance the technology levels for several of the instrument's key components, and to reduce risks, in particular to validate 1) the higher sensitivity, spatial resolution, and higher throughput required for this focal plane array, 2) the pointing accuracy, 2) the characteristics of several spectral channels, and 4) the use of ambient temperature optics. The PHyTIR telescope consists of the focal plane assembly that is housed within a cold housing located inside a vacuum enclosure; all mounted to a bulkhead, and an optical train that consists of 3 powered mirrors; extending to both sides of the bulkhead. A yoke connects the telescope to a scan mirror. The rotating mirror enables to scan- a large track on the ground. This structure is supported by kinematic mounts, linking the telescope assembly to a base plate that would also become the spacecraft interface for HyspIRI. The focal plane's cooling units are also mounted to the base plate, as is an overall enclosure that has two viewing ports with large exterior baffles, shielding the focal plane from incoming stray light. PHyTIR's electronics is distributed inside and near the vacuum enclosure, and in a nearby rack. The data acquisition technique would be to take measurements over a 51deg wide swath in the cross spacecraft velocity direction, which is brought into view through the rotating scan mirror. A landscape mosaic thus can be assembled by overlaying rows of measurements. The paper briefly outlines the proposed HyspIRI mission and its data acquisition technique; it then describes the prototype PHyTIR instrument.

Space Instrument↗

The CZCS geolocation algorithms

The Coastal Zone Color Scanner (CZCS) on board the Nimbus 7 satellite was designed to measure surface radiance upwelled from the ocean in 6 spectral bands. The CZCS spectrometer obtains its information from a rotating mirror and is timed to collect data when the mirror views the Earth surface between ca. 40 degrees to the left and right of the subsatellite track. Each scan is divided into 1968 picture elements, pixels, of 0.04 degrees scan each. In order to avoid direct reflected Sun glint, the rotating mirror shaft can be tilted so that scans across the subsatellite track up to 20 degrees forward or aft of the point directed beneath the satellite. The CZCS is the first satellite borne instrument to have this tilted scan capability and therefore poses some new problems in locating the Earth surface position of viewed pixels.

Wilson, W. H.↗

Origin of the framing camera.

Framing cameras of rotating mirror type, discussing optical principles used in American, British and Russian high speed cameras developed since original NACA camera

HIGH SPEED CAMERA↗

Origin of the framing camera.

Framing cameras of rotating mirror type, discussing optical principles used in American, British and Russian high speed cameras developed since original NACA camera

FRAMING CAMERA↗

Development of replicated optics for AXAF-1 XDA testing

Advanced optical systems for applications such as grazing incidence Wolter I x-ray mirror assemblies require extraordinary mirror surfaces in terms of fine finish and surface figure. The impeccable mirror surface is on the inside of the rotational mirror form. One practical method of producing devices with these requirements is to first fabricate an exterior surface for the optical device then replicate that surface to have the inverse component with lightweight characteristics. The replicated optic is not better than the master or mandrel from which it is made. This task identifies methods and materials for forming these extremely low roughness optical components. The objectives of this contract were to (1) prepare replication samples of electroless nickel coated aluminum, and determine process requirements for plating XDA test optic; (2) prepare and assemble plating equipment required to process a demonstration optic; (3) characterize mandrels, replicas and test samples for residual stress, surface contamination and surface roughness and figure using equipment at MSFC and; (4) provide technical expertise in establishing the processes, procedures, supplies and equipment needed to process the XDA test optics.

Engelhaupt, Darell↗

Replicated Composite Optics Development

Advanced optical systems for applications such as grazing incidence Wolter I x-ray mirror assemblies require extraordinary mirror surfaces in ten-ns of fine surface finish and figure. The impeccable mirror surface is on the inside of the rotational mirror form. One practical method of producing devices with these requirements is to first fabricate an exterior surface for the optical device then replicate that surface to have the inverse component with lightweight characteristics. The replicate optic is not better than the master or mandrel from which it is made. This task is a continuance of previous studies to identify methods and materials for forming these extremely low roughness optical components.

