Search NASA⌕ Search

SEARCH · Search NASA

Results for “rotating shadowband radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Aerosol Optical Depth Best Estimate Value-Added Product Report

Four aerosol optical depth (AOD) products are offered by four collocated ground-based instruments deployed at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory (SGP Central Facility 1 [C1] and Extended Facility 13 [E13]) for more than two decades. Two of these instruments, the multifilter rotating shadowband radiometers (MFRSRs C1 and E13), are sensors with horizontal hemispherical receivers shaded by rotating shadowbands.

47 OTHER INSTRUMENTATION↗

Evaluation of the hyperspectral radiometer (HSR1) at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site

Abstract. The Peak Design Ltd hyperspectral radiometer (HSR1) was tested at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) site in Lamont, Oklahoma, for 2 months from May to July 2022. The HSR1 is a prototype instrument that measures total (Ftotal) and diffuse (Fdiffuse) spectral irradiance from 360 to 1100 nm with a spectral resolution of 3 nm. The HSR1 spectral irradiance measurements are compared to nearby collocated spectral radiometers, including two multifilter rotating shadowband radiometers (MFRSRs) and the Shortwave Array Spectroradiometer–Hemispheric (SASHe) radiometer. The Ftotal at 500 nm for the HSR1 compared to the MFRSRs has a mean (relative) difference of 0.01 W m−2 nm−1 (1 %–2 %). The HSR1 mean Fdiffuse at 500 nm is smaller than the MFRSRs' by 0.03–0.04 (10 %) W m−2 nm−1. The HSR1 clear-sky aerosol optical depth (AOD) is also retrieved by considering Langley regressions and compared to collocated instruments such as the Cimel sunphotometer (CSPHOT), MFRSRs, and SASHe. The mean HSR1 AOD at 500 nm is larger than the CSPHOT's by 0.010 (8 %) and larger than the MFRSRs' by 0.007–0.017 (6 %–18 %). In general, good agreement between the HSR1 and other instruments is found in terms of the Ftotal, Fdiffuse, and AODs at 500 nm. The HSR1 quantities are also compared at other wavelengths to the collocated instruments. The comparisons are within ∼ 10 % for the Ftotal and Fdiffuse, except for 940 nm, where there is relatively larger disagreement. The AOD comparisons are within ∼ 10 % at 415 and 440 nm; however, a relatively larger disagreement in the AOD comparison is found for higher wavelengths.

54 ENVIRONMENTAL SCIENCES↗

Shortwave Array Spectroradiometer-Hemispheric (SAS-He): design and evaluation

A novel ground-based radiometer, referred to as the Shortwave Array Spectroradiometer-Hemispheric (SAS-He), is introduced. This radiometer uses the shadow-band technique to report total irradiance and its direct and diffuse components frequently (every 30 s) with continuous spectral coverage (350–1700 nm) and moderate spectral (~2.5 nm ultraviolet–visible and ~6 nm shortwave-infrared) resolution. The SAS-He's performance is evaluated using integrated datasets collected over coastal regions during three field campaigns supported by the US Department of Energy's Atmospheric Radiation Measurement (ARM) program, namely the (1) Two-Column Aerosol Project (TCAP; Cape Cod, Massachusetts), (2) Tracking Aerosol Convection Interactions Experiment (TRACER; in and around Houston, Texas), and (3) Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE; La Jolla, California). We compare (i) aerosol optical depth (AOD) and total optical depth (TOD) derived from the direct irradiance, as well as (ii) the diffuse irradiance and direct-to-diffuse ratio (DDR) calculated from two components of the total irradiance. As part of the evaluation, both AOD and TOD derived from the SAS-He direct irradiance are compared to those provided by a collocated Cimel sunphotometer (CSPHOT) at five (380, 440, 500, 675, 870 nm) and two (1020, 1640 nm) wavelengths, respectively. Additionally, the SAS-He diffuse irradiance and DDR are contrasted with their counterparts offered by a collocated multifilter rotating shadowband radiometer (MFRSR) at six (415, 500, 615, 675, 870, 1625 nm) wavelengths. Overall, reasonable agreement is demonstrated between the compared products despite the challenging observational conditions associated with varying aerosol loadings and diverse types of aerosols and clouds. For example, the AOD- and TOD-related values of root mean square error remain within 0.021 at 380, 440, 500, 675, 870, 1020, and 1640 nm wavelengths during the three field campaigns.