Engelhaupt, Darell↗

Multispectral variable magnification glancing incidence x ray telescope

A multispectral, variable magnification, glancing incidence, x-ray telescope capable of broadband, high resolution imaging of solar and stellar x-ray and extreme ultraviolet radiation sources is discussed. The telescope includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable mirror carriers, each providing a different magnification, are positioned behind the primary focus at an inclination to the optical axis. Each carrier has a series of ellipsoidal mirrors, and each mirror has a concave surface covered with a multilayer (layered synthetic microstructure) coating to reflect a different desired wavelength. The mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A detector such as an x-ray sensitive photographic film is positioned at the second respective focus of each mirror so that each mirror may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected mirror on the second carrier to receive the radiation.

Hoover, Richard B.↗

JPSS-1 VIIRS Pre-Launch Response Versus Scan Angle Testing and Performance

The Visible Infrared Imaging Radiometer Suite (VIIRS) instruments on-board both the Suomi National Polar-orbiting Partnership (S-NPP) and the first Joint Polar Satellite System (JPSS-1) spacecraft, with launch dates of October 2011 and December 2016 respectively, are cross-track scanners with an angular swath of +/-56.06 deg. A four-mirror Rotating Telescope Assembly (RTA) is used for scanning combined with a Half Angle Mirror (HAM) that directs light exiting from the RTA into the aft-optics. It has 14 Reflective Solar Bands (RSBs), seven Thermal Emissive Bands (TEBs) and a panchromatic Day Night Band (DNB). There are three internal calibration targets, the Solar Diffuser, the BlackBody and the Space View, that have fixed scan angles within the internal cavity of VIIRS. VIIRS has calibration requirements of 2% on RSB reflectance and as tight as 0.4% on TEB radiance that requires the sensor's gain change across the scan or Response Versus Scan angle (RVS) to be well quantified. A flow down of the top level calibration requirements put constraints on the characterization of the RVS to 0.2%-0.3% but there are no specified limitations on the magnitude of response change across scan. The RVS change across scan angle can vary significantly between bands with the RSBs having smaller changes of approximately 2% and some TEBs having approximately 10% variation. Within aband, the RVS has both detector and HAM side dependencies that vary across scan. Errors in the RVS characterization will contribute to image banding and striping artifacts if their magnitudes are above the noise level of the detectors. The RVS was characterized pre-launch for both S-NPP and JPSS-1 VIIRS and a comparison of the RVS curves between these two sensors will be discussed.

Moyer, David↗

A cloud physics radiometer

The paper describes the design features and capabilities of a seven-channel cloud physics radiometer (CPR) for remote sensing of cloud properties. The CPR channel characteristics and functions are tabulated and diagrammed. Each of the first three channels utilizes a photo-multipler detector, with the high-voltage power supply integrated with the tube into a single unit. In operation a heater is used to keep the optics temperature at or above 273 K and this temperature is constantly monitored. The last four channel detectors and filters are all cooled to the temperature of liquid nitrogen. The inclined scanning mirror rotates at a rate of 3.48 rps. Registration pulses are triggered and recorded as the mirror enters and leaves the + or -45 deg earth observation region. The ice-cloud, water cloud, snow discriminator detector has worked quite well in general. Interesting radiometer data have been obtained and their analysis is under way. The combination of the CPR and the Cloud Lidar System will make possible sophisticated remote sensing cloud studies.

Kyle, H. L.↗

Precision Select Mechanisms for the GLAS and SOLSE2 Instruments

The Geoscience Laser Altimeter System (GLAS) instrument had requirements for a 2-position mechanism to rotate mirrors into and out of the optical path of the altimetry detectors and the lasers. The Solar Ozone Limb Sounding Experiment II (SOLSE2) instrument had a similar requirement of rotating a visible (VIS) or ultraviolet (W) filter into the instrument optical path. Both GLAS and SOLSE2 had similar operational and survival environments and lifetime requirements. A novel, precision rotational latching mechanism was designed to fulfill the needs of both missions. The GLAS instrument had driving stability and repeatability requirements, such that if the mechanism met these stringent requirements, it would more than surpass the required performance for the SOLSE2 mechanism. The resulting mechanism, referred to as a 'select mechanism' since it allows selection between 2 positions, was successfully designed and implemented for both missions.