47 OTHER INSTRUMENTATION↗

Aerosol Optical Depth Value-Added Product Report

This document describes the process applied to retrieve aerosol optical depth (AOD) from multifilter rotating shadowband radiometers (MFRSR) and normal incidence multifilter radiometers (NIMFR) operated at the ARM Climate Research Facility’s ground-based facilities.

54 ENVIRONMENTAL SCIENCES↗

Droplet Number Concentration Value-Added Product

The ndrop_mfrsr value-added product (VAP) provides an estimate of the cloud droplet number concentration of overcast water clouds retrieved from cloud optical depth from the multi-filter rotating shadowband radiometer (MFRSR) instrument and liquid water path (LWP) retrieved from the microwave radiometer (MWR). When cloud layer information is available from vertically pointing lidar and radars in the Active Remote Sensing of Clouds (ARSCL) product, the VAP also provides estimates of the adiabatic LWP and an adiabatic parameter (beta) that indicates how divergent the LWP is from the adiabatic case. quality control (QC) flags (qc_drop_number_conc), an uncertainty estimate (drop_number_conc_toterr), and a cloud layer type flag (cloud_base_type) are useful indicators of the quality and accuracy of any given value of the retrieval. Examples of these major input and output variables are given in sample plots in section 6.0.

97 MATHEMATICS AND COMPUTING↗

ARM Shortwave Spectral Radiometry Strategy Review Report

A meeting of experts in shortwave (SW) spectral measurements was held in February 2019 to discuss the current state of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrumentation and the potential scientific impact of these measurements. Instrument mentors and users reported significant progress in hyperspectral measurement quality, with good-quality data sets now possible at several field campaigns and fixed sites. Ongoing filter-based measurement improvements, including addition of the 1.6-micron channel to the multifilter rotating shadowband radiometer (MFRSR) and lunar tracking mode of the Cimel sun photometers, were also lauded as exciting developments to improve retrievals of aerosol radiative properties and size distributions.

54 ENVIRONMENTAL SCIENCES↗

ARM Shortwave Spectral Radiometry Strategy Review Report

A meeting of experts in shortwave (SW) spectral measurements was held in February 2019 to discuss the current state of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrumentation and the potential scientific impact of these measurements. Instrument mentors and users reported significant progress in hyperspectral measurement quality, with good-quality data sets now possible at several field campaigns and fixed sites. Ongoing filter-based measurement improvements, including addition of the 1.6-micron channel to the multifilter rotating shadowband radiometer (MFRSR) and lunar tracking mode of the Cimel sun photometers, were also lauded as exciting developments to improve retrievals of aerosol radiative properties and size distributions.

54 ENVIRONMENTAL SCIENCES↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

Worldwide benchmarking of cost-effective radiometers for direct and diffuse irradiance

Solar energy projects can benefit from direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) measurements during all project phases. Several commercial measurement systems for DNI and DHI are available. Sun trackers with pyranometers and pyrheliometers can provide highly accurate measurements but are often impractical in solar energy applications. For less expensive and more robust sensors, it is often unclear which accuracy can be expected under a project site's specific atmospheric conditions. We address this challenge through our dedicated experimental comparison of relevant sensor systems (rotating shadowband irradiometer [short RSI], Delta-T SPN1, EKO MS-90, PyranoCam, Sunto CaptPro, Kipp & Zonen CSD3) at up to six sites worldwide. The RSI systems (rRMSD 3 to 8.6%, DNI; 4.8 to 7.6%, DHI) and PyranoCam (rRMSD 2.6 to 5.2%, DNI; 4.4 to 5.8%, DHI) exhibit similar error metrics and are the most accurate systems in the test. Delta-T SPN1 and EKO MS-90 (rRMSD 6.8 to 15%, DNI; 10.6 to 20.1%, DHI) but especially Kipp & Zonen CSD3 and Sunto CaptPro show significant deviations (rRMSD 17.7 to 20%, DNI; 33 to 58%, DHI). We evaluate the influence of relevant atmospheric parameters on the sensors' accuracies by a rather unique measurement setup. MS-90's DNI errors depend on DNI itself, with overestimations for low reference DNI. The deviations of SPN1's DHI and DNI measurements increase sharply in situations with high circumsolar irradiance. Also CaptPro and CSD3's increased measurement errors are related to circumsolar irradiance. For RSI and PyranoCam, only moderate influences on the measurements are identified, indicating a general applicability of these instruments.

14 SOLAR ENERGY↗