Budinoff, Jason G.↗

Optical scanner

An optical scanner for imaging lines in an object plane onto a linear array in a focal plane either continuously or discretely is described. The scanner consists of a set of four mutually perpendicularly oriented plane corner mirrors which provide a reflecting path that describes a parallelogram. In addition, there is a plane parallel scanning mirror with a front and back reflecting surface located midway between the first and fourth corner mirrors. It is oriented so that in the mid-scan position it is parallel to the first corner mirror, and therefore perpendicular to the fourth corner mirror. As the scan mirror rotates, rays incident from a plurality of lines in the object plane are selectively directed through the optical system arriving at a common intersection on the back surface of the scanning mirror where the rays are colinearly directed toward a lens and then imaged onto the linear array in the focal plane. A set of compensating mirrors may be introduced just before the imaging lens to compensate for a small and generally negligible path difference delta sub l between the axial and marginal rays.

Finkel, Mitchell W.↗

Mechanisms of UK radiometers flown on Nimbus 5 and 6 with particular reference to bearings, pivots and lubrication

The mechanisms incorporated in the vertical sounding infrared radiometry experiments which were launched on Nimbus 5 in 1972 and on Nimbus 6 in 1975 are discussed. Both use dry lubricants. The Nimbus 5 radiometer includes a rotating chopper driven via a carbon fiber-acetal resin gearwheel. The driving motor runs at 2000 rpm and has completed over 7 x 10 to the 9th power revolutions. Four gear driven filter wheels powered by stepper motors have each completed 2 x 10 to the 8th power changes. The input calibration mirror mechanism and its field of view compensation mechanisms are also described. All 25 ball races used in the experiment are of the film transfer type. The Nimbus 6 radiometer includes two cells. Each contains a piston supported on diaphragm springs and driven electromagnetically. The pistons are 6 cm in diameter with a stroke of 1 cm and are driven at their mechanical resonant frequency of approx. 15 Hz. The calibrating mirrors rotate periodically to view a target. The support pivots are synthetic sapphire ring stones with separate end thrust stones. The problems of mounting these stones to withstand vibration loads is described.

Hadley, H.↗

Measurement of structure motion by means of a moving light sheet

The elaboration of an optical system which measures the displacement and velocity of large flexible space structures is reviewed. The motion-measuring system, comprised of a laser, optics, motorized mirror, two photodiodes and electronics, is designed to allow feedback for configuration control of flexible structures. A motor or scanner is employed to sweep the light sheet. The range of motion was shown to be 2 inches, and information was received at a rate of 30 Hz. The uncertainty in displacement measurement was better than +0.01 inch from a distance of 16 feet. The results are considered to be very good for two scanning light sheet systems. Higher sample rates and a more constant speed would improve the rotating mirror option, and the accuracy and range of the scanning mirror option could be upgraded as well. Both setups are shown to be viable noncontact measuring methods for the displacement and velocity of large space structures.

Tcheng, Ping↗

Modeling Studies of the MODIS Solar Diffuser Attenuation Screen and Comparison with On-Orbit Measurements

The MODIS instrument relies on solar calibration to achieve the required radiometric accuracy. This solar calibration occurs as the TERRA spacecraft comes up over the North Pole. The earth underneath the spacecraft is still dark for approximately one minute and the sun is just rising over the earth's north polar regions. During this time the sun moves through about 4 degrees, the scan mirror rotates about 19 times and about 50 frames (exposures) are made of the white solar diffuser. For some of MODIS'S bands the brightness of the screen is reduced, to prevent detector saturation, by means of a pinhole screen, which produces approximately 600 pinhole images of the sun within the field of view of any one detector. Previous attempts at creating a detailed radiometric model of this calibration scenario produced intensity variations on the focal planes with insufficient detail to be useful. The current computational approach produces results, which take into account the motion of the sun and the scan mirror and produces variations, which strongly resemble the observed focal plane intensity variations. The computational approach and results and a comparison with actual observational data are presented.

Waluschka, Eugene↗